Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 CrAccepted-AOC 101 1ST FLOOR PATEL CHAMBERS 13 MATHEW ROAD GIRGAON MUMBAI 400004 | MUMBAI | MUMBAI | MAHARASHTRA | 400004 | ₹17.5 Cr | L1 | Accepted-AOC Financially qualified and declared L1 (Lowest) bidder |
| 2 | L2₹36.5 CrRejected-Finance NO 6 1 12TH MAIN OPP MOUNT CARMEL COLLEGE VASANTH NAGAR BENGALURU 560052 | 560052 | ₹36.5 Cr | L2 | Rejected-Finance Financially Rejected as the firm not being the lowest in price. |
| 3 | L3₹42.5 CrRejected-Finance FIRST FLOOR NEW DOOR NOS 57 59 61 63 DOWLATH TOWERS TAYLORS ROAD KILPAUK CHENNAI TAMIL NADU 600010 | CHENNAI | TAMIL NADU | 600010 | ₹42.5 Cr | L3 | Rejected-Finance Financially Rejected as the firm not being the lowest in price. |
| 4 | Rejected-Technical SALT LAKE KOLKATA WEST BENGAL 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | - | - | Rejected-Technical Technically Rejected |
Tender Value
₹17.6 Cr
Closing Date
16 Mar 2022, 12:00 pmClosed
The Controller of Stores
Dharitri, GN-40, Sector V, Salt Lake, Kolkata
SETTING UP OF A PROJECT FOR CREATION OF AN INFORMATION AND COMMUNICATION TECHNOLOGY(ICT) INFRASTRUCTURE FOR NATIONAL LANDSLIDE FORECASTING CENTRE (NLFC_
2021_GSI_660560_1
121/18/COS/PUR/APMD/26B-2021
Open Tender
Information Technology
365 days
Dharitri, GN-40, Sector V, Salt Lake, Kolkata
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
Exempted
Dharitri, GN-40, Sector V, Salt Lake, Kolkata
11 Jan 2023
8 Dec 2021
22 Mar 2022
8 Dec 2021
16 Mar 2022
13 Jan 2022
8 Dec 2021 - 16 Mar 2022
23 Dec 2021
SETTING UP OF A PROJECT FOR CREATION OF AN INFORMATION AND COMMUNICATION TECHNOLOGY(ICT) AND THE INFORMATION TECHNOLOGY (IT) INFRASTRUCTURE FOR “NATIONAL LANDSLIDE FORECASTING CENTRE (NLFC)” with 01 Year Standard Warranty and 06 Years Comprehensive Annual Maintenance Contract under Turnkey Project (CAPEX-D1 model)
Modular, 40 KVA, 3 phase 400V, 12-pulse on-line Uninterruptible power supply (UPS); parallel bank of high performance, sealed maintenance free battery with backup for 60 minutes. (Ref: Sections 6.2.2. and 6.2.3, and 7.1.1 (CAPEX-D1)
50 KVA Diesel Generator with Automatic transfer switch; SNMP monitoring system; concrete pad and with diesel tank of minimum 500 ltrs capacity (Ref: Sections 6.2.4 and 7.1.2) (CAPEX-D1)
Earthing and Grounding for all Electrical installation with high conductive copper plate (Ref: Sections 6.2.5 and 7.1.3 (CAPEX-D1)
Partitions, walls, doors etc to be constructed as per the layout design in sec 9.1 (As per Specs require for Room nos. 507 and 508)(Ref: Sections 6.2.6 and 7.2) (CAPEX-D1)
Raised floor for the equipment room as per the layout in Sec 9.1 (Approx. 400 sq,ft +/- 10%) (Ref: Sections 6.2.6 and 7.2)(CAPEX-D1)
False Ceiling for the entire floor space mentioned in layout Sec 9.1 (Approx. 4000 sq. ft. +/- 10% in Room 507 and 508) (Ref: Sections 6.2.6 and 7.2) (CAPEX-D1)
Name Board As specified outside the rooms, viewed from Corridor using digital tablets, LED lights (Ref: Sections 6.2.6 and 7.2) (CAPEX-D1)
All round and covering on ceiling of Two (02) DG Set space Covering using designed and structured BlueScope Steel sheet, including concrete platforms (Ref: Sections 6.2.4, 6.2.6 and 7.1.2) (CAPEX-D1)
Supply all required components mentioned in the specifications for Building Management system for Approx. 3500 sq.feet +/- 10% in Room 507 and 508 (Ref: Sections 6.2.7 and 7.3) CAPEX-D1
All the cables, Cable trays, ducting shall be according to the specifications and connecting all the Racks and rooms in DC & NLFC in Room 507 and 508 (Ref:Sections 6.2.8, 6.2.9 and 7.3.5, 7.3.6, and 7.3.7)
All LED lights as required (As per specs for 4000 sq feet areas in both room nos 507 and 508) (Ref:Section 7.1.4) CAPEX-D1
HVAC for Server Room, Self-contained 220V/50Hz High Precisions; HVAC unit; dual refrigeration – Complete System with all accessories or Equivalent including Sensors for Water, humidity, temperature as mentioned in specifications (2 x 4 ton For 400 sq. feet area (approx.)(Ref:Sections 6.2.10 and 7.2, 7.3 and 7.4) Capex-D1
2.5 Tonne False ceiling AC with required accessories for the entire facility of 3500 sq. feet in Room Nos. 507 and 508 excepting Server Room (As required to manage and cool 4000 sq. feet space and Electrical Room) (Ref:Sections 6.2.10 and 7.2, 7.3 and 7.4) Capex D1
Complete Fire Suppression system including accessories as per the specs (1 set covering all facilities of NLFC in Room Nos. 507 and 508)(Ref:Sections 6.2.11,7.2 and 7.3)CAPEX-D1
Physical Security , All the devices required for physical security of DC as per specs provided (1 set covering all facilities of NLFC in Room Nos. 507 and 508) (Ref:Sections 6.2.12 and 7.6) CAPEX-D1
CCTV Surveillance systems, Minimum of 8 CCTV Cameras, each one for all the rooms available in the DC layout; two in equipment room; and including all required monitoring devices and accessories (1 set covering all facilities of NLFC in Room Nos. 507 and 508) (Ref:Sections 6.2.12 and 7.6) CAPEX-D1
Racks, Standard 42U Racks to accommodate all the IT and Non IT infrastructure to be installed in Racks (Ref:Sections 6.2.13 and 7.7.1) CAPEX-D1
Description of Work / Item(s)
SETTING UP OF A PROJECT FOR CREATION OF AN INFORMATION AND COMMUNICATION TECHNOLOGY(ICT) AND THE INFORMATION TECHNOLOGY (IT) INFRASTRUCTURE FOR “NATIONAL LANDSLIDE FORECASTING CENTRE (NLFC)” with 01 Year Standard Warranty and 06 Years Comprehensive Annual Maintenance Contract under Turnkey Project (CAPEX-D2 model)
Blade Chasis (Ref: Section 7.7.2) (CAPEX-D2)
Blade Server; Each blade shall have a minimum of two (2) x86-64 architecture and latest & highest generation Processors with minimum 2.1GHz & 20 cores per socket. (Ref: Section 7.7.3) (CAPEX-D2) (see corrigendum)
Networking Switch,SAN of 50 TB Data Storage (Ref: Section 7.7.9) (CAPEX-D2)
Networking Switch, Server Firm Core Switch of 12 port number 10G port and 12 x 100/1000 Mbps Ethernet, (Ref: Section 7.7.5) (CAPEX-D2)
Networking Switch, L2/L3 Switch of 48 port 100/1000Mbps Ethernet with 4 number SFP+ with modules (Ref: Section 7.7.7) (CAPEX-D2)
Networking Switch, L2/L3 Switch of 24 port 100/1000Mbps Ethernet with 4 number SFP+ with modules, (Ref: Section 7.7.6) (CAPEX-D2)
Next Generation Firewall with data security, (Ref: Section 7.7.10) (CAPEX-D2)
Router(Ref: Section 7.7.4) (CAPEX-D2)
Storage should provide minimum usable storage of 10TB on SSD and 40TB on SAS 10k Drives post RAID 6/DP/equivalent settings , scalable to 100 TB in future, (Ref: Section 7.7.8) (CAPEX-D2)
Desktop Workstations in Room No. 508, (Ref: Section 7.7.12) CAPEX-D2
All-in-one-PC with dual monitors (Ref. Section 7.7.15) CAPEX-D2
Mobile Workstation (Ref. Section 7.7.13) CAPEX-D2
LED 4k TV 65 inch or above for forecasting room for Region/ State wise display before the main U-shaped Conference Table (Ref. Section 7.7.14) CAPEX-D2
LED 4k TV 65 inch or above for DC control observation (Ref. Section 7.7.14 and 6.3.10) CAPEX-D2
Interactive LED 4K Touchscreen Display 86 inch for Mini Conference Room attached with Director's room (Ref. Section 7.7.16) CAPEX-D2
Collaborative Meeting Board For Conference/ Meetings, (Ref: Section 7.7.22) CAPEX-D2
Network Printers (BXW), For Room Nos. 507 and 508, (Ref: Section 7.7.17) CAPEX-D2
Laser Jet Duplex Printer For Director’s room (Ref: Section 7.7.18) CAPEX-D2
Colour Printer For Director’s room, (Ref: Section 7.7.19) CAPEX-D2
IP Telephony System with 10 Hard and 30 Soft IP Phones (Ref: Section 7.7.23, 7.2.24 and 7.2.25) CAPEX-D2
VC On premise Video-conferencing Unit + 7 year Extended Warranty (Ref: Section 7.7.21) Capex-D2
Multi-factor authentication solution, (Ref: Section 7.7.11) CAPEX-D2
Description of Work / Item(s)
SETTING UP OF A PROJECT FOR CREATION OF AN INFORMATION AND COMMUNICATION TECHNOLOGY(ICT) AND THE INFORMATION TECHNOLOGY (IT) INFRASTRUCTURE FOR “NATIONAL LANDSLIDE FORECASTING CENTRE (NLFC)” with 01 Year Standard Warranty and 06 Years Comprehensive Annual Maintenance Contract under Turnkey Project (CAPEX-D3 model)
Virtualization software for 4 servers of 2 socket each with management software (8 licenses for 4 Servers), (Ref:Section 6.3.4) (CAPEX-D3)
Enterprise GIS Server, (Ref:Section 6.3.7 and 7.7.26) (CAPEX-D3)
Image Processing and Remote Sensing Desktop Version, (Ref:Section 6.3.7) (CAPEX-D3)
DASHBOARD, Design ,Development and implementation of Portal and Dashboard for Decission support system of LEWS-Region software system , Operation and Maintenance (1 lump sum) (Ref:Section 6.3.7) (CAPEX-D3)
Web Portal and Database, Cost of Application and Portal software, Enterprise Database and Backup software (1 lump sum),(Ref:Section 6.3.8) (CAPEX-D3)
Mobile App Development, Operation and Maintenance (1 lump sum), (Ref:Section 6.3.8) (CAPEX-D3
Desktop GIS - This should be from same make of Enterprise GIS server, (Ref:Section 6.3.7)(CAPEX-D3)
Linux Operating System with Unlimited VM (4 with unlimited VM), (Ref:Section 6.3.4) (CAPEX-D3)
Data sharing solution over web application, Https:/ FTTPS Web Based solutions for data sharing, (Ref:Section 6.3.4) (CAPEX-D3)
Cloud based meeting, training, and event solutions (5 host licenses for 7 years), (Ref:Section 7.7.20) (CAPEX-D3)
Description of Work / Item(s)
SETTING UP OF A PROJECT FOR CREATION OF AN INFORMATION AND COMMUNICATION TECHNOLOGY(ICT) AND THE INFORMATION TECHNOLOGY (IT) INFRASTRUCTURE FOR “NATIONAL LANDSLIDE FORECASTING CENTRE (NLFC)” with 01 Year Standard Warranty and 06 Years Comprehensive Annual Maintenance Contract under Turnkey Project (CAPEX-D4 model)
Furniture for Front office, Modular furniture including table and cabinet, LAN/ Electrical ports, Leather or vinyl Couch, 3 person for waiting area, chair for front office executive, ergonomic chairs, storage cabinet including all accessories , (Ref:Section 7.8.8) (CAPEX-D4)
Furniture for SI’s room, Modular furniture including table and cabinet, LAN and Electrical ports, Chair for SI, Leather or vinyl Couch, 3 person, ergonomic chairs, storage cabinet including all accessories, (Ref:Section 7.8.8) (CAPEX-D4)
Furniture for Director’s room, Modular furniture including executive table and cabinet, Executive Chair for Director, all electrical/ LAN Ports, Leather couch, 3 person, ergonomic chairs, storage cabinet including all accessories , (Ref:Section 7.8.8) (CAPEX-D4)
Furniture for Mini Conference room and chairs, Modular furniture including conference table with electric and LAN port; ergonomic chairs 10 nos; storage cabinet; white board including all accessories (10 Seater), (Ref:Section 7.8.8) (CAPEX-D4)
Furniture for Operations room & R&D Sitting area, Modular furniture with Table with provision for electrical and LAN ports, ergonomic chairs, Storage cabinet including all accessories (15 seater (including both rooms 507 and 508)(Ref:Section 7.8.8)(CAPEX-D4)
LEWS Forecast Control Area U shaped work table cum conference facility table, LAN/ Electrical ports, Modular furniture, ergonomic chairs, Storage cabinet in-built including all accessories (10 seater on both sides with 5 each and 3 on the other side (upper part of U); see Fig. 10), (Ref:Section 7.8.8)(CAPEX-D4)
Furniture in Pantry, Small dining table with four chairs, one table for Cooking, One storage cabinet For Pantry Room in Room no. 507 (As required), (Ref:Section 7.8.8) (CAPEX-D4)
Refrigerator (4-Star and above), 275 litre Frost Free, (Ref: Section 7.8.1) (CAPEX-D4)
Microwave Oven(26 lit. capacity), (Ref: Section 7.8.2) (CAPEX-D4)
Induction Oven(1500 watt), (Ref: Section 7.8.4)(CAPEX-D4)
RO+UV Filter, (Ref: Section 7.8.6) (CAPEX-D4)
Coffee Maker, (Ref: Section 7.8.3)
Description of Work / Item(s)
SETTING UP OF A PROJECT FOR CREATION OF AN INFORMATION AND COMMUNICATION TECHNOLOGY(ICT) AND THE INFORMATION TECHNOLOGY (IT) INFRASTRUCTURE FOR “NATIONAL LANDSLIDE FORECASTING CENTRE (NLFC)” with 01 Year Standard Warranty and 06 Years Comprehensive Annual Maintenance Contract under Turnkey Project (OPEX-D1, OPEX-2, OPEX-D3, OPEX-D4, OPEX- D5 and OPEX D-6 model)
Cost of IT Resources in application build and development phase till Go-live, Cost of building the NLFC IT system with Mobile Apps for Go-live and commissioning phase, (Technical (IT and Non-IT) resources under Operational Expenses), (OPEX-D1 , 14.1)
Cost of IT Professional Services during Warranty period (till end of 1st Year after go-live) (Technical (IT and Non-IT) resources under Operational Expenses), (OPEX-D3 14.3) (Ref: Chapter-7)
Cost of IT Professional Services and Services for the entire O&M period of 6 years, (Technical (IT and Non-IT) resources under Operational Expenses), (OPEX-D5, 14.5) (Ref: Chapter-7)
Cost of Data Centre Non-IT Maintenance Charges on 24X7 during development phase till Go-live, (OPEX-D2, 14.2) (Ref: Chapter-7) (See Corrigendum)
Cost of Data Centre Non-IT Maintenance Charges on 24X7 during during Warranty period (till end of 1st Year after go-live) (OPEX-D4, 14.4) (Ref: Chapter-7) (See Corrigendum)
Cost of Data Centre Non-IT Maintenance Charges on 24X7 for the Entire O&M Period of 6 Years (OPEX-D6, 14.6) (Ref: Chapter-7) (See Corrigendum)
Description of Work / Item(s)
SETTING UP OF A PROJECT FOR CREATION OF AN INFORMATION AND COMMUNICATION TECHNOLOGY(ICT) AND THE INFORMATION TECHNOLOGY (IT) INFRASTRUCTURE FOR “NATIONAL LANDSLIDE FORECASTING CENTRE (NLFC)” with 01 Year Standard Warranty and 06 Years Comprehensive Annual Maintenance Contract under Turnkey Project (OPEX-D7, OPEX--D8 and OPEX-D9 model)
CAMC of all IT hardware for 6 years (Technical (IT) resources under Operational Expenses), (OPEX-D7, 14.7)
CAMC of all non-IT equipments for 6 years (Technical (Non-IT) resources under Operational Expenses), (OPEX-D8, 14.8)
AMC of all IT software for 6 years, Cost of all IT software for 6 years, (OPEX-D9, 14.9)
RailTel Corporation of India Ltd
INSPIRISYS SOLUTIONS LIMITED
RailTel Corporation of India Ltd
INSPIRISYS SOLUTIONS LIMITED
RailTel Corporation of India Ltd
INSPIRISYS SOLUTIONS LIMITED
SCS Tech India Private Limited
INSPIRISYS SOLUTIONS LIMITED
INSPIRISYS SOLUTIONS LIMITED
RailTel Corporation of India Ltd
RailTel Corporation of India Ltd
INSPIRISYS SOLUTIONS LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid