Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC L1 being lowest | |
| 2 | L2₹17.5 L+₹6.9 L (64.5%)Rejected-AOC SHALABH HOUSE 490 PURANI TEHSIL ROORKEE DISTT HARIDWAR | HARIDWAR | UTTARAKHAND | 247656 | L2 | Rejected-AOC being not lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
1 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWEHILLS DEHRADUN
CWEHILLSDEHRADUN
REPAIR AND REPLACEMENT OF HT OVER HEAD DISTRIBUTION SYSTEM AND ALLIED WORKS UNDER AGEI RAIWALA
2020_MES_388622_2
86299/Rwl/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE I RAIWALA
class E cat b(ii)
7 documents required · 7 mandatory
₹500
Yes
₹40,000
Yes
24 Feb 2021
14 Jan 2021
3 Feb 2021
14 Jan 2021
1 Feb 2021
20 Jan 2021
60 days
Amount
Material and labour for pin type, porcelain, vitreous, white, brown or green insulator 11000 volts grade of size 150 mm height, 150 mm dia, including one galvanized mild steel spindle with two galvanized iron washers and one galvanized nut bolt complete all as specified as directed. (Make : Jayshree/Bhel/Pactil
Material and labour for disc type insulator , porcelean vitreous, 145mm high and 255 mm dia ball and socket type, white or brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
Material and labour for loop insulator, vitreous porcelain, white or brown or green, large size, with overall dimension 90 x 140 mm clearance of hole 25.5 mm complete all as specified and directed. Make Jayashree/ BHEL/Pactil.
Supply and fixing in replacement galvanised iron earth wire 4.0 mm dia size for streaching on over head lines as earth continuity conductor including binding at ends with aluminium / steel binding wire at the places where complete all as specified and directed.
Taking up/down old unserviceable U/G cable of 11 KV of size 95 sqmm 3 core removing from trenches and removing old bricks complete all as specified and directedNote:- (i) Excavation ,Returning filling , Removal of surplus soil, sand & PCC cable will be measured in relevant item
Supply, laying, connecting and testing HT UG XLPE insulated screened, PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 95 sqmm , 3 core ISI marked laid in cable,duct / trenches / surface /wall complete all as specified and directed. .
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for poles, laying of electric under ground cable and GI tubing (where provided for protection of cables) and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed.
M&L for fine dry sand cushioning for under ground cable by providing layers of sand 8 cm deep before laying and 15cm deep after laying the cableincluding streching the cable complete all as specified and directed.Note :- Punned (consolidated) thickness of sand will be measured and paid.
M&L for un -reinforced precast concrete cable cover class HVP, type 1 ISI marked with peak , flat of size 300mmx180mm x 40mm as cable protection complete all as specified and directed.
Returning , filling in, any type of soil including spreading, leveling, watering and well ramming in layers n.exc 250mm thick, complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed.
M&L for PCC/ road cutting for laying of pipe/cable exceeding 500 Sqcm & not exc 1000 sqcm in cross sectional area and making good with PCC 1:2:4 type B-1 using 20mm graded stone aggragate, complete all as specified and directed.
M & L for servicing IDMT miscroprocessor based numeric relay (Three nos overcurent and one no earth fault relay) fixed in 11 KV HT panel by primary and secondary injection method and calibration of all the relay and setting the relay tripping timing in advance to match the outgoing load on the incoming and out going feeders complete all as specified and directed Note :(i)Individual Breaker /VCB/RMUs consider as one unit and above job is to be carried out unitwise.Above job wii be carried out by licenced technician as aproved by GE/AGE ( I ). (ii) Any accident/mishapenning occurred during the execution of work shall be responsibity of Contractor.(iii) All necessary tools & plants required for carried out above job will be provided by contractor and the cost of the same deemed to be included in queoted rate.
Supply, install, testing and commissioning of cast resin current transfomer suitable to 11 KV ,indoor type ,150-75/5+5+1, 15 VA burden, accuracy class 5P10, protection class 1 for Differential Protection Relay Make: Crompton/Pragati/Kappa /AREVA/ABB/ Schnider/ Vishal ”
Supply, install, testing and commissioning of microprocessor based numeric feeder protection relay ( over current three nos and earth fault one no)with low set, high set testing, type REF 615 of ABB or equivalent in Schnider/Simense for 11 KV HT panel incl taking down old u/s relay complete all as specified & directed.
M&L for PVC insulated single core, un armoured aluminium conductor of size 35 Sqmm 1100 volt grade of red, yellow, blue and black (phase indication) for jumper connections including taking out U/S Jumper cbale any size complete all as specified and directed.
Supply, installation, commissioning and testing of HT 11 KV outdoor type gang operated triple pole air break switch suitable for verticle mounting fixed type complete with 12 insulators 200 amps rating and steel frame mechanically operated mechanism consinting of operating rod 25mm bore light grade GI pipe of suitable length worked from ground level and with locking arrangement flat iron clamp 50mm x6 mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers as in repair complete all as specified as directed.
Supply ,installation ,testing and commissioning as in repair of lighting arrester metal oxide type, distribution class with all fittings arrangements suitable to 11000 volts grade and discharge capacity 12 KV/10 KA with and including lighting counter and cable of suitable size and core from lightning arrester to lighting counter complete all as specified & directed Make : Jaipuriya brothers/ Crompton/ GEC/ BHEL/ATLAS
M&L for punning of tree, branches touching to electric overhead lines with growth around LT/HT over head lines , poles and stay complete to clear span of 2 mtr all around the OH line , poles with all tools and plants as reuired at site by the contractor including cleaning the area / site ( Note: Any breakdown of line caused during punning shall be made good by the contractor withiut any extra cost ( ii ) Distance between pole to pole shall be measured as one span) (iii) Only those span will be measured in which trees are alives.
Supply only Single phase circuit Spout RYB phase of make ABB/SIEMENS/SCHNIDER suitable for HT VCB 11 KV /RMU, AC 3 Phase, 50 Hz , complete all as specified and directed.
Supply only Single phase bus bar spout for R&B phase of make ABB/SIEMENS/SCHNIDER suitable for HT VCB 11 KV /RMU, AC 3 Phase, 50 Hz , complete all as specified and directed.
Supply only Single phase bus bar spout for Y phase of make ABB/SIEMENS/SCHNIDER suitable for HT VCB 11 KV /RMU, AC 3 Phase, 50 Hz , complete all as specified and directed.
Supply only Copper flexible connection 800 amps capacity suitable for VG 2 VCB trolly of Make ABB/SIEMENS/SCHNIDER
Supply only closing coil operating on 24 Volts DC for VCB trolly of Make ABB/SIEMENS/SCHNIDER
Supply only Tripping coil operating on 24 Volt DC for VCB trolly of Make ABB/SIEMENS/SCHNIDER
Supply only insulator for bus bar support of make ABB/SIEMENS/SCHNIDER suitable for HT VCB 11 KV /RMU, AC 3 Phase, 50 Hz , complete all as specified and directed.
Supply only buffer for opening spring of make ABB/SIEMENS/SCHNIDER suitable for HT VCB 11 KV /RMU, AC 3 Phase, 50 Hz , complete all as specified and directed.
Supply only buffer for closing spring of make ABB/SIEMENS/SCHNIDER suitable for HT VCB 11 KV /RMU, AC 3 Phase, 50 Hz , complete all as specified and directed.
Supply only Auxiliary switch. complete all as specified and directed.
Supply only limit switch. complete all as specified and directed.
Supply only Auxiliary contactor complete all as specified and directed.
Supply only Tripping lever complete all as specified and directed.
Supply only Tripping lever clutch complete all as specified and directed.
Supply only HT fuse wire made out of tinned copper suitable for 11 KV feeder of rating 15 amp
Supply only insulation tape(empire tape) of best quality insulation class A, dry, non adhensive,tensile strength not less than 38 lbs/inch 25mm x 15 mtr ISI Marked
M&L for GI tube light grade laid under road / culvert / drain fixed to pole wall with help of flat iron clamps etc for cable protection for 80mm dia bore complete all as specified and as directed
M&L for cable jointing kit suitable for 11 KV (E) grade cable outdoor end termination, cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed. Make :DENSON/M-seal/Raychem.
S&F in replacement cable jointing kit 11 KV (Earthed) grade cable for straight through cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as specified and directed.
M&L for cross arms,bracings,supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers welding,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including of one primer coat,one under coat and one finishing coat and one finishing coat of paint.
Dismantling air break gang operated switches, vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. complete all as specified and directed
Labour only for Dismantling of old unsv ACSR conductor of any size from HT over head line complete all as directed.
Material and labour for aluminium conductor steel reinforced (ACSR) any size including fixing,streching on poles and proper noseling with bindingwire with insulator of any size as required at site complete all as specified and directed. Make Bharath connductor/Alind.
Material and labour for galvanized stay strand, 7/3.15 mm where directed including dismantling of old unserviceable stay of any size complete all as specified and directed.
Labour only for Dismantling of old unsv stay assembly of any size complete all as directed
Material and labour for stay assembly with all accessories such as stay plate 230mmx230mmx6mm,stay rod 180 cm long 20 mm dia, with nuts and washers including GI bow,turn buckle etc all as per electrical plate No 1 of SSR1991 part 1 (loop type insulator,stay strands, excavation, PCC,will be measured &paid seperately.
Labour only Dismantling/taking down old unsv insulators of any type/size from HT over head line complete all as specified and directed
Material and labour for silica gel medium size, blue in colour of first quality filled in existing transformer including cleaning of breather where directed complete all as specified and directed site.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 Mtr deep below ground level connected by 32 x 6 mm GI strip as earth lead be means of brass nuts and bolt,thimbless, check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x 300mm , 15mm thick plaster in CM 1:4 funnel with wire mesh,RCC pit cover of 320x320x80mm size (1:2:4) type B1 using 20mm graed stone aggregate ,adequate quantity of common salt, charcoal etc all as shown in electrical plate no 3 of MES SSR part-I (2009) and specified including and provision of GI strip up to 7.5 mtr long 40mm dia light grade GI pipe protection and watering pipe of GI 20mm dia bore ,medium grade ,including all excavvation and earth work and connecting the earthing strip to an earthing test point/panel including testing on completion complete all as specified and directed by Engr-in Charge(i) RCC pit cover shall be precast of RCC (1:2:4) type B1 80mm thick reinforced with XPM weighting not less than 4 kg /SQM in lieu of CI cover (ii) Cost of additiona; GI strip more than 7.5 mtr wii be measured and paid separately under relevant item.
M & L for painting of transformer after cleaning the body surface of transformer by rubbing with emery paper to remove oil strains ,dust etc with synthetic enamel paint by spray paint incl writing SM No /MES No of 63 to 200 KVA capacity of transformer to the entire satisfaction of engineer-in- charge . Make of Paint : Berger/Asian/Shalimar
M & L for painting of transformer after cleaning the body surfaceof transformer by rubbing with emery paper to remove oil strains ,dust etc with sythetic enamel paint by spray paint incl writing SM No /MES No 200 KVA to 315 KVA capacity of transformer to the entire satisfaction of engineer-in- charge . Make of Paint : Berger/Asian/Shalimar
M & L for on line heating,filtration and dehydration of transformer oil with dehydration/filtration plant to have dielectric strength not less than 55 KV at 2.5 mm gap complete all as specified as directed by Eng-in-charge. (Any damage occurred to transormer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses)Note :-Arrangement of Power supply through DG Set for filtration plant will be provided by the contractor under the quoted rates.
Material and labour for PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregate for coping of pole and foundation etc, complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 using 40 mm graded mechanically crushed stone aggregate for mass filling in pole pit, coping and foundation etc, complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregate for coping of pole and foundation for fencing post etc,including necessary form work,finished the exposed surfaces fair with out using extra cement including necessary form work complete all as specified and directed.
S & F in repair glavnised strip 32X6 mm buried in ground complete all as specified & directed by Enginee-in-charge.
Supply only Aluminium Lugs 95 sqmm ISI marked suitable for Aluminium UG cable
Supply only insulating minaral transformer oil confirming to IS 335 1993 for replacing in power/distribution transformer with dielctric strength not less than 60 KV at 2.5mm gap complete all as specified and directed.
M&L for replacement of silica gel breather assembly with silica gel for transformer of 63 KVA to 315 KVA transformer complete all as specified and directed.
S& F in repairs of HT bushing with stud, seal etc complete by disconnecting existng LT/HT connection , drain out oil upto required leve of trasformer capacity 63/100/160 KVA l all as specified and directed
S& F in repairs of HT bushing with stud, seal etc complete by disconnecting existng LT/HT connection , drain out oil upto required leve of trasformer capacity 200 to 315 KVA l all as specified and directed
S& F in repairs of LT bushing with stud, seal etc complete by disconnecting existng LT/HT connection , drain out oil upto required leve of trasformer capacity 63/100 KVA l all as specified and directed
Dismantling cross arm of MS channel or angle section etc complete and setting aside within 50m for further disposal complete all as specified and directed.
S& F in repairs of LT bushing with stud, seal etc complete by disconnecting existng LT/HT connection , drain out oil upto required leve of trasformer capacity 160/200/250 KVA l all as specified and directed
S& F in repairs of LT bushing with stud, seal etc complete by disconnecting existng LT/HT connection , drain out oil upto required leve of trasformer capacity 300/315 KVA l all as specified and directed
SHALABH INDIA INDUSTRIES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .