| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC GOKUL APARTMENT PANJABIPARA DISTT JALPAIGURI SILIGURI 734401 WB | DARJEELING | WEST BENGAL | 734401 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹31.7 L+₹2,799.55 (0.09%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹35.8 L+₹4.1 L (12.9%)Rejected-Finance NIL | THE NILGIRIS | TAMIL NADU | 638451 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | Rejected-Technical 65 JOY NARAYAN BABU ANANDA DUTTA LANE HOWRAH 711101 | HOWRAH | WEST BENGAL | 711101 | - | Rejected-Technical NOT ELIGIBLE AS DOCUMENTS NOT UPLOAD AS REQUIRED IN NIT |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
9 Sept 2020, 6:00 pmClosed
Cwe Binnaguri
HQ CWE BINNAGURI
SPECIAL REPAIR TO BUILDING NO P-23 25 G-31 G-32 AND P-06 AT BINNAGURI MIL STN UNDER GE NORTH BINNAGURI
2020_MES_368806_1
8010/BIN(N) 27 of 2020-21
Open Tender
Civil Works
Item Rate
120 days
Binnaguri Mil Stn
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE NORTH BINNAGURI
₹76,000
Yes
29 Sept 2020
13 Aug 2020
10 Sept 2020
13 Aug 2020
9 Sept 2020
27 Aug 2020
Amount
Schedule 'A'
Taking down cement plaster on wall of any desription incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on facia, roof projection, chajja etc finished even & smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15mm thick in CM (1:6) on concrete/brick wall surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10 mm thick plaster rendering on fair faces of concrete surfaces as in ceiling in CM(1:3) finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) mixed with water proofing compound in top layer @3% by the weight of cement or as per manufacturer's instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note : Integral water proofing compund shall be measured and paid separtely.
Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed.
M&L for three coats of white wash on walls over newly plastered surfaces of wall incl preparation of surfaces etc complete all as specified and as directed.
All as per item No 7.00 here-in-above but 3 coat of white wash on ceiling complete all as specified and directed.
M&L for applying three coats of colour wash on newly plastered surfaces of wall including preparation complete all as specified and as directed.
M&L for two coats of acrylic emulsion paint (weather coat) over newly plastered surface of wall and necessary preparation of surfaces including a thick layer of wall putty complete all as specified and as directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing scrapping down to remove smooke soot moulds moss and efflorescene salts and treating oil and greasy spots etc and applying one coat of colour wash complete all as specified and as directed.
M&L for preparing old decorated plastered or unplastered surfaces of walls including cornices, pilasters and other wall features etc by brooming down or steel wire brushing scrapping down to remove smooke soot moulds moss and efflorescene salts and treating oil and greasy spots etc and applying one coat of white washing on the same all as complete all as specified and as directed.
All as per srl item No 12 herein above but on ceiling complete all as specified and directed.
M&L for one coat of applying acrylic emulsion paint (weather coat) over eixisting surfaces of wall,chajja,column etc and including necessary preparation of surfaces including wall putty/white cement whereever required to fill the wall cracks/holes complete all as specified and as directed.
Demolition of cement concerte (unreinforced) of any description in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L Machine cut kota stone slab in flooring 18 to 20 mm thick area of each tile exceeding 0.18sqm over and includuig 20mm thick cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
M&L for kota stone slab 18 to 20mm thick in riser or steps, skirting, dado and pillar laid over 10 mm thick screed bed cement screed (1:4) and jointed with grey cement slurry mixed with pigment to match the shade fo the slab including rubbing and polishing complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C-2 with using 40mm graded stone aggregates as in plinth protection laid in panels and finished even and fair including necessary form work complete all as specified and as directed. Note: Joints 12mm wide joints to full depth of PCC shall be provided at every 3 meters interval and at every change of direction and shall be filled with mixture of bitumen and sand in 1:3 by weight . Cost of provision shall be deemed to be included in quoted rate of this item.
M&L for Continuous brick edging; with width equal to the width of the brick; laid dry on end vertically with brunt clay bricks of sub class B old bricks complete as specified and as directed.
Dismentling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles, and rubbish off the premises complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding layer in CM (1:6) as in floor complete all as specified.
M&L Rendering 10mm thick in cement mortor in 1:4 on fair face of brick work in dado and skirting finish fare & even to receive tiles etc.complete as specified and as directed.
S&F for glazed ceramic colored/printed tiles size 350x400 mm thick as in vertical surfaces such as skirting dados & repairs to step etc. complete as specified and as directed.
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles complete as specified and as directed.
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles complete as specified and as directed.
S&F in repair steel window with side hung shutters with projecting type hinges, 3mm thick 100mm long copper oxidised finish mild steel handle and 3mm thick 300mm long mild steel copper oxidised finish peg stays and glazing bars, dovetailed or welded with applying one shop coat of red oxide zinc chromate primer before fixing including taking down old unserviceable steel windows form existing position and making good disturbed surfaces of walls etc in all respect as per existing specification all complete as specified and as directed.
S&F in repairs steel window with side hung shutter incl projecting hing with steel handle and steel peg stay complete without glazing bars, dovetailed or welded including taking down old unserviceable steel windows form existing position and making good disturbed surfaces of walls etc in all respect as per existing specification all complete as specified and as directed.
S&F in repair aluminum anodized louvered ventilators with 5.5mm thick glass louvers, without sash bars, of aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and with suitable locking arrangements incl taking down old complete all as specified and directed.
S&F Mild steel framed work such as grills, gratings, guard bar etc with ends of bars shouldered or riveted or for forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290. Gde -E- 165 complete all as specified and directed.
S&F Stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F of 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces any descrtiption over 10 Cm in width or girth not otherwise described and applying 2 coats of synthetic enamel paint all as specified and as directed.
Taking down chowkat or frame exc 1.5 sqm but n.exc 4 sqm with shutters (without taking taking off shutters from the frame) complete all as specified and directed.
M & L for framed work as in doors frame of angle or other section conforming to Fe 410-W(Gde-E- 250)quality-A with gusset plates, rails, braces, etc., and including fixing of steel hinges or other door fittings complete all as specified and directed. (door fittings like hinges, tower bolt etc shall be measured and paid seperately) complete all as specified and directed.
S & F flat iron clamps, hold fasts, wall ties, hooks for hanging fans and other similar small steel article confirming to Fe – 290 Grade – E 165 with and including necessary nut-bolts, washers, screws etc. as required complete all as specified and directed
S&F 35 mm thick Flush shutters, solid core, construction, with block board core and plywood face panels, commercial type on both sides with particle board core complete all as specified and as directed.
S&F 300mm long alluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or xtruded section and fixing bolts and sliding of extruded section complete all as specified and directed.
M&L for preparation of new wooden surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
Taking down PVC/AC soil pipe including fittings as in wall of any dia complete all as specified and as directed.
S&F 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
All as per item 40.00 here-in-abive but for 75 mm complete all as specified and directed.
S&F 110mm dia PVC bends of any radius with acess door complete all as specified and as directed.
S&F 110mm dia PVC (SWR) branch piece single (single 'Y') equal or unequal with acess door complete all as specified and directed.
S&F in repair 100mm dia PVC floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4), type B1 complete all as specified and as directed.
Taking up or down GI tubing 15mm bore pipe and connection including cleaning for refixing or removal from site as complete all as specified and directed.
Taking up or down GI tubing 20mm bore pipe and connection including cleaning for refixing or removal from site as complete all as specified and directed..
S & F 15mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S & F 20mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S & F in repair 15mm size PVC Connection with PTMT nut of length 450mm complete all as specified and as directed.
S&F in repairs vitreous china wash basin white flate back size 580x450mm incl 32mm waste chromium plated waste coupling and 32mm dia bore PVC waste pipe, including brackets complete all as specified and as directed.
S&F in repair pillar taps with heads, chromium plated, screwed down high pressure with or without lettered 'hot or cold' with long screwed shanks and flynuts screwed for iron pipe and fixed for 15mm complete all as specified and directed.
S&F in repairs Bib taps fancy type chromium plated for 15mm bore pipe, screwed down for iron pipes or for brass ferrule all complete as specified and as dierected.
Supply & fixed in repairs angular Stop valve (ISI Marked), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore and fixed in repair complete all as specified and directed.
Supply & fixed in repair, vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and as directed.
S&F in repairs urinal bowl type flat back size of 465x355x265mm white with grating and union for discharge pipe (EXCL flushing cistern flush pipe and waste pipe) complete all as specified and directed.
S&F in repair 10 ltr capacity PVC flushing cistern low level white colour incl PVC connection PVC flush pipe of reqd length CI brackets nin lieu of old unservisable push button flushing Cistern complete all as specified and directed.
Supply & fixed in repair, Auminium anodised tubular towel rail 20 mm dia, 'D' type 60 cm long between flanges complete all as specified and directed.
Supply & fixed in repairs Soap dish/tray, Stain less steel, fixed to plugs with CP brass screws complete all as specified and directed.
Supply & fixed in repairs PVC waste pipe with union, flexible suitable for wash hand basin or urinal, 32 mm dia complete all as specified and directed.
Taking down chowkat or frame n.exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Solid PVC door frame of size 50 X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, supplied and fixed in repair in opening as per specifications and drawing complete all as specified and directed.
Factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail, MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; Panelling of plain colur PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, Supplied and Fixed in the frame at site as per specification and drawings complete all as specified and directed.
S&F for Aluminium alloy anodised handle fabricated 150mm long complete all as specified and directed.
S&F for Aluminium alloy anodised barrel tower bolts 150 mm long complete all as specified and directed.
S&F 75 mm stainless steel butt hinges medium weight cold rolled mild steel complete all as specified and directed.
Demolition of cement concerte (reinforced) above ground floors and pavings n.exc 15 cm thickness complete all as specified and directed.
M&L for Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) of 100mm thk concrete slab,laid in bays with using necessary formwork and finished the surfaces even and fair, complete all as specified and directed.
M&L for Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ of 100mm thk concrete slab complete all as specified and directed.
Demolition of brick work built in cement mortar and removing from site complete all as specified and directed.
M&L brickwork with sub class B bricks straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6 by using old size bricks complete all as specified and directed.
Dismantling water tanks and removing to store of capacity n exc 500 including all fittings complete all as specified and directed.
S & F 500 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers etc complete all as specified and directed.
S&F 20mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut complete all as specified and directed.
S&F in repair for fixing over crumple joints of 0.63mm thickness Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
Taking down existing roof treatment(water proofing membrane etc) including screed bed complete from roof surfaces including parapets and lowering and removing the same to a distance exc. 50 m and n. exc. 100 m incl roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust, etc complete all as specified and as directed.
M&L for 15 mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying water proofing treatment with using WPC @ 3% by weight of cement complete all as specified and directed. Note : Integral water proofing compund shall be measured and paid separtely.
M&L for providing and applying single component acrylic polymer modified, fibre reinforced waterproof coating brushbond Roof Guard in 3 coats of application @ 0.5 litre /sqm coat, including sprinkling of clean sand (300 microns - particle size).The product should have following properties solid content : 70%, tensite strength (ASTM D 412): 1.10 MPs, elongation (ASTM D12) : 100% Resistance to ageing due to UV radiation . 1000 hours no change rapid chloride penetration : very low resistane to algae growth passes, zero rating / permeability (mm): 5.0 water vapour transmission : 6.0gm/sqm h No of coats : 3 (minimum) adhesive bond strength : > 0.92 N/mm2
M&L for removal of old decorative surfaces of walls including cornices, plasters and other wall features etc by washing rubbing down and stopping and applying one coat of oil bound distemper on the same with including a thick layer of wall putty / white cement wherever required to fill the wall craks / holes complete all as specified and as directed.
M&L for one coat of applying acrylic emulsion paint (weather coat) over existing surfaces of wall, chajja, column etc and including necessary preparation of surfaces including wall putty / white cement wherever required to fill the wall cracks / holes complete all as specified and as directed.
S&F of glazed ceramic coloured / printed tiles size 300x450x7mm thick as in vertical surfaces such as skirting dados & repairs to step etc set and jointed in neat cement slurry and pointed in white or cloured cemnt to match with the tiles complete all as specified and as directed.
M&L Non-skid ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles complete all as specified and as directed.
Dismentling wrought iron or mild steel work of any description not otherwise provided for roof trusses and purlins complete all as specified and as directed.
S&F of rolled mild steel sections as in roof trusses (framed) trussed, purlins, crane gantry, rails, fasteing, heavy bracket framing (Beam, tee, angle, chanel or flat section), including distance pieces, cleats etc, conforming to Fe-410-W including, welding & necessary fittings such as nut bolt, plate complete all as specified and as directed.
S&F in pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensitle strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins / spring clips complete all as specified and directed.
S&F in repair 15mm bore chromiu7m plated shower roses with arm (size of arm 195mm long with bend to 45 degree) complete all as specified and as directed.
S&F in repair fancy type chromium plate stop valves long shank and cup (concealed type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in iron pipe 15mm bore complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe) complete including provision of cement concrete bedding plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
All as per srl item No 63.00 here-in-above but partly glazed i.e upper panel will be wire mesh fitted externally in the clear space & lower panel will be poain colour PVC sheet complete all as specified and directed.
S&F harrison rails, 20mm dia mild steel, anodised alumium alloy with fixing brackets, stops rollers, decorative type side holder etc complete all as specified and as directed.
Dismentling existing PVC water tanks exc 500 ltrs and n.exc. 1000 ltrs complete all as specified and as directed.
S&F 1000 ltrs rotational moulded polyethelene water storage tanks (cylindrical vertical with closed top) incl connecting up pipes securing access covers etc complete all as specified and as directed.
S&F in repairs 25mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut complete all as specified and as directed.
M&L for repair of bath room out let pipe, rain water pipe mouth with the help of chemical component conbextar GP2 including PCC 1:2:4 (20mm graded aggregatye) as per manufacturer instructions complete all as specified and as directed.
M&L for prepare the wall and floor surfaces of sunken portion of toi9let and applying the water proofing materials BRUSH BOND RFX & NITO BOND BBX including PCC 1:2:4 (20mm graded aggregate) as per manufacturer instruction complete all as specified and as directed.
E&M Taking down carefully copper/alluminium any type of point wiring for one light, socket, fan, bell or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators, call bell etc removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surface of wall ceiling complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including MS sunk box, 3mm thick hylum sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and directed for the following :- One light point controlled by one way switch 5/6 amps.
(b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps complete all as specified and directed.
(c) One socket out let 5/6 amps point on the independent board complete all as specified and directed.
(d) One socket out let 5/6 amps point on the same board complete all as specified and directed.
All as per item No 101.00 here-in- above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed.
S&F in repair switch piano flush type 5/6 amps single pole one way all as specified. complete all as specified and directed.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed.
S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and directed..
S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed
S & F in repair deluxe fan Electronic regulator AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S & F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F in replacement of LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 double side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as specified and directed.
S&F inreplacement of LED street light luminaires 45/48 Watts IP 66 type with lens incl standard fittings pressure die cast aluminium housing with heat reistant toughened glass with lens housing with epoxy powder coated finsh and , complete with control gear box and all accessories duly prewired and connecting to ceiling Rose,and incl GI pipe 40 MM dia light grade bend to reqd shape , clamp, bolt, washers complete all as specified and as directed.
M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed. NOTE : (i) Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length.
M&L inreplacement for factory made sheet metal box made out of 2 mm thick MS sheet of Minimam size 350(B) X 400(H) X 200(D) mm with single door hinged shutter and locking arrangement for fixing MCCB with and including flashed / grouting on wall, painting with two coat of powder coated paint over a coat of red oxide primer and making good disturbed surfaces of walls with necessary cement work complete all as specified & directed.
S&F inreplacement of MCCB 4 pole, 415 Volts 25 KA breaking cap rating 100 Amps including all fixing accessories with both ends spreader links complete all as specified & directed. complete all as specified and directed.
S&F in replacement Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators with and including taking down old one complete all as specified and directed.
S&F in replacement MCB, Single pole & neutral,5 to 32 amps, 240 volts, ‘C’ curve, 10KA all complete as specified and as directed.
S&F in replacement MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed.
M&L in replacement for Earthing complete with galvanised steel plate electrode of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4 mm dia earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 15mm bore (Light grade) for building LT wall panel all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I 2009 including testing on completion all as specified and directed.
Supply,laying jointing & testing in trenches or passing through pipe, 1100 bolts grade,XLPE insulated,screened, PVC bedded,galvanised steelstrip or wire armoured LT electric power under ground cables heavy duty with aluminium conductor of cross sectional area 50 sq mm 3.5 core with all fixing & connecting accessories such as alluminium cable lugs,cablve gland,nut,bolts wassher etc all complete as specified and as ditected.
Supply,laying jointing & testing in trenches or passing through pipe, 1100 bolts grade,XLPE insulated,screened, PVC bedded,galvanised steelstrip or wire armoured LT electric power under ground cables heavy duty with aluminium conductor of cross sectional area 16 sq mm 2 core with all fixing & connecting accessories such as alluminium cable lugs,cablve gland,nut,bolts wassher etc all complete as specified and as ditected.
Excavation in trenches in soft/loose soil not exc 1.5 metre wide and not exc 1.5 mtr in depth and getting out for taking up /laying under groundelectric cable complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layer not exceeding 25 cms indepth complete all as specified and as directed
Removing surplus soil to a distance not exceeding 50 mtr and deposting where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed
Supply and lay dry river sand filling for under ground cable protection with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and as directed.
Supply and laying well burnt best quality locally available bricks of size 25x12.5x7.5cm (+-)10% tolerance laid flat for protection of UG cable complete all as specified and directed.
M&L 40 mm bore steel tubing light grade ISI Maked for protection of clabe laid in horizontal bore including necessary joints complete all as specifed and as ditected.
M&L for water heater 25 ltr capacity 230 volt 50 HZ complete incl fixing in wall with nuts, bolts etc, inlet/outlet PVC braided pipe, 15 mm dia chromium plate brass stop cock-02 nos and bib taps 15 mm dia 01 nos ccomplete all as specified and directed.
M&L for taking down carefully fan after disconncting electric connection and refixing with and incl carry out repair replacement of condensor,clamp with nuts & bolts, bearing ,greasing to the fan ,rewinding, paint with super enamelled white paint,writing MES No complete all as specified and directed.
S&F of Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver with and including opening of the wall should be 25mm more than the sweep diameter complete all as specified and directed.
M&L for LED retrofit Lamp 1x12 Watt (white) 230V B-22 holder base with polycarbonate body and aluminium heat sink complete all as specified and directed.
Supply and fixing of Sheet metal enclosures with socket two pin and earth plug top and MCB SP-20Amp 230 volt including taking down the old one complete all as specified and directed.
M&L for sub main wiring with 3 run of 10.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed. NOTE : (i) Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length.
Supply and hanging of Ceiling Fan 1200mm sweep, aluminium body, aluminium blades with metalic finish,230V AC 50 HZ with and including electric connection using 3 core flexible copper conductor cable from connector block to ceiling rose complete with all accessories all as specified and directed.
S&F of Exhaust fans AC single phase 230/ 240 V of size 380 mm sweep with louver with and including opening of the wall should be 25mm more than the sweep diameter complete all as specified and directed.
M/S. JAGDISH PRASAD AGARWALA
SG ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .