Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC Being the Lowest | |
| 2 | L2₹9.7 L+₹1.6 L (20.5%)Rejected-AOC | L2 | Rejected-AOC Being the Second Lowest |
Tender Value
Refer Docs
EMD Value
₹26,500
Closing Date
13 Oct 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Secretary
Kerala Khadi and Village Indusries Board, Vanchiyoor, Thiruvananthapuram-695035
Maintenance of Existing Workshed at Vattiyoorkkavu in Thiruvananthapuram Dist
2022_KKVIB_511667_1
KB.7494/2022/Engg
Open Tender
Civil Works - Others
Item Rate
60 days
Vattiyoorkkavu
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,300
Yes
₹26,500
Yes
8 Dec 2022
29 Sept 2022
15 Oct 2022
29 Sept 2022
13 Oct 2022
29 Sept 2022
Amount
APPENDIX-A
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. ( D S R 2018 , 2.31. )
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in Charge Nominal concrete 1:4:8 or leaner mix (i/c equivalent design Mix ) ( D S R 2018 , 15.2.2. )
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar ( D S R 2018 , 15.7.4 )
Dismantling doors, windows and clerestory windows (steel or wood) shutter including Chowkhats, architrave, hold fasts etc complete and stacking within 50 metres lead Of area 3 sq. metres and below ( D S R 2018 , 15.12.1. )
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead. Of sectional area 40 square centimetres and above (2018 D S R , 15.14.1. )
Dismantling steel work in built up sections in angles, tees, flats and channels including all guzzet plates, bolts nuts, cutting rivets, welding, etc. including dismembering and stacking within 50 metres lead ( 2018 D S R , 15.18. )
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos sheet ( D S R 2018 , 15.28.2 )
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. ( D S R 2018, 15.56 )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). ( 2018 D S R, 4.1.5 )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) ( 2018 D S R 4.1.10 )
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete ( Observed Data Buildings 50.6.2.2. )
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) ( D S R 2018, 13.4.1. )
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) ( D S R 2018 , 13.7.1 )
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 course sand). ( D S R 14.1.2. )
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer ( 2018 D S R, 13.43.1 )
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work ( D S R 2018 , 13.52.1 )
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. ( 2018 D S R , 13.61.1 . )
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete . ( 2018 D S R , 13.88 )
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : One or more coats on old work ( 2018 D S R 13.98.1 )
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. ( 2018 D S R, 13.99.1 )
Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface ( 2018 D S R 13.111.1 )
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. ( 2018 D S R , 8.31 )
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. ( DS R 2018, 11.37 )
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M. S. ANGLES 40X40X6 mm for diagonal braces and central cross piece. ( D S R 10.5.2 )
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes ( D S R 10.16.1 )
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35 x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. ( D S R 10.31 )
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls, cutting masonry for cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1 : 3 : 6 ( 1 Cement : 3 Course Sand : 6 Graded Stone Aggregate 20 mm nominal size ), Painting two coats of approved wood preservative to sides of Chowkhats and making good the damages to walls and floors as required complete, includingdisposal of the rubbish to the dumping ground within 50 m lead Door chowkhats ( D S R 14.2.1. )
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required.( OD 51.20 )
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm). ( D S R 12.51.1 )
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 0.1 mm), with wall thickness 2.0mm (0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-charge Extruded section profile size 48x40 mm ( D S R 9.117.1 )
Providing and fixing to Door Frame 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter). ( D S R 9. 118. 1 )
Providing & fixing Poly carbonate corrugated / Plain sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shape ( OD 50.12.2.1. )
Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately) ( APPROVED OBSERVED DATA BUILDINGS 50.12.5.1 )
Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). ( D S R 21.5 )
Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of thickness 4 mm ( D S R 14.6.1 )
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. ( D S R 17.7.2 )
Providing and fixing white vitreous china water closet squatting pan (Indian type) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. ( 17.13.2 . )
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White ( D S R 17. 18.1 )
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia ( D S R 17.28.2.2. )
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms ( D S R 17.73.2 )
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore ( D S R 18.17.1 )
Providing and fixing PTMT bib cock of approved quality and colour 15 mm nominal bore, 122mm long, weighing not less than 99 gms ( D S R 18.54.2 )
Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating ( D S R 18.58.2.1. )
Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms ( D S R 18.63 )
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour - 15 mm nominal bore with 45 cm length ( D S R , 18.74.2. )
Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks ( D S R 2018, 18.76.1 )
Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge ( OD BUILDINGS 50.17.1.1 )
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall ( Observed Data Buildings 50.18.7.3.2. )
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 ( Observed Data Buildings 50.18.8.2.2. )
Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 ( Observed Data Buildings 50.18.9.3.2. )
Providing and fixing PVC pipes includings joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia 10 Kgf/cm2 ( OD BUILDINGS 50.18.9.4.1. )
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2 ( OD BUILDINGS 50.18.9.7.2 )
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 ( OD 50.18.9.9.2. )
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall ( OD BUILDINGS 50.18.9.14.1. )
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall ( OD BUILDINGS 50.18.9.17.2 )
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall ( OD BUILDINGS 50.18.9.19.2 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow ( OD 50.18.9.20.1 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow ( OD 50.18.9.20.2. )
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow ( OD 50.18.9.20.3 )
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee ( Observed Data Buildings 50.18.9.20.5.)
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee ( Observed Data Buildings 50.18.9.20.6. )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl ( Observed Data Buildings 50.18.9.20.7. )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow ( Observed Data Buildings 50.18.9.22.1. )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 " Elbow ( Observed Data Buildings 50.18.9.22.2. )
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes , including jointing with PVC solvent cement - 110 mm dia Door Elbow ( Observed Data Buildings 50.18.9.22.3. )
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia tee ( Observed Data Buildings 50.18.9.22.5. )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Door Tee ( Observed Data Buildings 50.18.9.22.6 )
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl ( Observed Data Buildings 50.18.9.22.8 )
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling ( OD . 50.18.9.22.11 )
Supply and Fixing Mirror of Good Quality ( 600 x 450 mm )
Supply and Fixing P V C Floor Trap 110 mm with Necessary cutting of Concrete or Masonry and making Good the Same
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 ( D S R 19.30.1.1. )
Engaging Labour For Cleaning works / Repair Works Beldar ( D S R 0115 )
Engaging Labour For Maintenance works / Repair Works Fitter Gr II ( D S R 0116 )
Engaging Labour For Maintenance works / Repair Works ELECTRITIAN
Engaging Labour For Cleaning works / Repair Works Carpenter ( D S R 0112 )
Engaging Labour For Maintenance works / Repair Works Plumber
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. ( D S R ELECTRICAL 1.10.1 )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 MM ( DSR ELECTRICAL 1.21.1 )
Supplying and fixing PVC batten/ angle holder including connection etc. as required. ( D S R ELECTRICAL 1. 58 )
SUPPLY AND FIXING 12 W LED LAMP ( BULB ) OF APPROVED BRAND ( CROMPTON, BAJAJ, ORIENT OR Equivalent )
Supply and Fixing 9 W LED LAMP ( BULB ) Of Approved Brand ( CCROMPTON, BAJAJ, ORIENT OR EQUIVALENT
SUPPLY AND FIXING 250 MM EXHAUST FAN WITH NECESSARY FITTINGS OF APPROVED BRAND
SUPPLY AND FIXING 1200 MM BATTEN LED LIGHT 20 WATTS WITH ALL NECESSARY FITTINGS ( od15443/2021_2022 )
Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. ( OD ELECTRICALS 90.4.2 )
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C ( OD ELECTRICAL 90.4.5.2. )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm ( D S R ELECTRICAL 1.17.3 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm ( D S R ELECTRICAL 1.17.12 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm ( D S R ELECTRICAL 1.17.21 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch ( D S R ELECTRICAL 1.24.1 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch ( D S R ELECTRICAL 1.24.3 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet ( D S R ELECTRICAL 1.24.4 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet ( D S R ELECTRICAL 1.24.5 )
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. ( D S R ELECTRICAL 1.25 )
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. ( D S R ELECTRICAL 1.26 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) ( D S R ELECTRICAL 1.27.1 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm) ( D S R ELECTRICAL 1.27.3 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 12 Module (200 MmX150 Mm) ( D S R ELECTRICAL 1.27.6 )
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 Way Double Door ( DSR 2.3.3. )
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole ( D S R ELECTRICAL 2.10.1 )
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required ( D S R ELECTRICAL 2.11 )
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( 40 Amps ) ( D S R 2.12. 1 )
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps ( D S R ELECTRICAL 2.14.2. )
Gireesh. R
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .