CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati-15 Assam Pin 781015 Tele 0361 2841626
REPAIR AND MAINTENANCE OF CERTAIN CAPACITIES OF AC PLANT FOR OPERATIONAL FLYING UNITS AND WSA COMPLEX AND CONNECTED MISC WORKS AT AF STATION TEZPUR UNDER GE AF TEZPUR 2ND CALL
2020_MES_368934_2
CWE (AF)/TEZ/TOKEN-31 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
TEZPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF Tezpur
₹31,000
Yes
23 Oct 2020
16 Sept 2020
14 Oct 2020
16 Sept 2020
12 Oct 2020
28 Sept 2020
Amount
M&L for preventive maintenance /cleaning of cooling tower -03Nos ( Make MIHIR) of capacity 180 TR fitted with CT fan motor cap 5.5KW/7.5HP the bottom tub shall be cleaned thoroughly by necessary cleaning agent including checking of serviceability of CT fan tightness and bearing smoothness,fan blade tightness, ,correctness of alignment of circular type sprinkler branch line and ensuring periodical cleaning / proper supply of water from make up tank 30000 litre capacity all as directed by Engr-in-charge. Note : (i) Cleaning /servicing activities to be carried out once in a month interval by a qualified technician. (ii) Any type of T&P and cleaning agent such as detergent,wire brush etc required shall be arranged by the contractor and included in the quoted rate.
M&L for descaling of 3 x 180 TR rating AC Plant at DRDO complex by the expert Refrigerator Mechanics which includes the following :- (a) Transporting and providing special T&P, descaling solution in sealed containers from manufacturer's outlet to site of work in side tech area. (b) Expert Engineers with team of trained refrigerator mechanic to check the three units of AC plants for external setting of components, disconnection and detecting damages/faults. (c) Opening of end covers and inside water circulating tubes of evaporator and condenser units of all three chillers. (d) M&L for fixing short pipe sockets of mild steel tubing 25 mm dia for entry & outlet of condenser and evaporator for faciliting circulation of descaling solution by 1 HP mono block pump set after mixing it in water in ratio of 1:5 for 24 hours. Note :- (a) Supplying the chemical solution for descaling solution for descaling is included in the unit rate quoted. (b) Strength of descaling solution shall be measured with pH paper and if the strength is less than 30%, then the descaling has to be done again by the contractor at his own cost to achieve the desired level of pH and nothing shall be payable extra on this account. (c) In case of damages of any equipment due to negligency of labour the same shall be got repaired by the contractor at his own cost and nothing extra shall be payable on this account.
M & L for servicing,cleaning of prefilter/fine filter pads completely by removing from AHU units ( CSUs) and making dust free by air pressure /watering drying and refixing at position including checking of serviceability of dehumidifier pumpset 0.5 HP cap and blower motor 1.5 HP cap including fan belt tightness ,serviceability by of blower motor once in two months intervel all as directed by engineer in charge in the following locations: (a) Building no B1=31 AHUs (b) Building no B2= 25 AHUs (c) Building no B3 = 16 AHUs
M & L for servicing,cleaning of prefilter/fine filter pads completely by removing from AHU units ( Floor mounted ) and making dust free by air pressure ,watering drying and refixing at position including checking of serviceability of dehumidifier pumpset 2 HP cap and blower motor 7.5 HP cap including fan belt tightness ,serviceability by of blower motor once in two months intervel all as directed by engineer in charge in the following locations: (a) Building no B4=06 AHUs (b) Building no B5 = 02AHUs
Servicing and maintenance of Rapid cool cap 90 KW Hot water generator (total- 3 Nos) complete by opening the existing assy and draining out complete water cleaning the container checking of serviceability of heating element, pressure gauge etc. and reassembling the same and testing all as specified and as directed. all as specified and directed
Servicing and maintenance of Rapid cool cap 45 KW Hot water generator (total - 4 Nos) complete by opening the existing assembly and draining out complete water cleaning the container checking of serviceability of heating element, pressure gauge etc. and reassembling the same and testing all as specified and as directed.
Supply and fix in repair immersion type water heater assembly of capacity 15 KW suitable for Emrald make hot water generator complete all as per existing model and as directed
Supply and fix in repair immersion type water heater assembly of capacity 25 KW suitable for Emrald make hot water generator complete all as per existing model and as directed
Supply and fix in repair pre filters type EU4/G4 suitable for air handling unit, box type with aluminium extruded section frame and body of size 610x610x50mm and efficiency 90% down to 10 micron particle size complete all as directed. Make – Thermodyne/Purolator/ Athlete etc
All as per item No. 9 here-in-before but size 610mmx305mmx50mm complete all as specified and as directed.
All as per item No.9 here-in-before but size 305mmx305mmx50mm complete all as specified and as directed.
All as per item No.9 here-in-before but size 500mmx500mmx50mm complete all as specified and as directed.
Maintenance ,overhauling and serviceing central type water cooled AC plant capacity 120 X 3 TR (For First flight hanger 1) and descaling of AHUs (AHU capacity 6500 CFM qty - 03, AHU capacity 8500 CFM qty - 02, AHU capacity 11000 CFM qty - 05) cleaning of all AHU Filters, descaling of condensor unit with appropriate cleaning agent,soap wash and by using dilute de-scaling agents, removing the de-scalings by pump & motor mechanism and cleaning agent including leakage testing of seal system by nitrogen pressure and vaccuming for 24 hour and descaling of Chiller Condensers unit maintenance of blower motor unit and maintenance of referigerant gas filter and water pipe line valve complete all as specified and as directed. Note: All of above job shall be done by trained and qualified employees of OEM. (For 106 Sqn Hanger)
Maintenance ,overhauling and serviceing central type water cooled AC plant capacity 120 X 3 TR (For First flight hanger 2) and descaling of AHUs (AHU capacity 6500 CFM qty - 03, AHU capacity 8500 CFM qty - 02, AHU capacity 11000 CFM qty - 05) cleaning of all AHU Filters, descaling of condensor unit with appropriate cleaning agent,soap wash and by using dilute de-scaling agents, removing the de-scalings by pump & motor mechanism and cleaning agent including leakage testing of seal system by nitrogen pressure and vaccuming for 24 hour and descaling of Chiller Condensers unit maintenance of blower motor unit and maintenance of referigerant gas filter and water pipe line valve complete all as specified and as directed. Note: All of above job shall be done by trained and qualified employees of OEM (For 2 Sqn hanger).
M&L for preventive maintenance,cleaning of cooling tower-02Nos ( Make MIHIR) of capacity 150 TR (For 106 Sqn Hanger) fitted with CT fan motor cap 5.5KW/7.5HP the bottom tub shall be cleaned thoroughly by necessary cleaning agent including checking of serviceability of CT fan tightness and bearing smoothness,fan blade tightness, ,correctness of alignment of circular type sprinkler branch line and ensuring periodical cleaning and proper supply of water from make up tank 30000 litre capacity all as directed by Engr-in-charge. Note : (i) Cleaning and servicing activities to be carried out once in a month interval by a qualified technician. (ii) Any type of T&P and cleaning agent such as detergent,wire brush etc required shall be arranged by the contractor and included in the quoted rate.
M&L for preventive maintenance, cleaning of cooling tower -02Nos ( Make MIHIR) of capacity 150 TR (For 2 Sqn Hanger) fitted with CT fan motor cap 5.5KW/7.5HP the bottom tub shall be cleaned thoroughly by necessary cleaning agent including checking of serviceability of CT fan tightness and bearing smoothness,fan blade tightness, ,correctness of alignment of circular type sprinkler branch line and ensuring periodical cleaning and proper supply of water from make up tank 30000 litre capacity all as directed by Engr-in-charge. Note : (i) Cleaning and servicing activities to be carried out once in a month interval by a qualified technician. (ii) Any type of T&P and cleaning agent such as detergent,wire brush etc required shall be arranged by the contractor and included in the quoted rate.
M&L for disconnecting taking down mechanically and electrically unserviceable blower fan motor for 1.5 KW/ 2 HP capacity from the AHU system, shifting to civil workshop, dismantling the electric motor and removing burnt out windings, cleaning the slots, rewinding with super enemelled copper winding wire as per existing gauge and size varnishing and drying complete, reassembling, replacing the ball bearings as per existing size and make and transporting to site, re-fixing at original position, connecting electrically and mechanically, testing for satisfactory working all as directed.
M&L for disconnecting and taking down mechanically and electrically unserviceable primary water pump motor 4 HP capacity for chiller unit, head 10 mtrs and shifting to civil workshop, dismantling the electric motor and removing burnt out windings, cleaning the slots, rewinding with super enemelled copper winding wire as per existing gauge and size varnishing, drying complete, reassembling, replacing the ball bearings as per existing size and make and transporting to site, re-fixing at original position, connecting electrically and mechanically, testing for satisfactory working all as directed.
M&L for disconnecting and taking down mechanically and electrically unserviceable primary water pump motor 10 HP capacity for chiller unit, 1430 RPM and shifting to civil workshop, dismantling the electric motor , removing burnt out windings, cleaning the slots, rewinding with super enemelled copper winding wire as per existing gauge and size varnishing, drying complete, reassembling, replacing the ball bearings as per existing size and make and transporting to site , re-fixing at original position, connecting electrically and mechanically, testing for satisfactory working all as directed.
All as per item No.19 here-in-before but of secondary water pump motor 25 HP capacity for chiller unit, 1430 RPM
All as per item No.19 here-in-before but of secondary water pump motor 30 HP capacity for chiller unit
All as per item No.19 here-in-before but of condensor pump motor 20 HP capacity for 1430 RPM
All as per item No.19 here-in-before but of condensor water pump motor set 7.5 HP capacity
All as per item No. 19 here-in-before but of blower motor 7.5 HP capacity of floor mounted AHUs , 1430 RPM
Taking out the defective dehumidification pump set alongwith motor from the AHU ( CSU Type) by disconnecting electrically and mechanically, shifting to civil workshop, dismantling the same to remove burnt out windings and defective parts, rewinding the motor with super enemelled copper winding wire including all insulating materials all as per existing, varnishing,drying etc complete and replacing the bearings,bushes as per existing size replacing the pump impeller, reassembling the same shifting to original site, reconnecting electrically and mechanically and testing for proper working complete all as specified and directed for the 0.50 HP 230 volts SP 2780 RPM.
All as per item No 25 here-in-above but of 1 HP cap of blower motor all as directed
Taking out Hot water generator pump set alongwith motor by disconnecting electrically and mechanically, shifting to civil workshop, dismantling the same to remove burnt out windings and defective parts, rewinding the motor with super enemelled copper winding wire including all insulating materials all as per existing, varnishing,drying etc complete and replacing the bearings,bushes as per existing size replacing the pump impeller, reassembling the same shifting to original site, reconnecting electrically and mechanically and testing for proper working complete all as specified and directed for the 2 HP 230 volts SP 2780 RPM.
All as per item No 27 here-in-above but of 1.5 HP cap of blower motor all as directed
Supply and fix in repair MCCB 100 Amps FP, 36 KA, 415 volts and making all connections complete all as directed. Make L&T/seimens /cromton greeves/Legrand/C&S/ABB
Supply and fix in repair MCCB 80 Amps FP, 25 KA, 415 volts and making all connections complete all as directed. Make L&T/seimens /cromton greeves/Legrand/C&S/ABB
Supply and fix in repair MCCB 63 Amps FP, 25 KA, 415 volts and making all connections complete all as directed. Make L&T/seimens /cromton greeves/Legrand/C&S/ABB
S&F in repair Single phase preventor VSP D-1 Make : L&T/Siemens/Minilec/Havells/ABB/C&S
S&F in repair V Belt Size A-23 Make : Fenner/Dunlop/Finolex
Supply and fix in repair 3 pole power contactor rated current AC1 125A and AC3 110A with auxiliary contact block, 3 phase 415 volts, with coil voltage 220 volts complete all as directed. Make : Siemens/L&T/Schenider/Legrand/ABB/C&S
Supply and fix in repair 3 pole power contactor rated current AC1 100A and AC3 65A with auxiliary contact block, 3 phase 415 volts, with coil voltage 220 volts complete all as directed. Make : Siemens/L&T/Schenider/Legrand/ABB/C&S
Supply and fix in repair 3 pole power contactor rated current AC1 160A and AC3 110A with auxiliary contact block, 3 phase 415 volts, with coil voltage 220 volts suitable for 120 TR AC plant Make: DAIKIN, Model PFS13510BRY complete all as directed. Make : Siemens/L&T/Schenider/Legrand/ABB/C&S
Supply and fix in repair 3 pole power contactor rated current AC1 90A and AC3 63A with auxiliary contact block, 3 phase 415 volts, with coil voltage 220 volts suitable for 120 TR AC plant Make: DAIKIN, Model PFS13510BRY complete all as directed. Make : Siemens/L&T/Schenider/Legrand/ABB/C&S
Supply and fix in repair power contactor type MNX 25 , 3 phase 415 volts, with coil voltage 220 volts complete all as directed. Make : L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair power contactor type MNX 18 , 3 phase 415 volts, with coil voltage 220 volts complete all as directed. Make : L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair power contactor type MNX 12 , 3 phase 415 volts, with coil voltage 220 volts complete all as directed. Make : L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair power contactor type MNX 9 , 3 phase 415 volts, with coil voltage 220 volts complete all as directed. Make :L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair Over load relay Typ MN-2 range1.4 Amp to 2.3 Amp complete all as directed. Make L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair Over load relay Typ MN-2 range 2.0 Amp to 3.3 Amp complete all as directed. Make L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair Over load relay Typ MN-2 range 6 Amp to 10 Amp complete all as directed. Make L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair Over load relay Type MN-5 range 80 Amp to 110 Amp complete all as directed. Make L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair Over load relay Typ MN-2 range 9 Amp to 15 Amp complete all as directed. Make L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair Over load relay Typ MN-2 range 3 Amp to 5 Amp complete all as directed. Make L&T or equivalent/Siemens/Schenider/Legrand/ABB/C&S
Supply and fix in repair Pressure gauge (0-150PSI) round shape complete all as directed.
Supply and fix in repair Water Temprature Thermometer Round type 100 mm dia 0-60 Degree centigrade complete all as directed.
Supply and fix in repair Water flow switch model WFS6000 complete all as directed.
Supply and fix in repair pilot solenoid 3 way valve (model-TKC-2)suitable for 180 TR AC plant Make: Blue star, Model LCWX2-0665D
Supply and fix in repair suction pressure sensor suitable for 180 TR AC plant Make: Blue star, Model LCWX2-0665D
Supply and fix in repair discharge pressure sensor suitable for 180 TR AC plant Make: Blue star, Model LCWX2-0665D
Supply and fix in repair oil pressure sensor suitable for 180 TR AC plant Make: Blue star, Model LCWX2-0665D
Supply and fix in repair modulating motor valve suitable for 180 TR AC plant Make: Blue star, Model LCWX2-0665D
Supply and fix in repair Digital step controller display complete set for hot water genertaor 45 KW (Model: RC-45, Make: Rapid cool) complete all as specified and directed.
Supply and fix in repair Digital step controller display complete set for hot water genertaor 90 KW (Model: RC-90, Make: Rapid cool) complete all as specified and directed.
Supply and fix in repair temperature sensor for chilled water/condensor/oil/discharge referigerant suitable for 120 TR AC plant Make: DAIKIN, Model PFS13510BRY
Supply and fix in repair pressure transducer for Evaporator/suction/discharge/condensor suitable for 120 TR AC plant Make: DAIKIN, Model PFS13510BRY
Supply and fix in repair oil heater suitable for 120 TR AC plant Make: DAIKIN, Model PFS13510BRY
Supply and fix in repair oil level sensor suitable for 120 TR AC plant Make: DAIKIN, Model PFS13510BRY
Supply and fix in repair loader and unloader coil suitable for 120 TR AC plant Make: DAIKIN, Model PFS13510BRY
Supply and fix in repair Solenoid coil for oil discharge line suitable for 120 TR AC plant Make: DAIKIN, Model PFS13510BRY
Supply and fix in repair antifreezing switch suitable for 120 TR AC plant Make: DAIKIN, Model PFS13510BRY
Supply and fix in repair electronic Timer time range 0.3 to 30 sec, rated control supply voltage ranges (24 V AC/DC / 220-240 V AC, 110-130 V AC and 380-415 V AC). Make : Siemens/L&T/Schenider/ABB
Supply and fix in repair Convertor AC to DC (220 to 24 DC) suitable for 120 TR AC plant Make: DAIKIN/ Siemens/L&T/Schenider/ABB/weidmuller
Supply and fix in repair Thermal Relay CM-MSE suitable for 120 TR AC plant Make: DAIKIN/ Siemens/L&T/Schenider/ABB/weidmuller
Supply and fix in repair fuse 32 A suitable for 120 TR AC plant Make: DAIKIN/L&T or equivalent of Siemens/Schenider
Supply and fix in repair 3 Phase Digital Voltmeter with accuracy class 1.0 complete all as directed.
Supply and fix in repair 3 Phase Digital Ammeter with accuracy class 1.0 complete all as directed.
Supply and charging of Gas R-134-A complete all as directed by Engineer in charge. For Brahmos AC Plant, First flight Hanger 1 & 2 Make : Refron /Mefron
Supply & fix in repair CI butterfly valve PN 1.6 size of dia150 mm. (Make: Advance/L&T/Kirloskar)
Supply & fix in repair CI butterfly valve PN 1.6 size of dia100 mm. (Make: Advance/L&T/Kirloskar)
Supply & fix in repair CI butterfly valve PN 1.6 size of dia 65 mm. (Make: Advance/L&T/Kirloskar)
Supply and fix in repair 25 mm dia gun metal gate valve complete all as specified and directed.
Supply and fix in repair MCB TPN 63 Amps , C curve complete all as directed. Make: ABB/Legrand/L&T/indoasian/Havells
Supply and fix in repair MCB TP 6-32 Amps , C curve complete all as directed. Make: ABB/Legrand/L&T/indoasian/Havells
Supply and fix in repair MCB TPN 6-32 Amps , C curve complete all as directed. Make: ABB/Legrand/L&T/indoasian/Havells
Supply and fix in repair MCB SP 6-32 Amps , C curve complete all as directed. Make: ABB/Legrand/L&T/indoasian/Havells
Supply and fix in repair MCB SP 63 Amps , C curve complete all as directed. Make: ABB/Legrand/L&T/indoasian/Havells
M&L for repair to internal wiring / burnt out wiring of LT panel and supply and rewiring with suitable size single core PVC insulated, unsheathed multi stranded 1100 volts grade copper conductor cable of required sizes from bus bar to outgoing feeders/ starters properly lugged at end terminals , cleaning of panel board , tightening of all connections removing old burnt lugs etc complete all as directed.
S&F Pump set Rocker assembly of any size complete all as directed.
S&F Pump set coupling asssembly of any size complete all as directed.
M/S LAKSHMI COOLING CENTRE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .