| 4 | L4₹50.0 L+₹1.0 L (2.11%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹50.1 L+₹1.1 L (2.27%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹84,600
Closing Date
25 Feb 2021, 6:00 pmClosed
Lt Col Bhamre Kiran S
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
PROVISION OF CERTAIN E/M SANCTION WORK (I.E. MAJOR REVENUE, MINOR WORKS AND SPECIAL REPAIR) UNDER GE (AF) JAMNAGAR NO.1
2021_MES_417359_1
8784/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) JAMNAGAR NO.1
₹84,600
Yes
15 Mar 2021
30 Jan 2021
26 Feb 2021
30 Jan 2021
25 Feb 2021
18 Feb 2021
Amount
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC concealed Conduit 20 mm dia , including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size for modular switch complete all as specified and directed by Engr-in-charge.
Note:- Cutting chases wherever required for concealed wiring will be measured & paid separately.
All as per item No 1 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch.
All as per item No 1 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch.
All as per item No 1 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
M&L modular Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete.
M & L for modular socket white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete.
M & L for modular Switch socket combination white polycarbonate body, 6A / 16A- 230 V, Multipurpose, indicator based including connecting complete.
M & L for Ceiling rose 3 pin flush type 6 Amps, 240 volts AC ISI marked
Supply and fix white cover plate with frame 6 to 8 module
Supply and fix white cover plate with frame 2 to 4 module
Material & Labour for sub main wiring with 4 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 4 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
S&F Distribution board made out of sheet metal powder coated, factory made, enclosure double door type TPN 4 way vertical type with 200 (Amps rated copper bus bar, neutral bar, earth bar, TP 43 protection including provision of 1 nos incomer MCCB 63 Amps, triple pole and neutral, 415V, 16 KA breaking capacity fixing of DB flush to wall surface complete all as specified and directed.
S & F MCCB 63 Amps, 10 KA TPN fixed in DB/Panel box complete all as specified and as directed. Make :- Havells/C&S/L&T
S & F metal clad plug & socket board TP & N enclosure with 2 pole and earth metal plug & socket complete with 20 Amp MCB SP, C curve complete all as specified and directed.
Supply and Fix MCB’s single pole of 6 to 32 Amps capacity, fixed in sheet metal board complete including connection complete all as specified and directed.
Supply and Fixing MCB’s single pole & neutral, 6 to 32 Amps capacity, fixed in sheet metal board complete including connecting complete all as specified and directed.
Supply and Fixing MCB’s Triple pole 6 to 32 Amps capacity, fixed in sheet metal board complete including connecting complete all as specified and directed.
Supply & Fixing 3 Pole MCCB 250 Amps, 415V, with rupturing cap 53 KA.
S&F energy efficient LED tube light fitting with built in LED & integral LED driver 18 to 20 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
Supply and fix LED Type Aviation obstruction light comprising of aluminium housing with polycarbonate enclosure LED to be provided fixed in position all as directed.
Taking down LT U/G Cable from trenches/poles aluminium conductor of size 10 Sqmm to 35 Sqmm all as specified and directed by Engr-in-charge.
Taking down LT U/G Cable from trenches/poles aluminium conductor of size 50 Sqmm to 95 Sqmm all as specified and directed by Engr-in-charge.
Taking down LT U/G Cable from trenches/poles aluminium conductor of size 120 Sqmm to 300 Sqmm all as specified and directed by Engr-in-charge.
Taking down HT U/G Cable from trenches/poles aluminium conductor of size 95 Sqmm all as specified and directed by Engr-in-charge.
Taking out LT U/G cable of any size from existing loop of the cable and re-connecting the same in existing raised panel all as directed by Engr-in-charge. Note:- (a) Excavation work in any type of soil for taking out loop, Returning and filling is deemed to be included in the rate quoted.
Supply & Lay XLPE insulated PVC inner sheathed armoured with galvanised steel strip or wire, heavy duty LT underground cable ISI marked with aluminium multistranded conductor 1100 volts grade of size 16 sqmm 4 core laid in trenches/duct passing through pipe/duct or fixed on pole and connecting and testing complete.
All as per item No.26 here-in-before but of size 25 Sqmm 4 core
All as per item No.26 here-in-before but of size 35 Sqmm 3.5 core
All as per item No.26 here-in-before but of size 50 Sqmm 3.5 core
All as per item No.26 here-in-before but of size 70 Sqmm 3.5 core
All as per item No.26 here-in-before but of size 95 Sqmm 3.5 core
All as per item No.26 here-in-before but of size 120 Sqmm 3.5 core
All as per item No.26 here-in-before but of size 150 Sqmm 3.5 core
All as per item No.26 here-in-before but of size 185 Sqmm 3.5 core
All as per item No.26 here-in-before but of size 240 Sqmm 3.5 core
All as per item No.26 here-in-before but of size 300 Sqmm 3.5 core
Supply & Lay XLPE insulated PVC inner sheathed armoured with galvanised steel strip or wire, heavy duty HT underground cable ISI marked with aluminium multistranded conductor 11000 volts grade of size 95 sqmm 3 core laid in trenches/duct passing through pipe/duct or fixed on pole and connecting and testing complete.
M &L for replacement of straight through joint ( Epoxy joint) for LT U/G cable of following sizes complete with jointing material :- (a) 2 core 16 sqmm to 35 sqmm or 3 core 16 to 25 or 4 core 10 to 16 Sqmm.
All as per item no 38 above but suitable for (b) 50 Sqmm 3.5 core cable.
All as per item no 38 above but suitable for (c) 70 Sqmm to 95 Sqmm 3.5 core cable.
All as per item no 38 above but suitable for (c) 120 Sqmm to 150 Sqmm 3.5 core cable.
All as per item no 38 above but suitable for (c) 185 Sqmm to 240 Sqmm 3.5 core cable.
All as per item no 38 above but suitable for (c) 300 Sqmm to 400 Sqmm 3.5 core cable.
All as per item No 38 above but for 11 KV straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm.
All as per item No 38 above but for 11 KV end termination jointing kit indoor heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm 3.5 core.
All as per item No 38 above but for 11 KV end termination jointing kit indoor heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm 3.5 core.
Supply & fix in repair double compression stainless steel gland for fixing armoured cable in existing panel of size 2 core 6 Sqmm to 16 Sqmm.
Supply & fix in repair double compression stainless steel gland for fixing armoured cable in existing panel of size 4 core 6 Sqmm to 16 Sqmm.
Supply & fix in repair double compression stainless steel gland for fixing armoured cable in existing panel of size 3.5/4 core 25 Sqmm to 35 Sqmm.
Supply & fix in repair double compression stainless steel gland for fixing armoured cable in existing panel of size 3.5/4 core 50 Sqmm to 70 Sqmm.
Supply & fix in repair double compression stainless steel gland for fixing armoured cable in existing panel of size 3.5 core 95 Sqmm to 120 Sqmm.
Supply & fix in repair double compression stainless steel gland for fixing armoured cable in existing panel of size 3.5 core 150 Sqmm to 185 Sqmm.
Supply & fix in repair double compression stainless steel gland for fixing armoured cable in existing panel of size 3.5 core 240 Sqmm to 300 Sqmm.
S & F in repair of weather proof bus bar chamber of suitable size made out of 3mm thick CRCA sheet (out door type) and 40 x 5mm angle iron frame with locking arrangement including provision of 04 Nos of 600mm long Aluminium bus bars of 600 Amps rated capacity mounted on insulated frames including connecting up incoming and out going cables complete with glands and lugs and chamber to be painted with two coats of aluminum paint over a coat of red oxide primer including mounting the chamber on suitable size of bolts, nuts including taking down existing unserviceable chamber of any description all as specified and directed.
Note :- (a) Quoted rate includes excavation, earth work and PCC work and connection complete. (b) Bus bar chamber should be grout properly above 1.2 mtr from ground level. Angle iron and PCC work reqd for the same is included in the rate quoted.
Disconnecting existing LT Panel & raising the panel of any size by providing angle iron of suitable size /PCC up to the height of 1.2 mtr from ground level and re- connection complete duly welding work & painting work of LT Panel as per existing colour complete all as directed by Engr-in-charge. Note :- Disconnecting and re-connecting of LT Cables as per direction of JE/Engr-in-charge is included in the rate quoted.
Disconnecting existing HT cable and LT cable from existing Transformer of any capacity and keeping aside for re-use. Raising the existing platform up to the height of 1.2 mtr. Re-locating the same transformer on raised platform and connecting complete all as directed by Engr-in-charge.
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation / fixing of pole / laying of cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil all as specified.
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation (Laying of under ground cables and PCC pole) in Hard/dense soil and getting out all as directed.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as directed
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose any punned thickness of sand will be considered.
Taking out old PCC cable cover of any type / any size from trenches all as specified and directed.
Laying only PCC cable cover for HT / LT UG cable, of any description retrieved from item No 21, all as specified and directed by Engr-in-Charge.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , flat of size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed by Engr-in-Charge
Laying of LT/CCR cable of any size any make all as per directed by CCr-in-charge. Note :- (i) Re-Routing of CCR Cable will be done under the guidance of concerned rep of CCR. (ii) Accessories required for rectification of CCR Cable/New cable will be directed by CCR Department.
Supply and laying GI tubing 40mm dia medium grade laid in trenches/floor/fixing on pole/wall/in tarmac including necessary fittings etc complete all as specified and directed.
Supply and laying GI tubing 25mm dia medium grade laid in trenches/floor/fixing on pole/wall/in tarmac including necessary fittings etc complete all as specified and directed.
Supply and laying GI tubing 40mm dia light grade laid in trenches/floor/fixing on pole/wall/in tarmac including necessary fittings etc complete all as specified and directed.
Supply and laying GI tubing 100mm dia light grade laid in trenches/floor/fixing on pole/wall/in tarmac including necessary fittings etc complete all as specified and directed.
M & L for Boring of holes under road pavement,, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure etc complete all as specified and directed. Note :- Necessary infrastructure reqd for Boring shall be arrange by the Contractor at his own cost.
Supply and installed voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V without voltage stabilized at 230V with accuracy of (+,-) 2.5 % and capacity 5 KVA
S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 20 Amp MCB SP, Legrand cat part No : 607841 or equivalent of Havell's , Schneider etc
Supply and fix MCB single pole 20 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. Make- C & S Cat No. CSMBS1C20 / ABB/ L& T
Supply, installing, testing and commissioining factory made CPRI approved outdoor type LT Panel board compartmental type confirming to IS-5039 with IP-53 made out of 3.15mm thick CRCA sheet , 415V, 3 Phase, 50 Hz supply mounted on and including MS angle with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable fro accommodate and including the following mentioned fittings, floor mounted with PCC 1:2:4 type B1 platform, nut bolts, washers etcfor grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer.The LT Panel should comprising the following:-
following:- (i) Aluminium Bus bar chamber consisting of four Nos aluminium bus bar duly sleeves of capacity of 600 Amps for phases and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in seperate compartment. (ii) Multifunctional digital type meter showing ampere, voltage PF phase to phase & phase to neutral . Make :- Secure/conserve/Legrand. (iii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(Make:-Siemens/L&T/Telematic) (iv) Panel board internal wiring with suitable rated PVC insulated copper conductors.
(a) On load change over switch 250 Amps,415V, 4 Pole, 50 Hz, - 01 No (In coming)
(b) MCCB 250 Amps,415V, 4 Pole, 50 Hz, 35 KA with adjustable and thermal magnetic setting - 01 No (In coming)
(c) MCCB 200 Amps, 415V, 4 pole, 25 KA with adjustable and thermal magnetic setting - 01 Nos
(d) MCCB 100 Amps, 415V, 4 Pole, 16 KA with adjustable and thermal magnetic setting - 01 Nos
(e) Voltmeter digital type - 01 Nos
(f) Ammeter digital type with suitable sizes of CT's - 01 Set
Note :- (i) Quoted rates shall be deemed to include for grouting/fixing of panel in PCC 1:3:6 type C2 and PCC Block masonry with PCC Block of mix 1:5:6 & plastering 10mm thick in CM 1:6 and panel height upto 1.2 mtr above ground level complete all as specified and directed by Engr-in-Charge.
(ii) Make :- Havells/L&T/Legrand or any CPRI approved
Material and labour for installation, testing and commissioning of earthing using following material including necessary T&P required to complete job for earthing, excavation etc. Make:- Powertrac Model No-PT-803 or equivalent of make PRAGATI/ McML's Earthing Solution (MES)/ Ashlock (a) 'CHEMO' M.F. Earthing Electrode (conforming to IS 3043:1987) of copper, 3.00 metre long, 80 mm outer dia, copper inner strip of size 50 x 6 mm thick, pipe filled with SRIP compound (50 kg per earthing electrode)
(b) FRP based earthing display board with support stand FRP coated width-254 mm, length-380mm, height-610 mm (c) PCC earthing protection chamber for each earthing pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 kg/sqm) Note:- (i) Earthwork in any type of soil, installation of complete earthing system will be carried out in presence of company's authorised tradesmen/ representative.
(ii) Item rate quoted by contractor shall include for 250 mm dia bore upto 3 metre deep and pouring, mixing of SRIP compound with soil. (iii) Drawing for single bore earthing is enclosed. (d) The earthing result will be obtained for each electrode must be less than 3Ω. Otherwise contractor is liable to do chemical earthing to meet the result without extra cost if the results are above 3Ω.
(e) Contractor must visit the site before quoting the tender to understand the difficulty and cost for carrying out the job in the station. It is important that contactor ascertain the quantum of work. (f) Contractor must produce the certificate from the manufacturer that chemical earthing has been carried out by manufacturer. The manufacturer must also mention the warranty for chemical earthing. (g) Extension strip from electrode strip upto 0.15 m height from GL to be deemed included in quoted rate including brazing (h) The contractor has to give in writing for 3 years minimum warranty for constant result of earth below 1Ω.
Cutting existing GI Pipe of dia 50/40mm and inserting tee, bend etc as per requirement for branch connection all as directed by Engr-in-charge.
Supply and Fixing Gun Metal Gate Valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 25mm bore.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32/6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
M & L for Earthing complete with copper earth strip of size 20 x 3mm copper strip and copper plate of 60 x 60 x 3.15mm as earth electrode., buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to dolly earth by means of bolts, nuts, check nuts and washers of copper or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
Note :- (For Ser No 78 & 79) Earth work is including exc & earth work in any type of soil, disposal of soil, providing alternate layer of charcoal and common salt, construction of pcc earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed at site. Note : Main earth strip beyond 7.5 meter shall be measured and paid separately.
Supply, installing, testing and commisioning of LT cubical panel board 440 volts , 50 Hz , 3 phase , 4 wire , out door type weather, vermin, dust proof, front operated with adequate air ventilation at sides and back fabricated out of 3.5 mm thick CRCA sheet with double door shutter and locking arrangements cables trays cable lugs etc.including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger board etc , suitable to accomodate and including the following mentioned fittings , floor mounted with PCC 1:2:4, type B1 platform of 50 cm height suitable nut bolts, washer etc. for grouting , and painting with power coated epoxy finish of approved colour over a coat of .....
...........red oxide primer including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:- (i) Bus bar chamber consisting of four Nos copper bus bars duly sleeved of capacity of 315/320 Amps for phases and 300 Amps for neutral. Duly insulated with PVC sleeves RYB , mounted on heavy duty epoxy insulation in separate compartment. (ii) Multi functional digital type meter showing ampere , voltage PF phase to phase & phase to neutral . Make : secure /conserve/legrand (iii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches . (make: siemen/L&T / Telematic)
(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. Note:- The LT panel board shall be made to suitable size to accommodate the following fittings and Rate included Excavation, earth work and pcc work and complete all connected work (i) MCCB 320 Amps 4 pole 35 kA - 1 No (in coming) (ii) ON Load Changeover switch 315/320 Amps , FP, 415 v, 50 Hz -01 (iii) MCCB 160 Amps 4 pole 25 kA - 2 Nos (Out going) (iv) MCCB 123 Amps 4 pole 25 kA - 2 Nos (Out going)
M &L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level, connected to galvanised earth strip, 32/6 mm by means of bolts, nuts, check nuts and washers of galvanised iron of steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4, type B1 for precast chamber cover 50mm thick, reinforced with welded steel wire fabric or XPM Jail (weight not less than 4.. Kg/Sqm), with charcoal, salt, funnel plate No.03 of SSR part - I and testing on completion.
Note :- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps compete all as specified and directed at site.
S&F Sheet metal enclosure (CRCA sheet) dust and vermin proof ,fixed with MCCB 125 Amps, 25 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (-10 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:- (i) Refrigerent - R 410a (non CFC) (ii) EER - min 3.5 (iii) Tonnage - 2.0 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter
(vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make: Carrier/ Hitachi/O general
Voltage stabilizer of automatic operation single space naturally air cooled indoor type and designed for following features Make: V guard/ Microtek/Sukam (a) Capacity : - 5 KVA (b) Working Voltage Range - 130 V-280V AC (c) Salient features :- (i)Intelligent time delay system 3 min (ii)Compatible with regular and inverter AC (iii)Wall mounting cabinet design (iv)Low and high voltage cut off (v)Digital display
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (-10 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:- (i) Refrigerent - R 410a (non CFC) (ii) EER - min 3.5 w/w (iii) Tonnage - 1.5 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter
(vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make: Carrier/ Hitachi/Daikin
Note:- Following will be inclusive in rate:- (a) Piping length up to 15 mtr will be inclusive in item (b) Installation will include fixing the outdoor unit on the platform as per direction of Engineer in Charge (c) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge
(e) Contractor will provide warranty of 5 years for compressor from the date of installation (f) 5% of Air conditioner will be tested by the Garrison Engineer for Energy Efficiency and all the functions provision in the Air conditioner (g) Contractor provide complete free service in warranty period by the company
Voltage stabilizer of automatic operation single space naturally air cooled indoor type and designed for following features Make: V guard/ Daikin/ Bluestar (a) Capacity : - 4 KVA (b) Working Voltage Range - 130 V-280V AC (c) Salient features :- (i)Intelligent time delay system 3 min (ii)Compatible with regular and inverter AC (iii)Wall mounting cabinet design (iv)Low and high voltage cut off (v)Digital display
M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 4 Sqmm drawn through in and including Non metallic PVC casing capping on wall / ceiling with all accessories with 4.0 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note: Three runs of 4.0 sqmm copper cable including PVC casing capping will be measured as one RM.
S & F in metal clad plug & socket board Single pole and neutral enclosure with 2 pole and earth metal plug & socket complete with 20 Amp MCB SP, C curve complete all as specified and as directed by Engr-in-Charge. Make- Anchor/Legrand/L&T
Supply & lay PVC inner shealthed armoured cable electric power cable heavy duty 1100 volts grade with standard copper conductor of size 6 Sqmm 4 core. Completed all as specified and directed by Engg-in-Charge.
Supply & Fix MCCB 200 Amps, 35 KA, including metal box completed all as specified and directed by Engg-in-Charge.
Supply & Fix MCCB 400 Amps, 35 KA, including metal box completed all as specified and directed by Engg-in-Charge.
suvidhiconstruction
Sagathiya Builders
EVEREST BUILDERS
Vijay Construction Co
jitendra c joisar
High Tech Consruction
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .