| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.1 CrAccepted-Finance | ₹1.1 Cr | L-1 | Accepted-Finance Accepted as L-1 bidder |
| 2 | L-2₹1.1 Cr+₹2.6 L (2.30%)Accepted-Finance L 90 164 2ND FLOOR STREET NO 7 MAHIPALPUR EXTENSION SOUTH WEST DELHI DELHI 110037 | NEW DELHI | DELHI | 110037 | ₹1.1 Cr+₹2.6 L (2.30%) | L-2 | Accepted-Finance Accepted as L-2 bidder |
| 3 | L-3₹1.2 Cr+₹10.8 L (9.65%)Accepted-Finance | ₹1.2 Cr+₹10.8 L (9.65%) | L-3 | Accepted-Finance Accepted as L-3 bidder |
| Sl No | Description | Qty | Unit | ASB System L1 | vardhman medicare pvt. ltd. L2 | MDD Medical Systems India Pvt Ltd L3 |
|---|---|---|---|---|---|---|
| 1.00 | Single deck AHU (30% Fresh air & 70% recirculation):-
Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, consisting 30% fresh air intake provisions with aluminium dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (EU-4), fine filter (EU-7) sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 6 row deep Dx air cooled coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope.
UVGI System:- UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHU's for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil.
AHU shall have provision for fixing of reheater and humidifier including space for all the necessary fitting and accessories.
Supply Air Fan Capacity, CFM : 1200
Inline fan outdoor type of capacity 400 CFM to be installed at return duct
Dx Air cooled Load,TR : 07
Total Supply side Static,Pa : 1500 | 1 | Each | 4,95,000 ₹4,95,000 | 2,31,302 ₹2,31,302 Lowest | 3,54,000 ₹3,54,000 |
| 2.00 | Single Deck AHU (30% Fresh air & 70% recirculation):-
Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, consisting 30% fresh air intake provisions with aluminium dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (EU-4), fine filter (EU-7), HEPA filter (H-14), sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 6 row deep Dx air cooled coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope.
UVGI System:- UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHU's for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil.
AHU shall have provision for fixing of reheater and humidifier including space for all the necessary fitting and accessories.
Supply Air Fan Capacity, CFM : 2600
Inline fan outdoor type of capacity 800 CFM to be installed at return duct
Dx Air cooled Cooling Coil Load,TR : 17
Total Supply side Static,Pa : 1500 | 1 | Each | 6,15,000 ₹6,15,000 | 4,02,868 ₹4,02,868 Lowest | 4,72,000 ₹4,72,000 |
| 3.00 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness 0.63 mm complete as required. | 180 | Sqm | 1,200 ₹2,16,000 Lowest | 1,705 ₹3,06,900 | 1,770 ₹3,18,600 |
| 4.00 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness 0.8 mm complete as required. | 96 | Sqm | 1,400 ₹1,34,400 Lowest | 2,085 ₹2,00,160 | 1,888 ₹1,81,248 |
| 5.00 | Supply, installation, testing and commissioning of 0.63 mm aluminium sheet cladding as required complete in all respect with fixing screws etc., for cladding of outside / exposed ducts. | 100 | Sqm | 2,800 ₹2,80,000 | 2,274 ₹2,27,400 Lowest | 2,596 ₹2,59,600 |
| 6.00 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. | 3 | Sqm | 8,500 ₹25,500 Lowest | 15,791 ₹47,373 | 10,030 ₹30,090 |
| 7.00 | Supply, installation, testing and commissioning of air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core | 3 | Sqm | 8,900 ₹26,700 Lowest | 15,791 ₹47,373 | 13,570 ₹40,710 |
| 8.00 | Supply, installation, testing and commissioning of Fresh / Exhaust air intake louvers made from 3" wide (Minimum 3 MM thk) powder coated extruded aluminium @ 1" pitch with proper stiffeners complete with HDPE insect mesh fixed in a removable frame as per approved design. | 1 | Sqm | 6,500 ₹6,500 Lowest | 15,791 ₹15,791 | 12,980 ₹12,980 |
| 9.00 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Fire Damper | 4 | Sqm | 11,650 ₹46,600 Lowest | 18,318 ₹73,272 | 16,520 ₹66,080 |
| 10.00 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Actuator | 4 | Each | 14,000 ₹56,000 | 15,160 ₹60,640 | 10,620 ₹42,480 Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹6.6 L
Closing Date
17 Feb 2026, 3:00 pmClosed
Executive Engineer ACR
AIIMS Rishikesh
Supply, Installation, Testing and Commissioning of HVAC, Electrical and Civil works for Establishment of Burn unit and Modular OT at AIIMS Rishikesh.
2026_IMSR_893522_1
03/EE/ACR/2025-26
Open Tender
Miscellaneous Works
Works
120 days
AIIMS Rishikesh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹6.6 L
AIIMS Rishikesh
6 Mar 2026
12 Jan 2026
18 Feb 2026
12 Jan 2026
17 Feb 2026
12 Jan 2026
27 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Single deck AHU (30% Fresh air & 70% recirculation):-
Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, consisting 30% fresh air intake provisions with aluminium dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (EU-4), fine filter (EU-7) sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 6 row deep Dx air cooled coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope.
UVGI System:- UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHU's for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil.
AHU shall have provision for fixing of reheater and humidifier including space for all the necessary fitting and accessories.
Supply Air Fan Capacity, CFM : 1200
Inline fan outdoor type of capacity 400 CFM to be installed at return duct
Dx Air cooled Load,TR : 07
Total Supply side Static,Pa : 1500 | 1 | Each | - | - |
| 2 | Single Deck AHU (30% Fresh air & 70% recirculation):-
Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, consisting 30% fresh air intake provisions with aluminium dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (EU-4), fine filter (EU-7), HEPA filter (H-14), sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 6 row deep Dx air cooled coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope.
UVGI System:- UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHU's for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil.
AHU shall have provision for fixing of reheater and humidifier including space for all the necessary fitting and accessories.
Supply Air Fan Capacity, CFM : 2600
Inline fan outdoor type of capacity 800 CFM to be installed at return duct
Dx Air cooled Cooling Coil Load,TR : 17
Total Supply side Static,Pa : 1500 | 1 | Each | - | - |
| 3 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness 0.63 mm complete as required. | 180 | Sqm | - | - |
| 4 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness 0.8 mm complete as required. | 96 | Sqm | - | - |
| 5 | Supply, installation, testing and commissioning of 0.63 mm aluminium sheet cladding as required complete in all respect with fixing screws etc., for cladding of outside / exposed ducts. | 100 | Sqm | - | - |
| 6 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. | 3 | Sqm | - | - |
| 7 | Supply, installation, testing and commissioning of air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core | 3 | Sqm | - | - |
| 8 | Supply, installation, testing and commissioning of Fresh / Exhaust air intake louvers made from 3" wide (Minimum 3 MM thk) powder coated extruded aluminium @ 1" pitch with proper stiffeners complete with HDPE insect mesh fixed in a removable frame as per approved design. | 1 | Sqm | - | - |
| 9 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Fire Damper | 4 | Sqm | - | - |
| 10 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Actuator | 4 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.66 MB
BOQ_939173.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .