| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹6.5 L+₹1.4 L (28.5%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹7.0 L+₹1.9 L (38.2%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹12.2 L+₹7.1 L (140.6%)Rejected-AOC 589 BC BAZAR AMBALA CANTT AMBALA | L4 | Rejected-AOC Not Lowest |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
3 Jul 2024, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LAB JODHPUR
REPAIR/MAINT/REPLACEMENT OF ALL TYPES UNSERVICEABLE DBs, PANEL BOARD, SUB MAIN WIRING AND EARTHING ETC IN MD ACCN IN DEFENCE LAB JODHPUR
2024_MES_658763_1
8591/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹14,000
Yes
24 Sept 2024
10 Jun 2024
5 Jul 2024
10 Jun 2024
3 Jul 2024
19 Jun 2024
11 Jun 2024 - 18 Jun 2024
Amount
M&L for load balancing of Three phase and Neutral DB of qtr/building of any type/size and capacity complete including dis-connecting of existing cables/wires and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium /Copper Thimbles and wire connector of any size and capacity for each wire/cables all as per required on ground complete all as specified and directed by Engr-in-charge. Note : (i) Necessary equipment and safety measures reqd for load balancing will be arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper thimbles, connector for wire, earth and neutral link, insulator, any type of screws, copper/aluminium bus bar of any size as per site requirement change under the job deemed to be included in the quoted rate by contractor. (iii) MCCB/MCB any type required for replacement shall be measured and paid separately in relevant item under Schedule.
M&L for load balancing of Single phase DB of qtr/bldg of any type/size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium /Copper Thimbles and wire connector of any size and capacity for each wire/cables all as per required on ground complete all as specified and directed by Engr-in-charge. Note : (i) Necessary eqpt and safety measures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium / Copper thimbles, connector for wire, earth and neutral link, insulator, any type of screws, copper/aluminium bus bar of any size as per site reqmt change under the job deemed to be included in the quoted rate. (iii) MCB required for replacement shall be measured and paid separately in relevant item under Schedule.
Supply and fix in replacement of unsv electronic meters temper proof LCD display with polycarbonate cover single phase 230 V, 10-60 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Make : HPL/Bentex/Jaipuria or equivalent ISI Marked.
Supply and fix in repplacement of unsv electronic meters temper proof LCD display with polycarbonate cover three phase 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Make : HPL/Bentex/Jaipuria or equivalent ISI Marked.
M&L for checking of earth resistance test of bldg connected with panel / distribution box by disconnecting of earth strip/ wire with the help of earth resistance tester complete and maintained records in register as per sample given all as specified and as directed by Engr-in-Charge. Note (i) Necessary eqpt , safety measures and stationary reqd for earth resistance test arranged by the contractor without any extra cost.
Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 08 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete, including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. Make : LEGRAND/L&T/C&S/SCHIENDER
Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 12 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete, including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. Make : LEGRAND/L&T/C&S/SCHIENDER
Supply, fixing, connecting & testing sheet metal enclosures double door, TPN, 4 way 415 V ,DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 250 Amps rating with IP-42 protection complete, including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. Make : LEGRAND/L&T/C&S/SCHIENDER
Supply, fixing, connecting & testing sheet metal enclosures double door, VTPN, 4 way 415 V ,DBs for using MCBs / MCB/FP isolators with having aluminium bus bars suitable for 350 Amps rating with IP-42 protection complete, including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. Make : LEGRAND/L&T/C&S/SCHIENDER
S&F MCB 240 volts SPN 40-63 amp 10KA breaking, capacity, ISI marked, including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Make : LEGRAND/L&T/C&S/SCHIENDER.
S&F MCB 240 volts SPN 32 amp 10KA breaking, capacity, ISI marked,including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Make : LEGRAND/L&T/C&S/SCHIENDER.
S&F MCB 240 volts SPN 16-25 amp 10KA breaking, capacity, ISI marked, including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Make : LEGRAND/L&T/C&S/SCHIENDER.
S&F MCB 240 volts SP 6- 32 amp 10 KA breaking capacity ISI marked, including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Make : LEGRAND/L&T/C&S/SCHIENDER.
S&F MCB TPN 415 volts 63 amp 4 pole 16 KA breaking capacity, ISI marked including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Make : LEGRAND /L&T/ C&S/ SCHIENDER.
S&F MCCB 415 volts 4 pole 100 amp 16 KA breaking capacity, ISI marked including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Make : LEGRAND /L&T/C&S/ SCHIENDER
S&F MCB Blanking plates suitable for MCB DB's including taking down old unsv existing complete all as specified and directed by engineer-in-charge.
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps including taking down old unsv existing complete all as specified and directed by engineer-in-charge. Make : LEGRAND/L&T/C&S/SCHIENDER
M&L for replacement of unsv sub main/point wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 1.5 Sqmm and one run of 1.5 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit/concealed of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable and with one run of earth wire and PVC conduit shall be measured & paid for as one length. Make of wire : Polycab/Anchor/Havells/Grandlay
M&L for replacement of unsv sub main/point wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 2.5 Sqmm and one run of 2.5 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit/concealed of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable and with one run of earth wire and PVC conduit shall be measured & paid for as one length. Make of wire : Polycab/Anchor/Havells/Grandlay
M&L for replacement of unsv sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4.0 Sqmm and one run of 4.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit/concealed of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable and with one run of earth wire and PVC conduit shall be measured & paid for as one length. Make of wire : Polycab/Anchor/Havells/Grandlay
M&L for replacement of unsv sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6.0 Sqmm and one run of 6.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit / concealed of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable and with one run of earth wire and PVC conduit shall be measured & paid for as one length. Make of wire : Polycab/Anchor/Havells/Grandlay
M&L for replacement of unsv sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 10.0 Sqmm and one run of 10.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit / concealed of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length. Make of wire : Polycab/Anchor/Havells/Grandlay
M&L for replacement of unsv sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 10.0 Sqmm and one run of 10.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red/Blue/Yellow, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit / concealed of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: four runs of cable and with one run of earth wire and PVC conduit shall be measured & paid for as one length. Make of wire : Polycab/Anchor/Havells/Grandlay
Taking out old earthing and M&L for replacement of old unsv Earthing complete with GI steel earth plate eletrode 60 cm X 60 cm X 6.0 mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metres below level ground,connected to Gl iron or steel earth wire 4 mm dia (8 SWG) by means of nuts,bolts checks nuts and washers made of Gl iron or steel earth wire protected by Gl iron pipe 15 mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6:) type C1, pre-cast RCC coverslab 30 cm X30 cm X 10 cm with one lifting handle made of 8 mm dia ms bar funnel wire mesh,20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges,necessary excavation and earth work in any type of soil complete all as shownin electrical plate No 3 of MES schedule part-I and testing after completion.
Shri Ram Traders Co
vinayandsons
VARDHMAN SALES CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .