AE, North East Electrical Sub-Division
Purta Bhawan, Room No. 112 , Salt Lake
Replacement of old split type Air Conditioning Machines by new split type Air Conditioning Machines including SITC of the same for 4 officers Rooms on 2nd 5th and 6th Floor of Vidyasagar Bhawan
2026_WBPWD_5015937_1
WBPWD/AE/NEESD/e-NIQ-06/26-27
Open Tender
ELECTRICAL WORKS ORG
15 days
Vidyasagar Bhawan
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,330
24 Jun 2026
24 Jun 2026
13 Jul 2026
2 Jul 2026
9 Jul 2026
2 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of existing old model both indoor & outdoor units for 1.5/2.0 ton A.C machines with own tools & tackles and Filup with Brick at gap position after dismanteling of Window AC machine as per direction of EIC and Handed over to the Authority. | 4 | Each. | 12 | ₹48 |
| 2 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum)Minimum ISEER - 5.0, BEE level - 4-Star(min)(Make -Mitsubishi Electric/ Mitsubishi Heavy/ O General (R32)As per choice of E.I.C. | 1 | Each. | 12 | ₹12 |
| 2.01 | Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) | 3 | Each. | 12 | ₹36 |
| 3 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc.
as required : (For 4 nos of New AC Machine and 3 Nos of Existing AC Machine)
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm (Make-As per direction of EIC) | 56 | RM | 12 | ₹672 |
| 3.01 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm (Make-As per direction of EIC) | 56 | RM | 12 | ₹672 |
| 4 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. | 60 | RM | 12 | ₹720 |
| 5 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines.
i) 2.5 sqmm, 3/4 core copper cable (FRLS type).[Make:- Polycab/Havells/Gloster/Finolex/KEI/RR Kabel/As per choice of EIC] | 60 | RM | 12 | ₹720 |
| 6 | S & F 19 mm thick, 3ft x 3ft plywood with necessary screw, wooden guthka etc and mending good the damages as per direction of E.I.C. | 4 | Each. | 12 | ₹48 |
| 7 | Cutting The existing iron grill for installation of outdoor unit of AC machine with own tools & tackles as per direction of EIC and Handed over to the Authority. | 3 | Each. | 12 | ₹36 |
| 8 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for AC installation per storey of building per vertical run. | 64 | story/vertical run | 12 | ₹768 |