Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr | L1 | Accepted-AOC Awarded the work with the approval from TPC-I |
| 2 | L2₹2.8 Cr+₹3.5 L (1.30%)Rejected-Finance | ₹2.8 Cr+₹3.5 L (1.30%) | L2 | Rejected-Finance Rejected during Financial evaluation |
| 3 | L3₹2.9 Cr+₹13.6 L (4.99%)Rejected-Finance | ₹2.9 Cr+₹13.6 L (4.99%) | L3 | Rejected-Finance Rejected during Financial evaluation |
| 4 | L4₹3.0 Cr+₹22.1 L (8.11%)Rejected-Finance SINGHI HOUSE RM ROAD JORHAT 785001 | JORHAT | JORHAT | ASSAM | 785001 | ₹3.0 Cr+₹22.1 L (8.11%) | L4 | Rejected-Finance Rejected during Financial evaluation |
| 5 | L5₹3.0 Cr+₹23.8 L (8.70%)Rejected-Finance A T ROAD EVERLITE HOUSE PANITOLA LAIPULI TINSUKIA ASSAM 786183 | TINSUKIA | ASSAM | 786183 | ₹3.0 Cr+₹23.8 L (8.70%) | L5 | Rejected-Finance Rejected during Financial evaluation |
Tender Value
₹3.4 Cr
EMD Value
₹10 L
Closing Date
22 Dec 2020, 12:00 pmClosed
Chief General Manager PPD APDCL
Office of the CGM PPD APDCL 6th floor Bijulee Bhawan Paltanbazar Guwahati 781001
Construction of new industrial feeder and renovation of existing industrial feeder under Dhekiajuli ESD I and II , construction of dedicated tea feeder under Sootea ESD and Gohpur ESD under Tezpur Electrical Circle APDCL under UDAY 2017_18 Scheme
2020_APDCL_19585_1
APDCL/UDAY/FDR_SPR/PKG 09
Open Tender
Electrical Works
Turn-key
210 days
Tezpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,000
₹10 L
Yes
Bijulee Bhawan Guwahati
1 Mar 2021
9 Dec 2020
22 Dec 2020
9 Dec 2020
22 Dec 2020
15 Dec 2020
14 Dec 2020
1. Reconductoring of existing 9.3 KM of 11kV Industry feeder and construction of new 2.5 KM of 11kV line for bifurcation of the 11kV Industry and Rural feeder under Dhekiajuli ESD-I, 2.Bifurcation of the existing 11 kV Batashipur Centre feeder at Panbari Exchange and construction of new 2 KM 11 kV line to provide quality and reliable power supply to Monmohinipur TE & Shyamaguri TE under Dhekiajuli ESD-I, 3. Construction of new 11 KV line from 33/11 KV Thelamara sub-station to Chariduar TE for separation of Chariduar TE from Rural feeder under Dhekiajuli ESD-II, 4. Construction of 6 KM new 11 KV dedicated feeder from 33/11 KV Sootea sub-station to Pratabgarh Tea Estate under Sootea ESD, 5. Construction of new 0.3 KM 11kV dedicated Tea feeder from 33/11 kV Duffagarh Sub-station to Buroi TE and Construction of 11 KM new 11kV line from Dufflagarh 33/11 kV Sub-Station to Brahmajan TE and Nirmala TE under Gohpur ESD within the jurisdiction of Tezpur Electrical Circle, APDCL under UDAY 2017-18 Scheme.
Description of Work / Item(s)
1.Reconductoring of 9.3 KM of 11kV Industry feeder from existing ACSR Weasel Conductor to ACSR Raccoon Conductor emanating from 33/11 KV Mizibari Sub Station under Dhekiajuli ESD-1. (BoQ3)
2. Construction of 2.5 KM new 11 KV line to feed power to connect to the existing 11 KV Industry feeder for bifurcating from 11 KV common rural feeder under Dhekiajuli ESD-1. (BoQ4)
3. Separation of Monmohinipur TE from Panbari Exchange for bifurcation of Batashipur Centre for quallity power to Monmohinipur, Shyamaguri TE under under Dhekiajuli ESD-1 (Line Length: 2.0 KM) (BoQ5)
4. Construction of 4.5 KM new 11 KV line from 33/11 KV Thelamara sub-station to Chariduar TE for separation of Chariduar TE from Rural feeder under Dhekiajuli ESD-2. (BoQ6)
5. Construction of 6 KM new 11 KV dedicated feeder from 33/11 KV Sootea sub-station to Pratabgarh Tea Estate under Sootea ESD. (BoQ7)
6. Construction of 11 KV dedicated feeder from 33/11 KV Dufflagarh sub-station to Buroi Tea Estate bifurcating AP New Balijan feeder under Gohpur ESD. (Line Length: 0.3 KM). (BoQ8)
7.Construction of 11 KM new 11 kV line from Dufflagarh 33/11 KV Sub-Station to Brahmajan TE & Nirmala TE under Gohpur ESD. (BoQ9)
Description of Work / Item(s)
Supply and erection of P.S.C. Pole 8.75 M Long with grouting
Supply, fitting and fixing of GI Channel Cross Arm (100x50x6x2200) mm
Supply, fitting and fixing of 11 KV Disc Insulator 70 KN
Supply, fitting & fixing of Hardware fittings for Disc Insulator 70 KN
Supply, fitting & fixing of 11 KV Polymeric Pin Insulator
Supply and erection of ACSR Raccoon Conductor
Supply, fitting & fixing of Tension Clamp for Raccoon conductor
Supply, fitting & fixing of HT Stay Set
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting fixing of PG Clamp for Raccoon
Supply, fitting & fixing of GI Nuts and Bolts(Assorted) with GI Washer
Supply, fitting & fixing of GI Stay Wire, 7/10 SWG
Supply, fitting & fixing of GI Pole Clamp
Description of Work / Item(s)
Supply and erection of P.S.C. Pole 9.75 M Long with grouting
Supply, fitting & fixing of 11 KV DO fuse 150 A
Supply, fitting & fixing of 11 KV GOAB 400 A
Supply, fitting & fixing of GI Channel Cross Arm (100x50x6x2200) mm
Supply, fitting & fixing of GI Guard Channel Cross Arm (75x40x6) mm
Supply, fitting & fixing of GI Channel Cross Arm (75x40x6x2200) mm
Supply, fitting & fixing of GI Angle Cross Arm (50x50x6) mm for cross bracing
Supply, fitting & fixing of GI 11 KV T Cross arm with angle size (50x50x6) mm
Supply, fitting & fixing of 11 KV Disc Insulator 45 KN,T&C Polymer
Supply, fitting & fixing of Hardware fittings for Disc Insulator 45 KN,T&C Tension Type
Supply,fitting & fixing of 11 KV Polymeric Pin Insulator
Supply and erection of ACSR Raccoon Conductor
Supply, fitting & fixing of Tension Clamp for Raccoon conductor
Supply, fitting & fixing of CI Earth Pipe 1.8 Mtr.
Supply, fitting & fixing of Hot dip GI Wire 8 SWG for guarding
Supply, fitting & fixing of Hot dip GI Wire 6 SWG for earthing
Supply, fitting & fixing of HT Stay Set
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting & fixing of PG Clamp for Raccoon
Supply, fitting & fixing of HT Danger Plate
Supply, fitting & fixing of GI Nuts and Bolts(Assorted) with GI Washer
Supply,fitting & fixing of Barbed wire
Supply, fitting & fixing of GI Stay Wire, 7/10 SWG
Supply,fitting & fixing of GI Pole Clamp
Supply,fitting & fixing of I Hook G.I.
Description of Work / Item(s)
Supply and erection of P.S.C. Pole 9.75 M Long with grouting
Supply, fitting & fixing of 11 KV DO fuse 150 A
Supply, fitting & fixing of 11 KV GOAB 400 A
Supply, fitting & fixing of GI Channel Cross Arm (100x50x6x2200) mm
Supply, fitting & fixing of GI Guard Channel Cross Arm (75x40x6) mm
Supply, fitting & fixing of GI Channel Cross Arm (75x40x6x2200) mm
Supply, fitting & fixing of GI Angle Cross Arm (50x50x6) mm for cross bracing
Supply, fitting & fixing of GI 11 KV T Cross arm with angle size (50x50x6) mm
Supply, fitting & fixing of 11 KV Disc Insulator 45 KN,T&C Polymer
Supply, fitting & fixing of Hardware fittings for Disc Insulator 45 KN,T&C Tension Type
Supply,fitting & fixing of 11 KV Polymeric Pin Insulator
Supply and erection of ACSR Raccoon Conductor
Supply, fitting & fixing of Tension Clamp for Raccoon conductor
Supply, fitting & fixing of CI Earth Pipe 1.8 Mtr.
Supply, fitting & fixing of Hot dip GI Wire 8 SWG for guarding
Supply, fitting & fixing of Hot dip GI Wire 6 SWG for earthing
Supply, fitting & fixing of HT Stay Set
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting & fixing of PG Clamp for Raccoon
Supply, fitting & fixing of HT Danger Plate
Supply, fitting & fixing of GI Nuts and Bolts(Assorted) with GI Washer
Supply,fitting & fixing of Barbed wire
Supply, fitting & fixing of GI Stay Wire, 7/10 SWG
Supply,fitting & fixing of GI Pole Clamp
Supply,fitting & fixing of I Hook G.I.
Description of Work / Item(s)
Supply and erection of P.S.C. Pole 9.75 M Long with grouting
Supply, fitting & fixing of 11 KV DO fuse 150 A
Supply, fitting & fixing of 11 KV GOAB 400 A
Supply, fitting & fixing of GI Channel Cross Arm (100x50x6x2200) mm
Supply, fitting & fixing of GI Guard Channel Cross Arm (75x40x6) mm
Supply, fitting & fixing of GI Channel Cross Arm (75x40x6x2200) mm
Supply, fitting & fixing of GI Angle Cross Arm (50x50x6) mm for cross bracing
Supply, fitting & fixing of GI 11 KV T Cross arm with angle size (50x50x6) mm
Supply, fitting & fixing of 11 KV Disc Insulator 45 KN,T&C Polymer
Supply, fitting & fixing of Hardware fittings for Disc Insulator 45 KN,T&C Tension Type
Supply,fitting & fixing of 11 KV Polymeric Pin Insulator
Supply and erection of ACSR Raccoon Conductor
Supply, fitting & fixing of Tension Clamp for Raccoon conductor
Supply, fitting & fixing of CI Earth Pipe 1.8 Mtr.
Supply, fitting & fixing of Hot dip GI Wire 8 SWG for guarding
Supply, fitting & fixing of Hot dip GI Wire 6 SWG for earthing
Supply, fitting & fixing of HT Stay Set
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting & fixing of PG Clamp for Raccoon
Supply, fitting & fixing of HT Danger Plate
Supply, fitting & fixing of GI Nuts and Bolts(Assorted) with GI Washer
Supply,fitting & fixing of Barbed wire
Supply, fitting & fixing of GI Stay Wire, 7/10 SWG
Supply,fitting & fixing of GI Pole Clamp
Supply,fitting & fixing of I Hook G.I.
Description of Work / Item(s)
Supply and erection of GI Pole SP-76 with grouting
Supply and erection of GI Pole SP-60 with grouting
Supply, fitting and fixing of GI Channel cross arm (100x50x6x2200) mm
Supply, fitting and fixing of GI Channel cross arm (75x40x6x2200) mm
Supply, fitting & fixing of GI Channel cross arm (75x40x6) mm for guarding
Supply, fitting & fixing of GI Angle cross arm (50x50x6) for side bracing
Supply, fitting & fixing of GI Angle cross arm (50x50x6) for cross bracing
Supply, fitting & fixing of 11 KV Disc insulator 45 kN, T&C (Polymeric)
Supply, fitting & fixing of H/W fittings for Disc insulator T&C (45KN) tension type
Supply, fitting fixing of 11 KV Polymeric pin insulator
Supply and erection of ACSR "Raccoon" conductor
Supply, fitting & fixing of Tension clamp for "Raccoon" conductor
Supply, fitting & fixing of 11 KV DO fuse 150 A
Supply, fitting & fixing of 11 KV GOAB 400 A
Supply, fitting & fixing of CI Earth Pipe
Supply, fitting & fixing of Hot dip G. I. wire, 8 SWG for guarding
Supply, fitting & fixing of Hot dip G. I. wire, 6 SWG for earthing
Supply, fitting & fixing of HT Stay Set
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting & fixing of PG clamp, for "Raccoon" (Alcon 81)
Supply, fitting & fixing of Danger plate HT
Supply, fitting & fixing of GI nuts and bolts (Assorted) with GI washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI wire Stay wire, 7/10 SWG
Supply, fitting & fixing of I Hook GI
Supply, fitting & fixing of GI pole clamp
Supply and erection of 12 KV 9 KA LA, Line Type
Supply and erection of 11 KV Combined CTPT 200-100/5-5
Supply, fitting & fixing of HT Trivector Energy Meter
Supply, fitting & fixing of Control Cable Copper 10 Core 2.5 sq.mm
Supply, fitting & fixing of 11 KV XLPE 3 Core 400 sq.mm (Aluminium)
Supply, fitting & fixing of 11 KV Cable Kit for XLPE 3 Core 300 sq.mm(Outdoor)
Supply, fitting & fixing of 11 KV Cable Kit for XLPE 3 Core 300 sq.mm(Indoor)
Description of Work / Item(s)
Supply and erection of P.S.C. Pole 9.75 M Long with grouting
Supply, fitting & fixing of 11 KV DO fuse 150 A
Supply, fitting & fixing of 11 KV GOAB 400 A
Supply, fitting & fixing of GI Channel Cross Arm (100x50x6x2200) mm
Supply, fitting & fixing of GI Guard Channel Cross Arm (75x40x6) mm
Supply, fitting & fixing of GI Channel Cross Arm (75x40x6x2200) mm
Supply, fitting & fixing of GI Angle Cross Arm (50x50x6) mm for cross bracing
Supply, fitting & fixing of GI 11 KV T Cross arm with angle size (50x50x6) mm
Supply, fitting & fixing of 11 KV Disc Insulator 45 KN,T&C Polymer
Supply, fitting & fixing of Hardware fittings for Disc Insulator 45 KN,T&C Tension Type
Supply,fitting & fixing of 11 KV Polymeric Pin Insulator
Supply and erection of ACSR Raccoon Conductor
Supply, fitting & fixing of Tension Clamp for Raccoon conductor
Supply, fitting & fixing of CI Earth Pipe 1.8 Mtr.
Supply, fitting & fixing of Hot dip GI Wire 8 SWG for guarding
Supply, fitting & fixing of Hot dip GI Wire 6 SWG for earthing
Supply, fitting & fixing of HT Stay Set
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting & fixing of PG Clamp for Raccoon
Supply, fitting & fixing of HT Danger Plate
Supply, fitting & fixing of GI Nuts and Bolts(Assorted) with GI Washer
Supply,fitting & fixing of Barbed wire
Supply, fitting & fixing of GI Stay Wire, 7/10 SWG
Supply,fitting & fixing of GI Pole Clamp
Supply,fitting & fixing of I Hook G.I.
Description of Work / Item(s)
Supply and erection of Steel Tubular Pole SP 76 with grouting
Supply and erection of P.S.C. Pole 9.75 M Long with grouting
Supply, fitting and fixing of 11 KV DO fuse 150 A
Supply, fitting and fixing of 11 KV GOAB 400 A
Supply, fitting & fixing of GI Channel Cross Arm (100x50x6x2200) mm
Supply, fitting & fixing of GI Guard Channel Cross Arm (75x40x6) mm
Supply, fitting & fixing of GI Channel Cross Arm (75x40x6x2200) mm
Supply, fitting & fixing of GI Angle Cross Arm (50x50x6) mm for cross bracing
Supply, fitting & fixing of GI 11 KV T Cross arm with angle size (50x50x6) mm
Supply, fitting fixing of 11 KV Disc Insulator 45 KN,T&C Polymer
Supply, fitting fixing of Hardware fittings for Disc Insulator 45 KN,T&C Tension Type
Supply, fitting & fixing of 11 KV Polymeric Pin Insulator
Supply and erection of ACSR Raccoon Conductor
Supply, fitting & fixing of Tension Clamp for Raccon conductor
Supply, fitting & fixing of CI Earth Pipe 1.8 Mtr.
Supply, fitting & fixing of Hot dip GI Wire 8 SWG for guarding
Supply, fitting & fixing of Hot dip GI Wire 6 SWG for earthing
Supply, fitting & fixing of HT Stay Set with Grouting
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting & fixing of PG Clamp for Raccoon
Supply, fitting & fixing of HT Danger Plate
Supply, fitting & fixing of GI Nuts and Bolts(Assorted) with GI Washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI Stay Wire, 7/10 SWG
Supply, fitting & fixing of GI Pole Clamp
Supply, fitting & fixing of I Hook G.I.
Supply, fitting & fixing of GI pole clamp
Supply, fitting & fixing of 11 KV Gang Operated Switch 400 A
Supply and erection of 11 RMU (20 kA, 630A 3 way non-extensible
Supply and erection of 11 KV Combined CTPT Set
Supply and erection of 11 KV Station Type LA
Supply, fitting & fixing of Cu. Control Cable, 7- core, 2.5 sq. mm.
Supply, fitting & fixing of 3 Ph 4 W ICS DLMS HT Trivector meter
Supply, fitting & fixing of 11 KV XLPE 3 Core 120 sq.mm (Aluminium)
RCC Foundation for RMU
Jayanta Khaund
Kusum Enterprises
SINGHI INFRAPOWER PROJECTS PRIVATE LIMITED
Everlite Engineering Industries
M/S J.D. Construction
Win Power Infra Pvt Ltd
Jayanta Khaund
Kusum Enterprises
SINGHI INFRAPOWER PROJECTS PRIVATE LIMITED
Everlite Engineering Industries
M/S J.D. Construction
Win Power Infra Pvt Ltd
M/S U.K. ENTERPRISE
Everlite Engineering Industries
SINGHI INFRAPOWER PROJECTS PRIVATE LIMITED
M/S J.D. Construction
Kusum Enterprises
Win Power Infra Pvt Ltd
Jayanta Khaund
Everlite Engineering Industries
Kusum Enterprises
SINGHI INFRAPOWER PROJECTS PRIVATE LIMITED
M/S J.D. Construction
Win Power Infra Pvt Ltd
M/S U.K. ENTERPRISE
Everlite Engineering Industries
Kusum Enterprises
SINGHI INFRAPOWER PROJECTS PRIVATE LIMITED
M/S J.D. Construction
Win Power Infra Pvt Ltd
M/S U.K. ENTERPRISE
Everlite Engineering Industries
Kusum Enterprises
SINGHI INFRAPOWER PROJECTS PRIVATE LIMITED
M/S J.D. Construction
Win Power Infra Pvt Ltd
Kusum Enterprises
SINGHI INFRAPOWER PROJECTS PRIVATE LIMITED
Jayanta Khaund
M/S J.D. Construction
Everlite Engineering Industries
Win Power Infra Pvt Ltd
Jayanta Khaund
Kusum Enterprises
Everlite Engineering Industries
SINGHI INFRAPOWER PROJECTS PRIVATE LIMITED
M/S J.D. Construction
Win Power Infra Pvt Ltd
Everlite Engineering Industries
Jayanta Khaund
Kusum Enterprises
SINGHI INFRAPOWER PROJECTS PRIVATE LIMITED
M/S J.D. Construction
Win Power Infra Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .