| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹42.8 L+₹1.6 L (3.89%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹43.1 L+₹1.9 L (4.56%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹43.2 L+₹2.0 L (4.84%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L4 | Rejected-Finance Other than lowest | |
| 5 | Rejected-Technical SCO 40 2ND FLOOR OMAXE WORLD STREET SECTOR 79 FARIDABAD FARIDABAD HARYANA 121004 | FARIDABAD | HARYANA | 121004 | - | Rejected-Technical Requisite documents as per NIT not uploaded being an Unenlisted contractor. |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
5 May 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
PROVN OF SOLAR PHOTOVOLTAIC PLANT FOR LIGHTING LOAD FOR SIX WATCH TOWER AT NAVAL AIR ENCLAVE AND SPECIAL REPAIR / REPLACEMENT OF BER ACS AND WATER COOLERS AT NAE AND INS DWARKA OKHA UNDER GE NAVY PORBANDAR
2022_MES_517198_1
9114/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Navy
₹70,000
Yes
31 May 2022
8 Apr 2022
7 May 2022
8 Apr 2022
5 May 2022
22 Apr 2022
8 Apr 2022 - 21 Apr 2022
Amount
Supply installation,commissioning and testing solar roof top grid system (with battery) of capacity 1.5 KW comprising of the following :- (a) Polycrystalline Photovoltaic Module of 330-340 Wp Each. The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards. Crystalline Silicon Solar Cell Modules IEC 61215. In addition, the modules must conform to IEC 61730 Part-1 - requirements for construction & Part-2 requirements for testing, for safety qualification or equivalent IS. I-V curve of module at STC should be provided by bidder. The total solar PV array capacity should not be less than allocated capacity (kWp).The module frame shall be made of corrosion resistant materials silver anodized aluminum alloy. The contractor shall carefully design & accommodate requisite numbers of the modules to achieve the rated power. The module junction box should not be less than IP67 protection. The manufacturer should warrant the Solar Module(s) to be free from the defects and/or failures specified below for a period not less than ten(10) years from the date of sale to the original customer complete all as specified and directed.
(i) Solar PV modules -05 Nos capaciy 330 Watt - 340 Watt each. (ii)Off-grid Inverter-01 No of capacity 2.5 KVA. (iii)Tubular battery -02 Nos of capacity 150 AH. (iv) Module mounting structure corrosion resitant silver anodized aluminium alloy. (v) Charge Controller (MPPT) - 01 No (vi) Enclosure-01 No (vii)DC cable as per site requirement (viii)AC Cable as per site requirement Note :- warranty of 05 years for inverter & 25 years for solar panel shall be provided.
Supply and fix Search light with stand arrangement revolving full around 360 Degree & its vertical axis with 15 degree up and down from the horizantal plane using under Deck control arrangement (UDCA) complete lighting based on fully LRF model made of 3mm low Carbon Aluminium alloy with die-cast back housing, The main reflector is in glass with SS side reflector 4mm thick toughened front glass with endless noeprene rubber gasket, focusing arrangement for adjustment of light-beam narrow or spread option, E-40 lamp holder, painted by powder coated paint & finished with special polyurethane weather proof coating for corrosion resistant, seperate control gear/panel suitable for LED based lighting of 250W complete all as specified and directed by Engr-in-charge. Make:- Kalin Engineering works RSL-LRF25G40 or equivalent model of ISI marked make as approved by GE.
Wall mounted fan of 230 Volts, 50 Hz, 1400 rpm, 450mm sweep alongwith louver including all electrical connections complete all as specified and as directed. Make:- Havells model NoV3 450MM (SB) or equivalent model make as specified here-in-before.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls for one light point controlled by one switch complete all as specified and directed.
S & F Switch piano flush type 5/6 Amps single pole one way 230 Volts complete all as specified and directed.
Taking down old U/S Split AC 1.5/2.0 Ton carefully of any make without disturbing the existing surface from its original position and deposit to the MES Store yard or as directed by Engineer-in-Charge.
Taking down old U/S water cooler of any capacity carefully of any make without disturbing the existing from its original location and deposit to the MES store yard or as directed by Engr-in-charge.
Supply, install and testing air cooled split unit air conditioners inverter AC's BEE 5 star rated electric driven single phase, copper tube condensor coil of capacity of 1.5 TR complete with cordless remote control complete all as specified and directed.
Supply, install and testing air cooled split unit air conditioners inverter AC's BEE 5 star rated electric driven single phase, copper tube condensor coil of capacity of 2.0 TR complete with cordless remote control complete all as specified and directed.
Supply and lay PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC's including cutting of floor/opening of hole in wall and making good after laying of pipe etc to match the existing surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for Frame work for split type AC made of MS angles or other sections including welding, rivetting or bolting complete of grade Fe 290. Gde-E-165 complete all as specified and directed.
Supply and fix SPN sheet metal enclosure with 2 pin and earth plug and socket complete with single pole MCB of 20 Amps complete all as specified and directed.
Supply, installation, testing and commissioning of water cooler BEE five star rated partly stainless steel, electric driven single phase having approx storage capacity 80 ltrs and nominal cooling capacity 40 ltrs/hrs complete all as specified.
Supply and fixing 1.5 ton capacity 5 star inverter window AC Dust filter Dehumidfier, Anti bacterial filter, EER-3.55, copper condenser coil complete all as specified and directed by Engr-in-charge.
Supply and fixing 2 ton capacity 5 star inverter window AC Dust filter Dehumidfier, Anti bacterial filter, EER-3.55, copper condenser coil complete all as specified and directed by Engr-in-charge.
Supply and fixing of Voltage stabilizer for AC working range 170-280 V, 12 A complete all as specified and directed by Engr-in-charge. Make:- V-Guard cat No. VS 400 or equivalent model of make specified here-in-before.
Supply and fixing of Voltage stabilizer for AC working range 170-280 V, 15 A complete all as specified and directed by Engr-in-charge. Make:- V-Guard cat No. VS 500 or equivalent model of make specified here-in-before.
BABUBHAI BHIMABHAI PANDAVADRA
SURESH ELECTRICALS
JAY BHARAT METAL SUPPLIERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .