Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L1 | Accepted-AOC L1 | |
| 2 | L2₹48.3 L+₹3.6 L (8.09%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹50.8 L+₹6.1 L (13.7%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
15 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
CERTAIN SANCTIONED WORKS UNDER AGE E/M NO. III.
2022_MES_557980_2
8963/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kochi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹94,000
Yes
6 May 2023
23 Nov 2022
17 Dec 2022
23 Nov 2022
15 Dec 2022
2 Dec 2022
23 Nov 2022 - 1 Dec 2022
Amount
Supply, installation, testing and commissioning of water cooler with purifier ozone based technology cooler stainless steel body cold, hot and normal water output most superior water purification technology ozonisation, based on microprocessor , controlled electronic system industrial model with dispenser to ensure the precise operation 90 Litre/ Hour dispensing capacity and steel storage tank and connecting up including taking down the existing old unserviceable cooler from existing location transporting and depositing to MES store yard complete all as specified and directed.
Material & Labour for sub main wiring with 2 runs of 4 Sqmm PVC insulated multi stranded copper conductor cable with and including PVC conduit with 1 runs of 4 Sqmm cable as earth wire complete all as specified and directed.
Supply & Fix single pole enclosure with a two pin and earth plug and socket with one single pole MCB 20 Amp 240 Volt complete all as specified and directed.
Supply and laying of 20mm outer diameters CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings, fixed on wall/ceiling with all necessary fittings, solvents complete all as specified.
Supply & Fix 32 mm PVC heavy duty flexible hose complete.
Supply & Fix MCB SPN 6-32 A 230V, 10KA C-Curve complete.
Dismantling and taking down split AC including dismantling of copper three core cable connecting MCB boxes, copper piping etc complete making good disturbed surfaces all as specified and as directed
Supply, installation, testing and commissioning of split air conditioning unit 2 TR capacity (Inverter type) with HD filter complete with cordless remote control, minimum 5 star labeled, latest energy efficient model, eco friendly refrigerant gas, 6000 Kcal / Hour, 50 Hz, 240 volts, air cooled condenser with all accessories varied speed including fixing the outdoor unit with suitable site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including suction and discharge copper pipe with refrigerant with nitrile rubber insulation and control cable from indoor to outdoor up to a distance of 3.0 Metres as provided by OEM, Power cabling (Max 3.0 Metres from Isolator/ Enclosure) to unit, first charging of refrigerant gas including cordless remote, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified.
Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity Inverter type complete with cordless remote control, minimum 5 star labeled, latest energy efficient model, eco friendly refrigerant gas, 4500 Kcal / Hr, 50 Hz, 240 volts, air cooled copper condenser with all accessories varied speed including fixing the outdoor unit with suitable stand site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including suction and discharge copper pipes with refrigerant including with nitrile rubber insulation and control cable from indoor to outdoor as required at site, Power cabling from Isolator/ Enclosure to unit, first charging of refrigerant gas, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified.
Supply and fixing copper refrigerant piping of both sizes for suction line 5/8" and 1/4" for discharge including thermal insulation class "o" nitrile rubber insulation density 45- 55 kg/m³, for suction/ discharge line, beyond standard length provided with original units by the manufacturer. Note: 1) This item shall be measured for the quantity used at site for item No. 8 & 9 for beyond the length provided by OEM, along with unit. 2) One run of both 5/8" & 1/4" pipes along with insulation shall be measured as one length.
Dismantling and taking down window AC of any capacity comprising of all connected accessories from existing locations and deposit to MES Store Yard.
Material & Labour for closing the existing opening with brick and cement mortar works at the removed locations of window ACs, plastering, painting as matching to the existing surfaces complete all as specified and as directed.
Material & Labour for sub main wiring with 2 runs of 2.5 Sqmm PVC insulated multi stranded copper conductor cable with and including PVC conduit with 1 runs of 2.5 Sqmm cable as earth wire complete all as specified and directed.
Supply & Fix in repair 3 Core multistranded Copper Conductor PVC insulated sheathed flexible cable of size 2.5Sqmm complete all as directed.
Supply and laying in replacement chiller water pipe line dia 80 MM and fitting made out of MS pipe Heavy Class pipe with all fittings complete with materials along with necessary clamps, vibration isolators and fittings such as tees, bends, etc adequately supported on rigid supports etc. All disturbed surface shall be done making good as per existing surface complete all as specified and as directed Engineer-in-Charge. Note: Any connected works related re-routing of existing chiller piping lines/internal fittings, welding/fabrication works shall be included in quoted rate.
All as per item No 15 but of size 100 mm dia complete all as specified and as directed.
Taking down old unserviceable pipe insulation over chiller pipe line, fixing new thermocol/puff insulation of 25 mm thickness, covered by polythene sheet, wire mesh and covered by cement plastering with proper finishing and insulation shall be closed cell type with compression strength and thermal conductivity suitable for chilled water circulation pipe lines all as per site requirement. The entire insulation shall be tightly covered with 26 gauge aluminium cladding. All disturbed surfaces shall be made good as existing complete all as specified and as directed by Engineer-in-Charge.
Supply, laying in replacement GI pipe line of 125 mm dia medium grade laid in trench/floors/walls including welding, connecting and painting two coat of synthetic enamel paint complete all as specified and directed.
All as per item No 18 but of size 100 mm dia complete.
All as per item No 18 but of size 80 mm dia complete.
Supply and Fix PN 1.6 manual butterfly valve of sizes 125 mm complete all as specified and directed.
All as per item No 21 but of size 100 mm dia complete.
All as per item No 21 but of size 80 mm dia complete.
Supply and Fixing in repair CI 'Y' strainer of size 125 mm dia in condensing/chilled water line complete dia including modification of pipe line for fixing the strainer and replacement of flanges and nuts & bolts, packing etc as per site requirement all as specified and directed by Engineer In charge.
All as per item No 24 but of CI 'Y' strainer of size 100mm complete.
Supply, laying and testing XLPE cable laid in trenches/floors/walls/supports, insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and as directed. Note : (i) Any walls/floors disturbed during executing the work may be done good as per existing and the rate for same deemed to include in the quoted rate.
Supply and fixing in replacement of stainless steel temperature gauge with thermal pipe suitable for 0-120 degree with dial of existing size at site for existing pipe lines of central AC plants as per suitable size and model complete all as specified and directed
Supply and fixing in replacement of stainless steel analogue pressure gauge suitable for range 0-150 Kg/cum for existing pipe lines and plants as per suitable (dia) size and model including bend pipe (Siphon) upto gauge where required at site complete all as specified and directed
Material and labour for leak testing of central AC plant of capacity 20-40 TR including flushing out old moisturised gas and oil and pressuring with nitrogen gas and kept for 24 hrs as per OEM specifications, vacuumising nitrogen and refilling of refrigerant gas complete all as specified and as directed. Note :- 1.Nitrogen and reorient gas will be measured and paid separately. 2.Empty cylinder will returned to contractor after usage.
Supply only Refrigerant Gas R 22 in sealed cylinder complete all as specified and as directed.
Supply only Refrigerant Gas R 134A in sealed cylinder complete all as specified and as directed.
Supply only Nitrogen gas contains 12 PSI of pressure in each cylinder of 6 Cum.
Supply & fixing Thermal Insulation of ducting using class O rated closed cell elastomeric nitrile rubber having density of 40-60 Kg/m3 and thickness of 13 mm thick suitable for coastal area and fire resistant complete all as specified and directed
Supply & Fixing Chilled water sensor with controlling cable as suitable for existing chiller socket/groove in Voltas model 5F Series/Bluestar chiller units units complete all as specified and as directed.
Supply & Fixing Catchall filters for central AC plants of capacity upto 50 TR complete all as specified and as directed.
Supply and fixing in replacement of Microprocessor control panels VLRP type working with 15VAC for Voltas control panels, make for 5F model central AC plant as suitable upto 60 TR and fitting for existing panels. Make: voltas (Soft hard)
Supply and fixing in replacement pressure suction transducer sensor (setra) for 5F model chiller complete all as specified and as directed.
Supply and fixing in replacement Discharge pressure (setra) for 5F model chiller complete all as specified and as directed.
Supply and fixing in replacement oil transducer (setra) for 5F model chiller complete all as specified and as directed.
Material & Labour for servicing of existing CT fan motor of capacity upto 5 HP including disconnecting electric connection, fan blade and opening motor, taking out bearing and re-metalling the bearing housing shaft, replacement of motor bearing of existing size including transportation from existing location to workshop and back, refixing of electrical connections, testing of RPM after repair, balancing of fan, recommissioning complete all as specified and directed by Engineer-in-charge.
Material & Labour for servicing of existing chiller/condenser pump of capacity 7.5 HP after disconnecting electric connection from foundation, removing defective bearing, re-metalling the bearing housing shaft, replacing with new bearings, gland bush, gaskets, gland packing, nut and bolt, air release valve, cooling fan cover and reassemble, refitting and recommissioning including refixing of all electrical connections, testing, painting, base foundation work along with channels/accessories, including transportation to local workshop and back after repair, testing complete all as specified and directed by Engineer-in-charge.
Supply and replacement in repair round type cooling tower sprinkler aluminium with distributer pipe & stay rod suitable for capacity 100 TR as per existing at site complete all as specified and directed.
Supply & Fix in replacement of PVC Fills suitable for cooling tower of capacity upto 100 TR with fine quality as per existing at site complete all as specified and directed by Engineer-in-Charge.
Taking down the unserviceable dual plate check valve, Supply and fix dual plate check valve of size 100 mm dia including replacement of old nuts & bolts, packing modification of flanges if necessary and all as specified and directed.
All as per item No 44 but for size 80mm dia complete all as specified and as directed.
Material & Labour for removal of complete FRP cooling tower including fan CT motor, fills, sprinkler/nozzle, pipes, valves and preparation of damaged surface and apply FRP sheet and suitable chemical solution (min two coat) of required quantity to make it leak proof and complete re-assembling including replacement of old nuts, bolts and washers, fin support structure, fan structure, repair/replacement of drain pot, float valve etc as per site requirement including refixing of all removed items back fitting and painting of entire cooling tower, pipe lines of existing colour, alignment of CT fan and sprinkler/nozzle and make it vibration free smooth functioning and testing all as specified and as directed upto capacity 100 TR.
Supply and fixing plastic mesh heavy duty, mesh size less than 10 mm X 10 mm for cooling tower with proper frame work with necessary fixing arrangements to make good all as specified and as directed by Engineer in charge.
Supply and fixing of cooling tower fan blade upto capacity of 100 TR suitable in existing CT fan hub with suitable length (approx 300mm to 450mm)/as per existing at site and size with aluminium alloy material with necessary nuts, bolts, and washers complete all as specified and directed.
Supply and fixing of water flow /pressure differential switch, 5-15 Amp, complete all as specified and directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode of size 600 mm x 600 mm x 6 mm thick, buried directly and vertically in ground, earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 metre below ground level connected with and including galvanised earth strip of size 32 x 6mm (Up to length of 7.5 Metre strip including) by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia complete all as specified and directed.
Supply and fixing and connecting up Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe as directed/specified for loop earthing etc as required of galvanised iron strip of size 32 x6 mm complete all as specified and directed. Note: This item shall be measured for the quantity used at site after the length of strip 7.5 Metre complete all as specified and as directed.
Supply and fix in repair Pre filter with filtering capacity down to 20 micron including side aluminum beading of 610 x 610 x 45 mm sizes/as per existing at site complete all as specified and directed by Engineer in charge
All as per item No 52 but for side aluminum beading of 610 x 305 x 45 mm sizes.
All as per item No 52 but for side aluminum beading of 500 x 500 x 45 mm sizes.
Material & Labour for painting of central AC plant upto 120 TR for Three chilling units i.e including of compressors, condensers, pumps and motors frames, panel board complete including chiller and condensing water pipe lines with two coats of synthetic enamel spray paint of existing colour after preparation of existing surface of each unit and marking set numbers, SM/MES numbers all as specified and directed.
Material & Labour for Steel structural fabrication works fabricated from structural steel sections including nuts, cable trays, clamps bolts, washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primary coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and fixing of Hard PVC Piping 40 mm up to drain disposal area with suitable size nitrile rubber insulation suitable for chilled water drain pipe complete all as specified and directed.
Taking down AHU puff panel, cooling coil, filters, cooling coil pan and necessary repair to panels to arrest air leak, packing, refixing/replacing of door hinges, handles, gasket complete all as specified and as directed.
Material and labour for leak testing of existing cooling coil of capacity up to 80TR, arresting the leaks of cooling coil by forced pressuring water, brazing works, aligning fins complete all as specified and as directed.
Material and labour for Machine made powder coated supply/return air grills and diffusers of aluminium construction including 18 G GI collar dampers for supply air inlet complete all as recommended by OEM and as directed by Engineer in Charge.
Supply and fixing in repairs ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe and fixed of size 25mm (Minimum weight 25mm - 455 gms) complete all as specified and as directed
Material and Labour for fire dampers (fusible link) with actuator arrangement complete all as specified and as directed
Material & Labour for servicing of existing AHU motor of capacity up to 15 HP including fan after disconnecting electric connection from motor terminal and opening the motor cover, re-metalling the bearing housing shaft, replacing with new bearings of existing size, cleaning , re assembling including transportation from existing location to workshop and back, refixing of electrical connections, testing after repair , refixing of blower belt, alignment with blower with motor structural frame work and complete painting, recommissioning all as specified and directed by Engineer-in-charge.
Material & Labour for taking down AHU blower from the site, replacement of bearings and bearing supports, cleaning the surface and aligning the blades for smooth functioning and refixing after repair, refixing of belt, alignment with motor, recommissioning all as specified and directed by Engineer-in-charge.
Material & Labour for Welding/cutting of MS/GI Pipe/Rail/MS flanges etc at various locations of AC Plants including with all necessary tools and equipments all as specified and directed.
Supply and replace digital Ammeter 1/5A, 3 phase, Class 1 to existing LT Panel including necessary alteration complete all as specified and directed
Supply and replace digital Voltmeter 3 phase, Class 1 to existing LT Panel including necessary alteration complete all as specified and directed
Material & Labour for Checking of existing condition of air ducts making the arrangement of visualization and the process for disinfection for Indoor air quality of AC ducts including plenum box, supply air, return air ducts with robotic camera, compressed air with flipper, HEPA Negative machine, air compressor, various types of air nozzles complete all as specified and as directed
Material & Labour for Sanitization of ducts by using fogging machine, Biocides so as to avoid fungal/Bacterial formation inside the ducts of AHU units/AHU rooms by using with permissible chemicals with suitable equipments complete all as specified and as directed.
Material & Labour for FRP lining two layer coating with adhesive cohesive chemical solution (min two coat) of required quantity to make it leak proof after preparation of damaged surface area in pipe lines/cooling tower to make leak proof complete all as specified and as directed.
Supply, Fabricate and fixing Name index board of AC plant having size of 1.2m x 0.6m x 5mm(LxBxH) thick including writing letters on board as directed by Engineer-In-Charge with 0.25 mm thick white rubber coated vinyl sheet or synthetic vinyl sheet printed with computer/scotch inject printing without door ink and laminated with average .15 mm thick high quality weather protected calendar film (coated/laminated and transparent/mat finish) pasted with chemical on and including polycarbonate PVC weather protected milky white/transparent sheet and finally thorough washed with liquid detergent soap complete board to be fixed on wall including cost of all materials used and all as specified and directed. Note: Letter sizes/details shall be taken approval of EIC before the manufacturing the name boards.
Supply, Fabricate and fixing AC Plant layout diagram, showing compressor/motor, condenser, liquid line, discharge/suction line, including all safety valves, cooling tower, from LT Panel to AHU in 3mm thick white Acrylic sheet of size 90cmx 60cm duly fixed on a superior quality plywood board and fixed on wall all as specified and as directed.
Material & Labour for Servicing of electric panel of AC plant including cleaning of the electric panel by blower, tightening of control cable terminations, cable glands, end termination crimping by skilled Electricians and helpers, with necessary Tools & Plant for checking and make good functional complete all as specified and as directed. Note: (i) Minor spares up to 500 Rs per unit shall be included in the above quoted rate
Supply and fix electric shock proof floor mat near electric panel in AC plant of suitable size 2m x 1m of min thickness 10mm complete all as specified and as directed.
Supply and fix poly vinyl chloride floor mat in AC plant after filling the pits in floor (if required) and fixing the mat as per existing surface of suitable size with thickness of 3mm, colour light blue complete fixing materials all as specified and as directed.
Supply and fix in repairs 3 way valve with actuator, sensor and control wiring complete set for controlling chilled water flow inside AHU including necessary accessories to make it functional complete tests of size 65-100mm all as specified and as directed.
Supply and charging, testing of compressor oil superior quality in sealed barrel all as specified and directed.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
AISWARYA ENTERPRISES
N.O. Antony Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .