Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.1 L−₹39,704 (4.68%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical KALLANKODAN HOUSE VAKARI PO SULTHAN BATHERY WAYANAD PIN 673 592 | SULTHAN BATHERY | WAYANAD | KERALA | 673592 | - | Rejected-Technical L4 | |
| 4 | Rejected-Technical PUTHANVEETTIL HOUSE KUPPADI | - | Rejected-Technical L5 | |
| 5 | Rejected-Technical | - | Rejected-Technical L3 |
Tender Value
₹8.9 L
EMD Value
₹15,000
Closing Date
7 Feb 2022, 5:00 pmClosed
Executive Engineer
Executive Engineer,LID EW Division , Kalpetta
DP WAYANAD 2021-22 - P.NO -594-MUNDAKOLLY CHEERAL FHC ROAD CULVERT CONSTRUCTION- NENMENI GP - RS. 10 LAKHS
2022_LSGD_470986_16
EE/LIDEW/WYD/12/2021-2022
Open Tender
Civil Works - Roads
Item Rate
150 days
Kalpetta
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,360
Yes
₹15,000
Yes
20 Apr 2022
29 Jan 2022
10 Feb 2022
29 Jan 2022
7 Feb 2022
29 Jan 2022
Amount
Road culvert
11.1.1.1 : Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I.Ordinary soil (i)Upto 3 m depth
od1563800/2021_2022 : DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
od1563678/2021_2022 : Providing concrete for plain/reinforced concrete in open foundations (WITHOUT FORMWORK) complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (11.4.1.1 Modified)P.C.C grade M 10, Nominal mix 1:3:6
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I.P.C.C grade M 10 (i)Nominal mix 1:3:6
12.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 m I.P.C.C grade M 15 (i)Nominal mix (1:2.5:5)
12.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
12.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 m III.R.C.C grade M 20
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
od1563679/2021_2022 : Filling with contractor's own earth ( excluding rock) in OPEN AREAS in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
od1563877/2021_2022 : Filling with Quarry Muck<br>Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
od1563680/2021_2022 : Pumping or Bailing out water and removing slush etc by using Pump set including cost of labour, oil, hire charges of pump set etc complete
od1563682/2021_2022 : Providing and fixing NAME BOARD fixed over MS sheeting, 2 mm thick supported on<br>GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade<br>cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical<br>Specification Clause 1701.600 mm x 450 mm Rectangular
Dismantling damaged culvert
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
SIVARAJAN P R
K K SAIDALAVI
SULTHAN BATHERY LABOUR CONTRACT AND CONSTRACTION CO OP SOCITY
T V JOHNY
Bidder Name
K K SAIDALAVI
SIVARAJAN P R
T V JOHNY
RAJAN K R
SULTHAN BATHERY LABOUR CONTRACT AND CONSTRACTION CO OP SOCITY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_675443.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .