Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.2 L+₹2.4 L (9.72%)Rejected-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹28.3 L+₹3.5 L (14.1%)Rejected-AOC | L3 | Rejected-AOC Not Lowest Bidder | |
| 4 | L4₹30.6 L+₹5.8 L (23.6%)Rejected-AOC | L4 | Rejected-AOC Not Lowest Bidder | |
| 5 | L5₹32.2 L+₹7.5 L (30.2%)Rejected-AOC | L5 | Rejected-AOC Not Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
8 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) No 02 Jodhpur
GE (AF) No 02 Jodhpur
Day to day maint of internal elect, repair maint of ceiling, wall mounted fan, geysers under GE (AF) 02 Jodhpur
2024_MES_645940_1
8440/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) No 02 Jodhpur
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) No 02 Jodhpur
₹1 L
Yes
18 May 2024
11 Mar 2024
11 Apr 2024
11 Mar 2024
8 Apr 2024
25 Mar 2024
18 Mar 2024 - 23 Mar 2024
Amount
Labour only for attending complaints of unserviceable ceiling fans, exhaust fans and its allied electrical repairs at domestic area of AF station Jodhpur (Outer and Inner domestic area) carrying out necessary repairs at site by replacing unserviceable spares or taking down carefully unserviceable ceiling fan/Exhaust fan by disconnecting electrical connections, un-screwing from position, dismantling blades and removing fan and blade to workshop for carry out necessary repairs & re-fixing the same all as directed and specified. Note : (i) All connecting wiring shall be PVC insulated single core stranded copper conductor of size 0.5 sqmm with proper colour coding drawn through heat insulation sleeves of suitable size. (ii) Necessary spare parts required to repair at site shall be measured and paid separately under relevant items. Necessary deposit receipt shall be provided to users for taken down fan/exhaust fan as per prescribed printed format to be arranged by contractor. Contractor shall arrange necessary transportation to bring the taken down ceiling/exhaust fans for repair/replacement.
M&L for re-winding of burnt ceiling fans by opening covers of ceiling fan, remove the burnt winding, cleaning the slots and rewinding the fan with supper enamelled copper wire of same wire gauge, varnishing after winding, drying, replacing unserviceable fan bearings No 6201/6202 for 1200/1400mm sweep, greasing, soldering the copper terminal of winding with single core copper multi-slandered wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 2.5 mfd and making connection with fan capacitor and connector block, transporting back after repair, assembling the blades and hanging the fan in its own position to existing fan clamp and down rod with necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as directed at site. Note : 1. Quoted rates shall deems to be inclusive cost of varnish, insulation papers, sleeves, cotton tape for binning coils including minor spare like nuts, washer, screws, tension spring required for assembling and fixing fans in position. 2. Fan bearing & fan capacitor if required shall be measured and paid separately under relevant item. 3. Fan re-winding & replaced bearings will be inspected by Engr-in-Charge before assembling the fan motors.
M&L for re-winding of burnt exhaust fan/wall fans motor of following size sweep fans by opening covers by unscrewing nuts/screws, remove the armature shaft and checking for its defects, checking defects in stator core & windings, cutting burnt wading of stator, cleaning the slots and rewinding the fan with supper enamelled copper wire of same wire gauge, varnishing after winding, drying, replacing unserviceable fan bush/bearings, greasing, replace of armature coil with complete shaft if required, soldering the copper terminal of winding with single core copper multi-slandered wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 2.5/4.0mfd and making connection with fan capacitor and connector block, re-assembling fan exhaust fan with frame and blade, transporting back after repair, fixing the exhaust fan in its own position to existing fan clamp or with new screws and guttis or necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as directed at site. All connecting wiring shall be PVC insulated single core stranded copper conductor of size 0.5 sqmm with proper colour coding drawn through heat insulation sleeves of suitable size. Note : 1. Quoted rates shall deems to be inclusive cost of varnish, insulation papers, sleeves, cotton tape for binding coils including minor spare like nuts, washer, screws, tension spring required for assembling fans. 2. Exhaust fan bearing/bush, blade, frame & capacitor if required shall be measured and paid separately under relevant item. 3. Armature coil with complete shaft if required shall be measured and paid separately under relevant item. 4. Fan re-winding & replaced armature will be inspected by Engr-in-Charge before assembling the fan motors:-
Exhaust fan motor of 300mm sweep exhaust fans
Exhaust fan motor of 450mm sweep exhaust fans
Exhaust fan motor of 400/450mm sweep wall fan/pedestal fans
Supply only in repairs fan bearing of size 6101 suitable for ceiling fan 1200/1400mm sweep.
Supply only in repairs fan bearing of size 6202 suitable for ceiling fan 1200/1400mm sweep.
Supply only in repairs fan capacitor 2.5 Mfd suitable for ceiling fan 1200/1400mm sweep.
Supply only in repairs fan capacitor 4.0 Mfd suitable for exhaust fan 300/450/600mm sweep.
Supply only in repairs fan down rod 18 inch long for hanging ceiling fan 1200/1400mm sweep.
Supply only in repairs fan down rod 21 inch long for hanging ceiling fan 1200/1400mm sweep.
Supply only in repairs fan down rod 24 inch long for hanging ceiling fan 1200/1400mm sweep.
S&F Anti suicide fan down rod 15 inch long for hanging ceilling fan 1200/1400mm sweep
S&F Anti suicide fan down rod 18 inch long for hanging ceilling fan 1200/1400mm sweep
M&L for cutting holes 300mm diameter for preaparing opening through brick/stone masonary wall for fixing exhaust fan 300mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall all as directed by Engr-in-charge at site
S&F Exhaust fan 450 mm sweep, heavy duty, metal body, four blade, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified.
S&F Exhaust fan 300 mm sweep, heavy duty, metal body, four blade, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified.
S&F Exhaust fan 300 mm sweep, made of sturdy engineering plastic, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified.
S&F Exhaust fan 250 mm sweep, made of sturdy engineering plastic, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified.
M&L for taking out old unserviceable lovers shutters of exhaust fans 300/350 mm diafrom external face of walls from double/tripple storey buildings and providing aluminium wire mesh (3 to 4 mm mesh) with Aluminium frame (Guage thickness not less than 1.2mm) including necessary fixing accessories (like clamps, screws, wahsers, gutties etc) to prevent entry of birds/insects through opening of exhaust fans on walls. Approximate size of frame tobe provided at site is 400mm x 400mm for 300mm dia openings holes and 600mm x 600mm for 450mm dia openings holes. Note : Necessary T&P such as ladders, safety belts, drilling equiptments for fixing Wiremesh at heights of double/tripple storey building shall be arranged by the contractor and cost for the same deems tobe included in quoted rates.
M&L for taking out old unserviceable lovers shutters of exhaust fans 450 mm dia from external face of walls from double/tripple storey buildings and providing aluminium wire mesh (3 to 4 mm mesh) with Aluminium frame (Guage thickness not less than 1.2mm) including necessary fixing accessories (like clamps, screws, wahsers, gutties etc) to prevent entry of birds/insects through opening of exhaust fans on walls. Approximate size of frame tobe provided at site is 400mm x 400mm for 300mm dia openings holes and 600mm x 600mm for 450mm dia openings holes. Note : Necessary T&P such as ladders, safety belts, drilling equiptments for fixing Wiremesh at heights of double/tripple storey building shall be arranged by the contractor and cost for the same deems tobe included in quoted rates.
M&L for Painting of ceiling/exhaust fans complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and writing MES No with black paint as directed by Engr-in-Charge. Note : Painting of ceiling fans tobe carried when the body is opened for repair works for re-winding to avoid bearing Jam due to paint and motor shall be assebled after drying of paint.
S&F Stepped type electronic fan regulator, switch size, flush type 230V AC.
S&F electronic fan regulator modular stepped type 120 watt, two module.
S&F Stepped type Modular /Non Modular electronic fan regulator, switch size, flush type 230V AC,for BLDC fans and supporting to all type ceiling fans. Note-Regulator should work on BLDC Fans and as recommended by Engineer-in charge.
Supply and fix in repairs Heating element copper body chromium plated of rating 1.5 KW, 230 volts ISI marked, 10 inch long, and dia of tube not less than 8.5mm, triangular or cup type base including rubber washer suitable for old pattern geysers complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make.
Supply and fix in repairs Heating element copper body chromium plated of rating 2.0 KW, 230 volts ISI marked, 8/10 inch long, and dia of tube not less than 8.5mm, triangular or cup type base including rubber washer suitable for old pattern geysers complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make.
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc.
M&L for point wiring with 2.5 Sq. mm, multi-stranded copper conductor, single core,FRLSH, PVC insulated and unsheathed cable for phase and neutral, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in and including PVC Casing and Caping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed .
M&L for point wiring with 4 Sq. mm, multi-stranded copper conductor, single core,FRLSH, PVC insulated and unsheathed cable for phase and neutral, including 4 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in and including PVC Casing and Caping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed .
S&F(in repairs) Switch Socket combination outlet 6 pin, 6/16 Amp, flush type
Supply and fix in repairs 3 Pin Plug Top 16 Amps, 240 volt insulated bakelite body(Ivory/White)
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.
Supply and fix in repairs metal clad, 2 Pin+Earth Plug SOCKET only 16 Amps, 240 volt.
Supply and fix in repairs metal clad, 2 Pin+Earth Plug Top 16 Amps, 240 volt.
Supply and fix in repairs Thermostat (8/10 inch long) auto cut with thermal setting upto 80 degree centigrade, 230 V, for the geysers 25/50 Ltrs capacity as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge .
Supply and fix in repairs Thermostat (8/10 inch long) auto cut with trip reset push button type, 230 V, for the geysers 25/50 Ltrs capacity as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge .
Supply and fix in repairs capillary type Thermostat suitable for new gernation energy efficient geyser for tempterature control auto cut function, 230 V, size and capacity as per site requirement complete all as specified and as directed by Engr-in-Charge .
M&L for replacement of HOT & COLD PVC water connection pipes stainless steel braided flexible pipe 450mm long as per Cat No GSSGGX0030 of Make Havells or equivalent in approved makes.
Supply and fix in repairs Heat resistant heavy duty pressure grade 6 kg/sq cm, stainless steel wiremesh braided HOT & COLD flexible PVC connecting pipe with brass adapters 600 mm long suitable for 15 mm dia pipe and fixed in position as in repairs complete all as approved by Engineer-in-charge. Make-Havells/Crompton or as per approved makes.
M&L for replacement of HOT & COLD PVC water connection pipes stainless steel braided flexible pipe 750mm long of Make Havells or equivalent in approved makes.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in and including PVC Casing and Caping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed for following : -
One light point/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & electronic type fan regulator.
One light point controlled by two Nos 5 Amps switch two way
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
One 3 pin 5 Amp switch & socket outlet on Independant board.
One bell point controlled by one switch 5 Amps bell push.
S&F Switch piano, flush type, single pole, one way, 6 Amp.
S&F Switch piano, flush type, single pole, one way, 16 Amp.
S&F Socket outlet 2/3 pin, 2-in-1, 5/6 Amp, flush type.
S&F Switch Socket combination outlet 6 pin, 6/16 Amp, flush type
S&F(in repairs) Ceiling rose surface bakelite 65x50mm three terminal.
S&F(in repairs) Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or squre box using necessay screw & gutti complete all as specified.
S&F electronic Bell Bul-Bul music, 230 volt, single phase.
S&F bell push, type, 6 Amps, 2 Module
S&F switch modular single pole one way 6 Amps 230 volt 1 module.
S&F switch modular single pole one way 16 Amps 230 volt 1 module.
S&F Socket modular 6 Amp 2/3 pin combined two module.
S&F Socket modular 6&16 Amp 2/3 pin combined two module.
S&F electronic fan regulator modular stepped type 120 watt, two module.
S&F modular white or Ivory cover plate with frame 1 module
S&F modular white or Ivory cover plate with frame 2 module
S&F modular white or Ivory cover plate with frame 3 module
S&F modular white or Ivory cover plate with frame 4 module
S&F modular white or Ivory cover plate with frame 6 module
S&F modular white or Ivory cover plate with frame 8 module
M&L for channel or grooves cutting upto a depth of 2.5 cm and width not exc 15cm into brick/concrete/stone masonary walls, with or without re-inforcement and trimming surface as required, including concealing PVC conduit 20/25mm dia with required accessories (like junction boxes/bends etc) and plastering in 1:4CM, applying two coats of approved quality white putty for making good with smooth finish to match with the existing specification of wall surface all specified and directed by engr-in-charge.
S&F Wall Mounted decorative luminaire fitting suitable for LED lamp B-22 Base 9 watt light fitting including inbuild LED light driver connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking out existing unserviceable switch board plates any type, dismantling switches cafully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6/8 inch x 10 inch MS box and brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper mulitstranded cable all as directed at site by Engineer-in-charge. Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items.
All as per item ser No 63.00 here-in-before but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 6/8 inch 4 inch MS box.
All as per item ser No 63.00 here-in-before but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 4 inch MS box.
Supply and replace sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
Supply and replace sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.
M&L and in replacement for MCB SPN 32 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L and in replacement for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L and in replacement for SPN/DP RCBO 40 Amps 240 volts, 30 mA capacity and 10 kA rupturing caoacity providing in DB complete including connection & testing all as specified. Make- Havells cat part no-DHCEACSN2030040
Taking down carefully light fitting any type from surface/recessed/wall mounting type stacking at site for re-use or shifting unserviceable lights to store for taking credit all as directed and specified.
Supply and fixing in repair of LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL25W or equivalent model approved makes.
S&F LED light fitting 1 x 10W bulkhead luminaires including inbuild LED light driver perfect interior and exterier application connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as per crompton cat ref no. LCTLR-36-FO-CDL or equivalent in approved makes.
M&L for Sub main wiring with approved colour coding as per IS, single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for following sizes of wires :-. (Note : GI saddle shall be used to fix PVC conduit and distance between two saddle shall not be exceed 1.2 mtr)
Two runs of 2.5 Sq.mm main cable alongwith one run of single core 2.5 Sq.mm for continuous earth wire
Two runs of 4.0 Sq.mm main cable alongwith one run of single core 4.0 Sq.mm for continuous earth wire
Two runs of 6.0 Sq.mm main cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire
Two runs of 10.0 Sq.mm main cable alongwith one run of single core 10.0 Sq.mm for continuous earth wire
Note (a) The contractor will deploy sufficient resources for completion of day to day comaplaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit suitable penalties as mentioned in relavant clause of Contract. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consulatation with Engr-in-Charge or JE detailed by him. (c) The contractor will make suitable arrangment for emergent complaints and will notify JE/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rated deems to be inclusive of transportation, T&P and other expenses required for the resource deployment at the complaint site around scattered at AF Station Jodhpur. (f) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed periodically by Engr-in-charge or JE detailed by him to streamline complaints disposal system.
Nvimal Engineers and Contractor
M/S SUMAN ENTERPRISES
M/S VENUS BUILDER
DURGA ENGINEERING COMPANY
VARDHMAN SALES CORPORATION
Shri Maruti Trading Co.
new india engineers
VIKAS CONSTRUCTION CO.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .