Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹9.5 L+₹1.1 L (13.2%)Rejected-AOC JOGESHWARI W 758 ADARS NEW LINK ROAD 758 ADARS MUMBAI 400101 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹10.9 L+₹2.5 L (30.3%)Rejected-AOC 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹11.3 L+₹3.0 L (35.3%)Rejected-AOC 127 GYAN LOK DEFENCE COLONY ROORKEE DISTT HARIDWAR UK PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹12.5 L+₹4.1 L (48.9%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
17 Jan 2022, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ Commander Works Engineers Hills Mall Road Dehradun Cantt Dehradun 248003 Tele 01352757790
REPAIR REPLACEMENT MAINT OF INTERNAL FITTINGS REWIRING AND SUB MAIN AND BD BOX AT VARIOUS LOCATION ZONE 1 LANSDOWNE
2021_MES_493145_1
87101/LDN/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
Class E Cat b i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹36,000
10 Feb 2022
8 Dec 2021
19 Jan 2022
8 Dec 2021
17 Jan 2022
5 Jan 2022
8 Dec 2021 - 15 Dec 2021
Amount
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Taking down carefully by unscrewing ceiling roses, Light fittings, switch , sockets, regulators for reuse at site and carrying to the store to re-fix the serviceable materials complete all as specified & directed.(To be measured only when found serviceable in all respect for reuse. )
Dismantling and taking down u/s sub-main wiring of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down old damaged existing TPN DB/DB’s of any type and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc. complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit, "medium grade" (ISI marked) , not less than 20 mm dia duly concealed on wall/ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall deemed to be included in quoted rates. ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
All as per item no 5.01 but for One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
All as per item no-5.01 here-in-before but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified & directed.
All as per item No 5.01 here-in-before but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including surface rigid PVC conduit," medium grade" (ISI marked), not less than 20 mm dia on wall/ceiling or above false ceiling with fittings (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed.
One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
All as per item no-6 above but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per item no-6.00 above but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified and directed.
All as per item No 6 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified and directed.
All as per item No-06 above but in existing concealed conduit inside wall, ceiling etc (light, fan, call bell) complete all as specified and directed.
All as per Item No 6.01 above but in existing concealed conduit inside wall, ceiling etc (5 amps socket on same board) complete all as specified and directed.
All as per Item No 6.02 above but in existing concealed conduit inside wall, ceiling etc (5 Amps socket on Independent board) complete all as specified and directed.
All as per Item No 6.03 above but in existing concealed conduit inside wall, ceiling etc (Two way point wiring) complete all as specified and directed.
All as per Item No 6.04 above but in existing concealed conduit inside wall, ceiling etc (power point) complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including, PVC Casing Caping "medium grade" (ISI marked) , of 20 mm size fixed on wall/ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed.
All as per Item No 8 above but for (5 amps socket on same board) complete all as specified and directed.
All as per Item No 8 above but for (5 amps socket on Independent board) complete all as specified and directed.
All as per Item No 8 above but for (two way point) complete all as specified and directed.
All as per Item No 8 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified and directed.
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or Cona Cat Part No: 9251
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC complete all as specified and directed. Make: Legrand cat No: 673411/ Indoasian Cat No: 800002 or Cona Cat Part No: 9386
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 52 / Indoasian cat no: 800020 or Cona Cat Part No: 9301
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz complete all as specified and directed. Make:- Legrand cat No: 6734 55 / Indoasian cat no: 800022 or Cona Cat Part No: 9311
Supply and fixing switch modular single pole, two way 6 Amp, 1 module ISI marked, 230 volts, 50 hz all complete all as specified and directed. Make:- Legrand cat No: 6734 02 / Indoasian cat no: 800001 or Cona Cat Part No: 9256
Supply and fixing bell push modular single pole one way 6 Amps, 1 module , ISI marked complete all as specified & directed. Make:- Legrand cat No: 673022 / Indoasian cat no: 800007 or Cona cat part No-14011.
Supply and fixing bell ding dong AC 230/240 volts single pole, complete all as specified & directed.
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals ISI Marked complete all as specified & directed.
Supply and fixing Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings ISI Marked complete all as specified & directed.
S&F in repairs switch piano 230 volts, AC, flush type single pole, one way 5/6 Amps ISI marked complete all as specified and directed. Make:- Cat part no HSN8536/14111 OF Anchor or HSN 8536/7001 of Cona or Havells Reo Cat Part No-AHESXXW061
S&F in repair switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one way complete all as specified and directed.Make:-Cat part no HSN8536/33118 of Anchor or HSN 8536/7081 0f Cona or Havells Reo Cat Part No-AHESXXW201
S&F in repairs, socket out let 3/5 pin 5/6 Amps flush type complete all as specified and directed. Make:- Cat part no HSN8536/14302 of Anchor, HSN 8536/7021 of cona or Havells Reo Cat Part No-AHEKP01W063
Supply and fixing in repair socket outlet 5/6 pin 5/15 amp flush type multi suitable for 240 volts AC ISI marked complete all as specified and directed. Make:- Cat part no HSN8536/145045 of Anchor, HSN8536/7081 of cona or Havells Reo Cat Part No-AHEKUXW063
Supply and fixing in repair batton/angle holder insulated body with back plate, suitable for batten fittings complete all as specified & directed.
Supply and fixing in repair bell ding dong AC 230 volts single pole complete all as specified & directed.
Fixing only surface mounted LED luminiare, 20 watt 4 feet fitting with and including internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. Note:- The LED tube light fitting of 20 watt complete will be issued under Sch 'B' free for fixing.
Fixing only Straight Linear 10Watt, LED Luminaries 2 feet fitting, with and including internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. Note:- The LED tube light fitting of 10 watt complete will be issued under Sch 'B' free for fixing.
Fixing only 6 Watt recess mounted fitting round type with and including internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. Note:- The LED 6 Watt recess mounted round type fitting complete will be issued under Sch 'B' free for fixing.
Fixing only Decorative gate light fitting complete with 20 Watt LED Lamp with and including connecting up with twine core twisted flexible copper conductor cable of suitable size complete all as specified & directed. Note:- The Decorative gate light fitting complete with 20 Watt LED Lamp complete will be issued under Sch 'B' free for fixing.
Fixing only 36 Watt, recess mounted LED Panel 2 feet X 2 feet with and including internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. Note:- The LED 36 watt recess mounted type complete will be issued under Sch 'B' free for fixing.
Fixing only 18 Watt recess mounted LED Panel 1 feet X 1 feet with and including internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. Note:- The LED 18 watt recess mounted type complete will be issued under Sch 'B' free for fixing.
Fixing only LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, including fixing on existing bracket including making necessary electric connection with 1.5 sqmm , 3 core, PVC insulated copper conductor cable 1100 Volt grade complete all as specified and as directed. Note:- The LED Bldg security light 20 watt complete will be issued under Sch 'B' free for fixing.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 415V AC 4 way with 200 Amps rated bus bar complete all as specified and directed.
Supply and fixing sheet metal enclsoure double door type for MCCB DB TPN 4 way as incommer with MCCB 4 pole, adjustable thermal & fixed magnetic type 40-63 Amp, 16 KA, 4 pole of Make:- Legrand, ABB, Schnedier complete all as specifie and directed. Note:- Set the MCCB as per builidng load and distribute the load before charging the circuit.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing MCB SPN 6- 32 Amp 240 V AC 10 KA B curve rupturing capacity complete all as specified & directed.
Supply & fixing MCB, TPN, AC, 415 volts of 40-63 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply and fixing MCB SP 5 to 10 Amp 'B' series 10 KA 240 V AC 50 Hz repturing capacity complete all as specified & directed.
Supply and fixing MCB SP 2-5 Amp 'B' series 10 KA 240 V AC 50 Hz repturing capacity complete all as specified & directed.
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with 01 No, RCCB 15 Amp, DP, 240 Volts, AC Complete all as specified & directed.
Supply and fixing single pole and neutral enclosure modular type with a two pole and earth plug socket complete with one, single pole MCB 20 Amps 10 KA repturing capacity 240 Volts AC complete all as specified & directed.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in existing conduit, surface/ concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified and as directed .Note: Two runs of phase, netural wire and one run of earth wire will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in existing conduit surface/ concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly complete all as specified and as directed .Note: Two runs of phase, netural wire and one run of earth wire will be measured as one RM or one length.
M&L laying or passing through pipe LT UG XLPE PVC insulated,steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 2 core including taking out old unserviceable cable complete all as specified and directed.
Excavation in trenches in any type of soil and n.exc 1.5 m wide and n. Exc 1.5 in depth for laying GI tubing for connect to near by water pipe line or for poles, laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and directed.
Returing, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, in any type of soil complete all as specified and directed.
Removing excavated material ( surplus soil) to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specifed and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
Supply and laying unreinforced precast concrete cable cover Class LV, Type-I flat size 250 mm x 150 mm x 40 mm ISI Marked complete all as specified and directed.
Supplying, laying & jointing GI tubing light grade ISI Marked of size 50mm bore, in trunches/pole post/under culvert/under road etc for cable porection, complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Fixing only serviceble light fitting retrived from Item No-02 above complete all as specified and directed.
Fixing only serviceable switches retrived from Item No-02 above complete all as specified and directed.
Fixing only serviceable sockets retrived from Item No-02 above complete all as specified and directed.
Supply only 4mm dia GI wire complete all as specified and directed.
DEEP ENTERPRISES
M/S OM Enterprises
Bhardwaj Construction Co
R P G ELECTRONIC REGD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .