| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹28.7 L+₹1.9 L (6.94%)Rejected-Finance 95 A GOVIND NAGAR RACE COURSE OPP GURUDWARA DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹38.0 L+₹11.1 L (41.5%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹38.7 L+₹11.9 L (44.3%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹39.0 L+₹12.1 L (45.2%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
Tender Value
₹44.7 L
EMD Value
₹89,400
Closing Date
13 Oct 2020, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
REPAIR/ MAINTENANCE OF SUBMAIN WIRING , ELECTRIC METER BOARDS, MCB DBs AND SERVICE CABLE CONNECTED WORKS AT GE CLEMENT TOWN
2020_MES_378222_1
GE/CLT/ Of 2020-21
Open Tender
Civil Works
Item Rate
210 days
GE Clement Town
Class D Cat b(i)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town
₹89,400
Yes
19 Dec 2020
16 Sept 2020
15 Oct 2020
17 Sept 2020
13 Oct 2020
24 Sept 2020
Amount
Taking down old unserviceable meter box of any size & any type from wall by disconnecting all electrical connections complete all as directed & directed.
Taking down energy meter from unserviceable meter box carefully and re-fixing on new panel board, sealing with sealing compound and wire complete all as directed & directed.
Taking down carefully sub main wiring of any size including wooden batten etc. and making good the disturbed surface of wall/floor to match with the existing surfaces complete all as specified and directed.
M&L for electric meter box of size 0.90x0.70x0.25 mtr made out of 2.0mm thick CRCA sheet with powder coated including fixing of 40 Amps MCB, DP - 05 Nos (One no MCB DP for individual meter) and MCCB 4 pole 125 Amp rating,25 KA - 01 No, TPN Busbar of rating 200 Amps for main incoming including RYB 3 phase indication including all necessary connection by providing aluminium lug of suitable size, complete all as specified and directed.
M&L for electric meter box of size of 1.35x0.70x0.25 mtr for made out of 2.0mm thick CRCA sheet with powder coated including fixing of 40 Amps MCB, DP - 07 Nos (One no MCB DP for individual meter) and MCCB 4 pole 125 Amp rating,25 KA - 01 No, TPN Busbar of rating 200 Amps for main incoming including RYB 3 phase indication including all necessary connection by providing aluminium lug of suitable size, complete all as specified and directed.
Supply and fixing sheet metal enclosure double door type for MCCB DB VTPN 4 Way with 160 Amps , 36KA, 4 Pole MCCB of Make legrand, Hair, Schnider complete all as directed & directed.
Supply and fixing in repair sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with complete all as directed & directed. Make- Legrand /Hair/Schneider
Supply and fixing in repair sheet metal enclosure double door type for MCBs DB TPN 415V AC 4 way with complete all as directed & directed. Make legrand / Hair, Schnider
Supply and fixing in repair sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with complete all as directed & directed. Make- Legrand /Hair/Schneider
Supply and fixing in repair MCB 5 to 30 Amp 'C' series 10 KA repturing capacity complete all as directed & directed. Make legrand / Hair, Schnider
S&F in repair MCCB 415 volts, 16 KA, 3 pole, 125 Amps rating fixed type for main incoming complete all as specified and directed.
Supply and fixing in repair MCB isolator SPN 40 Amp 240 V AC 10 KA repturing capacity complete all as directed & directed. Make -Make legrand, Hair, Schnider
Supply and fixing MCB isolator 4 pole 63 Amps 240 V 10 KA repturing capacity complete all as directed & directed. Make -Legrand, Hair, Schnider
S&F MCB Isolator TP 40 Amp complete all as directed & directed. Make: Legrand , Hair, Schnider
M&L in repair for sub main wiring two single core 4 Sqmm,FR, PVC insulated unsheathed stranded copper conductor cable 1100 Volts, drawn in and including rigid PVC conduit 25mm dia, medium grade, concealed/surface/as per existing in wall including cutting with and including one run of 4.0 Sqmm, FR, PVC insulated unsheathed copper conductor cable as earth wire and chases connected with main earth dolly complete all as specified and directed
M&L in repair for sub main wiring two single core 4 Sqmm PVC , FR, insulated unsheathed stranded copper conductor cable 1100 Volts, drawn in existing conduit with and including one run of 4.0 Sqmm , FR, PVC insulated unsheathed copper conductor cable as earth wire and chases connected with main earth dolly complete all as specified and directed
M&L for in repair sub main wiring two single core 6 Sqmm, FR, PVC insulated unsheathed stranded copper conductor cable 1100 Volts, drawn in and including rigid PVC conduit 25mm dia, medium grade, concealed/surface / as per existing in wall including cutting with and including one run of 6.0 Sqmm , FR, PVC insulated unsheathed copper conductor cable as earth wire and chases connected with main earth dolly complete all as specified and directed.
Supply and fixing in repair switch piano flush type single pole, one-way 5 Amps, 240 Volts AC complete all as directed & directed.
Supply and fixing in repair switch piano flush type single pole, one-way 15 Amp, 240 Volts AC complete all as directed & directed.
Supplyand fixing in repair bell push piano flush type single pole one way 5 Amps complete all as directed & directed.
Supply and fixing in repair switch piano flush type single pole, two way 5 Amp, complete all as directed & directed.
Supply and fixing in repair socket out let 2 in 1,3 pin 5 Amps flush type complete all as directed & directed.
Supply and fixing in repair socket out let 2 in 1,3 pin , 5 Amp and 15 Amp flush type (multi) complete all as directed & directed.
Supply and fixing Buzzer ding dong AC 230 Volts single pole complete all as directed & directed.
Supply and fixing in repair batton/angle holder insulated body with back plate suitable for batten fittings complete all as directed & directed.
Supply and fixing in repair stepped type electronic fan regulator flush socketed type complete all as directed & directed. Make -Anchor/C&S/CONA
Supply and fixing in Electronic dimmer, 45watt, 250V Flush type complete all as directed & directed. Make -Anchor/C&S/CONA
Supply and fixing in repair Ceiling fan capacitor 2.5 mfd, 240 Volts AC complete all as directed & directed.
Supply and fixing in repair LED candle Lamp E14, WW/CDL 3Watt complete all as directed & directed. Make-Crompton /Havells/Wipro
Supply and fixing in repair LED Lamp E27, WW/CDL 5Watt complete all as directed & directed. Make- Crompton/Havells/Wipro
Supply and fixing in repair LED Deco Lamp B22, 0.5Watt complete all as directed & directed. Make- Crompton/Havells/Wipro
Supply and fixing in repair LED Lamp B22,6500K 30 watt complete all as directed & directed. Make- Crompton/Havells/Wipro
Supply and fixing in repair choke 1 x 40/36 watt electronic complete all as directed & directed. Make- Bajaj/Havells/Crompton
Supply and fixing in repair Fluoescent Tube Rod 36 watt 6500K, 1.2m complete all as directed & directed. Make- Bajaj/Havells/Philips/Crompton
Supply and fixing in repair LED T8 tubular lamp 18/20 watt complete Cat part No-LGT8-20-865-2 suitable for batten fitting complete all as directed & directed. make Cromption or equivalent make in havells/ philips/ C&S.
S & F in repair LED Recessed type full open 2X2 Tiles, Glare free uniformillumination with longer life and less maintenance Polaris NIO- I, of /Cat Part No LCTLRNE-36-FO-CDL of Crompton or equivalent make in Havells /C&S complete all as directed & directed.
S& F in repair Mirror Light LED Cat No LCL-07-CDL of Make-Crompton /Cat part noor ,C&S or Equivalent complete all as directed & directed.
S& F in repair wall mounted LED Box type fitting Blue colour end caps pre-wired for LED with LED T8 tubular lamp complete all as directed & directed Cat part No DMLN 1 LT8-16 & LED, LGT8-20-865-2 of Crompton, oe eqvt make in Havells ,& Philips.
Supply, installation in repair, testing commissioning and sealing of temper proof electronic energy; meter 230/240 Volt capaciaty 10-60Amps (Single phase) optical port feature including electric connection incoming and outgoing with PVC insulated unsheathed multi stranded copper conductor FR cable single core 1100 Volt grade of size 6/4 sqmm with proper tinned copper lugs and rigid PVCconduit medium grade 20 mm dia surface concealed where required and taking out of old electric meter and unserviceable cable complete all as specified and directed Make- L&T /HPL/Secura.
M&L in repair for under ground cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 16 sqmm 4 core complete all as directed & directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out cables, pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete complete all as directed & directed.
Material and labour for dry river sand cushioning over and around the cable for cable protection in trenches, leveled and punned down complete all as directed & directed. Note: The punned down thickness shall be measured for payment.
Supply and laying , reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmX 150mmX40mm complete all as specified & as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as directed & directed.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed & directed.
M & L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground all as specified and directed (earth pit not less than 2.25m below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to GI wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanized iron all as shown in Electrical Plate No. 3 connected to earth test point all as specified or indicated and testing on completion including necessary excavation and earth work in any type of strata, PCC pit and RCC cover, GI protection pipe 15mm bore light grade up to 7.5m length earth lead up to meter board, watering pipe, wire mesh etc complete all as directed & directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed. 2. Unless otherwise specified the rates for PCC/RCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule "A" notes for details.
M/S Manmohan Singh Anand
Flint India
CHANDRA ENGINEERS
Bhanu Prakash
BHAGAT JI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .