Director TMC
Engineering services, Ground Floor, Pushp Building (Old St. Jude Building), ACTREC
SITC of Stand-Alone Fire Hooters at CRC and D-Block
2026_TMC_926740_1
ATA/ET-51/Fire Hooters/2026
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
30 days
ACTREC, Kharghar
AS PER TENDER DOCUMNET
6 documents required · 6 mandatory
₹0
₹5,727
ACTREC, Kharghar
18 Sept 2026
18 Sept 2026
13 Oct 2026
18 Sept 2026
12 Oct 2026
18 Sept 2026
18 Sept 2026 - 28 Sept 2026
29 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installing, testing and commissioning of addressable fire monitor module for flow switches, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device complete as required. Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982 Reed relays, EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MM | 6 | Each | - | - |
| 2 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. | 6 | Each | - | - |
| 3 | Supply, Installation, Testing, Configuring in Software, Commissioning of power supply unit from 230 V UPS to 24 V DC, 6 A power supply for notification for Analogue Addressable System.
Refer Technical Specifications | 2 | Each | - | - |
| 4 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. | - | Meter | - | - |
| 5 | Removing and refing ceiling if required at any point in wire erection | 1 | Lot | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
TDET51.pdf
Tender Documents • 1.99 MB
AnnexureForm.xls
Additional Documents • 0.12 MB
BOQ_973876.xls
BOQ • 0.29 MB
AgencyInformation.xls
Additional Documents • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .