Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | ₹20.8 L Quoted ₹22.7 L | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹24.8 L+₹2.1 L (9.10%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹24.8 L+₹2.1 L (9.10%) | L2 | Rejected-AOC R |
Tender Value
Refer Docs
EMD Value
₹59,000
Closing Date
7 Apr 2021, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
REPAIR AND MAINTENANCE OF CEILING FANS EXHAUST FANS AND GYM EQPT IN NORTH COMPLEX AT IMA DEHRADUN
2021_MES_428915_1
GE/IMA-04/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR of GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹59,000
Yes
19 Apr 2021
8 Mar 2021
9 Apr 2021
9 Mar 2021
7 Apr 2021
23 Mar 2021
Amount
Taking down Ceiling fan 1200/1400mm sweep of any make and set aside in safe custody for rewinding at local workshop and refixing the same as directed.
Taking down exhaust fan/cabin fan/ wall mounted fan of any sweep and set aside in safe custody for rewinding at local workshop and refixing the same as directed.
Rewinding of ceiling fan of any make with super enameled copper wire of same guage as original including necessary varnishing of new winded coil, insulation etc packing rematalling of shaft, cleaning,grecing,reassembling and testing complete all as directed of following sweeps:-
1200 mm sweep ceiling fan
1400 mm sweep ceiling fan
Re-winding of exhaust fan of any make with super enameled copper wire of same gauge as original including necessary varnishing to new winding coil, insulation packing, rematalling of shaft, cleaning, greasing, reassembling and testing comple all as directed for the following sizes:-
250 to 300 mm sweep
350 to 450 mm sweep
Re-winding of cabin fan/table fan of any make with super enameled copper wire of same gauge as original including necessary varnishing to new winding coil, insulation packing, rematalling of shaft, cleaning, greasing, reassembling and testing complete all as directed.
Gun metal bushes as per sample fixed in repair complete all as directed.
Capacitor 2.5 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as directed. Make: Havells/Bajaj/Crompton/Epcos
Capacitor 3.5 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as directed. Make: Havells/Bajaj/Crompton/Epcos
Capacitor 04 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as directed. Make: Havells/Bajaj/Crompton/Epcos
Capacitor 1/1.5 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as directed. Make: Havells/Bajaj/Crompton/Epcos
Ball bearings of ceiling fan of any sweep fixed in repair all as directed of following sizes:-
6201 Make :- NBC/SKF/TATA
6202 Make :- NBC/SKF/TATA
6203 Make :- NBC/SKF/TATA
6204 Make :- NBC/SKF/TATA
Ball bearing of suitable size of exhaust fan 350 to 450mm sweep fixed in repair complete all as directed. Make: NBC/SKF/TATA
Ball bearing of suitable size of exhaust fan 250 to 300 mm sweep fixed in repair complete all as directed. Make: NBC/SKF/TATA
Taking down and Preparation of old painted body and blades of ceiling fan 1200 mm to 1400 mm sweep of any make including cleaning foreign material, filling cavities etc and painted with one coat of synthetic enameled paint by spray painting and marking MES No with paint and hanging as directed.
Taking down and Preparation of old painted body and blades of exhaust fan 300 mm to 450 mm sweep of any make including cleaning foreign material, filling cavities etc and painted with one coat of synthetic enameled paint by spray painting and marking MES No with paint and hanging as directed.
Flexible copper cable of size 23/0.0076 with PVC insulated 2 core twisted 660 volts grade including taking down existing cable complete all as directed. Make : Finolex/Havell's/Plaza/Polycab
Reel insulator of hard rubber of suitable size for ceiling fan fixed in repair complete all as directed.
PVC canopy of the ceiling fan with screw of any size fixed in repair complete all as directed.
Down rod clamp in one piece or two piece with split pin, bolt , nut and washer as per sample complete fixed in repair all as directed.
Fan regulator electronic 100 watts, 5 step type 230 volts AC complete fixed in repair all as directed. Make:- Anchor/Bajaj/Crompton/Havells
Fan regulator electronic lite dimmer type 1000 watt 230 volts AC complete fixed in repair all as directed. Make:- Legrent Cat Part No 572740 & equivalent of Havels/ Anchor/Bajaj/Crompton
Fan regulator modular type, electronic 120 watts, step type, 230 volts as per sample complete fixed in repair all as directed. Make:- Anchor/Bajaj/Crompton/Havells
Nuts, bolts and washer set 10mm dia, 75 mm long as per sample fixed in repair all as directed
Down rod of rigid steel cunduit of 15mm dia 60cm long for hanging fan with two cut in end of one side pipe approx length 1/2" to 2" and two holes for entering flexible cable both side fixed in repair complete all as directed. Make: Jindal/Finolex/MK India/Asian
Down rod of rigid steel cunduit of 15mm dia 90cm long for hanging fan with two cut in end of one side pipe approx length 1/2" to 2" and two holes for entering flexible cable both side fixed in repair complete all as directed. Make: Jindal/Finolex/MK India/Asian
Down rod of rigid steel cunduit of 15mm dia 120cm long for hanging fan with two cut in end of one side pipe approx length 1/2" to 2" and two holes for entering flexible cable both side fixed in repair complete all as directed. Make: Jindal/Finolex/MK India/Asian
MS clamps with 40mmx4mm thick flat iron bent to shape any type having center two holes, nuts & bolts for hanging ceiling fan complete fixed in repair all as directed.
Exhaust fan blade metal/plastic set suitable for 250 to 300mm sweep as per sample fixed in repair complete all as directed.
Exhaust fan/wall mounted fan blade metalic set suitable for 350 to 450mm sweep as per sample fixed in repair complete all as directed.
Taking down ceiling fan and overhauling/servicing, cleaning, greasing, reassembling, hanging and testing of ceiling fan of any sweep 1200mm to 1400mm including cleaning and greasing material complete all as directed.
Taking down exhaust fan and overhauling/servicing, cleaning, greasing, reassembling and testing of Exhaust fans/wall mounted fans of any sweep (i.e. 250mm to 600mm) including cleaning and greasing/replacing any worn out part complete all as directed. Note :- (i) For servicing purpose Machine oil/grease should be used of apprpriate make only duly passed by the Engineer - in-Charge. (ii) replacement of any worn out part like bearing/ bush/shaft will measured & paid separately)
Split pin of suitable size fixed on nuts & bolts complete all as specified and directed
Louvers for exhaust fan of 250 to 300 mm size fixed in repair on wall complete all as directed.
Louvers for exhaust fan of 350 to 450mm size fixed in repair on wall complete all as directed.
Blade screws of suitable size or as per site requirement complete with washer all as directed.
Metal ceiling fan blade suitable for 1200/1400 mm sweep as per sample fixed in repair all as directed.
Shaft suitable for exhaust fan / wall mounted fan / cabin or table fan as per sample complete fixed in repair all as directed.
Shaft suitable for ceiling fan of any type/size as per sample complete fixed in repair all as directed.
Ceiling fan 1200 mm sweep, 230 volts 5h Hz, energy saving model single phase, copper wound motor, five star, pearl white in colour complete with blade, down rod, canopy and connected with ceiling rose etc including taking down existing ceiling fan complete all as specified and directed. Make:- ES50 Premium of Havels & equivalent of Baja/Usha
Exhaust fan 300 mm sweep, 900 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc including taking down existing exhaust fan complete all as specified and directed. Make:- Turbojet SP of Havels and equivalent of Bajaj/Usha.
MCB SP 6 to 32 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed. Make:- Legrand/ABB/Schneider/L&T
MCB SPN 06 to 32 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed. Make:- Legrand/ABB/Schneider/L&T
MCB TPN 63 Amps, 415 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed. Make:- Legrand/ABB/Schneider/L&T
Sub main wiring with two single core PVC insulated unsheathed FRLSH cable 1100 Volt grade, 6.0 Sqmm size with multi stranded copper conductor drawing into conduit in surface/concealed as required including one run single core PVC insulated unsheathed 6 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unserviceable submain wiring complete all as directed. Make of wire : Finolex, Plaza, Havells, Polycab NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Sub main wiring with two single core PVC insulated unsheathed FRLSH cable 1100 Volt grade, 4.0 Sqmm size with multi stranded copper conductor drawing into conduit in surface/concealed as required including one run single core PVC insulated unsheathed 4 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unserviceable submain wiring complete all as directed. Make of wire : Finolex, Plaza, Havells, Polycab NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Sub main wiring with two single core PVC insulated unsheathed FRLSH cable 1100 Volt grade, 2.50 Sqmm size with multi stranded copper conductor drawing into conduit in surface/concealed as required including one run single core PVC insulated unsheathed 2.50 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unserviceable submain wiring complete all as directed. Make of wire : Finolex, Plaza, Havells, Polycab NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Maintenance and servicing of trade mill invertor based drive motor - 03 KW 4 HP Make: Opus Model TX 980 installed at Hoshiyar Singh Gym by means of repairs such as adjustment, oiling, greasing of pullies & sliding belts and replacement of spare parts if any, including testing and commissioning of equipments by qualified techinicians complete all as directed. Note : Spare parts replaced if any shall be measured and paid seperately under relevent item of BOQ as "Supply only".
Supply only following spare parts for trade mill invertor based drive motor of make Opus model TX 980 are as under:- Note :- (i) Fixing & testing element of following item is deemed to be included under BOQ item No 47 above
Supply only new tread mill belt Make- OPUS
Supply only new trade mill motor invertor based 3 KW, 4.0 HP
Supply only new PCB (APS)
Supply only trademill running Board as per existing
Supply only trade Mill Roller of suitable size PCB(APS) for trademil - 4
Taking down unserviceable steel wire rope and supply and fix new steel wire rope 4 mm dia including bull dog grip of ends complete all as directed.
Taking down unserviceable PVC pulley of trademil and supply and fix new PVC pulley as per sample complete all as directed.
Servicing of Strength station by gressing/oiling and allignment including replacement of damage nuts and bolts for looseness tighting and make machine suitable for use complete all as directed.
MCCB, 100 Amps, 4 pole, 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting including taking out existing unserviceable MCCB complete all as specified and directed Make : Legrand, L&T, ABB, Schneider, C&S.
MCCB, 125 Amps, 4 pole, 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having including taking out existing unserviceable MCCB complete all as specified and directed Make : Legrand, L&T, ABB, Schneider, C&S
Surface and wall mounted LED track light fitting 15 W, 230 volts AC, cool white with high power LED cylindro offering various luminous intensity levels from 1500-3500 lumens suitable for 3 circuit 4 wire universal tracks and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting including taking down existing fitting complete all as directed. Make: Havells cat part No. CYLINDROTSS15W857S38DBLK or equivalent in philips/Wipro
Suspended circular type light fitting 36 W LED 230 volts AC, cool white luminaire of size 600 mm dia and 70 mm height and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to ceiling including taking down existing fitting all as directed. Make: Havells cat part No. MONDO600RDP/S36WLED830SPSWH or equivalent in philips/Wipro
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
JS CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .