Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC DHALIWAL | FATEHGARH SAHIB | PUNJAB | 140402 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.2 L+₹43,381.68 (2.44%)Accepted-AOC VPO MAJARI TEHSIL SHRI NAINA DEVI DISTT BILASPUR HP | L2 | Accepted-AOC Accepted | |
| 3 | L3₹18.9 L+₹1.1 L (6.27%)Accepted-AOC VPO TEHSIL JAWALI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L3 | Accepted-AOC Accepted |
Tender Value
Refer Docs
EMD Value
₹21,250
Closing Date
12 Feb 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Jal Shakti Division Bilaspur
Retrofitting and source level augmentation of various left out habitations under JJM 3rd phase of Jal Shakti sub-Division Swarghat in Tehsil Sh. Naina Devi Ji District Bilaspur. (LWSS Behal Swahan and Ree, Behal old an GWSS Mehla ( SH Construction of
2021_HPIPH_43993_1
BLP-BLP00-736
Open Tender
Civil Works
Item Rate
180 days
Under JSV Sub Division Swarghat
Please refer tender documents
6 documents required · 6 mandatory
₹400
Yes
EE Jal Shakti Division Bilaspur
₹21,250
Yes
17 Jul 2021
3 Feb 2021
12 Feb 2021
3 Feb 2021
12 Feb 2021
3 Feb 2021
3 Feb 2021 - 11 Feb 2021
120 days
Amount
Excavation in foundation and trenches etc.(in pipes and pits) in all kinds of soils such as pick work, jumper work, blasting in soft/hard rock, chiselling/wedging out of rock/where blasting prohibited) saturated soil stacking the excavated soil as directed by the Engineer-in-charge clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by the Engineer –in-charge in all leads and lifts.
Providing and laying cement concrete 1:3:6 (1cement: 3sand: 6 graded stone agg. 20mm nominal size) excluding the cost ofcentering & shuttering in foundation and plinth in all leads and lifts.
Providing and laying cement concrete 1:1.5:3 (1cement: 1.5 sand:3 graded stone aggregate 20mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-
Foundation footings base of columns and the like and mass concrete and to the entire satisfaction of the Engineer-in-charge.
Wall any thickness but not less than 0.1mtr thickness attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level and to the entire satisfaction of the Engineer-in-charge.
(i) floor four level to floor five level
Column,pillars,posts & struts upto floor two level
(ii) floor two level to floor three level
(iii) floor three level to floor four level
(iv) floor four level to floor five level
Lintels,beams gorders bressumers & cantilevers upto floor two level
(ii) floor two level to floor three level
(iii) floor three level to floor four level
Arches upto floor two level:
(ii) floor two level to floor three level
(iii) floor three level to floor four level
Suspended floor roofs landing shelves and their supports balconies, beams girders breasumers and cantilevers up to floor two level.
(i) floor two level to floor three level
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor two level.
(i) Foundation,footing,bases of columns etc.and mass concrete in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
Flat surfaces such as soffits of suspended floor landings and the like up to 200mm thickness and to the entire satisfaction of the Engineer-in-charge.
Vertical surfaces such as walls (any thickness) partitions and the like including attached pilasters buttresses, plinth and string courses and the like and to the entire satisfaction of the Engineer-in-charge.
Beyond 4.00 mtr.height.
(iv) Columns,pillars.posts & struts.upto 4.00 mtr.
(b) Beyond 4.00 mtrs.
(v) Beams, cantilever, girders & lintels.
Sides & soffits of beams,beam haunchings, catilevers, bressumers & lintels not exceeding 1.00 mtr.depth in all ht.from floor.
Providing form work of ordinary timber plankings, so as to give a rough finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4.00 mtrs.height.
Beyond 4.00 mtr.height.
Providing Tor steel reinforcement for RCC work including bending,binding & placing in position complete upto floor two level.
Providing in RCC work smooth finishing of the exposed surface with cement mortor 1:3 (1cement :3 Sand) complete in all respect within all leads & lifts.
Finishing wall with water proofing cement paint of approved brand & maunfacture and of required shade on undecorated wall surfaces (two coats) to give an even shade after throughly brushing the surface to remove all dirt & remains of loose powedered material etc.
Prov. & fixing Man hole cover with frame (Size 680x680) with MS sheet 2.00thick with hinges on MS angle iron frame 32x32x3 mm supporting with 40x5 mm flat with base frame 40x40x5mm duly welded and fixed in RCC slab with anchor bolt 12mmx150mm i/c cost of welded charges , carriage fixing and applaying priming coat and locking arrangement complete in all respect as per entired satisfiction of Engineer-in -charges.
Laying GMS/MS Pipes conforming to relevants BIS codes of below mentioned diameters fully jointed with MS Flanges of Table - 17 as per IS :6392 - 1971 excluding the cost of excavation in trenches complete in all respect within all leads & lifts.
65mm dia
80mmdia
Steel work welded in built up sections,trusses & framed work i/c cutting, hoisting,fixing in position & applying a priming coat of red paint.In grating,framed guard bars,ladders,railing,brackets & similar works.
Laying GMS Pipes conforming to IS 1239 - 1979 (Part-1) screwed & socketed joints (Light grade) excluding the cost of excavation in trenches
25mm dia
Providing & fixing CI sluice valve (with hand wheel) as per IS:780 - 1984 Class-I upto 300 mm dia i/c brass spindle & as per 2906 - 1984 Class II for diameters more than 300 mm complete with bolts,nuts,rubber insertion etc,(The tail pieces if required shade etc.
65mm dia
80mm dia
Providing & fixing bends of required degrees made from parent tubes conforming to relevant codes fully flanged with MS Flange of Table - 5 conforming to IS: 6392 - 1971 complete in all respect within all leads & lifts.
65mm dia
80mm dia
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 Cement: 3 Sand: 6graded stone aggregate 20 mm nominal size) complete in all respect within all leads & lifts.
Providing under layers for plinth protection 75 mm thick (unconslidated) bed dry brick/stone aggregate 40 mm nominal size well rammed & grouted with fine sand i/c preparation of ground complete in all respect within all leads & lifts.
Constructing chamber for sluice valve, with CI surface box 100mm top dia, 160mm bottom dia and 180mm deep (inside) with chained lid RCC top 1:2:4 mix (1cement: 2saand: 4 graded stone agg. 20mm nominal size) 100mm thick foundation concrete 1:5;10 mix (1cement:5sand: 10 graded stone agg. 40mm nominal size) and inside plastering with cement mortar 1:3 (1cement: 3sand) finished with a floating coat of neat cement including curing complete.600x600x750mm inside size with 150mm thick walls of RCC 1:2:4 (1cement: 2sand: 4 graded stone aggregate 20mm nominal size) complete with form work and reinforcement with 6mm bars at not exceeding 150mm centers both ways.
P/Fixing of below items required for OHSR complete.
Lightening Conductor
Water measurement gauge
Vent Pipe i/c CI cowl complete
Flanged bell mouth a/w puddle collars
Expansion joints
Structural design & drawing
Soil testing report for Bearing capacity of soil
MS Kamal Dev Sharma
Sushant Puri
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .