Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹2.8 LAccepted-AOC | ₹2.8 L | L 1 | Accepted-AOC Awarded L 1 |
| 2 | L 2₹3.0 L+₹23,157.50 (8.41%)Rejected-Finance RATU RD PISKA MORE LAXMI NAGAR DISTT RANCHI JHARKHAND 834 005 | RANCHI | RANCHI | JHARKHAND | 834005 | ₹3.0 L+₹23,157.50 (8.41%) | L 2 | Rejected-Finance Quoted Higher Rate |
| 3 | L 3₹3.1 L+₹29,588.50 (10.7%)Rejected-Finance CENTRAL COALFIELDS LIMITED OFFICE OF THE PROJECT OFFICER E M DEPARTMENT SAUNDA D BARKA SAYAL AREA | BOKARO | JHARKHAND | 825102 | ₹3.1 L+₹29,588.50 (10.7%) | L 3 | Rejected-Finance Quoted Higher Rate |
| Sl No | Description | Qty | Unit | Munda Construction & Services L1 | R AND S ELECTRICALS L2 | coalfields engineering works L3 |
|---|---|---|---|---|---|---|
| 1.00 | Part (A) Andrew Yule make VCB 3.3 KV, 630Amp sl no-2728 Supply & Fixing of Current transformer, CTR 400/200/5+5,3.3KV grade, epoxy resin cast type | 2 | No | 29,600 ₹59,200 Lowest | 32,000 ₹64,000 | 33,000 ₹66,000 |
| 2.00 | Supply & Fixing of Rectifire Unit with 40AMP current capacity and 110 V DC voltage grade | 1 | No | 11,000 ₹11,000 Lowest | 12,000 ₹12,000 | 12,500 ₹12,500 |
| 3.00 | Supply & Fixing of P.T Fuse 3.3 kV /3Amps rated for PT | 3 | No | 4,150 ₹12,450 Lowest | 4,300 ₹12,900 | 4,400 ₹13,200 |
| 4.00 | Supply & Fixing of Auxillary contact 110V | 1 | No | 14,000 ₹14,000 Lowest | 15,500 ₹15,500 | 15,500 ₹15,500 |
| 5.00 | Supply & Fixing of Series trip Mechanism | 1 | No | 14,000 ₹14,000 Lowest | 14,750 ₹14,750 | 15,500 ₹15,500 |
| 6.00 | Supply & Fixing of Selector Switch 16Amp rated | 1 | No | 2,130 ₹2,130 Lowest | 2,200 ₹2,200 | 2,250 ₹2,250 |
| 7.00 | Supply & Fixing of AMP Meter 0-600 A range, 110V, 4" Sq.mm.size | 1 | No | 1,950 ₹1,950 Lowest | 2,000 ₹2,000 | 2,100 ₹2,100 |
| 8.00 | Supply & Fixing of Volt Meter, 0-15KV range, 110V, 4"Sq, mm. size | 1 | No | 2,000 ₹2,000 Lowest | 2,100 ₹2,100 | 2,100 ₹2,100 |
| 9.00 | Supply & Fixing of Support Insulator dia 75mm length 90mm | 2 | No | 1,050 ₹2,100 Lowest | 1,100 ₹2,200 | 1,150 ₹2,300 |
| 10.00 | Supply & Fixing of Shunt Trip Coil 110V AC/DC grade | 1 | No | 6,300 ₹6,300 Lowest | 6,400 ₹6,400 | 6,500 ₹6,500 |
Tender Value
₹2.8 L
EMD Value
₹3,400
Closing Date
16 Jan 2026, 3:00 pmClosed
PE (EnM)
PEOCP
Repairing and overhauling of Andrew Yule make VCB 3.3 KV, 630 Amp sl no-2728 installed at Parej substation secondary control of 3 MVA Power Transformer and Sait Teknik pvt ltd make 3.3KV, 360KW HT Starter sl no-SAHD2732 at PE OCP under Hzb. Area.
2026_CCL_350555_1
PO/PECP/EnM/Tender/25-26/24
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
PEOCP
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,400
15 Jun 2026
5 Jan 2026
17 Jan 2026
5 Jan 2026
16 Jan 2026
5 Jan 2026
5 Jan 2026 - 10 Jan 2026
Part (A) Andrew Yule make VCB 3.3 KV, 630Amp sl no-2728 Supply & Fixing of Current transformer, CTR 400/200/5+5,3.3KV grade, epoxy resin cast type
Supply & Fixing of Rectifire Unit with 40AMP current capacity and 110 V DC voltage grade
Supply & Fixing of P.T Fuse 3.3 kV /3Amps rated for PT
Supply & Fixing of Auxillary contact 110V
Supply & Fixing of Series trip Mechanism
Supply & Fixing of AMP Meter 0-600 A range, 110V, 4" Sq.mm.size
Supply & Fixing of Volt Meter, 0-15KV range, 110V, 4"Sq, mm. size
Supply & Fixing of Support Insulator dia 75mm length 90mm
Supply & Fixing of Shunt Trip Coil 110V AC/DC grade
Supply & Fixing of Push Button Mushroom type 1NO+1NC
Supply & Fixing of Indicating lamp 110V , AC/DC rated for each phase (R/Y/B)
Wiring with ferruls & Lugs as required materials
Part (B) Sait Teknik pvt ltd make 3.3KV, 360KW HT Starter sl no-SAHD2732 Supply & Fixing of RESIN CAST MOULDED CT FOR O L RELAY
Supply & Fixing of 3 POLE MAGNETIC O L RELAY
Supply & Fixing of CT OPERATED THERMAL OVERLOAD RELAY
Supply & Fixing of SINGLE PHASING PREVENTOR WITH MODULE
Supply & Fixing of Isolator Fixed Contact set
Supply & Fixing of Isolator Moving Contact set
Supply & Fixing of VACUUM CONTACTOR RECTIFIER BRIDGE
Supply & Fixing of Aux Contactor 110V AC 3 NO plus 1 NC
Supply & Fixing of HT Control Fuse 3 point 3 KV 2 A
Supply & Fixing of DMC moulded 3 point 3 KV insulator for power
Supply & Fixing of Indicating lamp 110V , AC/DC rated for each phase (R/Y/B)
Supply & Fixing of AMP Meter 0-200 A range, 110V, 4" Sq.mm.size
Supply & Fixing of Volt Meter, 0-15KV range, 110V, 4"Sq, mm. size
Supply & Fixing of AUXILIARY CONTACTOR 4 NO plus 4 NC 110V
Wiring with ferruls & Lugs as required
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.51 MB
BOQ_363307.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .