Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 CrAdmitted-Finance | ₹10.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹12.4 CrAdmitted-Finance | ₹12.4 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SARASWATI CONSTRUCTION CO. L2 | JRA INFRASTRUCTURE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00Item Description | |||||
| 1.01 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, for all lead including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification. (1)By Mechanical Means (A) In area of non-thorny jungle | 8.85 | Hect | 24,000 ₹2.1 L | 15,000 ₹1.3 L |
| 1.02 | Preparation of Foundation for Embankment Scarifying the existing Bituminous road surface up to a depth of 150 mm and disposal of scarified material. | 1,125 | Sqm | 5 ₹5,625 | 5 ₹5,625 |
| 1.03 | Excavation in Soil using Hydraulic Excavator and Tippers with disposal Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location For all lead and lift as per Technical Specification | 16,606.15 | cum | 20 ₹3.3 L | 25 ₹4.2 L |
| 1.04 | Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted as per Technical Specification | 8,703.77 | cum | 40 ₹3.5 L | 40 ₹3.5 L |
| 1.05 | Construction of Subgrade and Earthen ShouldersConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement as per Technical Specification | 45,220.36 | cum | 80 ₹36.2 L | 60 ₹27.1 L |
| 1.06 | Granular Sub-base with Well Graded Material (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification for Grade I Material | 8,017.33 | cum | 900 ₹72.2 L | 800 ₹64.1 L |
| 1.07 | Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per and Technical Specification. By Mechanical Means | 8,047.39 | cum | 1,400 ₹1.1 Cr | 1,175 ₹94.6 L |
| 1.08 | Construction of Hard Shoulders by providing well-graded material G-II, spreading in uniform layers with motor grader on prepared surface, mixing by mix-in place method with rotavator at OMC and compacting smooth wheel roller to achive the desired density, complete as per Technical specification | 4,851.9 | cum | 500 ₹24.3 L | 350 ₹17.0 L |
| 1.09 | Prime Coat (II) Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification | 33,487 | sqm | 50 ₹16.7 L | 43 ₹14.4 L |
Tender Value
₹12.9 Cr
EMD Value
₹27.4 L
Closing Date
18 Mar 2021, 6:00 pmClosed
Executive Engineer Panchayat R and B Division
DPIU and Executive Engineer R and B P Division Patan
Widening and Strengthening of 1 Motipimpali Kolivada Rangpura Santhali to MDR Road 0/000 to 14/920 and 2 NH To Javantri Chalvada Road 0/000 to 9/350 Ta Radhanpur District Patan
2021_SRRDA_107971_1
GJ1804P3
Open Tender
Civil Works - Roads
335 days
Patan
Please refer Tender documents.
3 documents required · 3 mandatory
₹18,000
Executive Engineer Panchayat R and B Division
₹27.4 L
Gandhinagar
4 Jun 2021
12 Mar 2021
19 Mar 2021
12 Mar 2021
18 Mar 2021
12 Mar 2021
15 Mar 2021
Amount
Item Description
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, for all lead including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification. (1)By Mechanical Means (A) In area of non-thorny jungle
Preparation of Foundation for Embankment Scarifying the existing Bituminous road surface up to a depth of 150 mm and disposal of scarified material.
Excavation in Soil using Hydraulic Excavator and Tippers with disposal Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location For all lead and lift as per Technical Specification
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted as per Technical Specification
Construction of Subgrade and Earthen ShouldersConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement as per Technical Specification
Granular Sub-base with Well Graded Material (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification for Grade I Material
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per and Technical Specification. By Mechanical Means
Construction of Hard Shoulders by providing well-graded material G-II, spreading in uniform layers with motor grader on prepared surface, mixing by mix-in place method with rotavator at OMC and compacting smooth wheel roller to achive the desired density, complete as per Technical specification
Prime Coat (II) Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification
Tack Coat (i)Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification
Bituminous Macadam Providing and laying bituminous macadam (VG-30) with hot mix plant using crushed aggregrates of grading premixed with bituminous binder, trasported to site upto a lead of all laid over a previously prepared sufface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification 50mm thickness, Bitumen @ 3.3%
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates using penetration grade bitumen (VG30) to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of Type B as per Technical Specification By Mechanical Means 1.46 Kg per Sqm
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using , Type B (VG30) as per Technical Specification
Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type M30 (Grade), coarse a and find aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm., mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel) channel, laying and fixing of 125 micron thick polythene film, wedges steel plates including levelling the formwork as per drawing,) sprading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer sealant, dowel bars, near approaches to bridge/ culvert and construction joints, admixtures as approved, curing of concrete slabs for 14 days
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications (IV) R.C.C. grade M 20
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of all , dressing of sides and bottom and backfilling in trenches with excavated suitable material (1)Ordinary soil(I) Upto 3 m Depth
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets (iii) 750 mm Dia
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications (II) P.C.C grade M 15
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification
Speed Braker (For 9.0 mt.formation width (5.5 carriage way width) as per technical specification
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification 900 mm equilateral & triangle
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification 600 mm Circular
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification 900 mm Octagonal
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification 600 mm x 450 mm rectangular
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification 300 mm x 900 mm rectangular As per RA (Hazards)
Chevron Alignment Sign Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification
Printing new letters and figures of any shade printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give and even shade as per drawings and Technical Speficifation Gujarati (Matras Commas and the like not to be measured and paid for. Half letters shall be counted as half only)
Printing new letters and figures of any shade printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give and even shade as per drawings and Technical Speficifation English and Gujarati
Providing and fixing of a typical design of PMGSY informatory sign board is shown in fig. The specification and installation details of the typical sign board are given below: (i) The board will be a composite unit consisting of three plate of Aluminiums composite materials (ACM), material specifications as per Technical specification . The top most plate will be in diamond shape of 600mm X 600mm size, riveted over welded M.S. angle iron frame of 25mm X 25mm X 5mm size on back on edges. The middle plate will be 1200mm X 150mm size riveted over welded M.S. angle iron frame of 25mm X 25mm X 5mm size on back on edges. The main lower most plate will be 1500mm X 600mm size, riveted over welded M.S. angle iron frame of 25mm X 25mm X 5mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75mm X 75mm (12 SWG) sheet tubes post placed at 1125mm apart center to center. The top of the middle plate will be flushed with the top of 75mm dia. medium steel tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450mm X 450mm X 600mm below ground level. The height of bottom of the lower most plate will be 1200mm from normal ground level and the bottom of middle plate will be 100mm above the top level of the lower most plate. The diamond shaped plate mounted over angle iron frame will be connected to middle plate by square medium steel section of 47mm X 47mm thickness 12 SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be welded to the bottom point of the diamond shaped plate. ii). The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per Technical specification. Messages/Borders. All the sections of the frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing.
Providing & fixing of typical PMGSY Citizen's information board as per drawing , 2 nos. 433 thick ACM plate of 900 X 750 mm fixed at top and bottom duly welded diagonally with MS square hollow section 75 X 75 X 5 mm thick as per standard design of national rural infrastructure development agency. Painting lettering with retroreflective sheeting class B as per drawing square hollow section post duly embadded in M20 (600 X 600 X 750 mm) as per drawing
Providing & fixing Logo Board of PRADHAN MANTRI GRAM SADAK YOGNA as per standard design of National Rural Infrastructure development agency, diamond size (600 X 600 mm) 3 mm thick ACM plate and board plate size (1100 X 300 mm) 3 mm thick ACM plate and 2.4 m deep length square hollow section (75 X 75 X 6 mm) size including fitting and painting lettering with retroreflective sheeting class B as per drawing incl. fixing in CC M20 (450 X 450 X 600 mm) as per IRC 67
Road Markers / Road stud with lens reflector Providing and fixing of road stud 100x100 mm die cast in aluminium restant to corrosive effect on salt and grit, fitted with lense reflectors, installed in concrete of asphaltic surface by drilling holes 30mm upto a depth of 600mm and bedded in suitable bituminous grout or epoxy mortar
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification 5th Kilometre Stone (precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification 200 m stone (precast)
Boundary piller reinforced cement concrete M-15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and technical specification
Road Marking with Hot Applied Thermoplastic compound with Reflectorising Glass Bends on Bituminious surface. Providing and laying of hot applied thermoplastic compound 2.5 mm. thick including reflectorising glass beads @ 250 gms per sqm. area. Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The Finished surface to be level. Uniform and free from streaks and holes
Fillling in foundation trenches as per drawing and technical specification (i)Sand filling
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets (B) 1000 mm Dia
White washing of parapet walls of CD work and tree truncks White washing two coats on parapet walls and tree trunks including preparation of surface by cleaning scraping etc. as per technical specifications
Dismentaling of Structere like Culverts, bridges , retaining walls and other structure compraising of stone masnory disposal unserviceable material & stacking the serviceable material with all lift & lead as per Technical specifications
Dismentaling of Stone Masonry Structere like Culverts, bridges , retaining walls and other structure compraising of stone masnory disposal unserviceable material & stacking the serviceable material with all lift & lead as per Technical specifications
Removing all type of hume pipe & stacking within includiung earth work & dismentaling of masnory work as per technical specification A) Upto 600 mm dia Hume Pipe
Removing all type of hume pipe & stacking within includiung earth work & dismentaling of masnory work as per technical specification (B) Above 900mm dia Hume pipe
SARASWATI CONSTRUCTION CO.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid