Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹8.7 Cr+₹98.4 L (12.8%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹8.7 Cr+₹1.0 Cr (13.2%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹9.0 Cr+₹1.3 Cr (16.8%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹9.2 Cr+₹1.5 Cr (19.5%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | LUKMAN.T L1 | ZUBAIR L6 | UKS CONSTRUCTIONS LLP L2 | K Kunhimohammed L7 | Midland Contracting Private Limited L8 | MB PRADEEP L5 | O ABDUL MAJEED L3 | SAPIENT INFRA PVT LTD L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply , errection ,testing and commissioning of Pumpsets | |||||||||||
| 1.00 | OD283516/2025-2026:Design Supply, erection ,testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete-The duty condition is as follows.-Discharge per pump: 39 lps -Total Head :132 metre -- - Impeller : Bronze - Shaft : SS/Carbon steel -Speed : rpm
Motor- Supply, erection,testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.
Starter-Design,Supply, erection, testing and commissioning a complete integrated FCMA soft starter panel capable of operating the motor( 100HP CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control and contactorline power contactor , and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V . the standared is to be IEC 60947-4-2-"4.
Panel board: (suitable for operating 2 pump sets but one pump set at a time)-Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of suitable capacity MCCBs as icomer and outgoings with suitable interlocking facility and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. Earthing -Supply of all materials and providing suitable
earthing by using suitable size pipe/ plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor-Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.98 but below 1.0. The capacitor shall confirm to IS 2834. Valves--Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include prper RCC support. Fitting of valves shall include proper RCC support . Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should in suction as well as delivery sides for easy repair works.-". Suction and delivery pipe
connections Supply and fitting of suitable size best quality GI/MS pipe for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping mainTo 6 LL OHSR at 100HP (50% stand bye) CF horizontal split case pump set discharge of 39 LPS against a total head of 132mtr. (1no working at a time one being standby)( Length of Clear Water Pumping main -1500 metre- Size of Pumping main 250 mm
CI.) | 1 | each | 23,18,180 ₹23,18,180 Lowest | 30,90,906.2 ₹30,90,906.2 | 27,13,815.65 ₹27,13,815.65 | 29,36,361 ₹29,36,361 | 30,59,997.15 ₹30,59,997.15 | 27,81,815.4 ₹27,81,815.4 | 25,90,906.21 ₹25,90,906.21 | 27,81,800 ₹27,81,800 |
| 1.00 | OD5071/2026-2027:Design Supply, erection ,testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete-The duty condition is as follows.-Discharge per pump: 55 lps -Total Head :112mtre -- - Impeller : Bronze - Shaft : SS/Carbon steel -Speed : rpm Motor- Supply, erection,testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. Starter-Design,Supply, erection, testing and commissioning a complete integrated FCMA soft starter panel capable of operating the motor( 120HP CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V() . the standared is to be IEC 60947-4-2-"4. Panel board: (suitable for operating 2 pump sets but one pump set at a time)-Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of suitable capacity MCCBs for out going and incoming with suitable interlock facility and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with theMCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. Earthing -Supply of all materials and providing suitable earthing by using suitable size pipe/ plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor-Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.98 but below 1.0. The capacitor shall confirm to IS 2834. Valves--Supply of suitable size best quality heavy duty ISI marked DI double flanged sluice valve and DI Non return valve with suitable pressure rating. Fitting of valves shall include prper RCC support. Fitting of valves shall include proper RCC support . Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should in suction as well as delivery sides for easy repair works.-". Suction and delivery pipe connections Supply and fitting of suitable size best quality GI/MS pipe for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping mainTo 10 LL OHSR at 120HP (50% stand bye) CF horizontal split case pump set discharge of 55 LPS against a total head of 112mtr. (1no working at a time one being standby)( Length of Clear Water Pumping main -1850 metre- Size of Pumping main 250 mm CI.) | 1 | no | 27,62,800 ₹27,62,800 Lowest | 36,83,763 ₹36,83,763 | 32,34,344.72 ₹32,34,344.72 | 34,99,574 ₹34,99,574 | 36,46,926.28 ₹36,46,926.28 | 33,15,387.52 ₹33,15,387.52 | 31,83,763.92 ₹31,83,763.92 | 33,15,380 ₹33,15,380 |
| 1.00 | OD5072/2026-2027:Design Supply, erection ,testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete-The duty condition is as follows.-Discharge per pump: 55 lps -Total Head :110mtre -- - Impeller : Bronze - Shaft : SS/Carbon steel -Speed : rpm Motor- Supply, erection,testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. Starter-Design,Supply, erection, testing and commissioning a complete integrated FCMA soft starter panel capable of operating the motor( 120HP CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100 . the standared is to be IEC 60947-4-2-"4. Panel board: (suitable for operating 2 pump sets but one pump set at a time)-Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of suitable capacity MCCBs for incomer and outgoing with suitable interlock facility and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with theVCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. Earthing -Supply of all materials and providing suitable earthing by using suitable size pipe/ plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor-Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.98 but below 1.0. The capacitor shall confirm to IS 2834. Valves--Supply of suitable size best quality heavy duty ISI marked DI double flanged sluice valve and DI Non return valve with suitable pressure rating. Fitting of valves shall include prper RCC support. Fitting of valves shall include proper RCC support . Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should in suction as well as delivery sides for easy repair works.-". Suction and delivery pipe connections Supply and fitting of suitable size best quality GI/MS pipe for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping mainTo 10 LL OHSR at 120HP (50% stand bye) CF horizontal split case pump set discharge of 55 LPS against a total head of 110mtr. (1no working at a time one being standby)( Length of Clear Water Pumping main -1800 metre- Size of Pumping main 250 mm CI.) | 1 | no | 27,62,800 ₹27,62,800 Lowest | 36,73,764 ₹36,73,764 | 32,34,344.72 ₹32,34,344.72 | 34,99,575 ₹34,99,575 | 36,46,926.28 ₹36,46,926.28 | 33,15,387.52 ₹33,15,387.52 | 36,83,763.92 ₹36,83,763.92 | 33,15,380 ₹33,15,380 |
| 1.00 | OD44635/2026-2027:Design Supply, erection ,testing and commissioning of KWA pre-qualified reputed make Vertical Turbine pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable length line shaft, head shaft, discharge head with support foundation, flexible coupling ,bearings, non reversible ratchet, foundation bolts & nuts etc. complete suitable for coupling the pump and motor etc. including providing suitable concrete foundation including cost of cement sand and metal etc. complete-The duty condition is as follows.-Discharge per pump: 46 lps -Total Head :155 metre -- - Impeller : Bronze - Shaft : SS/Carbon steel -Speed : 1500rpm Motor- Supply, erection,testing and commissioning of KWA prequalified reputed make vertical solid shaft TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. Starter-Design,Supply, erection, testing and commissioning a complete integrated FCMA soft starter panel capable of operating the motor( 120HP CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V . the standared is to be IEC 60947-4-2-"4. Panel board: (suitable for operating 2 pump sets but one pump set at a time)-Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of suitable capacity MCCBs as incomer and outgoing with suitable inter locking facility and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with theMCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. Earthing -Supply of all materials and providing suitable earthing by using suitable size pipe/ plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor-Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.98 but below 1.0. The capacitor shall confirm to IS 2834. Valves--Supply of suitable size best quality heavy duty ISI marked DI double flanged sluice valve and DI Non return valve with suitable pressure rating. Fitting of valves shall include prper RCC support. Fitting of valves shall include proper RCC support . Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should in suction as well as delivery sides for easy repair works.-". Suction and delivery pipe connections Supply and fitting of suitable size best quality GI/MS pipe for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping main to 3.50 MLD WTP at 140 HP (50% stand bye) CF horizontal split case pump set discharge of 46 LPS against a total head of 155 mtr. (1no working at a time one being standby)(Length of Raw Water Pumping main -1800 metre- Size of Pumping main 300 mm DI.) | 1 | no | 35,25,800 ₹35,25,800 Lowest | 43,50,090.5 ₹43,50,090.5 | 40,20,399.46 ₹40,20,399.46 | 43,50,091 ₹43,50,091 | 45,33,252.23 ₹45,33,252.23 | 41,21,138.39 ₹41,21,138.39 | 45,79,042.66 ₹45,79,042.66 | 41,21,130 ₹41,21,130 |
| 1.00 | OD283524/2025-2026:Design,Supply erection testing and commissioning of reputed make best quality Vertical Turbine pump set with all accessories having the following Technical specifications- 1. Supply erection testing and commissioning of suitable reputed make VT Pump -Type :Vertical Turbine-Discharge per pump : 75 LPS- Total Head : 68 m (static frictional)- Suction lift : 16m- Bowl efficiency : 82%- Impeller : Bronze, Column Pipe : MS, Shaft : SS 410,Speed :1450rpm. Supply erection testing and commissioning of suitable reputed make having 1450 rpm SPDP energy efficient 3 phase AC 415/440 Volt, 50 Hz, solid shaft vertically mounted squirrel cage induction motor with all accessories such as non reversible ratchet assembly etc. confirming to relevant IS as suitable in all respect to start and run coupled with pump in item No:1 on all load conditions ( the motor should be of manufacturers approved by KWA) Supplying, erecting, testing and commissioning of reputed made Supplying a complete integrated FCMA soft starter panel capable of operating the motor(100 HP VT Pump sets,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V(for 440V supply) and 7.6KV for (3.3KV supply) and 14.2KV for (6.6KV Supply). The standard is to be IEC 60947-4-23 phase 415/440volt,50Hz. Supplying of best quality suitable size sheet metal fabricated floor mounted dust and vermin proof cubical type suitable control panel board with suitable capacity MCCBs as incomer and outgoing with suitable interlock mechanism to operate pump sets including all cost of materials, painting etc. complete suitable for above pump set duly wired up including providing danger notice as per IE rule and IS code of practice. Suitable capacity best quality APF power capacitor with ISI markings to keep the power factor above 0.98 but below 1.0 Suitable capacity best quality volt meter with selector switches-g. Suitable capacity best quality Ammeter with selector switches- h. Dry running preventer Supply of best quality 100 mm dia pressure gauge glicerine filled with with SS body calibrated and graduated in kg/cm2 (0 to 10 )with stop cock and copper tube of required length all other accessories. Supply of best quality suitable size reputed make CastSteel heavy duty Sluice valve having ISI mark ( class PN 1.60). Supply of best quality suitable size reputed make heavy duty Cast Steel non return valve having ISI mark ( class PN 1.60). Supply of earthing materials for providing earthing to the above as per IE rule and IS code of practice including cost and conveyance etc. Supply of suitable size good quality Flanged DIK9 pipes and specials required for Suction and Deliver pipes connection to pumping main including cost and labour charges etc. Supply of best quality suitable gauge AYFY cable, , glands, sockets, etc. required for providing electrical connection from main panel board to isolator, and from isolator to starters, motors, capacitors panel board, switch gears, etc as per IE rules and IS code of practice. Erection charges of motor and pump including all the items 1 to 10 on suitable cement concrete / MS foundations with MS plate providing copper strips etc. as per relevant IS standard and IE rules including cost of foundation works and labour charges etc. complete , including connection to delivery pipe with valve using suitable specials required ( specials if any required to the supplied by the contractor with no cost) and giving trial run as per the satisfaction of the departmental officers at site etc.complete. | 1 | no | 24,26,000 ₹24,26,000 Lowest | 31,50,687.5 ₹31,50,687.5 | 27,66,303.58 ₹27,66,303.58 | 29,93,153 ₹29,93,153 | 31,19,180.58 ₹31,19,180.58 | 28,35,618.7 ₹28,35,618.7 | 31,50,687.45 ₹31,50,687.45 | 28,35,610 ₹28,35,610 |
| 1.01 | OD44664/2026-2027:Design, Supply ,errection ,testing and commissioning of KWA approved reputed make best quality electrically driven Open well Submersible pump Set having a discharge of 17 LPS against a total Head of 154m with all accessories etc. complete confirming to relevent IS Codes and Suitable in all respect with all accessories such as motor, Panel board,starter, capacitors, suction/delivery pipes , inter connection works ,supply and fixing Non return valves,Sluice valve including errection and trailrunning etc; complete as per the direction of Engineer in Charge | 1 | no | 9,57,900 ₹9,57,900 Lowest | 12,44,055.5 ₹12,44,055.5 | 10,92,280.71 ₹10,92,280.71 | 11,81,852 ₹11,81,852 | 12,31,614.93 ₹12,31,614.93 | 11,19,649.93 ₹11,19,649.93 | 12,44,055.48 ₹12,44,055.48 | 11,19,640 ₹11,19,640 |
| 1.01 | OD283515/2025-2026:Supplying and installation of Electro- Magnetic Flow meter (Suitable for 250 mm Clear Water Pumping main) conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD Display unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ Carbon Steel with anti corrosive protection and inside liner to be made up of Hard Rubber/neoprene all confirming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions." | 3 | each | 1,15,000 ₹3,45,000 Lowest | 1,42,120 ₹4,26,360 | 1,31,348.84 ₹3,94,046.52 | 1,42,120 ₹4,26,360 | 1,48,104.04 ₹4,44,312.12 | 1,34,640 ₹4,03,920 | 1,49,600.04 ₹4,48,800.12 | 1,34,640 ₹4,03,920 |
| 1.01 | OD44636/2026-2027:Supplying and installation of Electro- Magnetic Flow meter (Suitable for 300 mm Clear Water or Raw Water Pumping main) conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD Display unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ Carbon Steel with anti corrosive protection and inside liner to be made up of Hard Rubber/neoprene all confirming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions." | 2 | no | 1,38,000 ₹2,76,000 Lowest | 1,70,334.9 ₹3,40,669.8 | 1,57,425.31 ₹3,14,850.62 | 1,70,334.8 ₹3,40,669.6 | 1,77,506.9 ₹3,55,013.8 | 1,61,369.1 ₹3,22,738.2 | 1,79,299.9 ₹3,58,599.8 | 1,61,360 ₹3,22,720 |
| 1.01 | OD44663/2026-2027:Supplying and installation of a mechanical flow meter of Woltman type confirming to ISO 4064 class B suitable for 150mm dia Raw Water Pumping main including all fittings and labour charges as per the direction of engineer in site | 1 | no | 24,500 ₹24,500 Lowest | 30,344.2 ₹30,344.2 | 28,044.42 ₹28,044.42 | 30,343.95 ₹30,343.95 | 31,621.84 ₹31,621.84 | 28,747.12 ₹28,747.12 | 31,941.25 ₹31,941.25 | 28,740 ₹28,740 |
Tender Value
₹9.9 Cr
EMD Value
₹2 L
Closing Date
11 Aug 2026, 3:00 pmClosed
Superintending Engineer
PH CIRCLE, KWA, MALAPPURAM
AMRUT 2 0 Malappuram Municipality Laying of New Distribution Lines Providing 1260 FHTCs Distribution Network Optimization by Replacing Existing AC and GI Pipelines and Supply Erection Testing and Commissioning of New Pump Sets Part I Pipeli
2026_KWA_861741_1
SE/PHC/MPM/07/2026-27
Open Tender
Civil Works - Water Works
Item Rate
180 days
Malappuram
Refer Tender Documents
9 documents required · 9 mandatory
₹11,025
₹2 L
PH CIRCLE, KWA, MALAPPURAM
28 Sept 2026
21 Jul 2026
13 Aug 2026
21 Jul 2026
11 Aug 2026
21 Jul 2026
21 Jul 2026 - 30 Jul 2026
30 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply , errection ,testing and commissioning of Pumpsets | |||||
| 1.001 | OD283516/2025-2026:Design Supply, erection ,testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete-The duty condition is as follows.-Discharge per pump: 39 lps -Total Head :132 metre -- - Impeller : Bronze - Shaft : SS/Carbon steel -Speed : rpm
Motor- Supply, erection,testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.
Starter-Design,Supply, erection, testing and commissioning a complete integrated FCMA soft starter panel capable of operating the motor( 100HP CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control and contactorline power contactor , and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V . the standared is to be IEC 60947-4-2-"4.
Panel board: (suitable for operating 2 pump sets but one pump set at a time)-Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of suitable capacity MCCBs as icomer and outgoings with suitable interlocking facility and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. Earthing -Supply of all materials and providing suitable
earthing by using suitable size pipe/ plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor-Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.98 but below 1.0. The capacitor shall confirm to IS 2834. Valves--Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include prper RCC support. Fitting of valves shall include proper RCC support . Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should in suction as well as delivery sides for easy repair works.-". Suction and delivery pipe
connections Supply and fitting of suitable size best quality GI/MS pipe for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping mainTo 6 LL OHSR at 100HP (50% stand bye) CF horizontal split case pump set discharge of 39 LPS against a total head of 132mtr. (1no working at a time one being standby)( Length of Clear Water Pumping main -1500 metre- Size of Pumping main 250 mm
CI.) | - | each | - | - |
| 1.002 | OD5071/2026-2027:Design Supply, erection ,testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete-The duty condition is as follows.-Discharge per pump: 55 lps -Total Head :112mtre -- - Impeller : Bronze - Shaft : SS/Carbon steel -Speed : rpm Motor- Supply, erection,testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. Starter-Design,Supply, erection, testing and commissioning a complete integrated FCMA soft starter panel capable of operating the motor( 120HP CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V() . the standared is to be IEC 60947-4-2-"4. Panel board: (suitable for operating 2 pump sets but one pump set at a time)-Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of suitable capacity MCCBs for out going and incoming with suitable interlock facility and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with theMCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. Earthing -Supply of all materials and providing suitable earthing by using suitable size pipe/ plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor-Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.98 but below 1.0. The capacitor shall confirm to IS 2834. Valves--Supply of suitable size best quality heavy duty ISI marked DI double flanged sluice valve and DI Non return valve with suitable pressure rating. Fitting of valves shall include prper RCC support. Fitting of valves shall include proper RCC support . Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should in suction as well as delivery sides for easy repair works.-". Suction and delivery pipe connections Supply and fitting of suitable size best quality GI/MS pipe for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping mainTo 10 LL OHSR at 120HP (50% stand bye) CF horizontal split case pump set discharge of 55 LPS against a total head of 112mtr. (1no working at a time one being standby)( Length of Clear Water Pumping main -1850 metre- Size of Pumping main 250 mm CI.) | - | no | - | - |
| 1.003 | OD5072/2026-2027:Design Supply, erection ,testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete-The duty condition is as follows.-Discharge per pump: 55 lps -Total Head :110mtre -- - Impeller : Bronze - Shaft : SS/Carbon steel -Speed : rpm Motor- Supply, erection,testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. Starter-Design,Supply, erection, testing and commissioning a complete integrated FCMA soft starter panel capable of operating the motor( 120HP CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100 . the standared is to be IEC 60947-4-2-"4. Panel board: (suitable for operating 2 pump sets but one pump set at a time)-Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of suitable capacity MCCBs for incomer and outgoing with suitable interlock facility and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with theVCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. Earthing -Supply of all materials and providing suitable earthing by using suitable size pipe/ plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor-Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.98 but below 1.0. The capacitor shall confirm to IS 2834. Valves--Supply of suitable size best quality heavy duty ISI marked DI double flanged sluice valve and DI Non return valve with suitable pressure rating. Fitting of valves shall include prper RCC support. Fitting of valves shall include proper RCC support . Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should in suction as well as delivery sides for easy repair works.-". Suction and delivery pipe connections Supply and fitting of suitable size best quality GI/MS pipe for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping mainTo 10 LL OHSR at 120HP (50% stand bye) CF horizontal split case pump set discharge of 55 LPS against a total head of 110mtr. (1no working at a time one being standby)( Length of Clear Water Pumping main -1800 metre- Size of Pumping main 250 mm CI.) | - | no | - | - |
| 1.004 | OD44635/2026-2027:Design Supply, erection ,testing and commissioning of KWA pre-qualified reputed make Vertical Turbine pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable length line shaft, head shaft, discharge head with support foundation, flexible coupling ,bearings, non reversible ratchet, foundation bolts & nuts etc. complete suitable for coupling the pump and motor etc. including providing suitable concrete foundation including cost of cement sand and metal etc. complete-The duty condition is as follows.-Discharge per pump: 46 lps -Total Head :155 metre -- - Impeller : Bronze - Shaft : SS/Carbon steel -Speed : 1500rpm Motor- Supply, erection,testing and commissioning of KWA prequalified reputed make vertical solid shaft TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. Starter-Design,Supply, erection, testing and commissioning a complete integrated FCMA soft starter panel capable of operating the motor( 120HP CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V . the standared is to be IEC 60947-4-2-"4. Panel board: (suitable for operating 2 pump sets but one pump set at a time)-Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of suitable capacity MCCBs as incomer and outgoing with suitable inter locking facility and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with theMCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. Earthing -Supply of all materials and providing suitable earthing by using suitable size pipe/ plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor-Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.98 but below 1.0. The capacitor shall confirm to IS 2834. Valves--Supply of suitable size best quality heavy duty ISI marked DI double flanged sluice valve and DI Non return valve with suitable pressure rating. Fitting of valves shall include prper RCC support. Fitting of valves shall include proper RCC support . Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should in suction as well as delivery sides for easy repair works.-". Suction and delivery pipe connections Supply and fitting of suitable size best quality GI/MS pipe for a total length of 10m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping main to 3.50 MLD WTP at 140 HP (50% stand bye) CF horizontal split case pump set discharge of 46 LPS against a total head of 155 mtr. (1no working at a time one being standby)(Length of Raw Water Pumping main -1800 metre- Size of Pumping main 300 mm DI.) | - | no | - | - |
| 1.005 | OD283524/2025-2026:Design,Supply erection testing and commissioning of reputed make best quality Vertical Turbine pump set with all accessories having the following Technical specifications- 1. Supply erection testing and commissioning of suitable reputed make VT Pump -Type :Vertical Turbine-Discharge per pump : 75 LPS- Total Head : 68 m (static frictional)- Suction lift : 16m- Bowl efficiency : 82%- Impeller : Bronze, Column Pipe : MS, Shaft : SS 410,Speed :1450rpm. Supply erection testing and commissioning of suitable reputed make having 1450 rpm SPDP energy efficient 3 phase AC 415/440 Volt, 50 Hz, solid shaft vertically mounted squirrel cage induction motor with all accessories such as non reversible ratchet assembly etc. confirming to relevant IS as suitable in all respect to start and run coupled with pump in item No:1 on all load conditions ( the motor should be of manufacturers approved by KWA) Supplying, erecting, testing and commissioning of reputed made Supplying a complete integrated FCMA soft starter panel capable of operating the motor(100 HP VT Pump sets,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V(for 440V supply) and 7.6KV for (3.3KV supply) and 14.2KV for (6.6KV Supply). The standard is to be IEC 60947-4-23 phase 415/440volt,50Hz. Supplying of best quality suitable size sheet metal fabricated floor mounted dust and vermin proof cubical type suitable control panel board with suitable capacity MCCBs as incomer and outgoing with suitable interlock mechanism to operate pump sets including all cost of materials, painting etc. complete suitable for above pump set duly wired up including providing danger notice as per IE rule and IS code of practice. Suitable capacity best quality APF power capacitor with ISI markings to keep the power factor above 0.98 but below 1.0 Suitable capacity best quality volt meter with selector switches-g. Suitable capacity best quality Ammeter with selector switches- h. Dry running preventer Supply of best quality 100 mm dia pressure gauge glicerine filled with with SS body calibrated and graduated in kg/cm2 (0 to 10 )with stop cock and copper tube of required length all other accessories. Supply of best quality suitable size reputed make CastSteel heavy duty Sluice valve having ISI mark ( class PN 1.60). Supply of best quality suitable size reputed make heavy duty Cast Steel non return valve having ISI mark ( class PN 1.60). Supply of earthing materials for providing earthing to the above as per IE rule and IS code of practice including cost and conveyance etc. Supply of suitable size good quality Flanged DIK9 pipes and specials required for Suction and Deliver pipes connection to pumping main including cost and labour charges etc. Supply of best quality suitable gauge AYFY cable, , glands, sockets, etc. required for providing electrical connection from main panel board to isolator, and from isolator to starters, motors, capacitors panel board, switch gears, etc as per IE rules and IS code of practice. Erection charges of motor and pump including all the items 1 to 10 on suitable cement concrete / MS foundations with MS plate providing copper strips etc. as per relevant IS standard and IE rules including cost of foundation works and labour charges etc. complete , including connection to delivery pipe with valve using suitable specials required ( specials if any required to the supplied by the contractor with no cost) and giving trial run as per the satisfaction of the departmental officers at site etc.complete. | - | no | - | - |
| 1.006 | OD44664/2026-2027:Design, Supply ,errection ,testing and commissioning of KWA approved reputed make best quality electrically driven Open well Submersible pump Set having a discharge of 17 LPS against a total Head of 154m with all accessories etc. complete confirming to relevent IS Codes and Suitable in all respect with all accessories such as motor, Panel board,starter, capacitors, suction/delivery pipes , inter connection works ,supply and fixing Non return valves,Sluice valve including errection and trailrunning etc; complete as per the direction of Engineer in Charge | - | no | - | - |
| 1.007 | OD283515/2025-2026:Supplying and installation of Electro- Magnetic Flow meter (Suitable for 250 mm Clear Water Pumping main) conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD Display unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ Carbon Steel with anti corrosive protection and inside liner to be made up of Hard Rubber/neoprene all confirming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions." | - | each | - | - |
| 1.008 | OD44636/2026-2027:Supplying and installation of Electro- Magnetic Flow meter (Suitable for 300 mm Clear Water or Raw Water Pumping main) conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD Display unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ Carbon Steel with anti corrosive protection and inside liner to be made up of Hard Rubber/neoprene all confirming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions." | - | no | - | - |
| 1.009 | OD44663/2026-2027:Supplying and installation of a mechanical flow meter of Woltman type confirming to ISO 4064 class B suitable for 150mm dia Raw Water Pumping main including all fittings and labour charges as per the direction of engineer in site | - | no | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.53 MB
NIT_VOL1.pdf
Tender Documents • 11.74 MB
NIT_VOL2.pdf
Tender Documents • 0.33 MB
q1toq8new.pdf
Tender Documents • 0.19 MB
BOQ_1457373.xls
BOQ • 0.46 MB
corrigendum.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .