Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹49.5 L+₹1.9 L (3.99%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹50.1 L+₹2.4 L (5.13%)Rejected-AOC HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹51.4 L+₹3.7 L (7.84%)Rejected-AOC 33 NATIONAL CHAMBERS NEAR CITY GOLD CINEMA ASHRAM ROAD AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹53.4 L+₹5.7 L (12.0%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
6 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVN OF SCREEN WALL NEAR EPs SINGLE LIVING AND CERTAIN REPAIR/REPLACEMENT WORK IN BLDG P_66 at CGDHQ_15, OKHA UNDER GE I CG PORBANDAR
2021_MES_485435_2
8654
Open Tender
Civil Works
Item Rate
180 days
Okha
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE I CG Porbandar
₹85,000
Yes
31 Dec 2021
25 Nov 2021
7 Dec 2021
25 Nov 2021
6 Dec 2021
30 Nov 2021
25 Nov 2021 - 29 Nov 2021
60 days
Amount
SCHEDULE 'A'
Excavation in trenches n.exc 1.5m wide n.exc 1.5m deep and getting out in hard and dense soil complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings exc 15 cm thickness above ground level as in sunken floors etc
Demolition of RCC of any description and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition)
M & L cutting of RCC beams/lintel of sec area not exc 0.13 sqm carefully with electric or gas cutter including providing sufficent Nos. of steel props at each junction of balance portion of beams /lintels and making good the cut portion with cement concrete/mortar as directed
Demolition of stone /boulders masonary work built in CM including all quoins, arches, pillars etc & removing from site.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing tiles and rubbish off the premises
Taking down cement plaster includiing raking out joints hacking for key and scrubbing down with water complete, all as specified and directed by Engiiner-in-Charge
Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames).
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m eachwith shutters (without taking off shutters from the frame)
Taking down steel tubing and connections 15 mm bore including cleaning for refixing or removal from site
Taking down steel tubing and connections 20 mm bore including cleaning for refixing or removal form site
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of capacity exc 250 ltr but not exc 500 ltr. (Cleaning repairing, etc. measured separately)
M&L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed
M&L RCC M-30 (Design Mix) (using 20mm garded stone agg) as in foundation, including rafts, footings, foundation beams, plinth beams; bases for columns, etc.,basement slabs, under reamed piles and mass concrete, all as specified.
M&L RCC M-30 (Design Mix) (using 20mm graded stone agg) as in column, pillars, piers, posts and struts etc. complete all as specified
M&L RCC M-30 (Design Mix) (using 20mm garded stone agg) as in beams,cantilevers, bands, coping,bressummers, lintels and the like all as specified.
M&L RCC M-30 (Design Mix) (using 20 mm graded stone agg) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified.
M&L RCC M-30 (Design Mix) (using 20mm garded stone agg) as in chajjas and the like all as specified.
M&L RCC M-30 (Design Mix) (using 20mm garded stone agg) as in stair case and steps, string pieces, RCC water tanks and like all as specified.
M & L Mild steel TMT CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L Mild steel TMT CRS bars 5mm dia and over upto 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished surfaces of concrete complete all as specified.
Use and waste of formwork to the sides of columns for rough finished surfaces of concrete.
Use and waste of formwork to sides and soffits of beams, lintels, including supports, overhangs, etc, also slpays between floors and beams, etc. and the like for rough finished surfaces of concrete.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete.
Use and waste of formwork to edges of concrete flats,breaks in floors, window cills, concrete railings,openings in concrete walls,floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in walls,horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide rough finished surfaces of concrete complete all as specified.
Use and waste of formwork to staircases with sloping or stepped soffits including risers and stringers(excluding landing)
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm
Removing excavated mateial n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point.
M&L for precast cement concrete type C1 1:3:6 (20 mm graded aggregate) block masonry with solid blocks, exc.10 cm in width and setting in mortar 1: 6 complete.
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement all as specified
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement all as specified
M&L Rendering 5mm thick in CM 1:3 on concrete surfaces on ceiling finished even and smooth without usising extra cement all as specified
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
Spreading and levelling in layers n exc. 25 cm thick including well ramming including watering as required
M & L Broken stone or boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface
M & L 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base.
S & F 30 mm thick flush shutters,solid core construction,with blockboard core and ply wood face panels with 0.90 mm thick decorative laminate type 1 on both sides of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions
S&F Aluminium alloy wire cloth,0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples
S & F 75mm long, stainless steel Butt hinges
S & F 125mm long, stainless steel Butt hinges
S&F 150mm long stainless steel barrel tower bolts of (ISI Marked) complete all as specified and directed.
S&F 200mm long stainless steel barrel tower bolts of (ISI Marked) complete all as specified and directed.
S&F 300mm stainless steel, sliding door bolt with hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts.
S&F 250 mm long Stainless steel handles, (ISI Marked) complete all as specified and directed.
S&F150 mm long Stainless steel handles, (ISI Marked) complete all as specified and directed.
S&F 150 mm long floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring complete all as specified and directed
S&F Aluminium door closer hydraulically regulated, designation No 2, universal type, sutiable for door shutter of 701 to 850 mm in width and of weight between 36 to 60 kg.
S & F 30 mm thick factory made solid panel PVC door shutter conferming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C' channel of size 30x50mm forming stiles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of 'C' channel using PVC solvent adhesive complete as per manufacturers specifications & drawings ass as directed by Engineer-inCharge Make : RAJSHREE/SINTEX
S & F Factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with 19x 19mm MS square tubes, provided with EPDM rubber gasket throughout the frame fixed in opening complete as per manufacturer's specifications and as directed by Engineer-in-Charge Make: RAJSHRI/SINTEX)
M&L double charged vitrified ceramic tiles with light shade 10 mm thich Square or Rectangular polished area of each tilles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles including 15 mm thick scread bedding in cement mortar 1:4 , all as specified
M&L double charged vitrified ceramic tiles with light shade 10 mm thich Square or Rectangular polished area of each tilles vertical surfaces exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles including 10 mm thick backing coat in cement mortar 1:4 , all as specified
M& L Non-Skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bedding layer in CM 1 : 4.
M& L Non-Skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bedding layer in CM 1 : 4.
S&F coloured glazed ceramic tiles 350x250x7/450x350mmx7mm thick on vertical surfaces including 10mm thick backing coat in CM 1:4 Such as skirting dados and riser to step etc set jointed in neat cement slurry and pointed in white cement to match
S&F coloured glazed ceramic tiles 600x1200mmx10mm thick on vertical surfaces including 10mm thick backing coat in CM 1:4 Such as skirting dados and riser to step etc set jointed in neat cement slurry and pointed in white cement to match
M&L for 20mm granite (of any type) work (table rubbed and polished) in window-cills, cooking platforms in single piece, bullnosing/rounding to edges of stone slab and two No grip line for stair case treads, and like in cement mortar (1:4) including pointing in white cement (1 : 2) using marble dust with admixture of pigment to match with shade of granite over 20mm screed in cement (1 : 6).
S & F PVC (SWR) floor trap with grating including jointing with solvent 75 mm bore
S & F PVC (SWR) pipe single socketed 110 mm dia in any length, jointing with cement solvent solution, fixed to walls, floor or ceiling complete all as specified
S & F PVC (SWR) pipe single socketed 75 mm dia in any length, jointing with cement solvent solution, fixed to walls, floor or ceiling complete all as specified
S & F PVC (SWR) bend with door acess for 110 mm dia pipe complete all as specified
S & F PVC (SWR) bend with door acess for 75 mm dia pipe complete all as specified
S & F PVC (SWR) single Tee with door acess for 110 mm dia pipe complete all as specified
S & F PVC (SWR) single Tee with door acess for 75 mm dia pipe complete all as specified
S&F 110 MM dia PVC (SWR) vent cowl
S&F 20mm dia ball valves high pressure of PTMT epoxy coated aluminium rod & high density plastic ball complete all as specified & directed.
S & F 25mm bore Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
Supply and lay of 25 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supply and lay of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S & F Rimless Wall Hung WC with UF Soft Close seat cover, Hinges, Accessories set, size 400x580x370mm (Make : Jaquar Cat Part No VHS-WHT-81953UF or equivalant
S & F vitreous china squatting plate urinal.
S & F PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality
S&F Grating square 150mm size of PTMT (Min wt 100 gms)
S&F 15mm bore CP two way angle valve, fancy type screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed in position
S&F 15mm bore CP two way Bib Tap with wall flange, fancy type screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed in position Jaquar Cat Part No ARI-39041
S&F Brushed Stainless steel shower panel of size 1400x200mm with inbuilt Anti-finger print stainless steel body, ABS top shower with 50 nozzels, ABS body massage jets, Chrome plated, Chrome plated ABS hand Shower, Brass spout, Multi function water diverter, Brass faucet body with Hot & Cold mixer, 40cm stainless steel braided hose, operating pressure - minimum 2 bar and 1.5 m stainless steel double locked flexible hoses complete all as directed.(Jaquar Cat Part No JPL-SSF-ST8858B3 or equivalent)
Metro Pole flush valve Regular 32mm size (Concealed body) with exposed shut off provision (fixed discharge of 4.00 ltr per flushing) mm dia Jaquar Cat Part No FLV-1095NG
S&F Double Arm Wall Mounted reversible plain/magnifying (X3) Pivtol Mirror (Jaquar Cat Part No ACN-1193N)
S&F Pillar tap Single lever tall body with 150mm extetion body and 600mm long braided Hoses Jaquar Cat Part No ARI - 39005B
S&F Sink cock with regular swinging spout (wall mounted model) with wall flange. Jaquar Cat Part No ARI - 39347S
S&F Towel Rack 600 mm long with lower hangers (Jaquar Cat part No AQN - 7781 or Equavalent)
S&F Towel Ring Square with round flange (Jaquar Cat part No ACN - 1121N or Equavalent)
S&F Tumbler holder (Jaquar Cat part No ACN - 1141N or Equavalent)
S&F Toilet Roll Holder (Jaquar Cat part No ACN - 1151N or Equavalent)
S&F Soap Dispenser with glass Bottle (Jaquar Cat part No ACN - 1135N or Equavalent)
S&F Spout with button attchment for hand shower (Jaquar Cat Part No SPJ-463 or equivalent)
S&F Health Faucet with 8 mm dia, 1.20 mtr long flexible tube & wall hook (Jaquar Cat part No ALD - 573 or Equavalent)
S&F Counter top Wash hand Basin Jaquar Cat Part No : SLS-WHT-6905
S&F Framed Shower Enclosure ENNA Corner entry with door sliding to both sides made of 6mm thick chrome finished glass sheet standard (Jaquar Cat Part No JSE-CHR-ENNA1010X or equivalent)
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard bar 60 cm long
S&F 5.5 thick set of 3 glass corner shelf
M&L for providing and fixing 10 mm thick plaster of paris including for sunk or raised moulding ceiling (Gypsum anhydrous) to flat surface, GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre /intermediate channel 0.9mm thick having two equal flanges of 15mm and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2mm length) of 0.55mm thickness having kurled web of 50 mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre and applying two coats of oil bound distemper including taking down existing complete all as specified and as directed
Supply only 12 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work.
M&L for 0.9mm decortive laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer insutruction
S&F 5.5mm thick frosted ordinary sheet glass quality and glazing with putty in each pane not exc 0.5mm thick fixed
Material & Labour for complete removal of existing treatment of walls by washing down and smoothing old surface of walls/ ceiling, prerparation of surface by applying two coats of interior plastic emulsion over a coat of primer over a layer of smooth Putty finish two coats as per manufacture instruction with smooth roller finish ,complete all as specified and directed. (Note after painting ,cleaning of all floors,glass & furniture by own arrangement). . .
M&L Lime concrete terracing including trowelling smooth as specified in roof and directed
Supply, laying, Jointing and testing XLPE insulated, Extruded PVC outer sheath and inner sheath, galvanised steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade and laid in trenches/pipe / ducts or on pole complete all as specified and directed and of the following sizes :-
25 sq mm 4.0 core
10 sq mm 4.0 core
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground calbes of size 50 mm outer dia with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Gemini
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc Note: Cost of Making Good of existing disturbed surface deemed to be included in unit rate.
M&L for Point wiring complete with 1.5 sqmm single core PVCinsulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for:- Note: Cost of Making Good of existing disturbed surface deemed to be included in unit rate.
One light point or one fan point controlled by one switch with cables 1.5 sq mm size
One 3 pin socket outlet 6 amps on the independent, with cables 1.5 sq mm size
One 3 pin socket outlet 6 amps on the same board with other switches, with cables 1.5 sq. mm size
Two light point controlled by one switch on the same switch circuit
M&L for Point wiring complete with 2.5 sqmm single core PVCinsulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for:- Note: Cost of Making Good of existing disturbed surface deemed to be included in unit rate.
S & F modular type 6 A one-way switch, 1 module Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker)
S & F modular type 16 A one-way switch, 1 module Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker)
Supply & fix modular socket, 6 Amps, 2/3 pin combind 2 module complete all as specified and as directed. Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker)
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module complete all as specified and as directed. Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker)
Supply & fix modular MCB, 25/32 Amps, 1 module complete all as specified and as directed. Make :- Legrand/ Schneider / Hager
M & L for ceiling rose, surface bakelite, 65x17 mm three terminals complete all as specified and directed. Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker)
S & F modular type bell switch 6 A one-way switch, 1 module Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker)
S & F bell modular type of two module complete all as specified and as directed Make :- Legrand (Arteor)/ Schneider (Zencelo)/ Hager (Berker)
Supply and fix in repair surface mounted slim round downlighter fitting 10 Watt , with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire all as specified . Make : Wipro (IRIS)/ Philips/HPL (Jonex Plus)
Supply & fix in repair LED lights, Nominal watt 25 Watt, Nominal lumen efficiency 120 lumen/Watt, high pressure die cast aluminium housing, 140-270V, 50 Hz,LED street light luminaries to be mounted on wall of Buildings including 3 core 1.5 sqmm PVC insulated copper cable from control box to fitting and mounting bracket of suiatble size with clamp , screw and washer complete all as spd and as directed by Engr-in-Charge Make:Wipro(Skyline+LR06-311-XXX-57-XX) Philips)/ /Osram(Strada plus)
Supply and fix reccessed type downlighter LED fitting 18/20 Watt ,5700K, cool white, with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire all as specified . Make : Philips(DN296B LED20S-6500 PSU WH)/Wipro/ Osram
Supply and fix reccessed type downlighter LED fitting 12 Watt ,3000K, Warm white, with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire all as specified . Make : Philips(12W Sky Spot COB (WW))/Wipro/ Osram
Supply and fix strip type LED fitting 5 m length, with mounting accesseries ,6500K, Cool white, with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire all as specified . Make : Philips(LED Strip SKYCove 5M CDL with driver)/Wipro/ Osram
S & F in repair VTPN DB 04 Way made of CRCA sheet, for flush mounting type with 250 Amp busbar copper, fully insulated & shrouded neutral bar, earth bar, fixed on wall, Prefitted masking sheet, Reversible Door confirming to IP 54 all as specified and comprising of following:- (i) MCCB 100 amp FP 36 KA 01 no (incoming) (iii) MCB 6/32 amp SP 10 KA C Curve : 12 Nos MAKE: DB & MCCB/MCB : SCHNEIDER/ LEGRAND/ HAGER
M&L for earthing complete with galvanized steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth strip 4mm mm by means of bolts nuts check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 20 mm dia. light grade pipe and watering pipe shall be 20 mm bore medium grade PCC pit with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed.
M & L for submain wiring in existing surface/ Wall using IS:694- 1990 marked 1.1 kV grade single core HR-FR flexible cable having multi- drawn thin strands of electrolytic copper conductors and insulation for phase & neutral and earth continuity conductor connecting to earth dolly, drawn in medium grade non-metallic PVC conduit not less than 25 mm dia., colour-coded and making good of disturbed surfaces of wall/ceiling/floor complete all as specified and directed. [NOTE: 02 runs of phase & neutral conductors, 01 run of earth continuity conductor and 01 run of concealed conduit shall be measured as one length.]
2 X 2.5 SQ MM + 1 X 2.5 SQ MM
2 X 4 SQ MM + 1 X 4 SQ MM
Taking down existing sub main wiring complete, including fixture and fittings removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Supply and Fix Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m all as specified and directed.Make: Almonard/Havells/khaitan
Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting.
Supply and Fix Thermoplastic CB Box 01 row , 9 Module of size 202 x 238 x 111 -with Terminals and lugs for cable of any size with necessaries fittings confirming to IP 65 Protection with metric knock out for cable entry all as specified and as directed by Engineer-In-charge Make :- Hensel/ Neptune/ Rittal/ Hager
S&F MCB SPN 16/32 A 10 KA, 240 V in CB Box Box Make: Legrand/ Schneider/Hager
S&F MCB SP 06/32 A 10 KA, 240 V in CB Box Box Make: Legrand/ Schneider/Hager
Supply and fix in repair surface mounted decorative cylindrical downlighter fitting 10/12 Watt , with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire all as specified . Make : Wipro / Philips/
Supply and Fix Thermoplastic Junction Box of Landscape Light Fittings of size 155x210x92 -with Terminals and lugs for cable size 10/16 Sqmm x 4 Sqmm with necessaries fittings confirming to IP 66 Protection with metric knock out for cable entry all as specified and as directed by Engineer-In-charge Make :- Hensel/ Neptune/ Rittal/ Hager
Supply and fix LED Post top light fitting Pure polyester UV resistant powder coated die cast aluminium housing with PMMA clear diffuser for uniform illumination with IP 65 protection with Suitable connector shall be provided for LED connection between driver output and LED and Extruded silicon loop gasket shall beprovided in the lantern body to ensure weather proof seal between the UV Glasscover and the metal housing to exclude the entry of the dust, water, insects etc.including Stainless steel stand of suiatable size fixed on existing wall including make good of surface all as specifed and directed. Make: Wipro(LP07-501-XXX-57-CL)/Philips(BGP161 LED2500/NW PSU 220-240V 7043 IN) /equivalent in Osram
Supply and install surface mounted vertical storage type 25 Ltr capacity, suitable for pressure pump, High Density PUF Heat Insulation,including mounting accessories and installation complete all as specified and directed.
Supply & fix AC Three phase static energy meter of accuracy class 1.0 ,3 X 240 V ,50 Hz with Backlit LCD display of rating 10 - 60 A (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box
Supply and lay lead free uPVC pipe in trenches/walls/cellings or laying in floors including suitable amount of solvent for piping and all fittings including threaded and sovent base as per site requirement complete of sizes of nominal dia:- 25mm
S & F in repair uPVC Gate /ball valves as per requirement of the site of the following 25mm
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of following sizes 25 mm bore
Supply and installed booster pump set , electric drivern 1 phase, 240 V (+10 or -10), 01 HP cap SS Body, 140 LPM capacity suitable for 25 mmx 25 mm suction and delivery, installation, Pump Cover of suitable size of SS and fittings , etc. complete all as directed by Engr in charge. Make :- Kirloskar/ equivalent in Crompton
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity2.0 TR
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR
Nitesh Enterprise
Harsh Infrastructure
shree chamunda enterprise
K K Construction Co
SURAJ ENTERPRISE
M/S. P.M GODHANIYA
roxy enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .