Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹40.5 L+₹1.1 L (2.76%)Rejected-AOC 36A 60 CIVIL LINE TELIYAR GANJ ALLAHABAD UTTAR PRADESH 211004 | PRAYAGRAJ | UTTAR PRADESH | 211004 | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹48.2 L+₹8.8 L (22.4%)Rejected-AOC PITHORAGARH PIN 900 336 C O 56 APO | 900336 | L3 | Rejected-AOC AOC rejected. | |
| 4 | Rejected-Technical FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical Not enlisted in appropriate cat. | |
| 5 | Rejected-Technical 11 4 INDER BAWA MARG KISHAPUR RAJPUR ROAD RAJPUR DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical Not enlisted in appropriate cat. |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
4 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Certain Minor and Rev works under GE Dehradun.
2023_MES_578871_1
8570/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dehradun
Class D cat a (i) and b (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹84,000
Yes
30 Mar 2023
3 Feb 2023
6 Mar 2023
3 Feb 2023
4 Mar 2023
18 Feb 2023
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out any type of soil complete all as specified and as directed.
Excavating in trenches in any type of soil , n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out any type of soil complete all as specified.
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unsv LT Cable for laying of cable and getting out complete all as specified and as directed.
Excavation in post holes (or similar holes) each n.exc 0.50 cum getting out, returning, filling and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface of soft/losse soil complete all as specified and directed.
Excavation in trenches n exc. 1.5 m wide but exc 1.5m deep but n.exec 3.0 m deep for erection of pole in any type of soil complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15 cm thickness(below or above ground level) complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets as in roof coverings complete all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section in any position in unframed work complete all as specified and directed.
Material & Labour for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete etc complete all as specified and directed.
Material & Labour for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone agg as in sub base for laying floor finishes complete all as specified and as directed.
Material & Labour for Durastone heavy duty coloured tile 300mmx300mmx9-10mm or 450mm x 450mm x 9-10mm thick exterior grade set and jointed with neat cement slurry and pointed in coloured of white cement to match all as specified.
Material & Labour for Cement concrete in 1;4:8 type D-2 (40 mm graded stone aggregate) as in foundations, filling and mass-concrete complete all as specified
Material & Labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified
Material & Labour for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm any type of soil complete all as specified
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified
Material & labour for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge.
Material & labour for sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and as directed.
Material & labour machine pressed precast concrete interlocking paver blocks any shape and size conforming to IS 15658-2006, 60mm thick, M-35 grade with grey cement and no pigment, laid in any pattern as approved with & including screed bed or bedding layer of mortar 20mm thick in cement motar 1:6 for laying floor finish complete all as specified and directed.
Material and labour for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified
Material & Labour for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified
Supply and fixing Acrylic sheet of 3 mm thick for covering of garden,balconies etc as specified and directed by Eng- in - charge.
Material & Labour for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified
Material & Labour for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified
Material & Labour for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified
Material & Labour for RCC M-25 { using 20 mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc and mass concrete complete all as specified and directed by Engineer-in-Charge
Material & Labour for RCC M-25 { using 20 mm graded stone aggregate) as in Chajjas complete all as specified and directed by Engineer-in-Charge
Material & Labour for RCC M-25 { using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge
Supply and fix of mild steel work as in, posts and struts for fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe – 290 Gde E -165 complete all as specified and directed.
Material & Labour for RCC M-25 { using 20 mm graded stone aggregate) as in beams,cantilevers,wall bends, bressummers, lintels over 1.5m span complete all as specified.
Material & Labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified
All as per item No 32 here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified.
Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by Engr-in-Charge.
Use and waste for Formwork to chullah hoods chajjas trough and similar items including edge Complete all as specified and as directed by Engr-in-Charge.
Use and waste for Formwork to sides and soffits of floor or roof beams, wall bend beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Complete all as specified
Supply and fix for Steel work in tubular trusses/purlin including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed
Supply and fix Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, staging for water tanks, gusset plates etc. conforming Fe-290 (Gde E-165) complete all as specified and as directed.
Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to walls/chajja covering etc fixed with self tapping screws as specified and as directed by Engr-in-Charge.
Supply anf fix pre-painted galvalume aluminium Zinc coating GI based plain steel sheet to match with profile sheet in 0.50mm thick of any approved colour having tensile strenth of 550 Mpa as in ridge,vally/gutter of roof/water drainage(Patnala) , fixed with self tapping screws as specified and complete all as directed by Engr-in-Charge.
Supply and fix Fibre glass reinforced translucent corrugated sheeting 2.00 mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed by Engr-in-Charge.
Material and labour cement concrete 1:2:4 type B0 40mm thick in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified.
Material & Labour for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) for coping pole including necessary form work and finishing exposed faces of concrete smooth and even using extra cement all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in benching to drain , padding to roof chajja, cill, steps, hold fast, coping, bed block etc. including necessary weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed.
Material & Labour for 15 mm thick rendering in cement mortar 1:4 on on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specifeid and as directed.
Material & Labour 15 mm thick rendering in cement mortar (1:6) on fair faces of brick work finished even and smooth without using extra cement complete all as specified and as directed.
Material & Labour for preparation of plastered surfaces of external wall and applying two coats of exterior grade 1st quality weather coat paints over 2-3mm thick wall care putty finish wall surface even & smooth by roller complete all as specified and as directed.
Material & Labour for preparation of new plastered surface of walls including corners and applying two coats of distemper oil emulsion over 2-3mm thick wall care putty finish wall surface even & smooth by roller complete all as specified and as directed by Engr-in-Charge.
Supply and fix Pressed steel frames of size 125x60 mm doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, complete all as specified and as directed.
Supply and fix 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete complete all as specified and as directed.
Supply and fix 35mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and as directed.
Supply and fix for solid PVC factory made door frame (chowkhat) of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, supplying & fixing in opening as per specification and directed by Engr-in-Charge.
Supply and fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as directed by Engineer in Charge.
Supply and fix Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
Supply and fix 200 mm long, solid in one piece stainless steel 202 grade bright finish barrel tower bolts 10mm dia shoot complete all as specified and directed by Engr-in-charge.
Supply and fix 150 mm long, solid in one piece stainless steel 202 grade bright finish barrel tower bolts 10mm dia shoot complete all as specified and directed by Engr-in-charge.
Supply and fix 150mm size solid in one piece stainless steel 202 grade bright finish handles, D type and fixed with stainless steel screws complete all as specified and directed by Engr-in-Charge.
Supply and fix 125mm size solid in one piece stainless steel 202 grade bright finish handles, D type and fixed with stainless steel screws complete all as specified and directed by Engr-in-Charge.
Supply and fix 100 mm size stainless steel butt hinges medium weight cold rolled fixed/ welded to frame complete all as directed.
Supply and fix for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W (Gde E- 250) quality A complete all as specified and directed.
Supply and fix stainless steel sliding door bolts SS204 grade, hasp and staple type with bright bolt not less than 16mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate of size 300mm long complete all as specified
Supply and fix Floor door stopper of Aluminium alloy body double spring and tongue, overall length of cover plate 150 mm , anodized, with hard drawn steel spring , fixed to shutters complete all as specified and as directed.
Supply and fix factory made steel window made out of steel square/rectangular hollow section including MS hinges, steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed. Note :-Sample and design of steel window shall be approved by Garrison Engineer before execution of work
Supply and fix factory made steel window made out of steel square/rectangular hollow section including MS hinges, steel handle and steel peg stay, complete with glazing bars, dovetailed or weldedcomplete all as specified and directed. Note :-Sample and design of steel window shall be approved by Garrison Engineer before execution of work
Supply and fix stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm complete all as specified
Supply and fix 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified
Material & Labour for preparation of newly steel Surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified
Material & Labour for preparation of new wooden surface 10 cm width or grith not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified
Material & labour applying two coats of cement base paint over a coat of cement primer on newly/ old plastered surfaces of wall complete all as specified and directed.
Material & Labour for hardcore of gauge exc 63 mm but n.exc 100 mm deposited, spread and leveled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surfaces in broken stone or boulder complete all as specified and as directed.
Material & Labour for 100mm thick cement concrete 1:4:8 type D2 40mm graded stone aggregate as in sub base of floor for lay floor finish complete all as specified and directed
Material & Labour 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand mixer 1:3 by weight, surface finished even and fair without using extra cement complete all as specified
Material & Labour factory made prepolished rubber moulded vibromatic Chequred cement concrete tiles 30cmx30cmx22-25mm thick, set jointed and pointed in neat cement slurry with grey cement and colour pigment to match over and including 15mm thick screed bedding layer in CM (1:6) complete all as specified.
Material & Labour vitrified ceramic coloured tiles 10 mm thick (square/rectangular) polished,area of each tiles not exceeding 0.36 sqm, in floor etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified
All as per item No 74 here-in-above here in above but as in skirting and including 10 mm thick rendering in cement mortar 1:4, complete all as specified.
Material & Labour non skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 7-8 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
Material & Labour glazed ceramic colour tiles size 300 mm x 450 mm x 7-8 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified
Supply & fixing tiled false ceiling of Everest Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 3mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engineer-in-Charge.
Supply and fix Vitreous China Urinals, half stall type white (back or corner wall type), complete including providing and fixing plugs, bedding urinals against wall in CM 1:2, securing urinals to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, CP waste coupling, waste pipe, automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete. complete all as specified and as directed by Engr-in-Charge.
Supply and fix vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) water closet, including connection to trap and to flushing pipe, anti syphonage pipe etc, and making good to floor complete all as specified and as directed by Engr-in-Charge.
Supply and fix 10 litres capacity PVC low level valve less symphonic action type flushing cistern white with inlet, float valve, float and handle including brackets with 32 mm dia PVC pipe 600 mm long complete all as specified and as directed by Engr-in-Charge.
Supply only PVC connection 15 mm dia 450 to 600 mm long with brass fly nut at both ends complete all as specified and as directed.
Supply and fix 500 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, including supply & fix 20 mm dia GI light grade wash out pipe 450 mm long with plug and 20 mm dia GI light grade over flow pipe 600 mm long with fitting complete all as specified.
Supply & fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 25 mm bore size complete all as specified.
Supply and fix 20 mm bore Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified.
Supply and fix Vitreous China wash hand basin, white, oval type counter top of size 550mm x 400 mm fixed on and including cast iron cantilever bracket, 32 mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete all as specified and as directed. Note: Pillar tap shall be measured as supply only under respective item.
Supply and fix 15mm dia swan neck pillar tap (for oval type WHB) brass chromium plated with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, and fixed complete all as specified and as directed by Engr-in-Charge.
Supply and fix 15 mm dia bore fancy type chromium plated concealed stop cock, complete all as specified and as directed.
Supply and fix fancy type brass chromium plated shower rose with shower arms with swivel joints including fixing to steel pipe of 15 mm dia or union complete all as specified and as directed.
Supply and fix brass chromium plated angle cock 15 mm dia screwed for iron pipe or brass ferrule complete all as specified and as directed.
Supply and fix 15 mm bore bib taps, chromium plated cast copper alloy long body, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Supply and fix Chromium Plated brass soap dish fixed to wall with chromium plated brass screwed and cup washer complete all as specified and directed.
Supply and fix brass chromium plated towel rail, 20 mm dia 'D' type 60 cm long between flanges complete all as specified and directed.
Material and labour PVC (SWR) floor trap plain with grating including jointing with solvent cement 75 mm bore outlet complete all as specified and as directed.
Supply and fix PVC (SWR) soil waste & vent pipe in any length without ears laid in floors, trenches or fixed to wall complete for 75 mm dia bore of pipe complete all as specified and as directed.
Supply and fix PVC (SWR) soil waste & vent pipe in any length without ears laid in floors, trenches or fixed to wall complete for 110 mm dia bore of pipe complete all as specified and as directed.
Supply and fix PVC (SWR) bends, T, reducer any radius with rubber ring joints, fixed to wall / floor / in trenches complete all as specified and directed for 75 mm dia pipe complete all as specified and as directed.
Supply and fix PVC (SWR) bends, T, reducer any radius with rubber ring joints, fixed to wall / floor / in trenches complete all as specified and directed for 110 mm dia pipe complete all as specified and as directed..
Supply and fix 110 mm dia PVC (SWR) vent cowl complete all as specified and directed. Make : Supreme/finolex
Material & Labour for Soakage well, excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM 1:4, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size of 1.2 Mtr x 3.00 Mtr effective depth complete all as directed by Engr-in-Charge
Supply and fix MCB TPN 415 Volt 10 KA 63 Amp conforming to IS complete all as specified
Material & Labour for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
Supply and laying galvanised steel tubing 50 mm bore light grade laid in trenches or fixed to poles/walls etc for cable protection complete all as specified and directed.
Material and labour GI tubing medium grade, complete with all fittings for installation of post top Lantern fitting of 50 mm bore complete all as specified and directed.
Supply, laying, jointing and testing of underground XLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sq mm, 2 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed.
All as per Item No 106 here-in-above but 6 Sq mm, 2 core complete all as specified and directed.
Supplying, transporting, errecting and fixing in replacement Steel tubular swaged poles type 410 SP-31, 9.00 metre long , complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified including painting with two coats of synthetic enamalled paint over one coat of red oxide primer and 06 Nos bands/ straps with yellow and black colour ( 30 cm wide each)epoxy heat resistant paint at a distance 30 cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including tarring/Bituminous paint one coat on steel surface embedded in concrete foundation complete all as specified and shown on drawings and directed.
All as per item No 108 here-in-above but 11 metre long complete all as specified.
Supply only PVC (Tharmoplastic) street light junction box 250X200X100mm, heavy duty with locking arrangement, single phase and neutral two Nos copper busbar with hole for incoming and outgoing cable of size 6/10/16/25 sqmm 2 core, busbar of capacity 100 Amp PVC conduit up to the height of bottom level level of PVC Junction box from GL along with necessary MS clamp, nuts bolts and washers for fixing and one No. MCB Single Pole 240 Volts 6 Amps complete all as specified and directed. Make :-Sintex or equivalent as approved by GE.
All as per Item No 110 here-in-above but size of 140X140X95mm complete all as specified and directed.
Material & Labour GI bracket made out of 40 mm GI pipe medium grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps 02 Nos not less than 50x6 mm MS flat duly painted, nuts, bolts and washer complete all as directed
Supply only Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 70/72 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed.. Make:- Philips model No. BRP410LEDCW072MRFGSIPSUGR Havells model No. LHETBXU7PA6J070 and syska cat No- SSK-ST 60W including taking out old unserviceable street light.
Supply and fix LED decorative post top lantern for Garden light 40 watt IP 65 protection resistance to impact and corrosion glare, free and better uniformity milky version as per CG cat part No LPTO40CDL/ Bajaj model No. BGCTW4LEDWW including taking down old unserviceable post of lantern.
Supply only of 3 core 1.5 Sqmm copper conductor cable in existing pole incl making holes for cable entry and exist near to light fitting and junction box complete all as directed.
Supply install, testing and commissioning LT Distribution Panel (CPRI approved) as per IS / ICE 61439-part I&II, Cubicle type,IP-65, outdoor type, factory fabricated made out of 3 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings, compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The incoming as well as outgoint MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links / interconnections shall be insulated with colour coded heat shrinkable sleeve . The cubicle shall have frame work, bottom & 45 CM iong 4 legsof size 50 x 50 x 6 mm Angle iron, grouted in PCC 1:3:6 as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and including 1 Cum PCC 1:3:6 foundation as directed by Engr-in-Charge . The panel comprising of following.: Note:- LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for TEMPERATURE RISE TEST, DI – ELECTRIC TEST and Degree of protection IP – 65 at minimum 4000 Amps with Breaking capacity not less then 65KA. Panel Builder should submit all Certificates before executing the job.) Make of panel boards: Legrand/ABB/Schneider/ Shalabh/Tricolite.
All as per item No 116 here-in above but LT Panel with following switch gear complete all as specified. Incoming :- (a) Insulation epoxy painted high conductivity alluminium bus bar 250 Amps for 3 phase and neutral complete all as specified and directed. (b) Digital Voltmeter 0 to 500 Volts - 01 set (c) Digital Ampere meter 0 to 200 Amps capacity - 01 Set (d) Indicating lamps Neon type for RYB - 01 set (e) MCCB 4 Pole 415 volts 160 Amps, 16 KA as incoming - 01 Nos. Outgoing ;- (a) MCCB 4 Pole 415 volts 63 Amps, 16 KA as outgoing - 03 Nos. (b) S&FStreet light TIMER control panel, 110 Amps, 3 pole/420Volt, DIGITAL time switch including internal wiring complete with by pass arrangements complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of L.T Panel, thermoplastic Polycarbonate IP 65 Distribution Board in accordance with IEC 60 529 (Dust Proof, Water Proof & Weatherproof) Thermoplastic Polycarbonate DB of Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, Fire Retardant & Self Extinguishing, UV Resistant, Silica and Halogen Free recyclable material. Type tasted as per IEC 61 439-1. Total Insulated with System Voltage 415V AC, 50Hz, and 5 wires. The board/panel should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:The panel should be anti-acid & anti corrosive. in accordance with IEC 62262.Outdoor Floor mounting with the following switch gears . Incomer:- 400 Amps 4P, 50 KA ON LOAD change over switch - 01 Nos. 400 Amps 4P, 50 KA MCCB- 01 Nos. Multifunction Meter-01 Nos. RYB Indication Lamp -01 Nos. Outgoing:- 250 Amp FP,36 KA MCCB- 01 Nos. 160 Amp FP,25 KA MCCB- 02 Nos. 125 Amp FP,25 KA MCCB- 01 Nos. 63 Amp FP,16 KA MCCB- 01 Nos
Material and labour for earthing complete with GI or steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI earth wire 4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed by Engr-in-Charge.
Material and labour for bending & shaping of 25 mm dia galvanised iron pipe light grade over all length 0.60 mtr including necessary clamps, brackets and bolts mtr etc to fixed on wall/pole as per site requirement including fixing on pole with light fittings complete all as specified and as directed.
Supply and fix junction box made out of glass fibre reinforced and transparent poly carbonate of size 250x200x111, KV PC 8104 with IP 65 protection including MCB TPN 40 to 60 Amps 1 No and suitable size clamps fixing for pole/in pcc foundation etc complete all as specified and as directed..
S&F junction box made out of glass fibre reinforced and transparent poly carbonate of size 300x200x111, KV PC 8104 with IP 65 protection including MCB SP 6 to 32 Amps 4 No and suitable size clamps fixing for pole/in pcc foundation etc complete all as specified and as directed.
Material and labour for cement concrete (1:3:6), type C-1, using 20 mm graded crushed stone aggregate for pedestal of poles/coping including necessary form work, fair finishes to the exposed surface using extra cement all as specified and directed.
Supply and laying XLPE insulated galvanized steel strip or wire armoured electric power cable with stranded aluminium conductor 1100V grade of size 50 Sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts and lugs complete all as specified and directed.
All as per items No 124 here-in-above but cable size 16 Sqmm 4 core
Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 35 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs complete all as specified and directed.
All as per item No 126 here-in-above but XLPE cable of size 25 sqmm 4 core
All as per item No 126 here-in-above but XLPE cable of size 10 Sqmm 4 Core
Supply and fix junction box made out of glass fibre reinforced and transparent poly carbonate of size 126x228x111, KV PC 8104 with IP 65 protection including MCB SP, 6 Amps 1 No and suitable size clamps fixing for pole/in pcc foundation etc complete all as specified and as directed..
Supply and fix junction box made out of glass fibre reinforced and transparent poly carbonate of size 126x228x111, KV PC 8104 with IP 65 protection including 5/15 Amp Switch socket comination 1 No and suitable size clamps fixing for pole/in pcc foundation etc complete all as specified and as directed..
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply and fix Flood light 50 Watt RGB Colour,Complete all as specified and as directed.
Supply and fix Garden Light fitting, 25 Watt LED Decorative Post top ,including taking down the old one Complete all as specified and as directed.
Supply and fix LED bollard type fitting 9/10 Watt cpacity 650 mm height, LED bollard AFlare fitted with low glare diffuser with IP 65 protection, complete with necessary 0.054 Sqm PCC foundation/ Light including taking down existing old pattern unserviceable light fitting all as specified and directed.
Material and labour PVC insulated copper conductor 3 core 1.5 sqmm cable to be drawn inside the pole, including taking down of old one, all as specified & as directed.
Material and labour for Distribution board Vertical type TPN 4 Way double door, suitable for MCCB 63/100 Amps MCCB as incoming and MCBs for outgoing factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection incl taking out old u/s complete all as specified and as directed by Engr-in-Charge.
Supply and fix MCCB 63 Amps four pole 415 volts thermal magnetic release ICU=100% ICS having breaking capacity 16 KA including connection terminal strip complete all as specified & directed
Supply and fix Sheet metal enclosure MCB DB, double door , 08 way SPN, 240 volts with 200 Amps rated bus bar with blanking plates wherever required and I.P. 20 degree protection complete all as specified and as directed.
Supply and fix MCB single pole and neutral 240 volts, 25 to 40 Amps complete all as specified and as directed.
Supply and fix MCB single pole 240 volts, 6 to 32 Amps complete all as specified and as directed.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed.
Material and labour for sub main wiring with 2 runx 6 Sqmm + 6 sqmm earth wire single core PVC insulated cable unseathed multistranded copper conductor LT 1100 volts grade FRLS cable IS-694 (ISI marked with valid CML No ) drawn in & icluding PVC conduit of dia not less than 25mm in concealed (ISI marked with valide CML No ) including its all fittings/accessoreis with one run single core copper cable 4 sqmm multistranded conductor (ISI marked with valide CML No) colour code as a earth continuity and connecting upto DB with suitable lugs all as specifed and directed.
Supply and fix LED focus light 12 Watt complete all as specified and directed.
Supply and fix LED down lighter consealed ceiling light 12W Sky Spot COB (WW) complete all as specified and directed.
Supply and fix LED focus light (Bed Lamp) 3 Watt Warm White complete all as specified and directed.
Cutting existing road/hardstanding of any type by using crow bar chisel upto a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCCB 200 Amps, 4 Pole , 25 KA with SS enclosure for 4 pole , Frame 1, all as specified and directed by Engr-in-Charge
Material and labour for Under gorund pneumatic horrzondal drilling (HDD) of holes under road, pavment, hard stanading as required length at site by trenchless technology using ultra sound technique with necessary horrizondal direction drilling (HDD) machine including providing HDPE Pipe 50 mm outer dia 0.40 mpa including necessary joint connections and laying LT/HT cable. The contractor shall be conduct under ground scanning to detect existing HT/LT cable line , sewage line, OFC Cable etc to avoid damage. The entry/exist hoel must be large enough to fit the drilling tool and the operator in it so they can aim the tool. The hole also must be deep enough that as the tool compacts the ground and the surface to be remain undisturbed. The deapth of the startiung bore pit depends on the type of the soil that is being worked in and how well it compacts. The operator shall aim the tool toi the desire exit point and allow it to perform it function creeating a bore hole under the ground without disturbing surfaces. The operator also should monitor the surface to make sure that, it is undisturbed. As the tool near to the exit point it is slowed down and the exit pit should be dug to locate both the tool and the bore. As the tool enters the exit pit the operator should choose either digup the tool to retrive it or reverses the tool back into the first bore pit to retrieve it including connected earth work, all as specified and directed by Engr-in-Charge
Supply, fixing, testing & install Smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition.
Supply, installation, testing and commissioning in replacement of L.T Panel, thermoplastic Polycarbonate IP 65 Distribution Board in accordance with IEC 60 529 (Dust Proof, Water Proof & Weatherproof) Thermoplastic Polycarbonate DB of Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, Fire Retardant & Self Extinguishing, UV Resistant, Silica and Halogen Free recyclable material. Type tasted as per IEC 61 439-1. Total Insulated with System Voltage 415V AC, 50Hz, and 5 wires. The board/panel should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:The panel should be anti-acid & anti corrosive. in accordance with IEC 62262.Outdoor Floor mounting with the following switch gears . Incomer - 200 Amps 4P, 25 KA ON LOAD change over switch - 01 Nos. 200 Amps 4P, 25 KA MCCB Thermal Magnetic adjustable - 01 Nos. Multifunction Meter-01 Nos. RYB Indication Lamp -01 Nos. Outgoing- 100 Amp FP,36 KA MCCB- 03 Nos. 63 Amp FP,16 KA MCCB- 01 Nos KWH meter 3 Phase measuring range 0- 200 Amp - 01 (for measuring consumption of electricity)
Taking out DI/CI pipe line of any size (including all fittings) with spigot and socketed ends with tyton joints type complete all as specified and as directed
Relaying of DI/CI pipe line of any size (including all fittings) with spigot and socketed ends with tyton joints all as specified and as directed
Laying only pipe Ductile iron of size 300 mm bore all as directed by Engineer-in-charge. Note :- 300 CI pipe line will be issued by department under Sch 'B' free for fixing complete all as specified and as directed.
Supply and fix pipe Ductile iron SS class "K7" 150 mm bore ISI marked as per IS 8329 and laid complete all as specified and as directed.
Material and labour for tyton rubber gasket joints for 300/200 mm bore complete all as specified and directed
Labour for shifting of CI Pipe line of any size from MES store yard to work site all as directed by Engir-in-charge. Note (i) it is contractor's responsibility that pipe line should not be damage during shifting of pipe line (ii) It is the responsibility of contractor to manage all T& P without any extra cost required for shifting of pipe line complete all as specified and as directed.
Material and labour Cutting of cast iron pipe mains for insertion of tees, colars, sluice valves, etc for the following bores ncluiding dewatering work required for working water pipe lines upto 200 mm dia bore complete all as directed by Engr-in-Charge.
Supply & Fix in repair CI mechanical joint socket type complete with jointing materials such as rubber gaskets, nut bolts, & washers but for the cast iron pipe of 300/200 mm bore complete all as specified and directed.
Material and labour ffor CI/DI fitting for spigot & socket end pipes such as Bends (any type, radius and angle), upto 300 mm bore complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of size 120 cm x 120 cm x 120 cm with necessary excavation , returing filling in, steel work for cover using MS sheet 3 mm thick welded/hinged MS angle iron 40x40x6mm forged flat iron hinges, sliding type lifting handle of MS bar 12 mm dia all as directed by Engr-in-Charge.
Material and labour for point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic rigid PVC concealed/ conduit on wall as required for One light point point controlled by one-one way switch complete all as specified and as directed.
All as per item No 161 here-in- above but One light point point controlled by one-one way switch.
All as per item No 161 here-in- above but One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
All as per item No 161 here-in-above but One three pin 5 Amp socket on same board with other switches.
All as per item No 161 here-in-above butOne three pin 5 Amp socket on independent board.
All as per item No 161 here-in-above but with 2.5 Sq.mm. (nominal area) cable for one 3 Pin 15 amp socket on independent board complete.
Supply and fix switch piano flush, button type 5 Amp SP 250V AC complete all as specified and as directed.
Supply and fix switch piano flush button type 15 Amps SP 250V AC complete all as specified and as directed.
Supply and fix socket outlet 2-in-1, 5 Pin 5 Amps 250V AC complete all as specified and as directed.
Supply and fix socket outlet 2-in1,3 pin 5 and 15 Amp flush type 250V AC complete all as specified and as directed.
Supply and fix ceiling rose surface bakelite 3 terminals of size 65x25mm. complete all as specified and as directed.
Supply and fix LED tube light alluminium extruded body with intergrated electronic driver , 20 W complete all as specified and directed. Make Philips Cat No BN 021 LED40S- 6500 PSU GR (4 ft) (Test certificate to be submitted) or equivalent as approved by GE.
Supply and fixLED Mirror Lamp, 2 feet, 10 Watt, 230V, surface mounted decorative mirror optic type with engineered plastic body and including tube rod and connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed.
Supply and fix in replacement BLDC Ceiling Fan complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz of , complete connecting up ceiling rose to connector block of fan including fabricating and fixing of Fan hooks from ceiling truss/angle iron, required length of down rods (As per site requirement) and necessary nuts and bolts complete all as specified and directed. Note :- Old fans should be deposited to MES store yard
Supply and fix in replacement Exhaust fan exhaust fan 150 mm PVC body made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old metalic exhaust fan complete all as specified and directed. Note : Old fan should be deposited to MES store (Test certificate of fan to be submitted)
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and as directed.
Supply and fix metal clad single pole and neutral enclosure with 2 pin and earth plug and socket complete with and including one single pole MCB 20 Amp 240Volt complete all as specified and as directed.
Supply and fix sheet metal enclosures 240 volt 8 way with suitable rated bus bar for Single door IP-43DB's complete all as specified and directed .
Material and labour for submain wiring with 3 runs(N+P+E) of 4 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed PVC conduit pipe of medium duty not less than 15 mm dia including necessary PVC conduit specials and connecting with suitable size thimble complete all as specified and directed. Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
PRAGATI ENTERPRISES
Mahamaya Engineers Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .