Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹10.0 L+₹1.6 L (18.4%)Rejected-AOC | L2 | Rejected-AOC BEING L3 | |
| 3 | L3₹9.9 L+₹1.5 L (17.4%)Rejected-AOC JHABRERA ROAD NEAR POWER STATION MANGLOR DISTT HARIDWAR UTTRAKHAND | MANGLOR | HARIDWAR | UTTARAKHAND | L3 | Rejected-AOC BEING L2 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
14 Sept 2020, 6:00 pmClosed
GE 871 EWS
GE 871 EWS C/O 56 APO
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION AND WATER SUPPLY SYSTEM AT HARSIL , SUKHI AND TEKLA UNDER GE 871 EWS
2020_MES_370080_1
8546/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
HARSIL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 871 EWS
₹18,000
Yes
22 Sept 2020
18 Aug 2020
16 Sept 2020
19 Aug 2020
14 Sept 2020
1 Sept 2020
19 Aug 2020 - 7 Sept 2020
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc to match with the existing surfaces all as specified and directed.
M&L for point wiring in PVC casing & caping of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for One light/bell point controlled by one ,one way switch . Make of Casing and Caping is Kalinga/ Harish/Polypac/Plaza/Gaurav and Make of PVC Copper wire : Plaza/Polycab/Havells/RR Kabeel
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 2 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 2.5 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way all as specified & directed. Make : Havells/Anchor/legrand/HPL
S&F in replacement switch piano flush type 5/6 Amps single pole one way all as specified & directed. Make : Havells/Anchor/legrand/HPL
S&F switch piano flush type 15/16 Amps single pole one way all as specified & directed. Make : Havells/Anchor/legrand/HPL
S&F in replacement of switch piano flush type 15/16 Amps single pole one way all as specified & directed. Make : Havells/Anchor/legrand/HPL
M&L socket out let 5 pin 5/6 Amps all as specified and directed. Make : Havells/Anchor/legrand/HPL
M&L in replacement for socket out let 5 pin 5/6 Amps all as specified and directed. Make : Havells/Anchor/legrand/HPL
S&F socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed. Make : Havells/Anchor/legrand/HPL
S&F in replacement of socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed. Make : Havells/Anchor/legrand/HPL
S&F bell push, flush type 5 Amps white or ivory, ISI marked all as specified and directed. Make : Havells/Anchor/legrand/HPL
S&F of call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed. Make : Havells/Anchor/legrand/HPL
S&F plug top 15 Amp white or ivory, ISI marked all as specified and directed. Make : Havells/Anchor/legrand/HPL
S&F plug top 5 Amp white or ivory, ISI marked. Make : Havells/Anchor/legrand/HPL
S&F ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified and directed. Make :Havells/SSK/Cona
S&F in replacement of ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified & directed. Make :Havells/SSK/Cona
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings Make : Havells/Anchor/legrand/HPL
S&F in replacement of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings Make : Havells/Anchor/legrand/HPL
S&F 3 watt LED bulb. cool day light, 230/240V AC supply all as specified and as directed. Make : Havells/philips/Bajaj
S&F in replacement of 3 watt LED bulb. cool day light, 230/240V AC supply all as specified and directed. Make : Havells/philips/Bajaj
S&F 5 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make : Havells/philips/Bajaj
S&F in replacement of 5 watt LED bulb. cool day light, 230/240V AC supply all as specified and directed. Make : Havells/philips/Bajaj
S&F 7 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make : Havells/philips/Bajaj
S&F in replacement of 7 watt LED bulb cool day light, 230/240V AC supply all as specified and directed. Make : Havells/philips/Bajaj
S&F 10 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make : Havells/philips/Bajaj
S&F in replacement of 10 watt LED bulb cool day light, 230/240V, AC supply all as specified and directed. Make : Havells/philips/Bajaj
S&F in replacement of LED light fitting, 1 x 10 watt bulk head luminaris, Landscape lighting fixture with all accessories and including connecting up with twin core twisted flexible copprer conductor from celing rose to fittting connector all as specified and directed. Make Havells /Philips/CG/Bajaj
S&F in replacement of LED light fitting two feet 1x10 watt, slim design, 230volts, indoor recess mounting down light circular type with reflector and detachable ballast tray, with lamp holder, connector block and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Philips/Bajaj/Havells
S&F LED tube light fitting bright 18 watt slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Havells Cat Pt No LHEXBLP7JN1W018 or equivalent Philips/Baja
S&F in replacement of LED tube light fitting bright 18 watt. slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Havells Cat Pt No LHEXBLP7JN1W018 or equivalent Philips/Bajaj
S&F of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed Make:- Havells Cat Part No: ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent CG/ Bajaj/HPL
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed Make:- Havells Cat Part No: ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent CG/ Bajaj/HPL
M&L in replacement of earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long, etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
Supply and fix in replacement of DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/ Havells /HPL
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/ Havells /HPL
Supply and fix in replacement of DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/ Havells /HPL
Supply and fix in replacement of DB, TPN 4 way vertical type with single/three phase outgoing with provision for MCCB as incomer 415 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/ Havells /HPL
Supply and fix in replcement MCB 6-32 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed Make:-Legrand/Schneider/ Havells /HPL
Supply and fix in replcement MCB 32-40 amps, 10 KA, DP 240 volt, 'C' series all as specified and directed Make:-Legrand/Schneider/ Havells /HPL
All as per item No 42 hereinbefore but MCB DP 63 amps. Make:-Legrand/Schneider/ Havells /HPL
All as per item No 42 hereinbefore but MCB DP 100 amps. . Make:-Legrand/Schneider/ Havells /HPL
All as per item No 42 hereinbefore but MCB TP 63 amps. Make:-Legrand/Schneider/ Havells /HPL
All as per item No 42 hereinbefore but MCB TPN 63 amps. .Make:-Legrand/Schneider/ Havells /HPL
Supply & fix in replacement of on load change over switch 4 pole, 100 Amps suitable for 3 phase, 415 Volts in sheet metal enclosures fixed in sheet metal box made out of 2 mm thick CRCA sheet of suitable size with angle iron frame of size 50x50x6 mm, 1.5 metre high including grouting in PCC 1 : 2 : 4 all as specified & directed. Make :Havelles/ Legrand/L&T/HPL
Supply & fix in replacement of on load change over switch 4 pole, 63 Amps suitable for 3 phase, 415 volts in sheet metal enclosures fixed in sheet metal box made out of 2 mm thick CRCA sheet of suitable size with angle iron frame of size 50x50x6 mm, 1.5 metre high including grouting in PCC 1 : 2 : 4 all as specified & directed. Make :Havelles/ Legrand/L&T/HPL
Supply & fix in replacement of on load change over switch 2 pole, 32 Amps suitable for single phase, 230 volts in sheet metal enclosures fixed in sheet metal box made out of 2 mm thick CRCA sheet of suitable size with angle iron frame of size 50x50x6 mm, 1.5 metre high including grouting in PCC 1 : 2 : 4 all as specified & directed. Make :Havelles/ Legrand/L&T/HPL
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, descaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the Geyser in position, connection and testing all as specified & directed
S&F in replacement PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 450 mm long for hot/cold water (ISI marked) all as specified & directed.
S&F in replacement of PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 600 mm long for hot/cold water (ISI marked) all as specified & directed.
Supply and fix in replacement of stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection all as specified and directed. Make : Leader/Kirloskar/L&T/Prayag/ TATA
S&F in replacement of inner tank 9 holes suitable for Geyser 25 liters capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of inner tank 6 holes suitable for Geyser 25 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of inner tank 9 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of inner tank 6 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of Inner tank 9 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of Inner tank 6 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Havells/Lexus/Crompton
S&F in replacement of indication lamp (Green/Red) as per required at site all as specified & directed.
S&F in replacement of thermal Auto cut of range 0-90 degree centigrade (ISI marked) complete all as specified and directed.
S&F in replacement of geyser heating element 1.5 KW (ISI marked) round type/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement of geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement of circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked) all as specified & directed
S&F in replacement of bottom plate as per existing size (ISI Marked) all as specified and directed
S&F in replacement of Geyser assembly (nine holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) complete all as specified and directed
S&F in replacement of Geyser assembly (six holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) all as specified and directed
S&F in replacement of electric storage water heater of capacity 25 litres of five star rating, AC 230 volts with four numbers nut bolts duly groutted in walls including all standard accessories with flexi connection pipe of 450 mm size, glass line tank , NRV complete all as specified and directed . Make: Havells/CG/usha/Bajaj
Taking down carefully unserviceable exhaust fans of any size from its position, dismanteling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Defective parts like ball bearing, bush bearing and motor rewinding, shaft, condensor, rubber shackle will be measured and paid separately
S&F in replacement of ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed Make : SKF/TATA/Universal/polar
S&F in replacement of condenser capacity 4/3.15/2 MFD all as specified and directed. Make : Usha/Universal/ Keltran
Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as specified and directed.
M&L for burnt out rewinding exhaust fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 280 to 450 mm sweep all as specified and directed.
S&F in replecement of blade suitable for exhaust fan 300/450mm, size as that of existing defective one all as specified and directed. (ISI Marked)
M&L in replacement of sub main wiring in PVC casing and caping of required size 2x6 sqmm PVC insulated multistrand copper conductor with 01x4 sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Make : Havells/ Plaza/ Polycab Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 4sqmm conductor with casing caping will be measured as one length.
Supply and fix in replacement of cable PVC insulated multi stranded aluminium conductor 1100 volt grade heavy duty served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire of size 10 sqmm 2 core flat all as specified and directed. Make : Havells/Plaza/Polycab
Supply and fix in replacement of LED slim square panel light fitting, 36 Watt, 2x2 feet edge-light luminaire suitable for arm strong/grid ceiling for low ceiling and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make: Havells cat part No STRATO2X2PLR36WLED840MOD or equivalent Philips/Bajaj/wipro
Supply and fix in replacement of PVC flexible pipe of size 20 mm dia all as specified and directed.
S & F in replacement of switch socket combination15 Amp including PVC gang box and fixing screw ISI marked. Make : Havells/Anchor/legrand/HPL
S&F in replacement of switch socket combination 5 Amp including PVC gang box and fixing screw ISI marked. Make : Havells/Anchor/legrand/HPL
M&L in replacement of 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked all as specified and directed. Make : Havells/Polycab/Finolex.
M&L in replacement of 2.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 volts grade ISI Marked all as specified and directed. Make : Havells/Polycab/Finolex.
M&L in replacement of 4 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked all as specified and directed. Make : Havells/Polycab/Finolex.
Supply and fixing in replacement PVC insulation tape of size 20mm dia IS marked.
Supply and fixing in replacement electric ballast 36/40 Watts 240 Volts 50 Hz all as specified.
Excavation in trenches not exceeding 1.5 metre width and not exc 1.5 metre deep for laying of pipe line and getting out in hard dense soil all as specified and directed.
Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in soil all as specified and directed.
Removing surplus soil to a distance nexc. 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
Dismentaling and taking out old existing unserviceable GI pipe of size 100 mm dia from trenches/ under floor, roads, paths or from walls/poles/ducts all as specified and directed (Note:- Excavation & earth work shall be measured and paid for separately under respective item of this schedule)
All as per Item No 89 here-in-before but of size 80 mm bore
All as per Item No 89 here-in-before but of size 50 mm bore
All as per Item No 89 here-in-before but of size 40 mm bore
All as per Item No 89 here-in-before but of size 25 mm bore
All as per Item No 89 here-in-before but of size 20 mm bore
All as per Item No 89 here-in-before but of size 15 mm bore
S&F 80 mm bore GI tubing medium grade with all fittings, laid in trenches, including flanges after a interval of every 03 metre length duly welded, nuts & bolts gaskets and all accesories required for completion of work all as specified and directed. Make : Jindal/Tata/Prakash Surya.
All as per Item No 96 here-in-before but of size 50 mm bore
All as per Item No 96 here-in-before but of size 40 mm bore
All as per Item No 96 here-in-before but of size 25 mm bore
All as per Item No 96 here-in-before but of size 20 mm bore
All as per Item No 96 here-in-before but of size 15 mm bore
Re-laying Including, jointing threading into trenches/wall/floors GI water tubing including all fittings and accessories etc bore of pipe 100 mm, all as specified and directed.
All as per Item No 102 here-in-before but of size 80 mm bore
All as per Item No 102 here-in-before but of size 50 mm bore
All as per Item No 102 here-in-before but of size 40 mm bore
All as per Item No 102 here-in-before but of size 25 mm bore
All as per Item No 102 here-in-before but of size 20 mm bore
All as per Item No 102 here-in-before but of size 15 mm bore
Dismantling/taking out old unserviceable gate valve and supply and fixing new gun metal gate valve/globe valve ISI marked with Iron wheel head screwed both end for GI tubing of size 15 mm dia. Make : Zoloto/Leader/L&T/Kirloskar
All as per Item No 109 here-in-before but of size 20 mm dia
All as per Item No 109 here-in-before but of size 25 mm dia
All as per Item No 109 here-in-before but of size 40 mm dia
All as per Item No 109 here-in-before but of size 50 mm dia
Dismantling and taking down of unserviceable accessories of water supply lines of any size i.e. Tee, Union, sockets, reducers, elbow & plug IS marked as required at site to arrest the leckage of water supply line including excavation & earthwork, returning filling, removing, cutting & threading for under mentioned items ser No 30 to73 all as specified an directed at site. Note : Cost of material i.e. tee, elbow, union,socket, reducer socket, nipple, plug saddle piece of any size required at site will be measured saperately in respective items.
Supply & fix GI union 100mm dia ISI marked.
Supply & fix GI union 80mm dia ISI marked.
Supply & fix GI union 50mm dia ISI marked.
Supply & fix GI union 40mm dia. ISI marked.
Supply & fix GI union 25mm dia. ISI marked.
Supply & fix GI union 20mm dia ISI marked.
Supply & fix GI union 15mm dia. ISI marked.
Supply & fix GI nipple 100mm dia 100 mm long,ISI marked.
Supply & fix GI nipple 80mm dia 100 mm long,ISI marked.
Supply & fix GI nipple 50mm dia 100 mm long, ISI marked.
Supply & fix GI nipple 40mm dia 100 mm long. ISI marked.
Supply & fix GI nipple 25mm dia 100 mm long. ISI marked.
Supply & fix GI nipple 20mm dia 100 mm long. ISI marked.
Supply & fix GI nipple 15mm dia 100 mm long ISI marked.
Supply & fix GI socket 100mm dia ISI marked.
Supply & fix GI socket 80mm dia ISI marked.
Supply & fix GI socket 50mm dia ISI marked.
Supply & fix GI socket 40mm dia ISI marked.
Supply & fix GI socket 25mm dia ISI marked.
Supply & fix GI socket 20mm dia ISI marked.
Supply & fix GI socket 15mm dia ISI marked.
Supply & fix GI elbow 15 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI elbow 20 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI elbow 25 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI elbow 40 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI elbow 50 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI elbow 80 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI tee all equal of size 20 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI tee all equal of size 25 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI tee all equal of size 40 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI tee all equal of size 50 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI reducer socket 20 mm/15 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI reducer socket 25 mm/15 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI reducer socket 40 mm/15 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI reducer socket 50 mm/15 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI reducer socket 25 mm/20 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI reducer socket 40 mm/20 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI reducer socket 50 mm/20 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI reducer socket 40 mm/25 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI reducer socket 50 mm/25 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI plug of size 20 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI plug of size 25 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI plug of size 40 mm dia suitable for GI Pipe medium grade ISI marked.
Supply & fix GI plug of size 50 mm dia suitable for GI Pipe medium grade ISI marked.
Repair of service water tanks leakage from inlet pipe and connected to float valve by removing the short peace of pipe/barrel nipple from the RCC/PVC service tanks and replace the same and arrest the water leakage by using the water proofing material.
Supply and fixing in repairs of ball valves high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed on 25 mm dia of pipe (minimum weight 455 gms) all as specified and directed
All as per Item No 160 here-in-before but of size 20 mm dia of pipe (minimum weight 210 gms)
All as per Item No 160 here-in-before but of size 15 mm dia of pipe (minimum weight 142 gms)
M&L for PCC block masonry valve pit of size 900mm x 900mm x 900mm (internal dimensions) with precast cement concrete block walling 200 mm thick in PCC 1:3:6 type-C-1 using 20mm graded crushed stone aggregate and 10 mm thick plastering in CM 1:4 on internal and external surfaces with and including 40x40x6 mm mild steel angle iron frame and 3 mm thick MS sheet cover with locking arrangement and 1 No, 50 mm size 4 lever lock with key in duplicate of make : Navtal or equivalent, including painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer including necessary excavation & earthwork in any type of strata all as specifiled and directed.
All as per item No 163 above but valve pit of size 600mm x 600mm x 600mm.
M&L rendering 15mm thick in cement mortor 1:4 on stone massonary surface other than fair face of brick work, finishing the surfaces even and fair without using extra cement all as specified and directed.
S&F in repairs of cast iron sluice valve of size 100 mm bore class-I PN-1.6 with gun metal spindle both ends flanged with all fitting all as specified and directed. Make : Kirloskar/leader/Kartar.
S&F in repairs of cast iron sluice valve of size 80 mm bore class-I PN-1.6 with gun metal spindle both ends flanged with all fitting all as specified and directed. Make : Kirloskar/leader/Kartar.
Supply and fix galvanised iron floange on existing pipe of 80mm bore (02 Nos in each pipe) with nuts, bolts and washers complete all as specified and directed.
Supply only calcium Hypochlorite with chlorine content of minium 65% to 70%, Moistrure and others percentage by Mass 5 to 10%, Stability loss maximum 10%, Mesh passing through - 100 BSS should be max 1.5% with grannuals and quantity shall be 190 to 250 grams per one lakh ltrs of water to achieve one PPM at injection point available in 45 kg containers/drums of calcium based grannuals, ISI marked all as specified and directed. Make:- Sree Rayalaseema Hi Strength Hypo Ltd. Brand Name :PURI CHLOR/AQUAFIT (Chemical Division) or its equivalent make as approved by GE.
Supply only crystal alum suitable for potable water.
Supply only bleaching power ISI marked grade-I in polythene bag of 25 Kg each all as specified and directed.
Supply & fixing in replacement shock treatment chart of size 0.72mmx0.52mm printed in English, Punjabi, Hindi, framed on all sides with wooden beading and glazing with 3mm thick ordinary glass all as specified and directed.
Taking out worn winding of centrifugal pump motor stator of capacity 5 to 10 HP carefully and rewinding the same with existing size of super enamelled copper winding wire, including necessary varnishing and insulating material baking etc, transportation to workshop and back at site all as directed by Engineer-in-Charge.
Centrifugal motor pump of set of 5 HP to 10 HP servicing by dismantling and strip opening the motor including disconnecting the cable connections and coupling of the motor, removing the starter and rotor units, bearings, servicing the motor assembly including cleaning the corbon deposits with corbon tetra chloride, greasing the bearings etc, heat varnishing the motor windings by applying varnish and keeping the windings into the hot air oven till the mositure evoporates completely at authorized workshop and refixing the same after repairs including connecting up of the electric connections including testing and commissioning and to achieve the required water discharge as per manufacturer recommendation all as specified and directed. Notes:- (i) Rates for transportation of pump sets to workshop and back to site shall be deemed to inclusive in the quoted unit rates. (ii) Spares and rewinding/heat varnishing for the motor will be measured and paid separately.
Supply only ball bearing suitable for motor to centrifugal motor pump set of 5 to 10 HP capacitiesall as specified & directed.
All as per item No 175 here in before but ball bearing non driving end suitable for pump.
All as per item No 175 here in before but GM bush
All as per item No 175 here in before but MS pump shaft
Testing of water for chemical test and bacterial test complete report in respect of water sample of Harshil & Sukhi station from IIT Roorkee.
M & L for cleaning of water storage RCC semi under ground sump, 25000 Gallon capacity pumping out/taking out residual muddy water using mud pump or by manually including removing all sludge and dirt from wall and floors of sump and from pipe etc., by applying bleaching powder and by scrubbing with wire brushes and taking out all sludge/salt from sump and removal to a distance exceeding 50metre but n.exc 100metre complete all as specified and directed by Engr-in-Charge. The empty sterized with 2% solution of potassium permanganate and including two coat of synthetic enamel paint to external surface of the tank writting, location, capacity and date of cleaning with white paint over black paint firm and hand wrritting over a black paint with synthetic enammelled paint etc complete for entire satisfaction to the to the Engineer-in-Charge.
All as per item No 180 here in before but 10000 Gallon capacity
All as per item No 180 here in before but 1000 Ltrs capacity
All as per item No 180 here in before but 500 Ltrs capacity
M&L two coats of water soluable epoxy paint (potable grade) over a coat of primer on new or old plastered surface including preparation of surface all as per manufactures instruction all as specified and directed.
Supply and fixing integral water proofing compound all as specified and directed.
Supply & fix in repairs cast iron air release valve with two air outlest, 80mm dia bore including masonry work for stand post of air release valve all as specified and as directed by Engineer-in-Charge.
M/S Swarn Constructions
JHURI PRASAD AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .