Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.5 L+₹98,889 (2.57%)Rejected-Finance AIR FORCE ROAD NEAR BRIDGE OPP KHETIWADI RAJIV NAGAR JAMNAGAR 361002 | JAMNAGAR | JAMNAGAR | GUJARAT | 361002 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹39.6 L+₹1.1 L (2.83%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹42.0 L+₹3.4 L (8.92%)Rejected-Finance | L4 | Rejected-Finance Not being L1 |
Tender Value
₹48.2 L
EMD Value
₹96,420
Closing Date
24 Oct 2023, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361150
Special repair to Bathroom of bldg No. P-143 and P-265 and Addition/ Alteration to External Paint Scheme of Certain Sailors MdAccn at INS Valsura, Jamnagar
2023_MES_620829_1
8695/VAL/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹96,420
Yes
8 Nov 2023
27 Sept 2023
26 Oct 2023
27 Sept 2023
24 Oct 2023
12 Oct 2023
Amount
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for in this Schedule and removal of entire debris as ordered outside MoD land complete all as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same opening as ordered after other repair works are carried out including easing and adjusting of shutter as required including renewal of unserviceable screws complete all as directed.
M&L for PCC 1:3:6, type C1 (using 20mm graded crushed stone aggregate) as in roof kerbs, mud stops, coved fillets, levelling course, filling in Sunken portion and similar works including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L for cement concrete 1:2:4 type B0, using 12.5mm graded crushed stone aggregate as in roof kerbs, mud stops, coved fillets, cills, steps, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, padding over roof and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L for providing precast cement concrete 1:2:4, type B1 1:2:4 using 20 mm graded crushed stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone wallin), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc and setting in cement mortar 1:4 complete with joints to match complete all as specified and as directed. Note : Reinforcement shall be measured and paid for separately.
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4 complete all as specified & as directed.
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks or slabs, 10 cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4 in walls complete all as specified & as directed.
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20 mm graded crushed stone aggregate) as in chajja, roof projection, shelves and the like in any description for height upto 9 metres from average ground level including necessary formwork for fair finished surfaces of concrete and scaffolding complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of form work, scaffolding, safety belt, etc. (ii) Reinforcement shall be measured and paid for separately.
Supply only Integral Water Proofing Compound (ISI Marked).
Cutting chases in brick/ stone wall, pinning in, making good to facing where required and plastering in CM 1:4 to ends of edges of landing, steps, cills, lintels etc and cutting chases not exceeding 10 cm girth for concealed water tubing and similar works and making good cutting as per its original specfication complete all as directed.
M&L for cutting holes in brick/stone walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as required including making good as per its original specification without any extra cost, not exc. half brick thick (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall).
S&F Second class hard wood kiln seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as specified and as directed.
S&F factory made 35 mm thick second class hard wood plain framed panelled door shutter (any number of panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified and as directed.
S&F factory made 35 mm thick second class hard wood glazed and skeleton door shutter open rebated and prepared to receive glass, guage etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (a), kiln seasoned and chemically pressure treated, supplied and fitted to chowkats, complete all as specified and as directed.
S&F factory made Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete as specified by the manufacturer and as per directions of Engineer-in-charge.
S&F factory made 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacturer, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
S&F 200 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 100 mm size stainless steel butt hinges (ISI Marked), medium weight.
S&F 150mm size extruded aluminium alloy handles (ISI Marked), fabricated type, anodised and fixed.
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F in repairs Brass chromium plated tubular towel rail, 20mm dia, D type, 50cm long between flanges complete all as directed. Make : Prayag Cat No BA-01 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames and shutters for doors, windows and ventilators with one or more rebates including joining cleat for fixing, anodised aluminium snap on beading, neoprene gasket etc. complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed.
S&F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F mild steel screw bolts of 5-10 mm diameter of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5 cm long, with hole in each bolt for tightning of wire, complete all as specified & as directed.
S&F 10 mm dia fastner/anchor bolts 120mm long with nuts each, drilling holes in existing walls for fixing brackets to tie drying cloth wire complete all as specified & as directed.
S&F GI chicken wire mesh cut to size made to shape as ordered including fixed to walls with nails for receiving the plaster complete all as directed. Note : Weight of GI chicken wire mesh shall be 250 to 300 gm/Sqm.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
All as per serial item No. 36 here-in-before but 6 to 10 mm dia in stirrups, spacers and binders.
S&F plain mild steel wire 4.00 mm dia, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc. as directed (each line of wire to be measured) complete all as directed and as specified.
Material and labour for complete removal of existing water proofing treatment of any description or any other type of treatment over roof slab, parapets, chimney stacks, etc including cement plaster over RCC roof and cleaning the surface with wire brushes and washing with water, removing of insolvent materials and removing & depositing the debris, rubbish, etc outside MoD land, brushing neat cement slurry @ 3 Kg of cement per Sqm over the cleaned surface and provide 15mm thick screed bed/bedding layer/plaster in CM 1:3 mixed with integral Water Proofing Compound (WPC) as per manufacturer's instructions and finishing the surface even & smooth without using extra cement while the cement slurry is still green on RCC roof/parapet, provide oil bound bituminous primer @ 0.30 Kg/Sqm after bedding layer/plaster is cured with water for 7 days & completely dried, provide minimum 4mm thick APP based modified polymeric water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyester matt fabric weighing not less than 160 gms/Sqm with over laps 75 mm longitudinal direction (side laps) and 100 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed and finally finishing the top surface with one finishing coat of bituminous aluminium paint complete all as specified and as directed. Notes: (i) WPC shall be measured & paid for separately as ‘Supply only’. (ii) The work shall be carried out only through manufacturer or their authorised applicator and contractor shall submit a written guarantee of the manufacturer/authorised applicator for the effectiveness of WPT for 10 years from the date of completion of contract. (iii) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (iv) The net area of water proofing treatment shall be measured without any extra allowance for laps.
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed. Note : Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.
M&L for average 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in padding in sunken floor & the like and finished the surface even and smooth with using extra cement complete all as directed and as specified.
M&L for 16 to 18 mm thick granite slab (of any quality) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got appproved from GE before incorporation in the work.
M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm or as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got appproved from GE before incorporation in the work.
M&L for 20mm thick rendering in two layers on stone masonry surfaces or surfaces other than fair face of brick work of walls consisting of 1st layer (backing coat) of 15mm thick plaster in CM 1:6 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4, 2nd layer mixed with integral water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete, all as specified and directed. Note :- Water proofing compound shall be measured and paid for separately as 'Supply only'.
M&L for rendering 20mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work of walls mixed with WPC @ minimum 2% by weight of cement or as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as 'Supply only'.
M&L for rendering 15 mm thick in CM 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:3 on ceiling surfaces of roof projection/ chajjas finished even and smooth without using extra cement for height upto 9 metres from average ground level complete all as specified and as directed.
M&L for preparation of newly plastered / unplastered surfaces of walls & applying three coats of white wash complete all as specified and as directed.
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified and as directed.
M&L for preparation of old decorated surfaces of walls including cornices etc (plastered or unplastered) of any description, rubbing, scrapping by hand held sander / long handle sander and washing and applying one coat of oil emulsion distemper (OBD) of approved shade/tint complete all as specified and as directed.
M&L for complete removal of existing treatment by meachanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.
M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
M&L for complete removal of existing treatment by meachanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing and painted surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
M&L for two coats of fiber reinforced elastomeric liquid applied waterproofing membrane paint (‘SmartCare Damp Proof’ of Make ‘Asian Paints’ or equivalent make as approved by GE) over and including self priming coat on existing plastered surfaces including necessary preparation of surfaces complete all as per manufacturer's instructions and as directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) of size 5 to 8 cm high with thick synthetic enamel paint of approved tint over a synthetic enamel paint circle of 15 cm dia in approved tint for describing building numbers on concrete/plastered surfaces complete all as specified & as directed. Note : The font, style, matter, tint of paint & place of writing shall be as directed by the Engineer-in-Charge.
M&L for writing letters or figures (Block, Roman, Italic or Indian) of size 10 to 12 cm high with thick synthetic enamel paint of approved tint over a synthetic enamel paint circle of 30 cm dia in approved tint for describing building numbers on concrete/plastered surfaces complete all as specified & as directed. Note : The font, style, matter, tint of paint & place of writing shall be as directed by the Engineer-in-Charge.
M&L for writing letters or figures (Block, Roman, Italic or Indian) of size 10 to 12cm high with thick synthetic enamel paint of approved tint over a synthetic enamel paint rectangular base marking of size 600 mm x 450 mm in approved tint for describing periodical services done/ due details in mm/ yyyy format complete all as specified & as directed. Note : The font, style, matter, tint of paint & place of writing shall be as directed by the Engineer-in-Charge.
S&F 3mm thick figured glass, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as specified & as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of 1st quality synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of 1st quality synthetic enamel paint of approved tint all as specified & as directed.
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 15mm bore complete all as specified and as directed.
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 20mm bore complete all as specified and as directed.
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 15mm bore obtained serviceable vide serial item No. 64.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 20mm bore obtained serviceable vide serial item No. 65.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
M&L for galvanized steel water tubing medium grade of 15mm bore (ISI marked) with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 20mm bore (ISI marked) with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Supplying and laying of 15mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, elbows, unions, end pieces, etc and fixed with solvent cement fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Supplying and laying of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, elbows, unions, end pieces, etc and fixed with solvent cement fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F in repairs 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
S&F in repairs ball valve, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe or brass ferrule of 20 mm bore and fixed (minimum weight 210 gms) complete all as specified and as directed..
S&F in repairs 15mm bore bib tap with wall flange, fancy type, cast copper alloy, chromium plated screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 6806 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 15 mm bore two way bib tap fancy type, brass, chromium plated with flange and aerator, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 6812 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs health faucet ABS body with wall hook and 1 metre SS braided rubber hose pipe and wall hook mounted type complete. Make: Prayag Cat No. BEA-85 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 15 mm bore pillar tap, Swan neck, fancy type, CP cast copper alloy, with capstan heads, with long screwed shanks and fly-nuts, screwed down high pressure, screwed for iron pipe complete all as directed. Make: Prayag Cat No. 6514 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs concealed type stop valve with wall flange 15 mm bore of pipe, brass chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. Make: Prayag Cat No 6818 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 15 mm bore angle cock with wall flange, chromium plated brass, screwed both for iron pipe or brass ferrule complete all as directed. Make: Prayag Cat No. 6810 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs Soap dish, stainless steel, fixed to tiled wall with plugs and chromium plated brass screws complete.
S&F in repairs brass chromium plated shower rose 125 mm dia with or wihout swivel joint, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repairs 75 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm, fixed to wall/ ceilings or in floors etc. complete all as directed.
S&F in repairs PVC connection 15mm bore and 45cm long with two Nos of brass check nuts and washers complete all as directed.
S&F in repairs PVC flexible waste pipe for 32mm dia waste coupling complete all as specified and as directed
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed.
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed.
S&F 75 mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 110 mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 75 mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 110 mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 75 mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 110 mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F PVC (SWR) Vent cowl 75mm bore size fixed complete all as directed.
S&F PVC (SWR) Vent cowl 110mm bore size fixed complete all as directed.
S&F PVC (SWR) floor trap plain with stainless steel openable grating including jointing with solvent cement, diameter of outlet 75mm, complete all as specified & as directed.
S&F PVC (SWR) multi floor trap with stainless steel openable grating including jonting with solvent cement, diameter of outlet 75mm, complete all as specified & as directed.
S&F in repairs vitreous china oval shape counter sunk wash hand basin (white) of size 560mm x 470mm x 190mm with & including 32 mm dia PVC waste pipe and 32mm chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed complete all as specified & as directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, including P/S trap, complete all as specified & as directed.
S&F in repairs vitreous china urinal, half stall type, white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including CP brass spreader, PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia, complete all as specified and as directed.
S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as specified and as directed.
Disconnecting existing PVC water tanks fixed in any description of capacity exceeding 250 ltrs and not exceeding 500 ltrs, setting aside (or lowering if required) for repairs, cleaning and removing scale and dirts etc from tanks and from mouths of circulating pipes etc and hoisting as ordered, including reconnecting and re-fixing in same position and testing on completion complete all as directed.
Disconnecting existing PVC water tanks fixed in any description of capacity exceeding 500 ltrs and not exceeding 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning and removing scale and dirts etc from tanks and from mouths of circulating pipes etc and hoisting as ordered, including reconnecting and re-fixing in same position and testing on completion complete all as directed.
Dismantling of existing any type & any capacity water storage tank fixed in any description and S&F new 1000 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover hoisted and fixed in position where ordered and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
Dismantling of existing any type & any capacity water storage tank fixed in any description and S&F new 500 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover hoisted and fixed in position where ordered and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
M&L for providing and laying water proofing treatment on roofs of slabs / sunken floors consisting of & including the following :- (a) After preparation of surfaces, apply first layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic Polymer TAPCRETE P 151 of CICO Chemicals @ 0.253 kg/sqm. (b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with Acrylic Polymer TAPCRETE P 151 of CICO Chemicals and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment shall be taken upto 30 cm on parapet / side wall and tucked into groove in parapet / side wall all around. Notes : Equivalent product of Fosroc / Dr. Fixit / Pidilite / Sika shall be allowed as approval of GE.
M&L for application of high build polymer modified cement mortar (1:3) mixed with 6 ltrs SBR latex per bag of cement {Compressive strength after 28 days ≥ 40 N/sqmm (According to ASTM C109)} in small patch work over column/ beams/ ceilings / walls surfaces 20 to 30mm thick in two layers over a coat of bonding agent like Nitobond SBR (1 ltr SBR + 3 Kg cement) applied as per manufacturer’s instructions for height upto 15 metre from average ground level complete all as directed by the Engineer-in-Charge. Note :- SBR latex chemical shall be measured and paid for separately as ‘Supply only’.
Supply only SBR latex chemical of Make Krishna Conchem / Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian as approved by GE.
E&M Items: Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sheet metal box, terminal plates with all accessories, concealed MS box/ PVC modular box with cover suitable for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.
All as per serial item No. 112 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
All as per serial item No. 112 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
S&F in repairs modular switch, single pole, one way, 6 Amp, 1 module with all accessories complete all as directed.
S&F in repairs modular switch, single pole, one way, 16 Amp, 1 module with all accessories complete all as directed.
S&F in repairs molular socket 6 Amp, 2/3 pin combined, 2 module with all accessories complete all as directed.
S&F in repairs modular socket multipurpose 6 / 16 Amp - 2/3 pin combined, 2 module with all accessories complete all as directed.
S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.
Taking down existing light fitting of any description & fixed in any position and S&F new 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500, high quality design, aluminium extruded with decorative end caps fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. Make: Jaquar Cat No.LGLZ01X020XC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing light fitting of any description & fixed in any position and S&F new 10 Watt wall mounted 2 ft glaze LED batten, CCT 6500K, high quality design, aluminium extruded with decorative end caps fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. Make: Jaquar Cat No. LGLZ01X010XC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down carefully existing Exhaust fan of any make or size and refixing the same after minor repair work i.e. cleaning, greasing, blade leveling etc. complete and connecting with & including new 3 core 1.5 sqmm copper conductor flexible cable from ceiling rose to fan with all accessories complete all as directed.
S&F 300mm sweep, metal body, exhaust fan, AC, single phase, 230/240 V, copper winding motor, with louver shutter venti Air and connecting with & including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan including taking down existing old exhaust fan and depositing to MES store yard complete all as directed by Engineer-in-Charge. Note : Old Exhaust Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 8 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed. Make: Legrand Cat No. 5076 11 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs MCB SPN 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed. Make: Legrand Cat No. 4086 17 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed. Make: Legrand Cat No. 4085 87 to 4085 95 or equivalent in makes mentioned in Appendix 'B' here-in-after.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade cables (ISI marked), drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit (ISI marked) not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Suraj Builders
JAMNAGAR ELECTRIC AND MACHINERY CO
Sagar Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .