Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC 673636 | MALAPPURAM | KERALA | 673636 | ₹2.3 L | L1 | Accepted-AOC lowest1 |
| 2 | L2₹2.3 LRejected-Finance NADUVILPAT HOUSE KALLARAMANGALAM PO VIJAY ENGINEERING KADAMPUZHA MALAPPURAM PIN 676553 | MALAPPURAM | KERALA | 676553 | ₹2.3 L | L2 | Rejected-Finance LOWEST2 |
Tender Value
₹3.0 L
EMD Value
₹7,425
Closing Date
11 Jan 2024, 5:00 pmClosed
SECRETARY,TANALUR GP
SECRETARY,TANALUR GRAMA PANCHAYATH
Puthantheru market Take a break public toilet Electrification S0211/24 General Electrical Work
2024_DP_639463_1
Ten-1/01/2023-24/secretarytnlr
Open Tender
Electrical Works
Item Rate
TANALUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹655
Yes
₹7,425
Yes
18 Mar 2024
3 Jan 2024
15 Jan 2024
3 Jan 2024
11 Jan 2024
3 Jan 2024
Amount
Electrical
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD107463/2023-2024:Supply and fixing 12W LED bulk head fitting heat resistant prismatic glass cover to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
OD107464/2023-2024:Supply Conveyance, installation, testing and commissioning of 20W LED Flood light with IP 65 protection LED Chip make acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenanc
OD107465/2023-2024:Supply, installation testing and commissioning exhaust fan of size 150mm or nearest size sweep Light duty with self opening lowers in the existing opening/including making holes if required, fixing necessary anchor bolts/bolt and nut with 0.3m,110mm PVC pipe neatly plastered in the existing exhaust fan hole, making good the damages, color washing etc as required and giving connection with required length of 24/0.20mm PVC insulted and PVC Sheathed 650/1100V grade 3 core round copper conductor flexible wire
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD107509/2023-2024:Supply, Conveyance, installation, testing and commissioning of 400mm sweep wall mounting fan with metallic blades, blade covers,body,mounting brackets etc with Almonard,Orient,Havels or equivalent make
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD107467/2023-2024:Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
OD107468/2023-2024:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD107469/2023-2024:Supply and providing 25x6mm brass nut and bolt etc. as required.
OD107470/2023-2024:41 1 each OD Supply and providing and fixing switch disconnector fuse unit (Panel mounting Cubicle type) 32 amps. double pole, AC 23A, 50Hz , 415V with ISI marked HRC fuses on wall/angle iron frame including drilling holes in frame, making connections, etc. as required.
OD107471/2023-2024:Supply & installation of dust and vermin proof, 1 Phase Syntax Meter Board GS-MB-3425-STD-NF and to fix KSEB meters, fuse units, CT etc and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required.
OD107472/2023-2024:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD107473/2023-2024:Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board
OD296334/2023-2024:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall /ground and making good the same in case of recessed conduit as required.32 mm
1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD108503/2023-2024:Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including making trench refilling etc and making good the same in case of recessed conduit as required.50 mm 10 kg/cm2 ISI marked
OD107555/2023-2024:Supply and installation testing and commissioning of 2 HP Horzondal open well submerssible motor pump set 2850 RPM at rated voltage single phase 220/240V, 50 Hz, AC supply conforms to IS 8034 head 21 54 M 2 HP CSS 4S (4STAGES) CRI Makle or similler make Deccan pump set with all systems and standard size delivery pipe as company';s make connected one by one to the motor up to the bottom of the well using leak proof materials with required lengt of rope as required with necessary GI bracket support on top sides of the motor including giving connection as per the direction at site
OD107559/2023-2024:Supply and providing 50 mm or nearest size dia Flange set
OD107601/2023-2024:Supply and fixing flat iron clamps made from 2 nos. 50x6 mm flat iron clamp of 50 mm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required
OD107602/2023-2024:Supply threading, laying and joining of 32 mm or nearest size Column Pipe for Submersible Pumps Approved make specials as delivery pipe using required leak proofing materials etc. as required.
OD107608/2023-2024:Supply and providing 32 mm stainless steel Hose Collar with hose clip
OD107611/2023-2024:Supply and providing 32 mm dia or nearest size G.M Non return valve (ISI)
OD107616/2023-2024:Supply and fixing 32 mm dia or nearest size Full way valve
OD107474/2023-2024: Charges for preperation of KSEB test Report for submitting to the concerned KSEB section office
RAJESH R
Bidder Name
RAJESH R
GOPAKUMAR A C
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_973901.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].