Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC JAGAHARIMURA AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L1 | Accepted-AOC accepted | |
| 2 | L2₹40.8 L+₹24,838.76 (0.61%)Rejected-Finance DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | L2 | Rejected-Finance L2 not accepted by the committee | |
| 3 | L3₹44.0 L+₹3.4 L (8.50%)Rejected-Finance AMTALI WEST TRIPURA AMTALI NH 08 NEAR AMTALI H S SCHOOL AMTALI WEST TRIPURA WEST TRIPURA TRIPURA 799130 | WEST TRIPURA | TRIPURA | 799130 | L3 | Rejected-Finance L3 not accepted by the committee | |
| 4 | L4₹53.7 L+₹13.2 L (32.6%)Rejected-Finance JATANBARI KARBOK GOMATI TRIPURA | L4 | Rejected-Finance L4 not accepted by the committee | |
| 5 | Rejected-Technical SHIBNAGAR AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799001 | - | Rejected-Technical Non responssive |
Tender Value
₹62.8 L
EMD Value
₹1.3 L
Closing Date
9 Dec 2024, 5:30 pmClosed
DGM,ED-II
ED-II,Bardowali
Shifting of HT Line for widening and strengthening of existing road from NH08 Sekerkote to IOCL Depot Sekerkote within the jurisdiction of ESD-Sekerkote
2024_POWER_55376_1
DGM/ED-II/ 2024-25 / 04
Open Tender
Electrical Works
Item Wise
120 days
Sekerkote
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,540
₹1.3 L
EC-I,Agartala
20 Jan 2025
2 Dec 2024
10 Dec 2024
2 Dec 2024
9 Dec 2024
4 Dec 2024
3 Dec 2024 - 5 Dec 2024
6 Dec 2024
Amount
(Supply & Erection)
Supply of 3-Phase,3-core 6.35/11 KV,120 Sqmm XLPE (EXT.FR-LSH) insulated & insulation screened Aluminium Power Cable conductor as per IS: 7098/II/1985
Providing of Pre-cast cement concretecable identification route marker (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed "DANGERS: TSECL, ELECTRIC POWER CABLE" with Black colour letter(both side). The visible part shall be painted with Yellow colour japan paint. (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits.
Supply of bi-metalic Lugs 120 Sqmm
Supply of GI Stay Clamp 50X6mm
Supply of GI Bracket Clamp 50X6mm
Supply of HDPE Pipe PE 100 grade 110 mm outer Dia 6 mtr Long
Supplying and Making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :Up to 150sqmm
Earthing with G.I pipe 2.5mtr Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing including supply of G.I.Pipe, Salt & Charcoal, GI wire, nuts &bolts, etc. as required)
Grouting of steel tubuler poles /stay set with CC of ratio 1:2:4(1 cement : 2 river sand : 4 Jhama brick aggregate of 20 mm nominal size)i/c supply of cement,sandand brick aggregate20 mm nominal size complete with excavation, refilling of earth ,ramming alonf with centeringand shutteringaas required @ 0.273 cum per Steel tubuler pole & & 0.119 cum/stay sets per TSECL specification,9 mtr long S.T Pole(0.273X25=6.825 cum)
Erection of 11.0 mtrs length of S/T POLE at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with with soil upto the ground level, ramming and making complete in all respect.
Erection of painted Stay set direct in earth complete with 19mmx1800 mm long stay rod, anchor plate of size 300 X 300 X 8 mm. thick, turn buckle of length 356 mm. with 300 mm. long threaded adjustable 16 mm. dia. MS rod , thimble, guy insulator as per IS specification, hot dip (heavy duty) galvanized stay stranded wire of size 7/2.5 mm. fastened with stay clamps as required.
Laying & Stringing of 1km (Single Conductor) ACSR 6/1/2.59 mm dia 'WEASEL' including hoisting & binding etc. Complete as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Trench Size: Width-350mm, Hieght-1200mm / Sand(couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks,Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of all size in the GI Pipe / HDPE for riser including tieup of Pipe with pole by the help MS Flat Clamp (excluding cost of Clamp and Nut&Bolts) as required Up to 400 sq. mm including coiling of excess cable on pole top.
Manually digging /drilling horizontally or diagonali direction for road crossing / Water supply line/Telcomunication line/Gas Pipe line etc. including Laying of 64 to 200mm dia GI pipe direct into the earth at a depth of minimum 1100mm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engineering In Charge.
Laying & strining of 1km (Single Conductor) , 8 SWG GI wire including hoisting & binding etc. Complete as required.
Erection of 11KV protective Guarding by GI wire 8 SWG as per technical specification,across road/River/ Telecom line etc. in horizonta formation complete .
Erection of 11KV Pin insulator along with Pin
Erection of 11KV Single Disc insulator set along with necessary fittings.
Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification. (Excluding the cost of back clamp,Nuts & Bolts)
Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification.(Excluding the cost of back clamp,Nuts & Bolts)
Erection of 9KV,5KA single pole metal oxide gapless type LA , including necessary connection complete as per technical specification.
Erection of M.S.Channel Cross-Arm,1.3 to 2.8 mtr Long75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,0.3 to 1.2 mtr Long75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm,1.0 to 2.5 mtr Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Febrication of Cross-Arms by MS Channel/MS Angle as per specification
Dismantalling of 11 mtr long Steel Tubular Pole
Dismantalling of 9 mtr long Steel Tubular Pole
Dismantalling of MS Stay set Complete
Dismantalling of ACSR (6/1/2.59 mm dia) weasel conductor
Dismantalling of M.S.Angle Cross-Arm,1.0 to 1.6 mtr Long 65 x65 x 6 mm
Dismantalling of M.S.Channel Cross-Arm,0.3 to 1.6 mtr Long75 x40 x 40 x 6 mm
Dismantalling of M.S.Channel Cross-Arm,2.2 to 2.8 mtr Long75 x40 x 40 x 6 mm
Dismantalling of "V" Cross-Arm,65 x65 x 6 mm MS Angle/75 x 40 x40 x6mm MS Channel
Dismantalling of 11KV DOF unit set of three nos. including necessary connections .
Dismantalling of 11KV 200 Amp. GOS unit set of three nos. including necessary connection .
Dismantalling of 11 KV Polymer composite 45 KN Disc Insulator
Dismantalling of 11 KV Polymer Pin Insulator
ADHIR DEBNATH (BID ID -158951)
Bipul Roy (BID ID -159206)
RATAN PAUL (BID ID -158952)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .