Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC AT JANTA NAGAR BOKARO THERMAL DIST BOKARO PIN 829107 | BOKARO | JHARKHAND | 829107 | ₹10.8 L Quoted ₹9.2 L | L1 | Accepted-AOC as per WO |
| 2 | L2₹10.1 LRejected-Finance | ₹10.1 L | L2 | Rejected-Finance As per TCr |
| 3 | L3₹12.0 LRejected-Finance AT PO URIMARI DISTT HAZARIBAGH JHARKHAND PIN 825311 | URIMARI | HAZARIBAGH | JHARKHAND | 825311 | ₹12.0 L | L3 | Rejected-Finance As Per TCR |
| 4 | Rejected-Technical | - | - | Rejected-Technical As per TCR |
| Sl No | Description | Qty | Unit | indra deep nayak L3 | Reliable systems L2 | M/S SINGH ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Erection of metallic pole of above 10.00 meter and upto 12.00 meter length in cement concrete 1:3:6 (1 Cement : 3 coarse sand: 6 grade stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as
required. | 40 | Nos. | 6,700 ₹2.7 L | 6,150 ₹2.5 L | 5,400 ₹2.2 L |
| 2.00 | Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc as required. (3.3KM x 214Kg/Km =706.2Kg). | 706 | kg | 90 ₹63,540 | 132 ₹93,192 | 111 ₹78,366 |
| 3.00 | Erection of ACSR conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc as required.
(3.3KM x 394Kg/Km =1300Kg). | 1,300 | kg | 90 ₹1.2 L | 188 ₹2.4 L | 161 ₹2.1 L |
| 4.00 | Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm x 110 mm) G.I bolts, Nuts, and washers, coach screws etc .as required | 120 | Set | 900 ₹1.1 L | 225 ₹27,000 | 200 ₹24,000 |
| 5.00 | Supplying and erection of 100 mm x 80 mm pin
insulator complete with G.I spindle and nuts etc.
as required. | 60 | Set | 600 ₹36,000 | 101 ₹6,060 | 91 ₹5,460 |
| 6.00 | Erection of LV/MV shackle/pin insulator etc. as
required | 60 | Set | 450 ₹27,000 | 60 ₹3,600 | 51 ₹3,060 |
| 7.00 | Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 Kg per meter) cross arm for 2 wire over head line complete with clamps, bolts, Nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting
with primer and finished paint as required. | 20 | Set | 900 ₹18,000 | 611 ₹12,220 | 560 ₹11,200 |
| 8.00 | Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 Kg per meter) cross arm for 4 wire over head line complete with clamps, bolts, Nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting
with primer and finished paint as required | 20 | Set | 750 ₹15,000 | 1,012 ₹20,240 | 880 ₹17,600 |
| 9.00 | Erection of angle iron/ channel iron cross arm on
wood/RCC/PCC/steel tubular/rail pole etc. as
required | 45 | Nos. | 850 ₹38,250 | 191 ₹8,595 | 160 ₹7,200 |
| 10.00 | Erection of disc/ pin insulator for 11 KV over
head line as required. | 20 | Set | 950 ₹19,000 | 190 ₹3,800 | 210 ₹4,200 |
Tender Value
₹12.6 L
EMD Value
₹15,800
Closing Date
17 Oct 2025, 6:00 pmClosed
PE(EnM) Officer C-SND Colliery
PE(EnM) Office C-SND Colliery
Day to day annual maintenance/repairing of 11KV,3.3KV,550V and 440V ,220V OH line on as and when required basis for a period of one year for Central Saunda Colliery.
2025_CCL_345115_1
PE(EnM)/C-SND/eTender/25-26/06
Open Tender
Electrical and Maintenance Works
15 days
C-Saunda Colliery
please refer Tender documents
2 documents required · 2 mandatory
₹15,800
27 Mar 2026
6 Oct 2025
18 Oct 2025
7 Oct 2025
17 Oct 2025
7 Oct 2025
7 Oct 2025 - 11 Oct 2025
Amount
Erection of metallic pole of above 10.00 meter and upto 12.00 meter length in cement concrete 1:3:6 (1 Cement : 3 coarse sand: 6 grade stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required.
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc as required. (3.3KM x 214Kg/Km =706.2Kg).
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc as required. (3.3KM x 394Kg/Km =1300Kg).
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm x 110 mm) G.I bolts, Nuts, and washers, coach screws etc .as required
Supplying and erection of 100 mm x 80 mm pin insulator complete with G.I spindle and nuts etc. as required.
Erection of LV/MV shackle/pin insulator etc. as required
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 Kg per meter) cross arm for 2 wire over head line complete with clamps, bolts, Nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 Kg per meter) cross arm for 4 wire over head line complete with clamps, bolts, Nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required
Erection of angle iron/ channel iron cross arm on wood/RCC/PCC/steel tubular/rail pole etc. as required
Erection of disc/ pin insulator for 11 KV over head line as required.
SErection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/rail/PCC pole 11/22/33 KV as required
Supplying and erection of galvanised stay set for 11 KV over head line complete with 19/20 mm dia x 1.8 meters long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm x 600 mm), 7/4.00 mm dia G.I stay wire and 11KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coars sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required.
Connecting / disconnecting 3.3Kv 3phase power cable from OH line as required
Disconnecting/ connecting 3.3 Kv 4 phase jumper wire between overhead line as required
Dismantling/installation of gang operating system (isolator) 400Amp for 3.3Kv OH lines as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I wire cross arms, insulators etc. as required. Rabbit conductor = 03Km x 214 Kg/Km = 642.00 Kg Dog conductor = 03Km x 394 Kg/Km = 1182.00 Kg Total = 1824.00Kg
Dismantling of pole/ street light standard/ strut embedded in cement, concrete foundation etc as required
Loading transporting and un loading of dismantled materials from site to store (truck will be provided by department).
Loading Unloading and transporting of poles (60 nos) (truck will be provided by department).
Total impact of GST for the purpose of CTC
Reliable systems (BID ID -1191224)
indra deep nayak (BID ID -1190322)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Document
2.37 MB
BOQ
BOQ • 0.29 MB
Download all tender documents and submit your bid