Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.7 LAccepted-AOC | 1 | Accepted-AOC The lowest tenderer | |
| 2 | 2₹36.4 L+₹5.7 L (18.5%)Rejected-Finance | 2 | Rejected-Finance Not the lowest tenderer | |
| 3 | 3₹40.0 L+₹9.3 L (30.2%)Rejected-Finance | 3 | Rejected-Finance Not the lowest tenderer | |
| 4 | 4₹44.1 L+₹13.4 L (43.8%)Rejected-Finance | 4 | Rejected-Finance Not the lowest tenderer | |
| 5 | 5₹46.8 L+₹16.1 L (52.3%)Rejected-Finance | 5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
16 Apr 2021, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIRS MAINT OF NARMADA AND VISWAKARMA PUMP HOUSE JYESHTHA DHANISTHA PUMP HOUSE UNDER AGE BRI OF GE NW NAVY NAGAR COLABA MUMBAI
2021_MES_433289_1
8464/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D and category a(i)
7 documents required · 7 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹98,000
Yes
15 May 2021
27 Mar 2021
17 Apr 2021
27 Mar 2021
16 Apr 2021
10 Apr 2021
27 Mar 2021 - 16 Apr 2021
Amount
M & L for providing and applying high solids resin based pigmented concrete compound. It forms a continuous membrane that controls hydration for strong and durable concrete. .It should have specific gravity of 1.02. It can be applied by brush or can be sprayed, If sprayed the nozzle of the spray should be held approximately 450mm from the concrete surface and should be passed back and forth to ensure complete and even coverage. The pump pressure should be maintained at a level to produce a fine spray ensuring complete coverage of the surface, complete all specified and directed by Engineer-in-charge. Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for Scrapping, hammering, chiseling, scrubbing to surfaces of tank/sump at any height using electric/mechanical means, hand brush, blower, etc as recommended by the manufacturer and disposal of all unserviceable complete up to a distance n' exc. 50 m complete all as specified and directed.
M&L for applying a two component non shrinking solvent free epoxy filler. It is high strength, providing the abrasion resistance and compressive strength higher than concrete. To be used as filler only. Suitable for properly prepared concrete surfaces, complete all as specified and directed by Engineer-in-Charge. Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for providing and applying acrylic polymer based cementitious composite water proof coating system. It shall be non- flammable, non - combustible. It shall give tough and hard waterproofing surface. It shall allow entrapped vapour to escape preventing peeling and blistering. It shall have excellent bond to building materials. It shall be highly durable in continuous wet condition. Coating to be applied after proper surface preparation to remove loose dust, cleaning, mixing using slow speed electric drill and application of 2 coats of 2 component, thickness of each coat not less than 1mm (1.50-2.00 kg/Sqm) and applying curing of the surface using low viscosity emulsion which incorporate a special alkali reactive emulsion breaking system on the protection screed. It shoud be non-penetrating continuous filmcomplies with the internationally recognized ASTM C309-90 standards including all tools and tackels complete all as specified and directed by Engineer-in-Charge. Product should have daylight Reflectance of 70% as per ASTM E-1347. Make :Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for applying one coat of two component Amine epoxy coating on the cured surface. The concrete substrate must be sound and of sufficient compressive strength (minimum 20 N/mm2) with a minimum pull off strength of 1.5 N/mm2. The substrate must be clean, dry and free of all contaminants such as dirt, oil, grease etc.Moisture content of substrate surface should not be more than 5% complete all specified and directed by Engineer-in-charge. Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for repair to cracks and damaged existing surfaces of Sump etc by Hydrogen Free Expanding And Plasticising Additive . It plasticizes the mix, allowing for substantial reduction in water without affecting the fluidity, thus improving the strength and impermeability, the admixture/ additive in cement to provide non‐shrink properties Cementitious Cable Encapsulation . (a). Fixing of GI nozzles in zig-zag fashion not more than 50cm c/c on RCC surfaces on all directions as required after drilling holes in concrete, fixing GI nozzles with fast setting mortar and covering with renderoc plug. The size of holes shall be 20mm dia and 75mm in depth. complete all as specified and directed by Engineer-in-Charge. Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
Providing and applying two coats of single part elastomeric acrylic water based coating for surface based on high quality acrylic emulsion, functional filler, sunlight stable pigment and quality fungicides. The coating should have excellent flexibility to cover hairline cracks (upto 0.5 mm), UV resistant, microbial resistance, low dirt pickup with elongation at break of 220%, tensile strength of 0.7 MPa, Hardness Shore A scale of 80 and adhesion strength of 3.4 MPa. and apply one coat of water based copolymer emulsion, formulated to achieve specific performance characteristics. It should have Excellent adhesion to concrete & cementious surfaces, Excellent water retention after film formation, Excellent penetration into the substrate there by providing the best adhesion. Substrate should have sufficient strength to receive the top coating. Any defects in the substrate like surface undulations, cracks, pin holes etc., should be rectified/filled before starting application.It should have specific gravity between 1.00± 0.02, Touch Dry @ 30 C -1 -2 hours. complete all specified and directed by Engineer-in-charge. Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.,
M&L for two component amine cured epoxy mastic coating using Light brush blasting using nonmetallic abrasive leaving a clean, rough and even pattern.it should be based on a 100% epoxy formulation and contains no solvents or water diluents. Apply two coats with brush or squeeze to the existing surface, working well into the substrate.it should achieve Compressive Strength of >70 MPa after 14days, having pot life Pot life, minutes at 27⁰C, 100 g >40 mass, complete all specified and directed by Engineer-in-charge. Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for providing and applying single component cement based free flowing grout with 10 mm washed aggregates; The grout shall be having non shrink property and a positive expansion of up to min 1 % in the plastic state and a flowability of 3 M at head of 250 mm for a gap width of 50 mm, developing a compressive strength of 25 MPa in 1 day & 60 MPa in 28 days, shall not bleed or segregate, having a minimum pot life of 20 minutes after which the expansion shall start, shall be also developing a flexural strength of Minimum 10 MPa & bond strength of 10 MPa, It shall have resistance to dynamic loads and specimens shall not get damaged /cracked on being subjected to alternate loads of 5 MPa to 25 MPa @ 500 Cycles per minute for minimum 2 Mio cycles, It shall be chloride free and creep resistant; with epoxy bonding agent of Thermax Ltd /SNI Infra/cipy polyurethane having mix density of 1.45 to 1.5 kg/ltr,compressive strength(BS-6319 PT 3)-40 MPa at 7 days bond strength (ASTM- C 881)-11 MPa at 7 days having an overlay time of 3 hrs at 30°C pouring cementitious grout into the formwork using suitable arrangement or if required using pumping device for and the bottom shuttering after 7 days ensuring proper bond between the cementitious grout and existing concrete substrate etc including all tools and tackles as per accepting officer,complete all specified and directed by eng-in charge. Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for protecting and plastering of waterproofed surface Using cement based, micro- silica restoration mortar.The product needing only addition of water at site which can be applied by trowel.cement, sand can be used for finishing purpose. It is reinforced with specially designed bean shaped, alkali resistant synthetic fibers for exceptional resistance to cracking. It is recommended for repair situations requiring application of mortar up to 10 mm thickness in one layer.The product shall achieve a compressive strength of 11 MPa in 1 day & 30 MPa in 28 days and a minimum flexural strength of 6 MPa @ 7 days. It shall have a tensile strength of minimum 2 MPa. It shall have a minimum bond strength of 2 MPa, complete all specified and directed by Engineer-in-charge. Make: Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for providing and fixing welded MS wire mesh weighing not less than 1 kg/sqmt on the prepared surface which should be cleaned and should be removed from dirt, fungus and all foreign material and applying amine cured epoxy coating cum primer A film thickness of approx. 1 to 2mm should be built up in two coats, should achieve Adhesion bond strength 1 N/mm2, pot life of 30 minutes@30 C. Before applying primer Concrete / steel surface should be cleaned by any suitable method (like sand blasting, water jetting etc.) to remove old coatings, grease, oil, curing compounds, loose particles, weld spatter, flux, rust etc, complete all specified and directed by Engineer-in-charge. Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for providing and applying the treated surface with high quality repair mortar with polymer and fibre content (mixed with cement, special additives and sand).water ratio of which shall be 0.16, 28 days compressive strength shall be 30 MPa,mixed density shall be 2.18 kg/ltr, flexural strength shall be 6 MPa for 7 days and tensile strength for 7 days shall be more than 2MPa.Its adhesion bond strength shall be greater than 2 MPa with creep strain reduction of 8%. The modulus of elasticity of this product shall be 23-26 KN/mm². It shall not bleed / segregate on adding water and shall provide dual shrinkage compensation i.e – both plastic & hardened. It shall be capable of being applied in thicknesses of 20 mm without sagging or falling and shall have minimum adhesive bond strength of 2 MPa.All cementitious systems have to be cured for a minimum period of 15 days by water curing. Note : The mortar should be sprayed using gunitting machine.the nozzle of the spray should be held approximately 450mm from the concrete surface and should be passed back and forth to ensure complete and even coverage. The pump pressure should be maintained at a level to produce a fine spray ensuring complete coverage of the surface,complete all specified and directed by Engineer-in-charge. Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for drilling hole chemical anchoring of reinforcement on existing columns/chajja/beams with Hilti HIT-HY 70 minimum hole depth 100mm, steel bar 12mm dia and drill bit dia 14mm, complete all as specified and directed by Engineer-in-Charge. Note : This item shall be undertaken by the authorised rep of Hilti india Pvt Ltd/Carlisle Syntec Middle Cast/ SNI Infra Tech Pvt Ltd/Thermax Ltd/Kryton Build Mat Co Pvt Ltd.
M&L for MS TMT bars 6 to 8mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9mm dia complete all as specified and directed by the Engineer-in-Charge
Steel form work to sides and soffits of lintels, beams, columns, shelves, chajjas including overhangs etc for fair finished flat surface, complete all as specified and directed by Engr-in-charge
Material and labour for removing of the cavities roughening the smooth surfaces, scrapping out / removing corrosion all loose/scale/rust etc from the visible reinforcement by applying rust remover @ 200ml per sqm and cleaning the steel reinforcement properly, and then applying applying single component,cementitious corrosion inhibiting primer per manufacturers instructions of exposed and new steel reinforcement complete all as specified and directed by Engineer-in-Charge. Make :Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
Note: (a) The work for item Ser No 1.00 to 16.00 to shall be executed directly by company or their authorized applicator. Application shall be authorized in writing by company and guarantee/responsibility of work executed shall be owned by company in writing. (b) Quoted rate shall be inclusive of material all labors tools and plants scaffolding and working upto 15 mtr height. (c) Adoption of necessary safety arrangement like safety belts. ropes. helmets, netting etc. which are required for safety of working at height etc. which are required for safety of working at height exceeding 3 to 25 mtr height shall be mandatary and deemed to be inclusive on quoted rates.
Diamond Construction
M/s Raghav Traders
M/s R.D. Company
M/S MUKESH AGARWAL
M/S DURGA ASSOCIATES
SHREE JAGDISH FURNITURE CO.
M/s Manish Contractor
S Balwinder Singh
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .