| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹45.4 L+₹3.7 L (8.84%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
15 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (A) Central Jodhpur
GE (A) Central Multan Line Army Area Jodhpur
SPL REPAIR TO BUILD NO T117 AND T 120 OF 408 SATA REGT WKSP EME TYPE P AT ARMY AREA JODHPUR (9065/E8)
2021_MES_495953_1
GE/J/A- OF 2021-22 (9065/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (A) Central Multan Line Army Area Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (A) Central Jodhpur
₹56,000
1 Feb 2022
18 Dec 2021
17 Jan 2022
18 Dec 2021
15 Jan 2022
1 Jan 2022
60 days
Amount
B/R WORK Demolition of cement concrete(unreinforced) in ground floors and pavings below or above ground level n exc 15 cm thickness, complete all as directed.
Dismantling of stone slabs in roofs, suspended floors chajjas, landings, etc any thickness, jointed in any mortar, complete all as directed.
Dismantling stone slabs of any description or thickness in floors etc, complete all as directed.
Demolition of reinforced cement concrete such as roof, floor slab, colums ,beam stair case lording chajja and similar surpuled work and (removing of demolished material outside MD land), complete all as directed
Demolition of stone boulder masonry built in cement mortar including all quoins, pillars etc and removal of unservicable matual debris rubbish out side No law, complete all as directed.
Racking out joints/pointing to square rubble masonry Jodhpur type regular coursed built in cement mortar in walls not less than 12mm deep, washing the joint rewoving rubbish of the premises and keeping the surface to pointed or plastered, wef for two days pewor to repointed or plastereing, complete all as specified and as directed.
M&L for squared rubble walling jodhpur type, regular coursed,well bonded bedded and solidly hearted, built in cement mortar 1:6, complete all as specified and as directed.
Extra over stone walling for hammer dressing to face stones with max depression on face from a straight edge not exceeding 20mm and dressing of face beds and joits for squared rubble walling regular coursed Jodhpur type, complete all as specified and as directed.
M&L for keyed pointing to squared rubble stone masonary Jodhpur type regular coursed or uncoursed in CM 1:3, complete all as specified and as directed.
M&L for two coats of cement base paint over a coat of primer on new plastered/pointed surfaces of walls, including preparation of surfaces, complete all as specified and as directed.
M&L for RCC M-25 Mix(using 20mm graded Crushed stone aggregates) as in beams, lintel, lintel bards over 1.5m clear span, complete all as specified and as directed.
M&L for RCC M-25 Mix(using 20mm graded crushed stone aggregates as in RCC slabs,Staircases, chhajja/cooking plateform etc, complete all as specified and as directed.
M&L for Form work to soffit of suspended RCC slabs, landing, shelves, canopy etc not exc 200mm thick for flat fair finished surfaces, complete all as specified and as directed.
M&L for Form work to sides and soffits of floor or roof RCC beam sides of lintel beam flat fair finish surfaces, complete all as specified and as directed.
M&L for Form work to edges of concrete flats,floor and roofs and sides of RCC/PCC bands in walls,horizontal or sloping and similar work exc 10cm but n.exc 20cm wide for flat fair finished surfaces, complete all as specified and as directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
TMT bars 6 to 8mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends binding with MS wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
Ditto but bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
M & L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) and as in floors and made surface rough to receive floor finish, complete all as specified and as directed.
M&L for joint free Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:4, complete all as specified and as directed. Make: Kajaria/ Somany/ Orientbell.
M&L joint free Coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces / skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering as in backing coat in CM 1:4, complete all as specified and as directed. Make: Kajaria/ Somany/ Orientbell.
M&L for mirror polished machine cut kota stone slab flooring 20-25mm thick over and including 15mm thick cement screed base CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, and removing the rubbish of the MP land etc., complete all as directed.
M&L for 15 mm thick plastering on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished fair and even and smooth without using extra cement in CM 1:6, complete all as specified and as directed.
M&L for preparation of news plastered surface of wall and applying two coats of distemper oil emulsion over a coat of wall care putty 3mm thick, complete all as specified and as directed.
M&L for 5mm thick plastering in CM 1:3 on ceiling surfaces finished surfaces even and smooth without using extra cement, complete all as specified and as directed.
M&L for preparation of newly plastered ceiling surfaces and applying three coats of white wash, complete all as specified and as directed.
Taking down chowkats or frames with shutter (without taking off shutters from the frame) exceeding 1.5 Sqm each but not exceeding 4.00 sqm and removing from site, complete all as specified and as directed.
M&L for powder coated aluminium framed doors/ partitions with shutters(Double/Single leaf) with one or more rebates,aluminium sections of approved make,including jointing cleat for fixing,handles,glazing/panelling boards etc, complete all as specified and as directed. NOTE:For spring/door closer,glazing and panelling shall be measured and paid separately)
Taking down windows of area n.exc 1.5sqm with frames without taking off shutters, complete all as directed by Engg-in-Charge.
Factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chrome primer with cooler opening, complete all as specified and as directed.
Factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and with one shop coat of zinc chrome primer with cooler opening, complete all as specified and as directed.
S&F framed work as in grill guard bars and welded to window frames, complete all as specified and as directed.
S&F 3 mm thick pinheaded sheet glass panes of size not exc 0.5 Sqm fixed with oil putty, complete all as specified and as directed.
M&L 12mm thick prelaminated particle board, (ISI Marked) interior grade, prelaminated both side with decorative choice lamination, fixed with screws to aluminium frame work, complete all as specified and as directed.
S&F galvanised wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40 mm fixed to anodised aluminium framework of windows/vents, complete all as specified and as directed.
S&F door closer hydraulically regulated, designation No 3, aluminium (die cast ) body, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed including taking down old one, complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, of 150 mm with rubber shoe and fixed in floor, complete all as specified and as directed.
S&F Stainless steel butt hinges, medium weight of 100mm long size, complete all as specified and as directed.
S&F extruded aluminium alloy handles, 75mm long size, fabricated type, anodised, complete all as specified and as directed.
S&F mild steel framed work as in brackets for cooler stands using MS angle iron nuts & bolts / framed pillars/posts refteres etc complete incl necessary drilling fixing with fasteners etc, complete all as specified and as directed.
Supply and fixing in repairs decorative type curtain rod stainless steel finish of pipe 22 to 25 mm dia with best quality knob metal as per sample kept in GE's office, complete all as specified and as directed.
Supply and fixing in repair purpose made brackets trade pattern for decorative type curtain rods suitable for holding 22 to 25 mm dia as per sample as in repairs kept in GE's office, complete all as specified and as directed.
M & L Preparation of surface and applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer, complete all as specified and as directed.
M&L for providing Gypsum board 80 mm thick and fixedto wall and floor or as in partitions, complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, boards/slabs/blankets, any thickness, including cover fillets, complete all as directed.
S&F anodised aluminium snap grid of approved thickness frame work of size 605x605 mm for false ceiling, complete all as specified and as directed.
S&F hangers 6mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long, complete all as specified and as directed.
M&L for providing and fixing gypsum board 12 mm thick in ceiling fixed with screws as per manufacturers instructions, complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40 mm thick graded course aggregate) as in plinth protection, complete all as specified and as directed.
M&L for Water proofing treatment for roofs in the following stages :- (a) 10mm thick plaster in cement mortar 1:3 with water proofing compound complete. (b) FIRST COURSE : One coat of bitumen primer T-10/polymerised confirming to IS-3384 @ 0.30 Ltr/Sqm. (c) SECOND COURSE : One coat of bonding material using blown type bitumen confirming to IS-702 grade 85/25 @ 1.20 kg/sqm. (d) THIRD COURSE : A layer of APP modified polymeric membrane centre core of 100 micron HMHPDE, outer film 20 micron each, thickness 2.00 mm having weight 3.0 Kg/Sqm. (e) FOURTH COURSE : a coat of bonding material using blown type bitumen confirming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm. (f) FIFTH COURSE : 40 mm thick PCC (1:2:4) padding, well compacted using 20 mm graded aggregate of curshed stone with V-shaped groove of 10 mm depth filling with mastic bitumen. Size of PCC panel with grooves shall not be exceeding 0.40 Sqm.
Supply only integral water proofing compound ((ISI Marked)), complete all as specified and as directed.
M&L for Endura cool roof SRI tiles of size 300x300mm, 10mm thick of, laid over 15mm thick bedding in cement mortar (1:4), joints grouted and flush pointed in cement mortar (1:3) mixed with 5% crude oil by weight of cement, complete all as specified and as directed.
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as directed.
Dismantling of wrought iron or mild steel work of any description, complete all as directed.
Excavation in post holes (or similar holes) each n exc 0.5 cu.m in any type of and soil getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete for post, complete all as specified and as directed.
S&F Structural Steel work (Fabrcation, erection and fixing) in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240, complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of a colour having tensile strength of 550Mpa as in roof covering, chajjas fixed with self tapping screws, complete all as specified and as directed.
M&L for 75 mm thick Cement concrete 1:4:8 type D - 2, (using 40 mm graded aggregate) as in sub base to floors incl well compacting & laid to levels, complete all as specified and as directed.
S&F machine pressed precast cement concrete interlocking paver blocks 60mm thick of any shape and size confirming to IS-1565/-2006 of M-35 Grade with 6mm top layers of ante abrasive rubberised material laid over and including 25mm thick sand cushion, complete all as specified and as directed. (The interlocking joints shall be filled with fine sand)
S&F machine made precast cement concrete Kerb stone blocks of approved shape size using Cement concrete 1:3:6 type C1 (using 20mm stone agg) laid alongside paths /hardstanding jointed & pointed in CM 1:4, complete all as specified and as directed by Engr-in-Charge
Excavation in trenches n.exc 1.5 mtr wide and n. exc 1.5 mtr in depth; for foundation etc, or for shafts, wells,cesspits, manholes, Pierholes etc n. exc 10 sqm on plan and n. exc 1.5 mtr in depth and getting out in hard/dence soil, complete all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n. exc 1.5 mtr depth for foundation, shafts, wells,cesspits, manholes, Pierholes etc n. exc 10 sqm on plan and n. exc 1.5 mtr in depth and getting out hard/rock, complete all as specified and as directed.
All as per item No. 01 above but exc 1.5 mtr and n.exc 3.0 mtr deep, complete all as specified and as directed.
Demolition and breaking up RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches 150mm bore of pipe, complete all as directed.
Demolition and breaking up RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches 200mm bore of pipe, complete all as directed.
Demolition and breaking up RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches 300mm bore of pipe, complete all as directed.
Demolition and breaking up RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches 450 mm bore of pipe, complete all as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removal of debirs to a distance n exc 50mtrs and depositing where directed, complete all as directed by Engr-in-Charge.
Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water etc., complete all as directed.
M&L for plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in surface channel or benching including finishing the top of benching even and smooth using extra cement (Forming fair finished channel shall be measured separately), complete all as specified and as directed.
Supply and laying and testing of RCC drain pipe 150 mm dia class NP-2 laid and jointed complete with collars, complete all as specified and as directed.
Supply and laying and testing of RCC drain pipe 200 mm dia class NP-2 laid and jointed complete with collars, complete all as specified and as directed.
Supply and laying and testing of RCC drain pipe 300 mm dia class NP-2 laid and jointed complete with collars, complete all as specified and as directed.
Supply and laying and testing of RCC drain pipe 450 mm dia class NP-2 laid and jointed complete with collars, complete all as specified and as directed.
All as per item No. 07 above but except stone, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channel and drains, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, kerbs etc, complete all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on stone masonry surface (Internally) of walls mixed with WPC, as per manufacturer’s instruction and finished the surface even and smooth without using extra cement, complete all as specified and as directed. (WPC shall be measured and paid separately)
Returning , filling in soil (any type) incl spreading levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and as directed.
Removing surplus excavated material exc250m but n.exc 500m where directed at a level not exceeding 1.5 Mtr above the starting point, complete all as specified and as directed.
Supply and Fix cast iron foot steps, n. exc 5 Kg each in manholes, complete all as specified and as directed.
Cutting in to existing manhole for connecting new drains and making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finish and reforming benching as asked for following dia of pipe, complete all as specified and as directed. (a ) 200 mm dia
All as per item No. 85 above but 300 mm dia
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 110mm bore, complete all as directed.
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 75mm bore, complete all as directed.
S&F 100mm dia CI spun cast iron pipe jointed with cement joint and fixed to walls including cutting of holes wherever required, complete all as specified and as directed.
S&F of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in wall and fixed with MS clamp, complete all as specified and as directed by engineer in charge.
S&F PVC SWR pipes single socketed in any length with rubber rings joints laid in trenches or in floors 110mm, complete all as specified and as directed.
S&F 75mm dia CI spun cast iron pipe jointed with cement joint and fixed to walls including cutting of holes wherever required, complete all as specified and as directed.
S&F PVC SWR pipes single socketd in any length with rubber rings joints laid in trenches or in floors 75 mm, complete all as specified and as directed.
All as per item No. 93 above but fixed in wall, complete all as specified and as directed.
S&F PVC (SWR) branch pieces single socketed Y equal or unequal 110mm, complete all as specified and as directed.
S&F PVC (SWR) bends any radius 110mm, complete all as specified and as directed.
S&F PVC (SWR) bends 75mm dia with oval acess door, complete all as specified and as directed.
S&F PVC SWR vent cowl 110mm, complete all as specified and as directed.
S&F PVC SWR vent cowl 75mm, complete all as specified and as directed.
S&F 75 mm PVC SWR junction (T) with acces door equal or unequal, complete all as specified and as directed.
S&F 110mm PVC SWR junction (T) with acces door equal or unequal complete all as specified, complete all as specified and as directed.
S&F 100mm dia CI bends including cutting of holes, complete all as specified and as directed.
S&F 100mm dia CI connector of length 30 cms including cutting of holes with lead joints, complete all as specified and as directed.
S&F CI "single branch piece" 100mm dia, complete all as specified and as directed.
S&F CI "double branch piece" 100mm dia, complete all as specified and as directed.
S&F 75mm dia CI bends including cutting of holes, complete all as specified and as directed.
S&F CI single branch piece 75mm dia, complete all as specified and as directed.
S&F CI double branch piece 75 mm dia, complete all as specified and as directed.
M &L for cutting to Bituminious road for laying of RCC hume pipe & making good as per road, complete all as specified and as directed. of Engr-in-Charge.
Cutting and grubbing of bushes grass and tree surrounding sewage line and levelling of ground around the sewage line, finish the surface and removing the waste material to distance exc. 50m and n exc. 250m and clearing the site, complete all as specified and as directed.
Cleaning/removal of sewage block in the existing line in any depth from WC to first manholes or gully trap to manholes including cleaning of WC and testing of pipe by pouring water 100mm SGSW/RCC/CI pipe for ground floor qtr including removal of waste out side defence land, complete all as specified and as directed.
Cleaning/removal of sewage block in the existing line in any depth from WC to first manholes or gully trap to manholes including cleaning of WC and testing of pipe by pouring water 100mm SGSW/RCC/CI pipe for first floor qtr including removal of waste sludge out side defence land, complete all as specified and as directed.
Cleaning/removal of blockage in the existing line in any depth and bathroom to first manholes or gully trap to manholes including cleaning of bathroom and WHB trap and testing of pipe by pouring water manhole 75mm SGSW/RCC/CI pipe for ground floor qtr including removal of waste sludge out side defence land, complete all as specified and as directed.
Cleaning/removal of blockage in the existing line in any depth and bathroom to first manholes or gully trap to manholes including cleaning of bathroom and WHB trap and testing of pipe by pouring water manhole 75mm SGSW/RCC/CI pipe for first floor qtr including removal of waste sludge out side defence land, complete all as specified and as directed.
Cleaning/removal of blockage in the existing line in any depth and kitchen to first manholes or gully trap to manholes including including cleaning of kitchen trap and testing of pipe by pouring water 75mm SGSW/RCC/CI pipe for ground floor qtr including removal of waste sludge out side defence land, complete all as specified and as directed.
Cleaning/removal of blockage in the existing line in any depth and kitchen to first manholes or gully trap to manholes including including cleaning of kitchen trap and testing of pipe by pouring water 75mm SGSW/RCC/CI pipe for first floor qtr including removal of waste sludge out side defence land, complete all as specified and as directed.
Cutting of berms as per existing, dressing around and making good, complete all as specified and as directed by Engr-in-Charge.
Cleaning of manholes complete of anysize and at any location incl taking out sludge and other material deposited in manhole and its disposal sludge outside defence land, complete all as specified and as directed by Engr-in-Charge for depth of manholes as given below:- (a) Depth of manhole n exc 1.00 M
All as per item No. 118 above but Depth of manhole exc 1.00 M and n exc 2.00 M, complete all as specified and as directed.
All as per item No. 118 above but Depth of manhole exc 2.00 M, complete all as specified and as directed.
S&F 75mm thick Jodhpur type stone slab not exc 2m in length dressed all face & along exposed edged size faced both sided as in drain cover, complete all as specified and as directed.
Pumping out water inflow caused by spring or tidal or river seepage, broken water mains or drains and the like with pumping set of 5 HP to 9 HP including POL/power consumption & operator maint etc., complete all as specified and as directed. Note : (i) This item shall be operated only when specifically ordered by Engr-in-charge/GE.
M&L Rendering 10 mm thick CM (1:3) on concrete surfaces on ceiling / facia /RCC Chhaja & finished even & smooth complete etc., complete all as specified and as directed.
M&L for 10mm thick rendering in CM 1:4 over stone masonary surfaces incl finishing the surface fair & rough to receive tiling etc, complete all as specified and as directed.
Material and Labour glazed coloured ceramic tiles 350 x450 x 7 mm /350x250x7mm thick as in dado (vertical surfaces) set and jointed with neat cement slurry and pointed with white cement , complete all as specified and as directed. Make: Kajaria/ Orient bell/ Somany
M&L preperartion of newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed.
M&L preperartion of newly plastered surfaces of wall and applying two coats of OBD, complete all as specified and as directed.
M&L preperartion of newly plastered surfaces of ceilling and applying three coats of white wash, complete all as specified and as directed.
Demolition of cement concrete (un -reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)and removing rubbish material outside defence land, complete all as directed.
Material and Labour non skid coloured ceramic tiles 300 x 300 x 6 mm in floors set and jonted in neat cement slurry and pointed in coloured / white cement to match in and including 15mm thick cement mortar screed in CM 1:6, complete all as specified and as directed. Make: Kajaria/ Orient bell/ Somany
M&L 75 mm thick PCC (1:3:6) type C1 (using 20mm gradde crushed aggregate) as in plinth protection, complete all as specified and as directed.
Taking down or up steel / PVC tubing and connection including cleaning for refixing or removal to store, complete all as specified and as directed. (a) 20 mm dia
All as per item No. 132 above but 15 mm dia, complete all as specified and as directed.
S&F of GI water tubing, medium grade, galvanized, with all fittings fixed to wall, complete all as specified and as directed. (a) 20 mm dia
All as per item No. 134 above but 15 mm dia including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc, complete all as specified and as directed.
E/M WORK Taking down carefully copper/aluminium point wiring for light, fan, bell socket power slocket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose etc , complete all as directed.
Point wiring complete with 1.5 sqmm, single core, multi stranded, copper conductor, PVC (FRLS), insulated, unsheathed cable, confirming to IS-694, 1100 volts grade, (ISI Marked) (class V conductor), in and including PVC concealed conduit (MMS), (ISI Marked) not less than 20mm, with accessories fixed on surface of wall/roof/ceiling etc and including sunken pressed steel terminal boxes in wall but including 3mm thick plastic laminated sheet top cover ((ISI Marked) hylem sheet Make Anchor and 1.50 sqmm PVC insulated unsheathed stranded copper conductor for common earth and connecting to earth dolly material and labour, complete all as specified and as directed. :- (a) One light point controlled by one, one way switch
All as per item No. 137 above but One fan /Exhaust fan, point controlled by one way switch, complete all as specified and as directed.
All as per item No. 137 above butOne socket outlet 3 pin 6 Amps on same board, complete all as specified and as directed.
All as per item No. 137 above but One socket outlet 3 pin 6 Amp on independent board, complete all as specified and as directed.
All as per item No. 137 above but with 2.5 Sq mm single core multistanded copper conductor cable for 3 pin 16 Amp socket outlet on independent board, complete all as specified and as directed.
S&F switch flush type single pole one way 6 Amp (ISI Marked), complete all as specified and as directed.
S&F switch flush type single pole one way 16 Amp (ISI Marked), complete all as specified and as directed.
S&F socket out let , 5 pin , 6 Amp FT, complete all as specified and as directed, complete all as specified and as directed.
S&F socket out let , 6 pin ,16 Amp FT. (ISI Marked), complete all as specified and as directed.
supply and fix socketed stepped type electonic fan regulator flush type (ISI Marked), complete all as specified and as directed.
S&F Ceiling rose, 3 terminal/PVC/ polycarbonate, isolated body, complete all as specified and as directed.
"Fixing only" LED light fitting 1 X 10/18/20/22 watt (4/2 feet) complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and as directed. Items to issued under Sch 'B'
"Fixing only" Bldg security LED Light Luminaire of 25/45 Watts any make any size including GI pipe 40 mm bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable, complete all as specified and as directed. Note: Bldg Secuity light fitting to be issued under Sch B.
Supply & Fixing and hanging to be ceiling fan/ Exhaust fan and connectiong up includisng provison of cable from ceiling rose or connector to fan, complete all as specified and as directed.
M&L in repairs sub main wiring with 6.00 Sq mm single core multistrandred copper conductor PVC insulated FRLS and unsheathed cable passing through PVC concealed conduit and making good the distrurbed surface of wall inc 6 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire, complete all as specified and as directed. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm shall be measured as unit length.
S&F Prewired distribution board in sheet metal with 200 Amps rated copper bus bar Confirming to relevant IS.SPN 8 way, complete all as specified and as directed. Make;-Legrand/ABB/Schneider Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface.
S&F single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amp ‘C’ curve type, 230 volts, 10 KA as per Cat part No. 507811, complete all as specified and as directed. Make- Legrand/ABB/Schneider
S&F Prewired distribution board in sheet metal Prewired when MCB to be used with 200 Amps rated copper bus bar Confirming to relevant IS TPN 4 way, complete all as specified and as directed. Make;-Legrand/ABB/Schneider Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface.
S&F MCB Single pole 5 to 30 Amp, 10 kA, (ISI Marked), complete all as specified and as directed.
S&F MCB Double pole 40 Amp, 100mA, (ISI Marked), complete all as specified and as directed.
S&F MCB SPN 63 Amp, 10 kA, (ISI Marked), complete all as specified and as directed.
S&F MCCB T PN 63 Amp, 10 kA, (ISI Marked).
Earthing complete with galvanised steel earth plate electrode 60 x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate no. 3 connected to Earthing test point all as specified or indicated including testing on completion Note : (i) Rates are deemed to be included for necessry earth work ,PCC pit , RCC cover etc complete. (ii) Earth lead shall be up to 7.5 Mtr and rates are deemed to be included for GI pipe 15mm Light grade upto 7.5 mtrs for protection of earth wire 4.0 mm dia.
Supply and laying or fixing or passing through pipe 1100volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire and overall PVC Sheathed 16 sq 4 core in service connection, complete all as specified and as directed. Make polycab/Havells/Finolex
Note:- 1. All items in BOQ are for"Materials and labour (M&L) /Supply and fix (S&F)" and to be executed in "Repairs " unless otherwise specifically mentioned as "Supply only" or "fixing only" or "Supply and Laying only" in BOQ. Bidders are requested to quote their rates accordingly. 2. The contract amount shall be arrived at after duducting amount of Schedule of Credit from the Total quoted amount.
Nikhat nirman
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .