| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-Finance | L1 | Accepted-Finance L1 Contractor | |
| 2 | L2₹20.1 L+₹69,368 (3.57%)Rejected-Finance 11 492 IRIMPANAM TRIPUNITHURA ERNAKULAM KERALA 682309 | ERNAKULAM | KERALA | 682309 | L2 | Rejected-Finance Not L1 Contractor | |
| 3 | L3₹21.7 L+₹2.3 L (11.7%)Rejected-Finance KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | L3 | Rejected-Finance Not L1 Contractor | |
| 4 | Rejected-Technical | - | Rejected-Technical Registration not as per tender notice clause no. 1.10, Experience Certificate not as per tender notice clause no. 1.13 | |
| 5 | Rejected-Technical 1ST FLOOR BUILDING NO 49 176 SYAMA BUSINESS CENTRE NH BYPASS VYTTILA ERNAKULAM 682019 | ERNAKULAM | ERNAKULAM | KERALA | 682019 | - | Rejected-Technical Experience Certificate not as per tender notice clause no. 1.13 |
Tender Value
₹25.6 L
EMD Value
₹51,200
Closing Date
31 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Electrification of ECED faculty rooms, research lab and Seminar hall in the Old Central Library Building
2024_NITC_806866_1
Engg/EMU/JE3/0003/ECED-Old Library
Open Tender
Electrical Works
Item Rate
45 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹51,200
Yes
26 Jun 2024
10 May 2024
3 Jun 2024
10 May 2024
31 May 2024
10 May 2024
Amount
Wiring for light point/ fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring of twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required
Supplying and fixing of 20 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall / floor and making good the same in case of recessed conduit as required.
Supplying and fixing of 25 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall / floor and making good the same in case of recessed conduit as required.
Supplying and fixing of 32 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall / floor and making good the same in case of recessed conduit as required.
Supplying and drawing 3 numbers 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Supplying and drawing 3 numbers 2.5 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Supplying and drawing 3 numbers 4 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Wiring for circuit/ submain with 4 X 6 sq. mm + 2 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain with 4 X 6 sq. mm + 2 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain with 4 X 10 sq. mm + 2 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/submain wiring along with earth wire with 4 x 16 sq.mm + 2 x 6 sq.mm of FRLS PVC insulated copper conductor, single core cable with surface/ recessed suitable size medium class PVC conduit etc. as required.
Supplying and fixing 20/25 A modular DP switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin 25 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 2 Module, GI box alongwith modular base & modular switches in surface/recess etc.as required.
Supplying and fixing 3 pin 5/6 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of DLP Plastic trunking of size 150 x 50 mm with clip on partitions (2 compartments) 2 Nos 65 mm or nearest suitable width flexible cover, fitted on the wall with steel screws, cup washers etc. as required.
Supplying and fixing of flat angles in the existing DLP Plastic trunking of size 150 x 50 mm as required
Supplying and fixing of end cap in the existing DLP Plastic trunking of size 150 x 50 mm as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.
Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch on suitable size modular plate and cover plate (65 mm), including connections etc. as required on the existing DLP trunking.
Supplying and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch on suitable size modular plate and cover plate (65 mm), including connections etc. as required on the existing DLP trunking.
Supply and fixing 300 mm sweep exhaust fan with front guard working on 240 Volts AC supply, after cutting holes on wall, making good the damages, giving connections using 1.5 sq.mm 3 core round flexible copper wire, etc as required.
Supply and fixing 300 mm sweep exhaust fan with front guard working on 240 Volts AC supply, on existing exhaust fan provision, making good the damages, giving connections using 1.5 sq.mm 3 core round flexible copper wire, etc as required
Supplying and fixing of 450 mm sweep wall fan, with three speed positions,Aluminium blade and pulling cord,1350 RPM, 100 CMM air delivery (SStorm2 or compatible) giving connection as required.
Supply and fixing of box type tube fittings (Batten & T8 LED Tube), complete with side holders and 18/20 watt 4 feet T8 LED tube, Including suitable GI clamp for fixing at an angle of 45 degree. etc, as required.(T8 LED-Bajaj BLRB 18W CW LED, Batten- Bajaj BLRB-DB 118 I, or compatible).
Supply and fixing of recess mounting type (square type),1x1or nearest size of 18 W, 1500 lm, 5700K, CRI >80, Efficacy >100 lm/watt, THD <10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. (Crompton -LCTLRNE-18-CDL(1X1)or compatible) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site.
Supply and fixing of surface mounting type (square type),1x1or nearest size of 18 W, 1500 lm, 5700K, CRI >80, Efficacy >100 lm/watt, THD <10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. . (Crompton -LCTLSNE-18-FO-CDL(1X1)or compatible) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site.
Supplying and fixing 6 - 32 amps rating, 240 Volts, 'C' curve miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 32 amps rating, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 25 amps rating, 240 Volts, 'C' curve miniature circuit breaker suitable for inductive load of Four pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 25 amps rating, 240 Volts, 'C' curve miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 25 amps rating, Four pole (Three phase and neutral) 415 Volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 40 amps rating, Four pole (Three phase and neutral) 415 Volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 25 amps rating, Double pole (single phase and neutral) 240 Volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 63 amps rating, Triple pole, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 40 amps rating, four pole, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 40 amps rating, Triple pole, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 3 phase 6 way , double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB etc)
Supplying and fixing 3 phase 12 way , double door, suface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as requied.
Supplying and fixing 3 phase 8 way , double door, suface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as requied.
Supplying and fixing 3 phase 4 way (8 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 3 phase 6 way (8 + 18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 16 way, single pole and neutral Double door, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 200 A, 25 kA DPX3 250, FP MCCB (Thermal magnetic : O/L & S/C protection ) in the existing MCCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply of 1.1 kV grade 3.5C x 120 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable (as per IS) as required.
Laying and fixing of one number 1.1 kV grade Aluminium conductor XLPE insulated PVC sheathed armoured power cable of 3.5C x 120 sq.mm size, clamping on wall using suitable metal clamps spacing not exceed 50 cm etc. as required.
Supply and making end termination with brass compression gland and aluminium legs for 3.5C x 120 sq.mm (35 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.
Supply and laying one number of the 8 SWG good quality bare copper wire along the cable with connections etc. as required.
Supplying and fixing 4 way, single pole and neutral Double door, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supply and installing 225 mm width X 50 mm depth X 1.6 mm thickness size ofperforated Hot dipped galvanised iron cable tray with perfortion not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with GI suspeders including GI, bolts & nuts,etc as required.
NATIONAL ENGINEERING COMPANY
Power Care Electrical
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .