| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.4 LAccepted-AOC | 1 | Accepted-AOC All documents found in order as per NIT approved by CTA | |
| 2 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-As approved by CTA due to Debarred from CPWD |
Tender Value
₹29.7 L
EMD Value
₹59,349
Closing Date
18 Sept 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
2IC ELECT
FTR HQ BSF GUJ
Replacement of damaged BFL poles with GI octagonal pole along Indo-Pak border in AOR of 123 BN BSF under SHQ BSF Gandhinagar.
2023_BSF_771150_1
9/2IC(Elect)/NIT/FTR-GUJ/2023
Open Tender
Electrical Works
Item Rate
90 days
In border area in AOR of 123 BN BSF
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹59,349
31 Oct 2023
12 Sept 2023
19 Sept 2023
12 Sept 2023
18 Sept 2023
12 Sept 2023
Amount
S.I.T.C. of 10 mtrs. height Hot Dip Galvanised octagonal pole, made of 4 > mm thick sheet , top dia 100 mm , bottom dia 200 mm, complete with Base plate (320 mm x 320 mm x 25 mm), with suitable bracket made of 1300 mm long, 100 x 50 x 6mm GI channel including 3 nos. mounting plates of size 250 x 175 x 5 mm thick suitable for mounting of 3 nos LED flood light fittings, 4 nos 24mm dia. & 750 mm length GI foundation bolts and all other accessories i/c erection on existing civil foundation etc complete as required as per specifications. (Make- Bajaj/Tata/Utkarsh/HIRA RR or as approved by Engg-in-charge
Erection i/c providing and laying in position 1:1.5:3 grade reinforced cement concrete foundation of size 550 mm (L) x 550 mm (W) and 1400 mm (H) with PCC bed and RCC footing (as specified below) i/c grounting of 4 Nos. foundation bolts and providing 65 mm dia PVC heavy gauge pipe for cable entry i/c excavation and refilling, shuttering, steel reinforcement etc. complete as required for 10 mtr pole i/c fixing of bracket on the top of the pole complete as required :-( a) 1750 mm X 1750 mm X 100mm (D) PCC bed of 1:4:8 grade at a depth of 1700 mm below ground level (b) 1550mm X 1550mm X 300mm RCC footing in 1:1.5:3 grade(over the PCC bed).
Supplying & fixing Pole mounting Box ( IP 55 ) made out of 1.6 mm > thick G.I. sheet of size 500 mm x 350 m x 170mm deep having front openable door , locking arrangement, complete with 4 Nos. Al Bus Bar , 1 No. 16 Amp TP MCB , 3 Nos. 6 Amp SP MCB, connectors, connection, interconnection, fixing the box on existing BFL Pole using suitable GI bracket etc complete as required
Supply, Installation , testing and commissioning of set of 3 luminairies with combined wattage 450 watt (Variation of more than +/- 5% would not be allowed) outdoor type LED flood light luminaire having minimum efficency of 100 Lumen/ watt outdoor type LED luminaire light should be of toughened glass & heat sink should be die cast aluminium along with heat sink fins to dissipated heat effectively with adjustable mounting brackets on pole , IP66 & above ,input operation voltage range & frequency 140 to 270 Volt AC at 50 Hz +/- 2Hz , Rated voltage 230 volt AC 50 Hz , PF not less than 0.95, operating teperature range -10 deg C to +45 deg C, working life of LED is minimum 50,000 hrs burninh hrs , open circuit/over voltage protection and external surge protection upto 10kV , CCT 3000+/-500 K ,with all accessories etc as per specification etc . LED light suitable for mounting on the existing pole bracket & drilling of holes as required, making connection with 3 X 1.5 sqmm FRLS grade PVC insulated copper conductor cable from loop box to fitting i/c providing and fixing suitabe size of flexible pipe / insulaiton sleave with accessories from top slot of pole to fitting connections, interconnection and dismentling of existing (3 Nos HPSV) fitting i/c deposite at BFL source BOP etc.as per specification complete required .
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, three core cable in the existing surface/ recessed steel/ PVC conduit as required. A) 3 x 1.5 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed I XLPE aluminium conductor cable of 1.1 kV grade as required. Make- Jainsons/VIB/ Dowells 3.5 x 35 sqmm
Earthing with GI earth pipe 4.5 mtr. Long 40mm dia including accessories & providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with out charcoal / coke and salt as reqd.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .