Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹11.7 L+₹40,170 (3.55%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹12.5 L+₹1.2 L (10.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹13.1 L+₹1.8 L (15.6%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹13.4 L+₹2.0 L (18.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹28,800
Closing Date
5 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA J AND K
SPL REPAIR FOR REPLACEMENT OF BER MOTOR INCLUDING CONNECTED ITEMS AT MIL STN SAMBA UNDER GE SAMBA
2021_MES_458835_1
GE/SMB/T-25/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹28,800
Yes
27 Aug 2021
12 Jul 2021
7 Aug 2021
12 Jul 2021
5 Aug 2021
27 Jul 2021
12 Jul 2021 - 14 Jul 2021
60 days
Amount
Supply, installation, testing and commissioning of electric driven centrifugal pump set having capacity not less than 1600 LPM at 80 mtrs head ( suction head-10 mtr and 70 mtr discharge head ) comprising of horizontal multistage pump of CI body with bronze impellers, stainless steel shaft, operating at 1475 RPM coupled through a flexible coupling to a TEFC Electric motor, 1475 RPM, 3 phase, 415V, 50Hz complete with and mounted on common MS base frame and foundations of the pump set including PCC foundation, MS bolts with nuts and anti vibration pads, with pressure gauge, complete all as specified and directed.
Taking up and down old unserviceable /rusted/broken GI/CI/DI pipe line of any size from the ground /trenches/wall including connected fittings complete all as specified and directed.
GI pipe of size 125 mm bore medium grade in trenches including fittings complete all as specified and directed. Note: All GI fittings bend ,elbow,tee ,nipple, union ,reducer etc inclusive in quoted item rate.
GI pipe of size 150 mm bore medium grade in trenches including fittings complete all as specified and directed. Note: All GI fittings bend ,elbow,tee ,nipple, union ,reducer etc inclusive in quoted item rate.
Cast iron sluice valve 125 mm bore with both end flanged with iron wheel handle for clockwise closing brass spindle heavy duty PN-1.6 class conforming to IS-14846/2000 including gaskit joint, nuts, bolts & washers including dismantling and taking out existing unserviceable sluice valves, complete all as specified and directed.
Cast iron sluice valve 150 mm bore with both end flanged with iron wheel handle for clockwise closing brass spindle heavy duty PN-1.6 class conforming to IS-14846/2000 including gaskit joint, nuts, bolts & washers including dismantling and taking out existing unserviceable sluice valves, complete all as specified and directed.
Cast iron non return valve 125 mm bore conforming to IS-5312 with Gun metal seating single door type gasket joints bolts/nuts etc including taking out unserviceable non return valves, complete all as specified and directed.
Cast iron non return valve 150 mm bore conforming to IS-5312 with Gun metal seating single door type gasket joints bolts/nuts etc including taking out unserviceable non return valves, complete all as specified and directed.
Supply, installation, testing and commissioning to LT Panel Board, indoor type of suitable size as per relevent IS, mounted on angle iron legs of size 40x40x6mm imbedded in PCC 1:2:4 block type B-2 (using 40 mm graded aggregates) at pump house, floor mounting, dust and vermin proof, factory made (CPRI approved), fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase, 415 Volt, 50HZ AC supply, busbar chamber with aluminum busbar of suitable amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable alley ,cable gland with independent plate at bottom and complete panel board painted with powder coating in grey colour all as specified & directed,The panel should be IS/IEC 61439-I- TTA The contractor should submit Test Certificate along with GA drawing for approval before execution of work. The panel shall be comprizing of the following :- (a)MCCB 160 Amps,thermal adjustable and magentic setting having rupturing capacity 36 KA (Ics= 100% Icu) , TP, 415 volts, 50 Hz, along with Extended Ratory handle ,Spreader terminal and phase barrier - 01 No. (b) Soft Starter as per design of motor and pump (c) Contactors, relays, CT timers, for suitable rating having with ON, OFF , Trip Indicating Light, Push Buttons, Digital MFM along with contactor & semiconductor fuses with , Control Fuse etc fitted in Panel board for showing V, I, Hz, Pf Note: (i) Panel shall be a front/rear opening with cable entry from the bottom). (ii) Fixing of LT Panel including addition / alteration to existing surface deemed quoted in rates and complete all as specified and as directed by Engr-in-charge.
CI fittings as per IS for spigot and socketed pipes for water mains / branches lines such as bends(any type radious and angle )tapers any type (straight, bend,increasing,decresing,or double socket etc) tee pieces,single branch ,Y juntion, double branch,cross(all socket ,socket and spigot) collers,caps&plugs, including connecting pieces one end flanged and other socket or spigot and bell mouth pieces suitable for run lead joint, run lead up to 150 mm bore including all welding works complete all as specified and directed.
Cable of size 35 sqmm single core , FRLS unsheated stranded copper conducter as in connections to MCCB,starters, change over switiche etc connection to be made with cable aluminum terminal lugs and GI screws ,complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 25X4 mm by means of nuts bolts,washers,check nuts of GI steel all as shown in electric plate no 5 all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe ,medium grade 40mm and GI watering pipe 20mm ,medium grade with funnel and wire mesh ,40mm thick pre-cast RCC N-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and connected all as specified and as directed.
Foot valve 150 mm dia complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
Vishav Karma Refrigeration and Electric Work
Ashoka Engineers
M/S A K ENGINEERS & CO.
PARGAL CONSTRUCTION CO
Standard engineers
M/S NANCY ENTERPRISES
Jiwan Singh
M/S MALIK CHAND SIRI RAM
M/S SINGHAL ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .