| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹1.4 Cr+₹7.5 L (5.65%)Rejected-Finance | ₹1.4 Cr+₹7.5 L (5.65%) | L2 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| 3 | L3₹1.4 Cr+₹8.5 L (6.40%)Rejected-Finance OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | ₹1.4 Cr+₹8.5 L (6.40%) | L3 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| 4 | L4₹1.5 Cr+₹12.3 L (9.25%)Rejected-Finance | ₹1.5 Cr+₹12.3 L (9.25%) | L4 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| 5 | L5₹1.6 Cr+₹31.8 L (23.9%)Rejected-Finance | ₹1.6 Cr+₹31.8 L (23.9%) | L5 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
Tender Value
₹57.7 L
EMD Value
₹1.1 L
Closing Date
19 Sept 2023, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
COMPLETION OF INCOMPLETE WORK SERVICES FOR INDUCTION OF RECCEE ASSETS AT AFS TEZPUR
2023_MES_616300_1
88496/TEZ/R and C/E8
Open Tender
Civil Works
Lump-sum
120 days
Tezpur
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE (I) (P) AF Tezpur
₹1.1 L
Yes
3 Nov 2023
29 Aug 2023
21 Sept 2023
29 Aug 2023
19 Sept 2023
12 Sept 2023
Amount
SCHEDULE 'A' PART- I, (BUILDINGS/STRUCTURES) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
Construction of incomplete/ balance items of works of ‘O’ Level Reccee Lab building in single storey, RCC framed structure complete all as shown on drawings and as specified. (i) The detail of incomplete items of works and their quantities are furnished as Appx 'A' to BOQ for purpose of guidance of tenderer only. (ii) Please note that NO claim whatsoever on any account of any errors/ inaccurancies on incomplete quantities given in Appx 'A' inserted by MES shall be entertained at a later. (iii) The tenderer shall workout incomplete/ balance items of works independently on visiting the site personally and quote their lumpsum amount accordingly for completion of buildings all as shown in drawings and as specified.
SCHEDULE 'A' PART- II ( SITE CLEARANCE / AREA DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- V (ROAD/ HARDSTANDING) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VI ( SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- VIII (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IX (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART -X (Air Conditioning) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART -XI (MISCELLANIOUS ITEMS INCLUDING ITEMS FOR DEFECT RECTIFICATION (B/R & E/M ITEMS)) Note:- This schedule is not pre-priced by MES.
S&F modular metal flush box 12 module and modular cover plate with frame complete all as specified and directed.
Supply and fix LED fitting 14 watt recess mounted type complete all as specified and directed. (Make : -Wipro model No LD74-121-XXX-65XX or equivalent model of make as specified in PS)
Supply and fix LED fitting 39 watt industrial type recess mounted type complete all as specified and directed. (Make : -Wipro model No LE10-491XXX-57HCSL or equivalent model of make as specified in PS)
Supply and fix LED fitting 40 watt industrial type recess mounted type with Pro LED tube complete all as specified and directed. (Make : -Wipro model No WC012-2208 or equivalent model of make as specified in PS)
S&F 1200mm sweep ceiling fan and connecting up of cable from ceiling rose or connector to fan complete all as specified. (Make: Havells model No. SS390/ Bajaj model - Speed star, Excel, ultima or equivalent model of make as specified in PS)
S&F exhaust fan 300mm sweep with louvers, metal type, and connecting up of cable from ceiling rose or connector to fan all specified and directed. (Make: Havells model - Ventil air DB/ Bajaj model - 12" Freshee MK 11, 12" Maxima DX or equivalent model of make as specified in PS)
S&F Heavy duty exhaust fan 450mm sweep with louvers and connecting up of cable from ceiling rose or connector to fan all specified and directed.
S&F MCBs SPN 40A to 63 A ("C" curve) 10 KA breaking capacity complete with cable connection with copper lugs complete all as specified and as directed
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized steel wire 4mm dia earthing lead upto 7.5m from testing point fixed by means of galvanized iron or steel bolts nuts check nuts and washers, GI earth wire protected by 15mm bore light grade galvanized iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore medium grade galvanized iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness)all around the earth electrode with concrete earth pit in PCC (1 : 3 : 6) type C-1, cast iron frame, 50mm thick pre-cast RCC M-25 design mix cover slab size 450x450x50 mm reinforced with 8mm dia TMT bar 10cm C/C and suitable handle of 10mm dia round bar, including necessary excavation, earth work in soft/loose soil and disposal off spoil to a distance n.exc 50m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part I and as directed.
Supply and install 100 A, 3 phase, 415 volts, 50 Hz, Ip-55, aluminium conductor bus bar trunking system with housing made from 0.8 mm hot galvanised steel with overall dimension of 39 mm X 97 mm with provision of tap off in every 1000 mm, tap-off boxes should be made from thermoplastic material and bus bar trunking design will compliance to IEC 439 I & II hanging from the ceiling by means of hanger including all accessories complete all as specified.
S & F MCB single pole 6 - 32 Amps, 10 KA ruturing capacity and connected with suitable size of copper lugs to bus bar complete all as specified and as directed
S & F MCB single pole and neutral 6 -32 Amps, 10 KA ruturing capacity and connected with suitable size of copper lugs to bus bar complete all as specified and as directed
S & F MCB single pole and neutral 40 - 63 Amps, 10 KA ruturing capacity and connected with suitable size of copper lugs to bus bar complete all as specified and as directed
S & F MCB triple pole and neutral 20 Amps, 10 KA rupturing capacity and connected with suitable size of copper lugs to bus bar complete all as specified and as directed
Bringing approved earth from outside MOD land and depositing where directed at a level n.exc. 1.50 metre above the starting points including raising earth, spreading in layers n. exc. 30cm thick, watering, ramming/rolling and finished to required size & shape etc n. exc. 1.5m high from base complete all as specified and as directed. Note:- 10% will be deducted for bulkage.
M & L for construction of masonry valve pit chamber (Masonry) of size internally dimension 90 cm X 90 cm x 90 cm depth (internal dimension) with sub class'B' bricks in cement mortar (1:4) and 15mm thick plastering in cement mortar 1:4 and PCC (1:3:6) type C-2 in foundation PCC (1:2:4) type B-1 as in bedding and coping including 40 X 6 mm MS angle iron frame, 3 mm thick MS cover plate with locking arrangement and painting to all steel surfaces with two coats of synthetic enamel paints over a coat of red oxide primer including surface preparation all as directed
Boring across the road, pavement, hard standing etc. without damaging the road/pavement/hardstanding for insertion of GI pipe upto 100 mm bore pipe for passing of electric cable through GI pipe not less than1.0 m from GL complete all as directed. NOTE: GI pipe will be measured and paid separately
Design, supply, erect , test and commission of electrically operated overhead travelling crane 2 Ton capacity, Span 7.00 mtrs travel 25 Mtrs long, Hook height 4.50 mtrs from finished floor level, double girder construction with steel structural sections, electrical motors, gear boxes ,long/ cross travel /hoisting mechanism, operated from floor with pendent control movable independent of crab position including provision of track rail / square bar for a bay length of 25 Mtrs (Approx) for long travel, having hoist hook speed @ 3mtrs/min cross travel speed @ 10-12 mtrs/ min and longitudinal travel speed @ 12-15 mtrs / min including shrouded copper bus bar 415V 3 phase 4 wire of appropriate capacity including current collector, supporting brackets, insulators and other standard fixtures and fittings, carriage with double flanged cylindrical wheels, standard hook block, steel wire ropes, sheaves, necessary service platforms, ladders, suitable brakets for all motors, couplings, buffors , including all safety devices such as limit switches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete confirming to As per bureau of Indian Standard IS :800, IS : 807, IS :3177, IS:4137 specifications, all as specified and directed.
DEFECTIVE ITEMS (B/R PORTION) Rectification of defective items of works as listed below in building including Material & Labour related to existing E.S.D. (Electrostatic Dissipative) Floor with 2 layer comprising of Primer NitoPrime 25 of FOSROC or equivalent and under coat finished with 2 mm -3 mm thick Epoxy Resin based static Conductive Floor Topping Nitoflor SL Conductive of FOSROC as per BS 6319 or equivalent approved manufactures specification .ESD Floor shall have surface resistance in range 5x10^4 - 1x10^6 ohms. Copper strip/foil grid for anti Static epoxy based flooring shall be all as per manufactures specifications. Earthing required shall be measured and paid separately. The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Removal of existing defective antistic flooring using some mechanical means as instructed by the Engineer-In-Charge as per manufacturer's guidelines (b) After removal existing surfaces must be cleaned and even and free from all contaminants such as dirt, oil, grease etc. Repairs (blow holes/voids and surface levelling) to the substrate must be carried out using appropriate repair product of manufacturer's FOSROC or equivalent (c) Providing and applying two component epoxy resin based Flo Arm EPW 44 at a consumption of 0.150-250 Kg/m2 depending upon the surface, on well prepared concrete substrate, using roller/ trowel/ squeeze. Allow it dry overnight
(Item No 11.20 Contd-----) (d) Providing and applying Flo Arm CEMPO 2 or moisture barrier onto the primed substrate at a consumption of 2-2.15 Kg/m2 /mm. for 2mm thick apply approx. 4.3 Kg/m2 /mm. do not lay Cempo on dry primer, if primed surface is dried apply recoat of primer mixed density, K/l: approx. 2.15 Kg/l pot life @ 20 degree celcius : 25 minutes Thermal expansion coefficient per degree celcius : approx 15.1*10.6 (Temperture range 20 degree celcius to +60 degree celcius) (According to EN 1770) water absorption coefficient : approx. 0.02 Kg/m2 (e) Providing and applying application of Flo Arm Primer EP -epoxy penetrating primer for concrete surface, using brush or roller and allow to cure for 8-10 hrs (depending upon temperature) (f) M & L self adhesive copper tape of 25mm while wet. Fix copper tapes maintaining a grid of 3m x 3m . Spike shoes should be worn during the procs (g) Providing and applying epoxy resin based, seamless, abrasion resistant, dissipative undercoat Flo Arm SL Conductive Undercoat of surface resistance values ranging 3x10^3-9x10^3 Ohm. Allow it to dry. Providing and applying Epoxy resin based, seamless, self-levelling, Glossy, abrasion resistant, flooring product F/o Arm SL Conductive Top coat with a surface resistance value range 5x10^4-1x10^6 Ohm of desired colour @ 2.00 mm thick, complying to IS 9162 standared having the following technical paramiters: Sample cured for 28 day at 30 Degree Mixed density, Kg/m3 : approx 1.63
DEFECTIVE ITEMS (E/M PORTION) RELATED TO SCH 'A' PART-II, SITE CLEARANCE / AREA DEVELOPMENT AND EARTH WORK Rectifcation of defective items of works as listed below including material & labour related to RFR item description vide Srl Item No 05 of Sch'A' Part-II complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. . (a) Returning, Filling in and ramming shall be carried out at various locations for PPR pipe line as well as LT/HT cables, using excavated soil available sideby/nearby (b) Any other minor / missing items required to complete the work to completely rectify the defect.
RELATED TO SCH 'A' PART-III, INTERNAL ELECTRIFICATION Rectifcation of defective items of works as listed below including material and labour related to Point wiring with 1.5 Sqmm PVC insulated unsheathed single core multistranded copper FRLS conductor cable 1100 volt grade drawn through in and including non metallic PVC conduit (ISI marked) of adequate size, concealed, for one light/ one fan point controlled by one switch including one 1.5 Sqmm PVC insulated unsheathed stranded copper FRLS cable green in colour for earth continuity conductor and connected to earth dolly and to be terminated to modular flush metal boxes with modular cover with outer plates / inner plates etc as per requirement at site for mounting switches, sockets, fan regulators etc including testing on completion complete all as specified and directed. (Note: Modular cover plate and modular flush metal box shall be measured and paid separately) The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Disconneting and removing of defective old wiring (2 runs and 1 Run for earthing complete. (b) Supply and fixing new wiring of 1.5 Sqmm of 3 Runs without any jointing in existing conduits (c) Connecting the new wiring with existing swtich and sockets including testing on complettion complete all as specified and directed by the Engr-in-Charge (d) Any other minor / missing items required to complete the work to completely rectify the defect and make the point wiring functional.
Rectifcation of defective items of works as listed below including material and labour related to Point wiring with 1.5 Sqmm PVC insulated unsheathed single core multistranded copper FRLS conductor cable 1100 volt grade drawn through in and including non metallic PVC conduit (ISI marked) of adequate size, concealed, for one 5 pin 5/6 Amps socket outlet point independent complete including one 1.5 Sqmm PVC insulated unsheathed stranded copper FRLS cable green in colour for earth continuity conductor and connected to earth dolly and to be terminated to modular flush metal boxes with modular cover with outer plates / inner plates etc as per requirement at site for mounting for one 5 pin 5/6 amp socket out let point independent complete including testing on completion complete all as specified and directed. (Note: Modular cover plate and modular flush metal box shall be measured and paid separately). The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Disconneting and removing of defective old wiring (2 runs and 1 Run for earthing complete. (b) Supply and fixing new wiring of 1.5 Sqmm of 3 Runs without any jointing in existing conduits (c) Connecting the new wiring with existing swtich and sockets including testing on complettion complete all as specified and directed by the Engr-in-Charge (d) Any other minor / missing items required to complete the work to completely rectify the defect and make the point wiring functional.
Rectifcation of defective items of works as listed below including material and labour related to Point wiring with 4.0 Sqmm PVC insulated unsheathed single core multistranded copper FRLS conductor cable 1100 volt grade drawn through in and including non metallic PVC conduit (ISI marked) of adequate size, concealed, for 15 Amps switch socket combination metal plug socket on independent board including one 2.5 Sqmm PVC insulated unsheathed stranded copper FRLS cable green in colour for earth continuity conductor and connected to earth dolly and to be terminated to modular flush metal boxes with modular cover with outer plates / inner plates etc as per requirement at site for mounting with 4 Sq mm cable and 2.5 Sq mm cable for earth conductor for 15 Amps switch socket combination/metal plug socket on independent board complete including testing on completion complete all as specified and directed. (Note: Modular cover plate and modular flush metal box shall be measured and paid separately) The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Disconneting and removing of defective old wiring (2 runs and 1 Run for earthing complete. (b) Supply and fixing new wiring of 4 Sqmm of 2 Runs and 2.5 Sqmm 1 run without any jointing in existing conduits (c) Connecting the new wiring with existing swtich and sockets including testing on complettion complete all as specified and directed by the Engr-in-Charge (d) Any other minor / missing items required to complete the work to completely rectify the defect and make the point wiring functional.
Rectification to defective items of works as listed below including material & Labour for related to sub main wiring with 2 runs (P-N) for single core 6 Sqmm (Normal area) stranded PVC insulated unsheathed copper conductor cable 1100 V grade drawn through adequate size PVC non-metallic concealed conduit including 1X4 Sqmm (Nominal area) PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. (Note : Two runs of 10 Sqmm cable, one run of 6 Sqmm earth continuity conductor and one run of PVC conduit shall be measured as one run length). The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Disconneting and removing of defective old sub main wiring (2 runs and 1 Run for earthing complete. (b) Supply and fixing new submain wiring of 6 Sqmm of 2 Runs and 1 Run 4 Sqmm without any jointing in existing conduits (c) Connecting the new submain wiring with existing control/DB including testing on completion complete all as specified and directed by the Engr-in-Charge (d) Any other minor / missing items required to complete the work to completely rectify the defect and make the submain wiring functional. (Note : Two runs of 6 Sqmm cable, one run of 4 Sqmm earth continuity conductor shall be measured as one run length).
Rectification to defective items of works as listed below including material & Labour for related to sub main wiring with 2 runs (P-N) for single core 10 Sqmm (Normal area) stranded PVC insulated unsheathed copper conductor cable 1100 V grade drawn through adequate size PVC non-metallic concealed conduit including 1X6 Sqmm (Nominal area) PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. (Note : Two runs of 10 Sqmm cable, one run of 6 Sqmm earth continuity conductor and one run of PVC conduit shall be measured as one run length) The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Disconneting and removing of defective old sub main wiring (2 runs and 1 Run for earthing complete. (b) Supply and fixing new submain wiring of 10 Sqmm of 2 Runs and 1 Run 6 Sqmm without any jointing in existing conduit (c) Connecting the new submain wiring with existing control/DB including testing on completion complete all as specified and directed by the Engr-in-Charge (d) Any other minor / missing items required to complete the work to completely rectify the defect and make the submain wiring functional. Note : Two runs of 10 Sqmm cable, one run of 6 Sqmm earth continuity conductor shall be measured as one run length.
Rectification to defective items of works as listed below including material & Labour for related to sub main wiring with 4 runs (P-N) for single core 6 Sqmm (Normal area) stranded PVC insulated unsheathed copper conductor cable 1100 V grade drawn through adequate size PVC non-metallic concealed conduit including 2X4 Sqmm (Nominal area) PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. (Note : Four runs of 6 Sqmm cable, two run of 4 Sqmm earth continuity conductor and one run of PVC conduit shall be measured as one run length). The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Disconneting and removing of defective old sub main wiring (4 runs and 2 Run for earthing complete. (b) Supply and fixing new submain wiring of 6 Sqmm of 4 Runs and 2 Run 4 Sqmm without any jointing in existing conduits (c) Connecting the new submain wiring with exsisting control/DB including testing on completion complete all as specified and directed by the Engr-in-Charge (d) Any other minor / missing items required to complete the work to completely rectify the defect and make the submain wiring functional. (Note : Four runs of 6 Sqmm cable, two run of 4 Sqmm earth continuity conductor shall be measured as one run length.)
Rectification of defective items of works as listed below including material and material to related to TPN DB 4 way /8 way related items description vide Srl Item No 24 & 25 of Sch'A' Part-III complete all as specified and directed by Engr-in-Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Disconneting and removing of defective old TPN DB 4 way/8 way. (b) Refixing of TPN DB 4way/8way and the make good by plastering/painting work including matching with existing surface properly complete all as specified and directed by the Engr-in-Charge. (c) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional.
RELATED TO SCH 'A' PART-VII, EXTERNAL WATER SUPPLY Rectifcation of defective items of works as listed below including material & labour related to PPR pipe of size 50mm dia related to item description vide Srl Item No 01 of Sch'A' Part-VII complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Removing old and providing new MS Clamping of existing PPR Pipe which are hanging at site of size 50 mm properly fixed to wall to a length of pipe 6m. (b) After completing clamping work the testing of PPR pipe line (c) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional.
RELATED TO SCH 'A' PART-VIII, EXTERNAL ELECTRIC SUPPLY Rectifcation of defective items of works as listed below including material & labour related to PCC (1 : 2 : 4) coping related to item description vide Srl Item No 03 of Sch'A' Part-VIII for existing 06 nos of steel tubular swaged pole (9 mtr ) complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Demolition of defective coping & providing PCC (1 : 2 : 4) type B-1 using 20mm graded stone aggregate as in coping of pole etc including necessary form work. (b) Any other minor / missing items required to complete the work to completely rectify the defect.
Rectifcation of defective items of works as listed below including material & labour related to item description vide Srl Item No 07 of Sch'A' Part-VIII Cable jointing kit for 11 KV (Earthed) grade complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Removal of defective Cable jointing kit & providing new Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrinking type joint suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm (b) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional.
Rectifcation of defective items of works as listed below including material & labour related to Power transformer capacity 1000 KVA as installed vide Srl Item no 09 of Sch 'A' Part-VIII complete all as specified and directed by Engr-in Charge. The list of defective items/left over items are covered as under and the quoted shall be inclusive of following:- (i) The level of transformer oil in conservator tank needs to topped up . (ii) After topping of oil the dielectric strength of transformer oil now low and hence dehydration of transformer including necessary top up needs to be carried out to maintain dielectric strength for new oil as per IS code. (iii) The breather complete with silica Gel needs to replaced. (iv) The Buchholz relay needs to be re-tested and re-calibrated on installation of RMU at site to ensure protection of transformer. (v) The transformer body has rusted at places and hence the transformer requires re-painting complete as per manufacturers instructions. (vi) As per the direction of CE (AF) Shillong Zone, SEI inspection to be carried out before charging / commissioning of HT installations. (vii) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional for power Transformer.
Rectifcation of defective items of works as listed below including material & labour related to weather proof twin core cable fixed vide Srl Item No 17 of Sch 'A' Part-VIII for existing 06 nos of steel tubular swaged pole (9 mtr ) complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Providing new Weather proof twin core cable with copper conductor of size 2.5 sqmm including removal of old defective wire. (b) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional.
Rectifcation of defective items of works as listed below including material & labour related to steel tubular swaged poles (9 mtrs long) installed / fixed vide Srl Item no 19 of Sch 'A' Part-VIII complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (i) The steel tubular street light poles need to be re-painted with one coat of red oxide primer after proper cleaning the pole surface and there after two coats aluminum paint is to be provided including black and yellow strip to about 1.5 Mtr above Ground . (ii) The wire for street light pole has been laid over the pole between pole box and street light. The same is required to be re done after making holes at suitable height for pass the connecting cable from inside the pole. (iii) Any other minor / missing items required to complete the work to completely rectify the defect.
Rectifcation of defective items of works as listed below including material & labour related to Earth continuity conductor of size 32 x 6mm GI Strip fixed vide Srl Item No 20 of Sch 'A' Part-VIII complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Earth continuity conductor or main earthing lead fixed to wall on batten/ recess/cheses/buried in ground or drawn in conduit/pipe or any other indicated place for loop earthing etc as required for 32 x 6 mm GI strip and removal of old defective earthing strip. (b) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional.
RELATED TO SCH 'A' PART-IX, LIGHTNING PROTECTION Rectifcation of defective items of works as listed below including material & labour related to Test point terminal block fixed vide Srl Item No 04 of Sch 'A' Part-IX complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Fixing of existing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including new 3 nos. 8mm dia 25mm long hex. head screw properly (b) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional.
RELATED TO SCH 'A' PART-X, AIR CONDITIONING Rectifcation of defective items of works as listed below including material & labour related to existing floor mounted, air cooled, packaged type air conditioner unit, 22 TR capacity with scroll compressors based on R-407 C Refrigent Installed vide Srl Item No 01 of Sch 'A' Part-X complete all as specified and directed by Engr-in Charge. (a) Micro processor controlled floor mounted, Air Cooler Package Air Conditioner 22 TR Capacity with scroll compressor indoor/outdoor unit (Including MS Stand and vibrations pads) Refrigerant, piping, insulation etc complete all as per manufacturers specifications Model No DPA 2642R2 of Blue Star/ Samsumg/LG/Carrier- 03 Nos (Two working and 01 standby) (b) Supply and fix Pan Humidifier Kit 6 KW complete with humidistat and wiring-01 Set (c) Supply and fix strip heaters (To be fixed in duct with MS Frame, Insulator, for Humidity control in monsoon season and for heating during winter complete with humidistat and thermostat (02 Sets) and toggle switch for summer/monsoon more. Heater Capacity 3x12 KW (In two banks-01 Set) (d) Design supply and fix supply air duct above false ceiling and dully insulated with 6mm thick nitrile rubber, with supply air (Volume control) Grills all as specified-01 Set
(Item No 11.38 Contd-----) (e) Supply and fix return air grill in wall between package room and air condition space and on wall in other room all as specified (Winter air duct is not proposed)-01 Lot (f) Supply and fix volume control damper for each package-03 Nos (g) Supply and fix canvas correction with 8 " zip to connect package to duct - 03 Nos (h) Supply and fix digital tempreature and humidity meter -02 Set (j) LT Copper cable of suitable capacity from MCCB to package, strip heater, Humidifier with PVC conduit - 01 Lot (k) Supply and fix fress air cowl/grill with filter (20 micron)-01 Set (l) Supply and fix fusible link type fire damper-01 Set in AHU Room (m) Supply and fix acoustic lining (n) Supply and fix 200 Ltr 3 layer PVC Tank including GI Piping 15 mm dia upto Pan Humidifier (o) Supply and fix drainout pipe including valves The list of defective items/leftover item are covered as under and the quoted shall be inclusive of following:-. (i) Providing new MS Stand of iron 'L' shape channel of size 50 x 50 x 6 mm thick to be provided for 3 Nos Indoor and 06 Nos outdoor unit. (ii) Charging of refregerant gas R 407 C reqd. = 59.40 kg (iii) Wiring by 4.0 sqmm cu. Wire from pan humidifire to humidistat, 3/4 core cable of size 2.5 sqmm (approx length 10.0 m)
(Item No 11.38 Contd-----) (iv) Toggle switch for setting of monsoon / winter season with control wiring with humidistat and thermostat (02 Sets) needs to be provided for strip heaters. (a) Toggle switch -02 Nos (b) Wiring for toggle switch to panel, approx length 8.0 m (c) Humidistat and thermostat - 02 Sets (v) The damper’s to be provided in supply and return air gril :- (Reqd. Aluminium gril) (a) S & F Supply Air gril = 17 Nos and Return Air gril = 17 Nos, both are size is (500 x 500) mm, total = 34 Each Job (vi) The Duct over the package air conditioner are not is plumb. Moreover proper horizental supports and vertical supports in walls required to be provided (Approx length 10 mtrs). (vii) Return air grill in wall between package room and air condition space and on wall ( wall opening size is 2.8 mtr x 0.5 mtr) in other room (Winter air duct is not proposed)-01 Lot . Qty 1.40 Sqm (viii) Canvas correction with 8 " zip to connect package to duct - 03 Nos. (ix) Digital temperature and humidity meter - 02 Set (x) Fusible link type fire damper-01 Set in AHU Room (Size of fusible link type fire damper is (0.5m x 0.5m) (xi) PVC tank 3 layered ,200 ltr including connecting GI piping 15mm dia qty - 10 RM upto pan Humidifier. -01 No, (xii) Phase I and Phase II Summer, monsoon and winter test are to be carried out
(Item No 11.38 Contd-----) (i) Phase I , Phase II and Phase III i.e. Summer, monsoon and winter test are to be carried out by the Accepting officer or his authorised representative in presence of contractor. (a) Hot weather test to be conducted in summer month of May/June.The performance of plant as a whole will be recorded. (b) Monsoon test to be conducted during monsoon month Jul/Aug and performance recorded. (c) Winter test to be conducted during winter month of Dec/Jan and performance recorded. (ii) Each plant should run for continously 72 Hrs for each phase of testing. (iii) The contractor shall afford all facilities and make necessary arrangements for all the tests. (xiii) Any other minor / missing items required to complete the work to completely rectify the defect and make functional package type AC unit.
Rectifcation of defective items of works as listed below including material & labour related to existing underdeck insulation fixed vide Srl Item no 02 of Sch 'A' part-Xcomplete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Providing new M S rods 5 mm dia between purlins suitably for supporting the required thickness of insulation material beaneath the metal roof for various locations as directed by Engr-in-Charge (Total Qty 639.73 Kg) (b) Providing new GI wires 22 SWG for insulation supports (Total Qty 110.67 Kg) (c) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional.
Rectifcation of defective items of works as listed below including material & labour related to commercial Air curtain unit (size length 1830mm) installed vide Srl Item no 03 of Sch 'A' Part-X complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Supply, install, commissioning and testing of new commercial Air curtain unit (size length 1830mm) for pervention of dust and contitioned air losses for complete specification as specified in Srl Item no 03 of Sch 'A' Part-X.- Qty - 01 No. (b) Testing and commissioning only for existing Air curtain to be done (for two days) installed vide Srl Item no 03 of Sch 'A' Part-X - Qty - 04 Nos. (c) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional of Air curtain units.
RELATED TO SCH 'A' PART-XI, MISCELLANEOUS ITEMS Rectifcation of defective items of works as listed below including material & labour related to Louver for existing Heavy duty exhaust fan 450mm sweep complete all as specified and directed by Engr-in Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:-. (a) Providing new Louver for existing Heavy duty exhaust fan 450mm sweep - for 04 Nos of Fan installed at site (b) Any other minor / missing items required to complete the work to completely rectify the defect and make functional the exhaust fan
Rectification of defective items of works as listed below including material and material to related to existing Vertical TPN DB double door designed surface mounted, 415 volt 4/8 way way with copper bus bar suitable for mounting MCCB as incomer and TP MCB as outgoing all complete as directed.. The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Disconneting and removing of defective old TPN. (b) Refixing of TPN DB 4way/8way and the make good by plastering/painting work including matching with existing surface properly complete all as specified and directed by the Engr-in-Charge. (c) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional.
Rectification of defective items of works as listed below including material and labour related to existing Earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below ground level connected to GI Strip 32x6mm dia by means of bolt, nut, check nut and washer of galvanized iron or steel protected by galvanized iron pipe of 40 mm bore light grade, incl. funnel, 20 mm dia bore galvanized iron pipe light grade for watering, wire mesh, charcoal or coke and common salt in alternative layers all around the earth electrode compacted thickness 15 cm incl. excavation and earth work, PCC 1:3:6 type C2, CI pit cover, incl. disposal of surplus soil to a distance n. exc. 50 m, complete testing on completion, all complete as shown in electrical plate No 3, SSR Part-I all as specified. (Note:i)Charges for earth resistivity test deemed to be included in the quoted rate.ii)Earth resistance value shall be less than 1.0ohm). The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Providing new RCC cover for existing earth pit with GI strip of 32 x 6 mm -19 Nos of earthing installed at site (b) Testing of earthing - 19 Nos (c) Any other minor / missing items required to complete the work to completely rectify the defect and make functional the earthing.
Rectification of defective items of works as listed below including material and labour related to existing Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized steel wire 4mm dia earthing lead upto 7.5m from testing point fixed by means of galvanized iron or steel bolts nuts check nuts and washers, GI earth wire protected by 15mm bore light grade galvanized iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore medium grade galvanized iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness)all around the earth electrode with concrete earth pit in PCC (1 : 3 : 6) type C-1, cast iron frame, 50mm thick pre-cast RCC M-25 design mix cover slab size 450x450x50 mm reinforced with 8mm dia TMT bar 10cm C/C and suitable handle of 10mm dia round bar, including necessary excavation, earth work in soft/loose soil and disposal off spoil to a distance n.exc 50m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part I and as directed. The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) providing new RCC cover for existing earth pit with GI wire of 4 mm dia - 2 Nos of earthing (b) Testing of earthing = 02 Nos (c) Any other minor / missing items required to complete the work to completely rectify the defect and make functional the earthing.
Rectification of defective items of works as listed below including material and labour related to existing Chemical earthing with copper earth plate electrode of size 900 mm x 600 mm x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top as of the plate not less than 1.5 mtr below normal ground level, connected to copper earth lead strip of size 32 mm x 6 mm upto test point by means of nuts, bolts, check nuts and washers, earthing shall be filled with crystalline conductive material (CCM) both side the earth plate of 150 mm thick layer having non corrosive properties with back filling of soil after mixing of soil and enrichment chemical consisting of aluminum silicate (50 Kg min) all around the earth plate and CMM including earth work i.e excavation returning filling removal of excavated soil, providing PCC 1:3:6 type C-1 as per RCC cover (with 1:2:4 type B-1 reinforced with 6 mm dia MS bar @ 75 mm C/C both way and MS handle made out of MA bars) and 40 x 40 x 3 mm angle iron frame all as shown in SSR 2009 part-1 plate No 3 complete all as specified and directed. (Note:(i) Charges for earth resistivity test deemed to be included in the quoted rate and the work shall be carried out in presence of Engr-in-Charge.(ii) Earth resistance value shall be less than 1.0 Ohm) The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Providing new RCC cover for existing chemical earth pit with copper earth lead of size 32x6mm - 17 Nos of earthing provided at site (b) Testing of earthing = 17 Nos (c) Any other minor / missing items required to complete the work to completely rectify the defect and make functional the earthing.
Rectification of defective items of works as listed below including material and labour related to PCC foundation for existing LT Panel indoor type Automatic Power factor correction LT capacitor bank panel board ( MDXL/LTXL),dutly powder coated RAL 7035,capacity 340 KVAR having following accessories including control wiring with HR FRLS copper wire complete all as spcified and directed:- (i) Compact modular bolted design ,removable side and back panels with option of top and bottom cable entry. (ii) Capacitor installed in removable assemblies for ease of operation and maintenance. (iii) Incoming of APFC panel of MCCB TPN 400 Amps ,35 KV breaking capacity with high electolytic grade aluminium bus bar of suitable rating. (iv) MDXL/LTXL capacitor of 5KVAR - 02 No, 10 KVAR-03 Nos ,25 KVAR -02 Nos ,50 KVAR-01 Nos, 100 KVAR-02 Nos with heavy duty capcitor duty contractor with coil voltage 230 V,50 Hz & branch protection MCCBs of suitable rating to each capacitor. ( each capacitor bank equipped with discharge resister ) & 7% detuned harmonics filter reactor. (v) High performance microprocessor based 3-phase APFC relay 12 stage with auto/manual option. (vi) In built 3 phase power analyzer ,Amp meter ,volt meter and PF meter ( each have 1 no). (vii) Capacitor duty contractor with high thermal current carrying capacity and early make cotacts to reduce inrush current for enhancing life of capacitors. (viii) Induced air system provided with axial flow fan/centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front. The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Providing new PCC foundation to be provided for exiting cubicle type LT Panel board, Indoor/ outdoor type (b) Any other minor / missing items required to complete the work to completely rectify the defect and make the same functional.
Rectification of defective items of works as listed below including material and labour related to existing masonry valve pit chamber of size internally dimension 90 cm X 90 cm x 90 cm depth complete all as specified and directed by Engr-in-Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Painting to MS work on valve pit chambers to be provided with under coat of red oxide primer and two coat of synthetic enamel paint. (b) Any other minor / missing items required to complete the work to completely rectify the defect.
Rectification of defective items of works as listed below including material and labour related to diesel silent engine driven generating set 200 KVA (160KW), 415 V AC 3 ph 4 wire engine as per IS:10001/10002 and alternator set water/Air cooled ,vertical totally enclosed electric start, compression ignition ,4 stroke designed to run contineusly at 1500RPM conforming to IS:10001/10002,ISO-3046,BS-5514,DIN-6271 standard 50 Hz supply, (voltage regulation + 1 % of rated voltage from no load to full load with electronic regulator), 0.8 pf lagging complete with standard AMF control panel, sturdy welded channel iron common base frame both for prime mover and alternator, anti vibration pad and necessary RCC foundation etc all as specified by manufacturer and as specified in Annexure 'A' here-in-before. The list of defective items are covered as under and the quoted shall be inclusive of following:- (i) Servicing complete with replacement of fuel filter, oil filter, Coolent, Rubber hoses & engine oil etc. (ii) The complete control wiring needs to be checked including replacement of defective parts if any. (iii) The insulation provided on Exhaust/Silencer is worn out and hence requires repair’s / replacement. (iv)Replacing the battery 180 AH-2 Nos. (v) The AMF panel, the MCCB’s, relays & contactors etc need to be checked and made functional. (vi) Any other minor / missing items required to complete the work to completely rectify the defect and make the DG set serviceable .
Rectification of defective items of works as listed below including material and labour related to existing Special Power Supply equipment comprising of static voltage/frequency convertor suitable for 15KVA,3 phase 400 HZ capacity, UPS converter 10 KVA capacity 3 phase input & one phase output, Isolation transformer of 10 KVA, output 380 Volt, AC 50 HZ, 3 Phase & Rectifier 5.6 KW 28 V DC suitable for input voltage of 415+5 % V 3 Phase 50 HZ, 3 Phase complete all as specified and directed by Engr-in-Charge. The list of defective items are covered as under and the quoted shall be inclusive of following:- (1) The earth connection to be done done to the specified copper earth strip pertaining to SPS as most of SPS equipment have 3 Phase supply. (2) Testing on load for the all the equipment needs to be done in presence of user rep, company rep, contractor & Engineer in charge. (a) For 5.6 kw DC Rectifier. (i) 50 sq mm single core PVC insulated multistranded copper cable for incoming and out going supply (Positive and Negative). Total length = [(12 + 12) x 2] = 48 RM Grand total = 48 RM (50 sq mm) (b) (i) 25 sq mm single core PVC insulated multistranded copper cable for incoming and out going supply (for earthing). Total length = (12 + 12) = 24 RM (ii) 25 sq mm single core PVC insulated multistranded copper cable from DC Rectifire body earth point to existing earth erthing strip. Total = 12 RM. Grand total = (24 + 12) = 36 RM (25 sq mm)
(Item No 11.52 Contd-----) (c) Misc items (i.e. glands, PVC flexable pipe, socket/themble etc) (d) S& F of Battery of capacity 42 AH, 12 Volt of Make Exide Powersafe Plus, Black.- 60 Nos (e) Testing and commissioning of above items ser No. (a) to (b) complete incl instruments. (f) Any other minor / missing items required to complete the work to completely rectify the defect and make functional of the Special Power euipments as referred above.
Fixing only static voltage/frequency convertor suitable for 15KVA,3 phase 400 HZ capacity & Isolation transformer of 10 KVA, output 380 Volt, AC 50 HZ, 3 Phase complete all as specified and directed by Engr-in-Charge. Note:- static voltage/frequency convertor & Isolation transformer shall be issued under Sch 'B' at the rate specified therein. The list of works/ items are covered as under and the quoted shall be inclusive of following:- (a) For 15 KVA SFC. (i) 16 sq mm (for earthing), total requirement from Survo voltage stabilizer to 15 KVA SFC and 15 KVA SFC to TPN DB = (8 + 10) = 18 RM (ii) 16 sq mm single core PVC insulated multistranded copper cable (for body earthing 02 Nos), Total requirement from 15 KVA SFC body earth point to existing earth erthing strip. Total = (10 x 2) = 20 RM (iii) 16 sq mm single core PVC insulated multistranded copper cable (for SFC body earthing 02 Nos), Total requirement from battary rack body earth point to existing earth erthing strip. Total = (10.0 x 2)+2 = 22 RM.Grand total = (18 + 20 + 22) = 60 RM (16 sq mm) single core PVC insulated multistranded copper cable (b) For Isolation transformer and 10 KVA UPS. (i) 10 sq mm single core PVC insulated multistranded copper cable (for earthing), from 50 KVA Survo voltage stabilizer to 10 KVA Isolation Tr. and 10 KVA Isolation Tr. to 10 KVA UPS (provide only single run), = (16 + 03) = 19 RM (ii) 10 sq mm single core PVC insulated multistranded copper cable (for body earthing 02 Nos), from Isolation Tr. to existing earth erthing strip = (13 x 02) = 26 RM (iii) 10 sq mm (for body earthing 02 Nos), from 10 KVA UPS to existing earth erthing strip = (12 x 2) = 24 RM
(Item No 11.54 Contd-----) (iv) 10 sq mm single core PVC insulated multistranded copper cable (for body earthing 02 Nos), from battary rack body earth point to existing earth erthing strip = (12.0 x 2) = 24 RM (c) Testing and commissioning of above items ser No. (a) to (b) complete incl instruments. (d) Any other minor / missing items required to complete the work to completely make functional of the Special Power euipments as referred above.
Rectification of defective items of works as listed below including material and labour related to existing servo control voltage stabiliser 50 KVA , 415 V, 50 Hz copper wound for automatic controlling/regulating of voltage compromising of auto tranformer ,servo motor, intelligent micro controller based circuit ,naturally oil cooled indoor type and designed for input variation between 300V to 480 V with output voltage stabilised at 415 V with accuracy +/- 2.5% and rate of correction 8V per sec along with following features:- (a) Digital control module with advanced micro controller technology and self controllable design. (b) Display of input and output voltages, output load current and status indication with covering collar for ease of fitting and decent look. (c) Overload protection /over current protection with set and reset key and pass arrangement. (d) Protection against output feed back is disconnect or loose connected. (e) Low voltage and high voltage relay progarmmable at site. (f) Low voltage cut off in case input goes below range. (g) High voltage cut off in case input goes below range. (h) Low /high frequency protection. (j) Single phase prevention. (k) Earth fault protection. (l) Delay on circuit. (m) Alaram enunciator for audible indication of above fault. (n) Spike and surge protection. (o) Stabilizer by pass system. (p) Degree of protection IP 30. (q) No load losses less than 0.5%. (r) Efficiency – 99%. (s) Transformer oil as per IS-335. (t) Suitable for all power factor load. The list of defective items are covered as under and the quoted shall be inclusive of following:- (a) Oil leakage from servo stabilizer to be checked and rectified. (b) De-hydration of transformer oil and refilling with new oil to be done and maintenance of Dielectric strength of new oil as per relevant IS. (c) Any other minor / missing items required to complete the work to completely rectify the defect and make functional the servo stabilizer.
SCHEDULE 'A' PART -XII (SCHEDULE OF CREDIT) Note:- Note :- Amount of Rs 59,602.40 indicated in Tender as Schedule of Credit i.e. Schedule 'A' Part-XVIII shall be deducted from the total quoted amount of BOQ.
Golden Traders
M/s Dhani Enterprise
M/S Vimal Enterprise
M/s Capital Traders
M/S B.H. ENTERPRISE
Ms Sukumar Talukdar and Co.
M/S R G Construction
M P KHAITAN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .