Tender Value
₹2.0 Cr
EMD Value
₹2.5 L
Closing Date
30 Mar 2026, 3:00 pmClosed
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SNT TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less; where, V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Similar Nature of Work: "Any work in connection with Signalling / Telecom installation which includes Maintenance free earthing and / or surge protection work."
5 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Checklist for Tenderer: The Tenderer shall submit signed copy of Check-list placed in documents attached with tender. The Tenderer shall also submit relevant documents of compliance of the checklist if any.
I/We have read the tender notice (NIT)detail, schedule of material and works and Tender document along with all the conditions attached/referred to, in this tender document and agree to abide by the said conditions.
It is certified that i am the authorized person to represent the firm and I am authorized to sign the tender and all the document on behalf of the firm.
I/We hereby agree to abide by the Indian Railway Standard General Condition of contract (GCC) with all correction slip up to date and to carry out the work according to the special conditions of contract and specification of material and works as laid down by Railway as mentioned in the tender document.
Bhavnagar Division: Provision of Earthing arrangement & Surge Protection Devices (SPDs) for Power supply Equipments/IPS, BPAC, UFSBI/Block, Relays Racks/CTRs, Dataloggers, ELDs, AFDAS, OFC Room Telecom Equipments & other S&T gears/signals/Loc boxes/LC gates, etc. and Parametric earthing for location boxes of HASSDAC (BPAC) over Bhavnagar Division.
59-2025R1
59-2025R1
Open
Works - General
18 Months
Bhavnagar, Gujarat
₹0
₹2.5 L
30 Mar 2026
7 Mar 2026
16 Mar 2026
39 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,02,53,259.59 | ||
| — | 490.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001and RDSO Spec No. RDSO / SPN/197 with latest Amd. For stations equipment IPS, Block instrument, ELD, DG etc. | — | — | — | 53,22,316.3 | |
| — | 208.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO / E&B / 001 and RDSO Spec No. RDSO / SPN/197 with latest Amd. For LC gates equipment IPS, DG, ELD etc. | — | — | — | 22,59,268.96 | |
| — | 100.00 | — | — | ||
| Supply of Fiber/ SMC/FRP/RCC Earth Chamber. For replacement of old chamber. As per instruction given by Engg in charge. | — | — | — | 64,900 | |
| — | 0.50 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm). 101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2 mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 68,031.77 | |
| — | 0.50 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | — | — | — | 66,252.56 | |
| — | 2000.00 | — | — | ||
| Supply of 10 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in-charge. | — | — | — | 2,11,340 | |
| — | 4500.00 | — | — | ||
| Supply of 35 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in-charge. | — | — | — | 11,14,830 | |
| — | 2000.00 | — | — | ||
| Supply of copper strip for earthing (25mm x 3mm). | — | — | — | 11,46,320 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022-uptoACS10_merged_compressed.pdf
ATTACHMENT
SignedJPOBVPDivisionforundertakingdiggingworkinthevicinityofSTandElectricalcablesmerged..pdf
ATTACHMENT
CHECKLISTFORTENDERERmorethan50Lacs.pdf
ATTACHMENT
RDSOTANonEarthingBondingSurgeLightningProtectionSystem.pdf
ATTACHMENT
ScheduleOfWork.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .