Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹73.5 LAccepted-AOC GREAT SPORTSTECH LIMITED PUNJAB SPORTS UNIVERSITY PHASE 2 PATIALA | PATIALA | PUNJAB | 140401 | ₹73.5 L Quoted ₹93.7 L | 1 | Accepted-AOC Work Awarded |
Tender Value
₹70 L
EMD Value
₹50,000
Closing Date
13 Nov 2025, 12:00 pmClosed
Chairperson and Managing Director
ASAP Kerala, Kinfra Film and Video Park, Sainik School PO, 695585
Construction of Sevens Football Turf and Allied Building at Chavara, Kollam, Kerala
2025_ASAPK_817816_1
ASAPHQ/677/2025-FUND
Open Tender
Civil Works - Others
Chavara
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,500
Yes
₹50,000
Yes
7 Jan 2026
31 Oct 2025
14 Nov 2025
31 Oct 2025
13 Nov 2025
31 Oct 2025
Amount
Turf Civil
2.32 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with available earth in open area in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering and rolling every layer and top most layer with power roller of minimum 8 tonnes, for all leads including all lifts involved as per the direction of Engineer in charge
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.2.1 Solid masonry block using precast solid blocks (Factory made) of size 30x20x15 cm or nearest available size conforming to IS 2185 part 1 of 1979 for super structure upto two floor level with thickness 15 cm in CM 1:6
Steel work for fencing with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Steel work with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers, along with latch system etc. complete For Gate and light fixture in turf.
10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. For fixing GI pipes to foundation. M20 J Bolt - 400mm & Plate 220x220x12mm
Applying priming coat: marine epoxy primer of approved brand and manufacture and finishing with PU paint (one or more coat) on steel galvanised iron/ steel works including all material and labour charges, etc. complete.
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Supply and Installation of approved quality 2mm thick UV Stabilized Nylon net of Mesh size not greater than 50mm in existing GI poles including all charges as per the direction of Engineer in charge. For covering sides and top.
Providing and fixing PVC pipes with 5 mm dia perforations, minimum 125 perforations per running metre, in trenches at required slope, as per specifications etc complete including the cost of all materials, labour etc. and as directed by the Engineer-in-charge. The rate includes cost of all materials, covering the pipe with Geo Textile Cloth, labour charges for trenching and carriage of surplus earth to a lead of 50m etc complete. including jointing of pipes with one step PVC solvent cement etc complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2.
Providing ,Laying, spreading and compacting stone aggregate of specified size 20mm downgraded metal as filter media around the drainage pipes in the sides of trench as per the directions of Engineer-in- charge. Rate inclusive of all materials,transportation and labour charges complete. The work has to be executed as per detailed specifications, and or as approved by Engineer-in charge.<br>Quantity measured based on the stack measurement and the stack shall be of standard dimensions.
Providing , laying and spreading of compacted fill with 40mm metal (Coarse Rubble Granite Stone) combined with a downgraded stone up to 30mm to form a contour and elevations in uniform thickness,rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, as per Drawings.Rate inclusive of all materials, transportation and labour charges complete.The work has to be completed as per detailed specifications and or as approved by Engineer-in- charge.<br>Quantity measured based on the stack measurement and the stack shall be of standard dimensions.
Providing ,laying and spreading of compacted fill with 20mm metal (Coarse Rubble Granite Stone) to form a contour and elevations in uniform thickness, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, as per Drawings.Rate inclusive of all materials, transportation and labour charges complete.The work has to be completed as per detailed specifications and or as approved by Engineer- in-charge.<br>Quantity measured based on the stack measurement and the stack shall be of standard dimensions.
Providing ,laying and spreading of compacted fill with 6mm metal (Coarse Rubble Granite Stone) to form a contour and elevations in uniform thickness, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, as per Drawings.Rate inclusive of all materials,transportation and labour charges complete.The work has to be completed as per detailed specifications and or as approved by Engineer- in-charge<br>Quantity measured based on the stack measurement and the stack shall be of standard dimensions.
Supply and Installation of Fixed type 7's Football Goal Post (3.65m x 1.80m x 1.20m) made of pipe 10cm dia G.I. pipe with 3.5mm thick UV Stabilized Nylon net of Mesh size not greater than 100 mm as per the direction of Engineer in Charge.
Supply and Installation of FIFA approved quality Synthetic Football Turf of Pile height 50 mm with PU backing (Not punched hole), Stabilizing infill of Quartz sand 30 kg/sqm and Performance infill Black SBR Rubber 8 kg/sqm as per the direction of officer in charge. A test certificate of compliance to FIFA specification is mandatory during physical inspection at site along with test report on material. Design, receive material, installation, testing and commissioning of synthetic surface for football including, laying, jointing, fixing in position to sub base, including all according to methodology and drawings and specifications, approved by FIFA including installation of inlaid white turf line markings to FIFA specification all complete. The complete installation should be to FIFA approved international standards.
Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)3. 25 to below 35 flush capacity
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 110 mm dia 4 Kgf/cm2
Pathway around turf
16.68 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Supplying, transporting, and installing stone benches (3 seater standard type) at the designated locations around the turf area, including all materials, labour, handling, loading, unloading, placing in position, and finishing complete as directed by the Engineer-in-Charge.
Signage
MR. Supply and installation of Signage- ACP BAse Acrylic 2D letter board having side projection of 2.5 inch with LED lighting of size 95 ft x 3 ft and supported on GI pipe pole not less than 50mm dia, firmly ifxed to the ground by means of properly designed concrete 45x 45 x 60 cm, 60 cm below ground level
Electrical
1.21.1-Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20mm
1.21.2-Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25mm
1.14.3-Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
90.6.5.12- Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes-3 core 2.50 sq mm
Supply Conveyance, installation, testing and commissioning of 200W LED Flood light greater than 120lumen/W 4000-6000 K with IP 66 protection with power factor greater than 0.95 at full load, internal surge protection up to 4 KV, External surge protection of 10 KV and Aluminium pressure die-cast Powder coated housing, toughfened / Acrylic glass cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duty wired up for use on 230 V AC supply, with driver, luminary and surge protection of the same OEM, Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer).
Supply and installation of IP 67 connector for power connection for installation of light fitting
Supply of following Light/Fan fixtures complete with accessories. Rate shall include necessary mounting bracket, suspension chains etc. energy saving 48W or nearest watts LED STREET LIGHT MADE OF PRESSURE DIE CAST ALUMINIUM housing lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP66 protection and impact resistance of IK07.Suitable for pole dia 45mm maximum. 5000K or nearest.
Supply, fabrication, installation, testing, and commissioning of a single arm bracket for mounting outdoor luminaires on a pole. The bracket shall be fabricated from 40mm Nominal Bore (NB), 'B' Class Galvanized Iron (GI) pipe, extending approximately 1.0 meter from the pole face, complete with a welded base plate for mounting. Securely fixing the luminaire (luminaire supply is in a separate item) onto the bracket. Providing electrical connections from the pole's junction box to the luminaire terminal using 3 Core x 2.5 Sq.mm FRLS insulated, multi-strand, flexible round copper cable run through the bracket arm. All necessary GI nuts, bolts, washers, cable glands, lugs, and clamps for a complete, secure, and weatherproof installation etc complete
1.7.2-Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required-2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. - 4 X 16 sq. mm (28mm)
9.1.1-Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.- 2 X 6 sq. mm (19mm)
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 1.50 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required-4 core 6 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required-4 core 6 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required-4 core 16 sq mm with factory made clamp.
OD-Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation- 50/38 mm or nearest size
Providing of maintenance free Earthing system which comprises of:Molecularly bonded copper of 99.9% purity on low carbon steel of minimum 1250mm length, with a diameter of 12mm as per UL 467.Earth enhancing mineral compound to improve soil conductivity. The material must be mineral inert to the sub-soil, not pollute the environment, and be non-corrosive to the earth rod. It should have a resistivity of less than 0.2 Ωm, be free from hazardous substances, and have a minimum of 3 Kg of the total composite. A test certificate from a government-approved Indian lab is required for the chemically inert compound.An FRP Earth electrode inspection chamber with a weight-bearing capacity of 60KN and dimensions of 290mm x 290mm x 209mm. A government-approved Indian labs test certificate is also required for this.
OD-Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm (10 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
Supply and fixing SINTEX Box (240mmx130mmx110mm) or nearest size including MCB Rail or Connectors for giving connections including all accessories complete as required
Supply, installation, testing and commissioning of Thermoplastic Enclosure IP65 & IK08 Feeder Pillar. Incoming: >> 32A TPN SFU with Fuse Link >> Three phase energy meter Direct mounting 10-40A Class:1 >> INCOMER: 1 40A FP MCB-1 NOS 2 63A FUSE BASE-3 NOS 3 40A HRC FUSE-3 NOS 4 PROVISION FOR 3PHASE ENERGY METER WITHOUT CT-1 NOS PROVISION ONLY 5 NEUTRAL LINK-1 NOS OUTGOINGS: 1 32A TP MCB-1 NOS 2 20A TP MCB-2 NOS 3 16A SP MCB-6 NOS Note:- >> MS Powder Coated Canopy Considered. Dimension: (1350(H) x 800(L) x 424(D))mm. Mounting Type: Floor.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_1370356.xls
BOQ • 0.40 MB
RFP.pdf
Tender Documents • 0.88 MB
Download all tender documents and submit your bid