| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹19.8 L+₹34,871 (1.80%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L2 | Rejected-Finance Being not L1 bidder | |
| 3 | L3₹19.8 L+₹35,896 (1.85%)Rejected-Finance D NO 35 14 13 1 RP PETA GAVARA KANCHARAPALEM VISAKHAPATNAM 530008 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530008 | L3 | Rejected-Finance Being not L1 bidder | |
| 4 | L4₹19.9 L+₹44,910 (2.31%)Rejected-Finance | L4 | Rejected-Finance Being not L1 bidder | |
| 5 | L5₹25.4 L+₹5.9 L (30.6%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L5 | Rejected-Finance Being not L1 bidder |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
13 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINTENANCE OF HT/LT DISRTIBUTION SYSTEM AND OTHER CONNECTED WORKS AT NAVAL PARK, AMZARI PARK, NAUSENABAUGH, NCS AND OTHER MISC WORKS UNDER AGE E/M-I OF GE (UTILITY-I) VISAKHAPATNAM
2023_MES_581027_1
8509/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
6 documents required · 6 mandatory
₹500
Garrison Engineer Utility-I
₹79,000
Yes
20 Mar 2023
14 Feb 2023
15 Mar 2023
14 Feb 2023
13 Mar 2023
1 Mar 2023
Amount
Taking down HT switch gear (Vacuum circuit breaker ) of any make / capacity, 400 to 800 Amp comprising of repairs, complete overhauling / servicing, carrying out preventive maintenance alongwith testing of breakers by current injection test and refixing the same after repair / overhauling complete all as specified and as directed. Note:- (i) The servicing includes for busbar duct chamber, cable alleys and connecting accessories (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning. (iii) Major spares like Breaker bushings, vacuum interrupter assly, busbar spout, busbar spout connections, circuit spout, circuit spout connections, buffer fixed contacts, moving contacts, tank assembly, barriers, solenoid spares, dependent, spring mechanism / motor mechanism, trip unit etc will be measured and paid separately under relevant items. However the rate quoted shall be deemed to include for any other minor spares requiring replacement. (iv) The servicing shall be carried out by auhtorised service engineer of OEM and approval of the same shall be taken from Engr-in-Charge.
Dismantling the spring charging mechanism of the VCB, checking the entire mechanism for any worn / crack / bent / block / loose parts etc. for the following:- (i) Checking the condition of the spring charging motor along with gear box including servicing the motor & replacement of motor bearings if required. (ii) Checking / servicing of ratchet wheel assembly, driving and charging parts. (iii) Checking the auxiliary switch, its contacts for proper functional operation. (iv) Checking & servicing of raising / lowering mechanism and its locking system for proper functioning. (v) Checking & servicing of shutter assembly for its automatic opening / closing. Note:-The items like nuts, bolts, spring washers, petroleum jelly, CTC etc required to put the breaker in serviceable condition shall be supplied by the contractor and rate shall be deemed to be included in the unit rate quoted against this item.
M&L for decarburizing / cleaning complete of 11KV cubicle type VCB panels consisting of bus bar and circuit chamber, metering chamber, CTs, PTs and relay chamber, checking the bus bar and circuit spouts, CTs/ PTs for any arcing / tracks, cleaning with CRC and ensure proper decarburizing, re-fixing the same after applying becktol red varnish, cleaning of metering and relay chamber, checking & replacement of burnt wires, checking & tightening the nuts, bolts & thimbles of incoming / outgoing system & all connections to arrest the loose contacts, supply & replacement of defective rusted bolts & nuts, applying mono-plast compound at bus bar joints after tightening all joints / connections complete all as specified and as directed.
Disconnect and taking out IDMT / Numeric / Microprocessor based relay of any type & make from 11 KV HT panel cleaning the contacts, calibrating the relay by conducting secondary injection tests, checking of current transformer, rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relay and tripping coils, adjustment / setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping, tune / synchronise upstream breaker relay settings, re-installation of relay, testing & commissioning etc complete all as specified and as directed. Note:- (i) Arrangement of necessary testing / calibration kits, testing equipments, tools etc. shall be done by contractor and cost of the same shalll deemed to be included in the unit rate quoted. (ii) Testing & tuning shall be carried out in the presence of representative of the accepting officer to the entire satisfaction of the rep of GE.
M&L for collecting necessary required data & peak load details from IED / DMT of any type / Make from 11kV HT panel, transformer full load details during peak hours, relay Setting calculations & Co-ordination study, unit protection setting of transformers, furnishing feeder wise settings & submitting report with firm recommendations, achieving stream power distribution (complete 11 KV system) overall co-ordinations of time, adjusting / setting to plug and time multiplier settings of IED/DMT complete all as specified and as directed by Engr-in-Charge.
S&F protection relay, numeric type with IDMT/Inverse/Extreme Inverse/DT charectristics with overload, high and instantaneous setting and earth fault srtting Aux supply 110V DC, CT Secondary 5A, make as per OEM suitable for 11kV VCB panel including taking down Old unsv relay complete all as specified and as directed. Note : The instantaneous setting should be have minimum time delay of zero seconds.
S&F of 11kV CT, epoxy cast, current rating with secondary current of 5 amp & minimum primary current 50 to 100 A, single / double ratio, double core (Protection core-5P10 & Metering core- Class 1.0), 25 KA for 1 sec , with minimum 15VA Burden, make as per OEM including taking down old one complete all as specified and as directed.
S&F resin Cast 11kV /√3 / 110v/√3 potential transformers, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F release lever (Nylon ) of rating 400 to 1250 A, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F rectifier unit (Monoblock) for spring charging motor of rating 400 to 1250A,make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F Isolating Contact of rating 400 to 1250A, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F contact spring of rating 400 to 1250A, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F high speed trip relay, type- VAJH, Aux Supply 110V DC, make as per OEMsuitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F drive Beam of rating 630 to 1250A, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F epoxy body of rating 630 to 1250A, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F buffer (for opening spring) of rating 630 to 1600A, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F buffer (for closing spring) of rating 630 to 1600A, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F busbar supporting insulator of rating 630 to 1250A, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F single (Red-Blue) phase bus bar spout of rating 400 to 1250A, make as per OEM suitable for 11kV VCB including taking down old one complete all as specified and as directed.
S&F single (Y) phase bus bar suitable spout of rating 400 to 1250A,make as per OEM suitable for 11kV VCB including taking down old one complete all as specified and as directed.
S&F spring charging universal motor with gear box 220V AC of rating 630 to 2500A, make as per OEM suitable for 11kV VCB including taking down old one complete all as specified and as directed.
S&F multifunction meter, digital type (displaying A, V, PF, Hz, KVA, KW, KVAR, KWh, Karsh etc.) Class 1/0.5 with RS485 port for communication in Modbus protocol, accuracy class-1, e- navigator, including taking down old one complete all as specified and as directed. Make:- Elmeasure / L&T / Schneider / HPL / SOCOMEC
S&F thermostat & space heater in HT VCB of capacity 11 KV with new one, make as per OEM suitable to operate on 230 Volts AC supply with necessary wiring and control cable with toggle switch including taking down old one complete all as specified and as directed.
S&F vacuum interrupter of rating 630 to 1250A, make as per OEM suitable for 11kV VCB including taking down old one complete all as specified and as directed.
S&F closing coil assembly, 110 V DC make as per OEM suitable for 11kV VCB including taking down old one complete all as specified and as directed.
S&F main bus bar shroud (11 KV Grade) of rating 400 to 1250A, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F tripping coil 110 V DC, make as per OEM suitable for 11kV VCB panel including taking down old one complete all as specified and as directed.
S&F indication lamps for C.B. ON / OFF / TRIP / Trip Circuit Healthy and Unhealthy / Spring Charged, make as per OEM suitable for 11kV VCB including taking down old one complete all as specified and as directed.
S&F T‐N‐C Switch (Breaker Control Switch) for control switches & control wiring, make as per OEM suitable for 11kV VCB including taking down old one complete all as specified and as directed.
S&F trip circuit healthy push button for control switches & control wiring, make as per OEM suitable for 11kV VCB including taking down old one complete all as specified and as directed.
M&L for control wiring with appropriate colour code as per relevant IS for control switches & control wiring, make as per OEM suitable for 11kV VCB including taking down old one complete all as specified and as directed.
M&L for power pack DC for auxiliary power supply to operate closing & tripping coils, protection relay circuits & other indication lamps for 11 KV HT VCB panel, make as per OEM suitable to operate the control circuit, input supply 230 Volts AC + 10% to - 30 %, 50 HZ to give an output supply of 110 V, DC with battery backup including taking down old one complete all as specified and as directed.
Supply & laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, Earthed, grade cross sectional area 185 Sqmm, 3 core, laid in trenches / duct / on pole including taking down old one complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Finolex
All as per Sl. Item No. 33.00 above but for cable of size 240 sqmm x 3 Core
M&L cable jointing kit for 11 KV (Earthed grade) 3 core XLPE armoured aluminium conductor cable of size 185 sqmm for outdoor termination, heat shrink type joint complete with jointing material and accessories including taking down old one complete all as specified and directed. Make:- 3M / Denson / Raychem
M&L cable jointing kit for 11 KV (Earthed grade) 3 core XLPE armoured aluminium conductor cable of size 185 sqmm for indoor termination, heat shrink type joint complete with jointing material and accessories including taking down old one complete all as specified and directed. Make:- 3M / Denson / Raychem
M&L cable jointing kit for 11 KV (Earthed grade) 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm for straight through, heat shrink type joint with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem
All as per Sl. Item No. 37.00 but suitable for cable of size 240 to 300 Sqmm
S&F 80 mm bore galvanised steel tubing, medium grade with necessary fittings, laid under road crossing, for cable protection including taking down old one complete all as specified and directed. Make - Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC 1:3:6 or bituminous mix as per existing & matching with the surroundings complete all as specified and directed.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, of size 300mmx 180mm x 40mm, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point including dismantling existing earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M&L for inspection, testing, servicing and overhauling of Factory Made 11 KV, 630 Amps, SF6 Insulated, Motorized, Outdoor RMU, 21 kA for 3 Seconds, Consisting of any nos Incoming and any nos Outgoing Feeders including following complete all as directed by Eng-in- charge :- (a) Preliminary inspection of 11 KV MV Switch gear for any defects. (b)Testing of CTs:- (i) IR test (ii) Ratio test (c) Servicing Switch gear panels :- (i) Cleaning panel (ii) checking the condition of SF6 gas (iii) HV test. Notes:- (1) The GIS Switchgear servicing includes:- (a) Cleaning of GIS for dust, oxidising and decarburizing with CTC. (b) Repair/servicing of spring loaded operating mechanism. (c) Repair/servicing of spring charging motor. (d) Checking, repairing & servicing of gearbox, auxiliary switches, spring, limit switch etc complete. (e) Checking & repairing electrical and mechanical operations. (f) Lubrication all moving parts with petroleum jelly & cleaning all bushing insulators with CTC. (g) Tightening of all mechanical connections of mechanism. (h) Proper tightening all LV connection of VCB and cable chamber & allied connecting accessories. (2) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of RMU panels with approved colour including lettering details all as per existing etc. (3) Major spares will be measured and paid separately under relevant items of BOQ, however the unit rate quoted against this item shall be deemed to include for any other minor spares requiring replacement.
S&F circuit-breaker trip coil kit 24 Vcc/Vdc, make as per OEM suitable for 630 Amps RMU including taking down old one complete all as specified and as directed.
S&F circuit-breaker closing coil kit 24 Vcc/Vdc, make as per OEM suitable for 630 Amps RMU including taking down old one complete all as specified and as directed.
S&F Isolator Switch Position Indication, make as per OEM suitable for 630 Amps RMU including taking down old one complete all as specified and as directed.
S&F VPIS Standard, 3.3 to 7.7 Kv, make as per OEM suitable for 630 Amps RMU including taking down old one complete all as specified and as directed.
S&F lithium batteries, 1/2AA, 3.6V DC, suitable for 630 Amps RMU IDMT Relay, including taking down old one complete all as specified and as directed. Make:- Exide / Amron / Amara raja / Luminous
S&F plug in type Bushings at cable termination chamber, make as per OEM suitable for 630 Amps RMU including taking down old one complete all as specified and as directed.
S&F motor for motorized mechanism 24 Vcc/Vdcr, make as per OEM suitable for 630 Amps RMU including taking down old one complete all as specified and as directed.
S&F relay CSDPR-V2-200, CSPR-V5, make as per OEM suitable for 630 Amps RMU including taking down old one complete all as specified and as directed.
S&F operating handle big size, make as per OEM suitable for 630 Amps RMU including taking down old one complete all as specified and as directed.
M&L for testing of HT 11KV VCB 630A/800A complete for hypotest by injecting high voltage breaker opening / closing timing time testing and tuning of vacuum interrupters and all contacts, current carrying parts, testing and tuning of rotating mechanism, insulation test, micro ohm test with suitable test kits, tool and instruments , test report to be signed by contractor, JE, Engeer-in-Charge & countersigned by GE complete all as directed by the Engineer-in-Charge.
M&L for detecting HT 11KV UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable identification instrument , cable tracer for exact location of under ground cable routes complete all as directed. Note:- The rate quoted deemed to be inclusive of arrangement of necessary fault locator equipment, transportation of equipment& charges for service engineer.
SRI SRK ENGINEERS
M/S CHANDRA ENGINEERS AND CONTRACTORS
UV POWER TECH
SAMPATH ENTERPRISES
MONITOR ENGINEERING WORKS
SRIESWARI ENTERPRISES
SUPREET CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .