Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.6 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND BEING LOWEST BIDDER | |
| 2 | L2₹53.6 L+₹2.9 L (5.62%)Rejected-Finance | L2 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER | |
| 3 | L3₹55.3 L+₹4.6 L (9.12%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER | |
| 4 | L4₹55.9 L+₹5.2 L (10.3%)Rejected-Finance INDORA TEHSIL INDORA DISTT KANGRA HIMACHAL PRADESH | KANGRA | HIMACHAL PRADESH | 175013 | L4 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Shri Electrical Enterprises L1 | M/s R K Enterprises L3 | SN TECHNO CONSTRUCTIONS L2 | Chamunda construction company L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material & Labour for seven stage and sterilization of inside the RCC overhead tank reservior of capacity 5,000 gallons upto height 25 mtr through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 5 | Each job | 19,500 ₹97,500 | 35,000 ₹1,75,000 | 15,000 ₹75,000 Lowest | 27,315 ₹1,36,575 |
| 2.00 | Material & Labour for seven stage and sterilization of inside the RCC overhead tank reservior of capacity 50,000 Gallons at 15 to 20m staging through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 6 | Each job | 67,500 ₹4,05,000 | 75,000 ₹4,50,000 | 70,000 ₹4,20,000 | 61,300 ₹3,67,800 Lowest |
| 3.00 | Material & Labour for seven stage and sterilization of inside the RCC overhead tank reservior of capacity1,00,000 Gallons at 15 to 20m staging through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 10 | Each job | 71,000 ₹7,10,000 Lowest | 83,000 ₹8,30,000 | 75,000 ₹7,50,000 | 87,000 ₹8,70,000 |
| 4.00 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 1,50,000 Gallons at 15 to 20m staging through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 3 | Each job | 90,000 ₹2,70,000 | 75,000 ₹2,25,000 Lowest | 87,000 ₹2,61,000 | 89,000 ₹2,67,000 |
| 5.00 | Material & Labour for seven stage and sterilization of inside the RCC overhead tank reservior of capacity 2,00,000 Gallons at 12m to 18m staging through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 2 | Each job | 1,07,000 ₹2,14,000 | 90,000 ₹1,80,000 Lowest | 1,11,500 ₹2,23,000 | 90,000 ₹1,80,000 Lowest |
| 6.00 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 15000 ltr through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 7 | Each job | 15,000 ₹1,05,000 | 10,000 ₹70,000 Lowest | 10,000 ₹70,000 Lowest | 17,315 ₹1,21,205 |
| 7.00 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 10000 gallons through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 10 | Each job | 17,000 ₹1,70,000 Lowest | 25,500 ₹2,55,000 | 21,000 ₹2,10,000 | 23,000 ₹2,30,000 |
| 8.00 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 60000 gallons through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 2 | Each job | 47,500 ₹95,000 | 65,150 ₹1,30,300 | 37,000 ₹74,000 Lowest | 67,500 ₹1,35,000 |
| 9.00 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 1,00,000 gallons through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 2 | Each job | 67,000 ₹1,34,000 | 75,300 ₹1,50,600 | 60,000 ₹1,20,000 Lowest | 75,000 ₹1,50,000 |
| 10.00 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 1,50,000 gallons through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 4 | Each job | 83,000 ₹3,32,000 | 95,730 ₹3,82,920 | 77,000 ₹3,08,000 Lowest | 97,000 ₹3,88,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
25 May 2026, 6:00 pmClosed
GE (ARMY) NO 2 JOHDPUR
Military Engineer Services, Garrison Engineer (Army) No 2 Jodhpur, Multan Lines, Army Area Jodhpur -342010
SERVICING / MAINTENANCE AND CLEANING OF OVER HEAD TANKS AND UG SUMPS OF WATER SUPPLY AND ALLIED WORKS AT ALL PUMP HOUSE IN ARMY AREA JODHPUR AS PER CPP SER NO 35
2026_MES_763363_1
8800/26-27/28/E8
Open Tender
Civil Works - Water Works
Item Rate
330 days
GE (ARMY) NO 2 JOHDPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (ARMY) NO 2 JODHPUR
₹98,000
Yes
23 Jul 2026
4 May 2026
27 May 2026
4 May 2026
25 May 2026
18 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material & Labour for seven stage and sterilization of inside the RCC overhead tank reservior of capacity 5,000 gallons upto height 25 mtr through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 5 | Each job | 1 | ₹5 |
| 2 | Material & Labour for seven stage and sterilization of inside the RCC overhead tank reservior of capacity 50,000 Gallons at 15 to 20m staging through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 6 | Each job | 1 | ₹6 |
| 3 | Material & Labour for seven stage and sterilization of inside the RCC overhead tank reservior of capacity1,00,000 Gallons at 15 to 20m staging through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 10 | Each job | 1 | ₹10 |
| 4 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 1,50,000 Gallons at 15 to 20m staging through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 3 | Each job | 1 | ₹3 |
| 5 | Material & Labour for seven stage and sterilization of inside the RCC overhead tank reservior of capacity 2,00,000 Gallons at 12m to 18m staging through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 2 | Each job | 1 | ₹2 |
| 6 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 15000 ltr through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 7 | Each job | 1 | ₹7 |
| 7 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 10000 gallons through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 10 | Each job | 1 | ₹10 |
| 8 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 60000 gallons through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 2 | Each job | 1 | ₹2 |
| 9 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 1,00,000 gallons through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 2 | Each job | 1 | ₹2 |
| 10 | Material & Labour for seven stage and sterilization of inside the RCC/Steel underground/semi underground/over head/sedimentation/ckear water sumps UG sump reservior of capacity 1,50,000 gallons through bactriiological treatment by using suitable chemicals approved by Govt auth lab and ULTRA VIOLET RAY, through specialized agency. Seven stage are as under plants :- (a) First stage is to drain out the water by using exit valve or high capacity dewatering system (b) Second stage is cleaning all the algue formation inside the tank by using laboratory tested branded chemical of the company and scrubbing the walls of the tank (c) Third stage is fresh water cleaning by high speed jet pump (d) Fourth stage and first bacteria screening is disinfection by using branded halogen compound (e) Fifth stage is cleaning the floor of water tank by industrial vacuume cleaner (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kill all suspended bacteria (g) Seven stage of cleaning and third bacteria screening us to sterilize the floor of the tank. Notes :- (i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nv-10, terbac-g65/inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. All the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of overhead tank should be plugged before cleaning the overhead tank to avoid entering scales and the quoted rate is deemed to include for the provision. (iii) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tank sterilization. (iv) Contractor will be responsible for rectification of complaints occureed during cleaning the tank i.e. No water in tank/over flow due to broken of float valve/blockage to be included rate. (v) The above work will be either carried out in above seven stage or as directed and specified by Enge-in-charge. | 4 | Each job | 1 | ₹4 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
TENDER.pdf
Tender Documents • 1.02 MB
BOQ_855063.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .