Chief Officer, Una Nagarpalika, Una
PROVIDING, SUPPLYING AND INSTALLING OF LED STREET LIGHT ON GIR GADHDA ROAD AADHAR MALL TO SUGAR FACTORY WELL UNA, DIST. :- GIR SOMNATH
351681
UNANP/STREETLIGHT/T 44-04/R00
Open
Civil - All
Works
Gir Somnath
3 documents required · 3 mandatory
₹900
Chief Officer, Una Nagarpalika, Una
₹12,471
3 Oct 2026
3 Oct 2026
3 Oct 2026
17 Oct 2026
3 Oct 2026
Name of work : GPROVIDING, SUPPLYING AND INSTALLING OF LED STREET LIGHT ON GIR GADHDA ROAD AADHAR
MALL TO SUGAR FACTORY WELL UNA, DIST. :- GIR SOMNATH
Item Quantities Item Descrption Estimated Rates Unit Total Amount
Item Quantities Item Descrption Estimated Rates Unit Total Amount
No. Estimated according to
but may be in Figure in Words estimated
more or less quantities.
1 Supplying and erecting Flexible PVC insulated multi strand
multi core 1.1 kv grade ISI marked copper wires of
following size to be erected as directed. Rupees Ninety Seven and
208.58 (h) 2.50 Sq.mm 3 core round PVC sheathed 97.97 Ninety Seven Paise Mtr.
2 Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved
or embossed 160 to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over- Rupees Six Thousand Six
voltage protection. Hundred Ninety Five and
22.00 (v)above 120 to 160 watts Cat-lll 6695.29 Twenty Nine Paise Ea.
3 Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 25 KA.
at 415 V,having normal current rating up to 25 A to 100A.
with Fixed thermal & magnetic release suitable to work on
A.C. supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S. Rupees Six Thousand Seven
housing. Hundred Ninety and Twenty
2.00 ICS=100% of ICU only Cat III 6790.23 Three Paise Ea.
4 providing and erecting Miniature circuit breaker single pole
6A to 25A suitable to operate on 240 V A.C. system and
having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark Cat.III Rupees One Hundred Twenty
22.00 123.22 Three and Twenty Two Paise Ea.
5 Providing & erecting 415V MCB Four Pole Switch for
Lighting Load (B curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following
Rupees Six Hundred Thirty
(a) 6 to 32 Amp. Cat.III
2.00 637.31 Seven and Thirty One Paise Ea.
6 Plastic enclosure fitted with DIN rail suitable for Rupees Fifty Two and Fifty Two
0.00 incorporating One / Two nos. MCB 52.52 Paise Ea.
7 Plastic enclosure fitted with DIN rail suitable for Rupees One Hundred Eight and
4.00 incorporating Three /Four nos. MCB 108.07 Seven Paise Ea.
8 Providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on 3 phase and neutral 415V,50Hz. having
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component for
following Max. rating erected as directed. Rupees Two Thousand Nine
(ii) 40Amps. FP Cat. III Hundred and Seventy Two
2.00 2900.72 Paise Ea.
9 Providing and erecting Pipe type earthing having
cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit Rupees Three Hundred Sixty
22.00 complete with necessary 8 SWG earth wire. 368.65 Eight and Sixty Five Paise Ea.
10 For using salt and charcoal / coke as required for pipe type
earthing. Rupees One Hundred Seventy
22.00 171.70 One and Seventy Paise Ea.
11 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
cable multistrand / Solid Aluminium conductor for 1.1 KV.
to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables
Rupees One Hundred Sixty
(C) 4 core 10 Sq. mm
660.00 168.67 Eight and Sixty Seven Paise Mtr
12 Making trench in soft soil of suitable width of 90 cm deep
for laying cable or locating the fault all over the run and
back filling the same and making the surface as normal Rupees Fifty Five and Fifty Five
550.00 ground. 55.55 Paise Mtr
13 Providing & laying approved make Double walled
corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable Rupees Seventy Three and
660.00 (B)63mm outer dia 73.73 Seventy Three Paise Mtr
14 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables. Rupees Thirty Eight and Thirty
2.00 (C) 2 to 4 core 10 Sq. mm 38.38 Eight Paise Ea.
15 Solder less crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
176.00 6.06 Rupees Six and Six Paise Ea.
16 Supply of approved make frp/grp pole having followiing
specifications :
FRP/GRP pole made by centrifugal moulding process using
thermoset resin polyester/epoxy resin system having
minimum glass content 45.0%.The pole should be in one
pieceand tapered round in shape,having smooth outside
surface finish and should be totally fre from corrosion as
well as non conductive and shock proof. Pole should be
with FRP/GRP base bracket dully fabricated from
metal(M.S) and dully claded with FRP/GRP material to avoid
any metal exposer and painted with PU paint.
Pole should mechanical properties i.e 1. Specfic gravity
(ASTM D 792) 1.3‐1.8 Kg/m3, 2. Glass Content % by
weight (ASTM D 2584) 45.0 ‐55.0%, 3. Water absorption
<0.5%, 4. Tensile Strength(ASTM D 638) 200+/‐50Mpa,
Flexural strength (ASTM D 790) 250+/‐50Mpa,
Compressive Strength (ASTM D 695) 200+/‐50MPa, 7. Yeild
Strength(ASTM D638) 250 +/‐50MPa.
Pole should be flame retardant as per IS 6746.Resin used
shall be UV resistance and pigmented. Pole should be
painted with first coat of epoxy primer and then two coat of
weather resistance polyurethen paint to ensure proper
addhesion of the paint.Minimum thickness shall be 80 to
100 micron.Defelection of the pole shall not exceed more
10.0 % of the length of the pole for the given load.Pole
should be generally made as per the dimensional
data,performance criteria and some interchagebility
features of poles
as per the standard ANSI C123.20 latest version of ASTM D
923/01 including cable termination box with necessory
accessories.The size of pole and type of installation with
foundation , Anchor Base & Internal junction box as per the
manufacturer details and site requirement .
(3) 'B' class (Heavy Duty) frp/grp pole suitable for base
[G] Overall Length of 9.0 meter, Average thickness : 9mm,
Top/Bottom Ouside Dia. 76/228mm +/‐2.Weight of Pole
59.0 Kg approx. (Without base) Metal Anchor Base dully frp Rupees Thirty Five Thousand
claded (Size : 405 Ø * 18mmthk , Mounting hole PCD Three Hundred Sixty Three and
22.00 350mm * 6 nos. of 20 Ø hole) 35363.13 Thirteen Paise Ea.
17 Providing Aluminium arm bracket of having 2 sets of
suitable SS304 hardware for fixing the brackets & spread of Rupees Two Thousand One
1.2 Mtr (Suitable for 89 to 114 mm pole top dia) (A) Single Hundred Eighty Six and Sixty
22.00 arm bracket 2186.65 Five Paise Ea.
18 Supplying & erecting IP 55 grade following size section
pillar fabricated from joint less M.S. Sheet with angle iron
legs made from jointless M.S. Angle with cable clamps to be
buried in ground to have appropriate erection to work
uniform until erected with cement concrete foundation and
45 cm high bricks work finishing with plaster etc. hinged
double door internally supported on both side,
with internal and outside looking arrangement with look
and keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two
Nos. one is welded and other with nut and bolt for erecting
Bakelite sheet. Painting the Section Pillar inside and out
side with three tank powder coated paint. section pillar
roof should be without joint with water leakage proof &
tested as per IP 55 test & followed by IS 2147 of
(A) 150 X 90 X 75 cm section pillar fabricated from 14 Rupees Sixteen Thousand Six
Gauge MS Sheet with angle iron legs 95 cm long made from Hundred Ninety One and
1.00 40 X 40 X 6 mm thick MS angle. 16691.26 Twenty Six Paise Ea.
19 Supplying and erecting HYLAM sheet on existing angle iron Rupees Two Thousand Three
frame.for following thickness Hundred Eleven and Eighty
1.80 (F) 12mm 2311.89 Nine Paise sq.mtr
20 Supplying & erecting approved make time switch with
single pole air break contacts suitable for
V.15/16A.complete with self starting motor driven clock
‘ON’ &’ OFF’ automatic arrangement at any predetermined
time during each 24 hours,With nickel cadmium Rupees Two Thousand Three
rechargeable battery backup erected as directed. Hundred Fifty Four and Thirty
1.00 2354.31 One Paise Ea.
21 Supplying & erecting power contactor ,AC3 duty for time Rupees Two Thousand Seven
switch complete erected as per direction Cat III Hundred Eighty Two and Fifty
1.00 (D) 4 pole 440V 40 Amp. 2782.55 Five Paise Ea.
One percent of the Estimated cost of work put to tender shall be recovered from the running bills of the contractor as testing charges,
after deducting the cost of material proposed in scheduled-A at basic rate. One percent labour cess will be deducted from contractor’s
I/ We am/are willing to carry out the work at _____________________% above / below _____________________________%
(should be writtern in figure and words)
below / above the estimated rates mentioned above amount of my / our tender works out as under :-
Estimated amount put to tender : Estimated amount put to tender :
Signature of contractor Chief Officer
UNA NAGARPALIKA
1) All the work shall be carried out as per MOST specification and specification on the division or as directed.
2) Rates quoted includes clearance of site (prior to commencement of work and at its closed) in all respects and held gross for under all
conditions, site moisture weather etc.
3) In RCC item when there is change in grade of concrete mix or change in consumption of cement as per actual mix design then the difference in
consumption of cement shall be deducted from the rate of original item valued at the star rate as mentioned in tender. However no extra
payment shall be made for use of additional Quantity of cement as per actual concrete mix design. Concrete mix design shall be done in GERI
laboratory only.
4) The Contractor shall exhibits a board as per Govt. circular No. 2DK – 3277 / 1657 N Dt. 26–01-73 with detail of specification and details of
work and amount involved at site without any payment as directed by the Engineer in charge.
5) Testing of materials be as per statement attached with the Specifications, the materials shall be tested in G.E.R.I. Bill for testing shall be paid
by the Executive Engineer and 1% of the (one percent) of amount put to tender after shall be recovered from the running account bills of the
works. (As per G.R. (R&B) Deptt., No. TNC/1085/4/C dtd. 20.12.91.
6) The contractor shall quote even "NIL" if no reduction is proposed.
7) One precent of estimated cost put to tender for this work shall be recovered from the contract payments as "LABOUR CESS". In terms of the
Gujarat Government Gazette Extra ordinary dated 12.12.04. Implementation of building and other construction workers regulation of
equipments and conditions of service Act-1996)
8) Photographs of before work and after work will be submitted by the contractor at the time of each bill submission.
9) The contractor is solely responsible to bare all applicable taxes. Excl GST etc. and department will not entertain any contractor representation
to reimburse any financial burden due to applicable taxes :excl. GST etc.
Signature of contractor Chief Officer
UNA NAGARPALIKA
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01 SBD.pdf
02 Mile Stone Dates and Tender Nivida.pdf
03 Schedule-B.pdf
04 Qualification Criteria.pdf
05 Material Testing Schedule.pdf
06 Specification Index.pdf
07 Details of Work.pdf
08 Paripatra Part 2.pdf
08 Paripatra part 1.pdf
09 LED light Specification.pdf
10 BUILDING SPECIFICATIONS PART 1.pdf
10 BUILDING SPECIFICATIONS PART 2.pdf
11 Revise Vendor List.pdf
12 MAKE LIST.pdf
13 ELECTRIC SPECIFICATION.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .