Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC CHARUVILA PUTHEN VEEDU KOTTUKAL NELLIMOODU P O TRIVANDRUM 695524 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695524 | L1 | Accepted-AOC Agreement executed by SURESH T on 25.09.2023 | |
| 2 | L2₹3.5 L+₹4,344.04 (1.26%)Rejected-AOC THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L2 | Rejected-AOC Agreement executed by SURESH T on 25.09.2023, hence 2nd lowest EMD may be released | |
| 3 | Rejected-Technical BETHAL THIRUMALA TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695001 | - | Rejected-Technical L3 |
Tender Value
₹4.6 L
EMD Value
₹11,700
Closing Date
22 Jun 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer Thiruvananthapuram Corporation 695033
Provding Lighting at Jalasakthi Park in Chanthavila ward.
2023_LSGD_581852_2
EE(N)/OWNFUND TENDER/2023-24 (04)
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
₹11,700
Yes
14 Nov 2023
15 Jun 2023
24 Jun 2023
15 Jun 2023
22 Jun 2023
15 Jun 2023
Amount
90.3.17.3Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe
90.15.1.1Supply installation testing and commissioning of Octogaonal Pole made of hot dipgalvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mmbase plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 PartIII fixed head frame including round arm luminary carriage suitable to install 4/6 nosluminaries in symmetrical arrangement including connector foundation bolt 4 nosexisting RCC foundation and junction box etc, complete 8 Meters
90.15.4.7Supply Conveyance, installation, testing and commissioning of 100W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer)
OD356626/2022-2023 SupplyandfixingofSintexmakejunctionboxofsize140mmx140mmx95mmwithconnectorsuitable forterminating pole lighting.
90.6.5.12Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conformingto IS 694 part I 1960 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.3 core 2.50 sq mm
1.10.1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulatedcopper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copperconductor single core cable etc as required.Group A
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
MR Supply and providing the following types and power rated lamps in the existing fittings as required B22LED bulb 10 W
90.12.5.39Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
1.17.30Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x6 sq. mm
1.21.3Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm
1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.6 pin 15/16 amp socket outlet
1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. asrequired.Single pole
2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.40 amps
MRSupply and fixing Astrononical time switch suitable for 1 output per phase and suitable for single phasesupply including necessary connections as required.
5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired.
90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor orwall mounting, dust and vermin proof, cubicle type MV panel board comprising ofthe following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assemblyas per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approveddesign and requirement, with front and rear access facility, bus bar chambers, hingeddoors for all switch gear compartments, earthing the doors using 4 sq mm braidedcopper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamberand cable alley, powder coating the assembly after subjecting to 7 tank process etc asrequired. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted anglesetc shall not be used for the fabrication of panel assembly. The measurments will betaken the area of the complete sheets used for panel board including partitions,folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.5 Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board
90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.00 mm copper conductor ( 14SWG)
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.1 Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG)
OD356656/2022-2023 Supply and providing iron hook for binding service wire
OD356657/2022-2023 Supply and fixing 32A, 415 V, 2 way neutral link mounted on DMC/ SMC base inthe existing meter board and giving connections etc.
OD356658/2022-2023 Supply and fixing 32A backelite fuse base with HRC fuse link in the existing meterboard and givingconnections etc
14.1 Excavation for foundation in soft soil including dressing of sides and ramming ofbottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.10 Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
5.22.1 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelMild steel and Medium Tensilesteel bars
10.19 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
DIVIN SAM D S
STEPHEN MOSES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_859327.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .