Executive Engineer ( Electrical ) BSNL ED Shimla
TOP FLOOR BLOCK NO. 35 KASUMPATI SHIMLA 171009
Supplying Installation, Testing and Commissioning of Electrical Installations, Fans, Fittings, Earthing, Lightening conductor etc. for External Project work at 30 Bedded Civil Hospital at Dalash, Teh. Anni, Distt. Kullu HP
2026_BSNL_299156_1
47/EE/E/BSNL/ED/ETEN/SML/26-27
Open Tender
Electrical Works
Item Rate
30 days
DALASH TEH ANI DISTT KULLU HP
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Account Officer (EF) BSNL, O/o CGMT, HP Circle Shi
₹30,340
26 Nov 2026
26 Nov 2026
8 Dec 2026
26 Nov 2026
7 Dec 2026
26 Nov 2026
26 Nov 2026 - 2 Dec 2026
150 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SUB HEAD-I (Fan & Fittings & Misc.) | |||||
| 1.01 | Supplying, installation, Testing & Commissioning of Panel light of following sizes and body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50 Hz, Operating temperature range -50°C to 40°C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD<10%, P. F. ≥0.95, IP20, CRI≥80, UGR (Unified Glare Rating) ≤19, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Preferred make Philips/ Wipro/ Havells/ Crompton/ Bajaj/ Osram/ Surya or Similar Superior) | - | - | - | - |
| 1.011 | 600mm x 600mm (Nominal dimension) Powder Coated CRCA Sheet Body (Thickness ≥0.50 mm) 36 watt surface/Recess mounting type (As per site requirement, quantity of surface & recess to be taken form EE before supply) | 67 | Nos. | 100 | ₹6,700 |
| 1.012 | 300mm x 300mm Powder Coated CRCA Sheet Body (Thickness ≥0.50 mm) 24 watt surface mounting type | 20 | Nos. | 100 | ₹2,000 |
| 1.013 | 300mm x 300mm Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm) 24 watt recess mounting type | - | Nos. | 10 | - |
| 1.015 | 1200mm x 300mm Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm) 36 watt surface mounting type | 1 | No. | 10 | ₹10 |
| 1.016 | 1200mm x 300mm Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm) 36 watt recess mounting type | 1 | No. | 10 | ₹10 |
| 1.017 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency 50Hz, Operating temp range -5°C to 40°C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≤120<135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Preferred make Philips/ Wipro/ Havells/ Crompton/ Bajaj/ Osram/ Surya or Similar Superior Make) | - | - | - | - |
| 1.02 | Powder coated CRCA Sheet Body (Thickness ≥0.50 mm) 40 Watt | 48 | Nos. | 10 | ₹480 |
| 1.021 | Powder coated CRCA Sheet Body (Thickness ≥0.50 mm) 18-22 Watt | 22 | Each | 10 | ₹220 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
TENDERDOCEIFANDALASHREVISED26112026.pdf
Tender Documents • 1.26 MB
BOQ_348428.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .