Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹26.7 L
EMD Value
₹26,662
Closing Date
12 Jan 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE Sundargarh R and B Division, Sundargarh
O/o the SE Sundargarh R and B Division, Sundargarh
Provision of Comprehensive Annual Maintenance for Fire Fighting at MCH Building at DHH , Sundargarh in the District of Sundargarh for the year 2025.26
2025_EICCL_123978_2
Bid Identification No-SE-R AND B-SNG-21 OF 2025-26
Open Tender
Electrical Works
Percentage
365 days
Sundargarh
Please refer Tender documents.
3 documents required · 3 mandatory
₹6,000
₹26,662
Yes
31 Dec 2025
31 Dec 2025
13 Jan 2026
31 Dec 2025
12 Jan 2026
31 Dec 2025
31 Dec 2025 - 8 Jan 2026
Provision of Comprehensive Annual Maintenance for Fire Fighting at MCH Building at DHH , Sundargarh in the District of Sundargarh for the year 2025.26.
Providing and fixing Single headed hydrant having outlet of 63 mm dia (2.1/2”) N.B. hydrant (IS:5290) landing valve in Stainless Steel Morris Pattern instanteous coupling type TAC / LFA approved & ISI certified heavy type hydraulically tested to 1.5 times working pressure with necessary nuts, bolts etc.Make-Newage/Safex/Omex.63 mm Single headed Hydrant with coupling
Providing & fixing 63mm dia RRL hose pipe as per IS 636 TYPE A TAC/ LFA approved of standard length of approved pattern and size including gun metal male and female Coupling duly bound with copper wire etc. complete.Make-Newage/Safex/Omex.63 mm RRL Hose 15mtr.length. With coupling etc
Providing and fixing TAC approved fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (2mm thick) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of size as mentioned in drawing (or as approved by the Architect) to house 15 mtr.x2 nos. hoses. The hose box size is 750 mm x 600 mm x 300 mm.
Supplying & fixing first aid fire hose reel of thermoplast braided suitably reinforced 20 mm size & 30 m standard length with 5 mm tapering branch nozzle, 25mm dia. Pipe to connect to riser with cut off ball valve attachment. Hose to be swinging type wall mounted drum & recessing into hose cabinet to suit location including fixing with lead anchor fasteners & bolts (Including drum and swivel arrangement) etc complete..Make-Newage/Safex/Omex.Hose reel having 30 mtr. Length with drum etc. complete
Supply,Providing, fixing, jointing and testing in position for sprinkler system following "C" class MS pipes conforming to IS:1239 cut to required lengths including all necessary fittings (All fittings shall confirm to IS:1879 (part 1 to 10) and specials such as bends, tees, unions, Reducers, flanges & plugs etc.fixing at wall / ceiling level supported by clamps, hangers (using anchor fastners) etc, as per specification. Threading, jointing, and making proper connections, cutting hole in wall / floor / slab and making good the same. GI pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls / floors slab and sealing the sleeves with glass wool in between and fire sealent compound at either end all as per Consultant / Employers' requirement. All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwise and the supply of the same shall also be included in rates under this head. Make- TATA/JINDAL/SAIL (Note:-The quoted rates of the contractor shall also include the cost of Fire sealant,colouring of pipes as required. Welding of any kind on the galvanised support / hanger shall not be permitted. ) Size-: 25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supply,Providing & fixing Butterfly valve conforming to IS-13095, PN 1.6 (Body : Grey Cast Iron, Shaft : SS, Disc : SG Iron (Rilson coated), Liner : HT - EPDM) (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 15 Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required. 100 mm dia
80 mm dia
65 mm dia
50 mm dia
150 mm dia
NRV conforming to IS 5312 (swing type) or to API 594/598 (dual plate check type) with CI body & brass trim part, PN 1.0 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved Size : 150 mm .make.Make-Zoloto/Audco/Leader
Supply,Installation, Testing & Commissioning of Pendent/upright/sidewall sprinkler
Supply,Installation, Testing & Commissioning Flexible sprinkler hose for connecting pendent sprinkler.Make-HD/Tyco/Viaking.
Providing and fixing Stainless Steel standard branch pipe dia 63 mm inlet with nozzle 20 mm dia outlet conforming to IS : 903, suitable for instantaneous connections to hose coupling etc. as required:.Make-Newage/Safex/Omex.SS Branch Pipe with nozzle
100 mm dial Pressure gauge with Syphon tubing & isolation valvePressure Guage: 0-7 kg/sq.cm.Make-H Guru/G Guru.
Supply, installation testing and commissioning of 25 mm dia ball valve .Make-Kartar/Leader/Zoloto.
Supply, installation testing and commissioning of 15 mm dia ball valve .Make-Kartar/Leader/Zoloto.
Supply, installation testing and commissioning pressure switch assembly with interlocking of pumps .Make-Indfos/Grandfos.
Supply, installation, testing and commissioning of Analogue Addressable multi sensor smoke,heat multi criteria detector with standard base and other accessories as required. The detector shall be UL/EN/FM approved with isolated module inbuilt...Make-Morley by Honeywell/Notifier/Bosch/Edward.
Supplying, installing, testing and commissioning of addressable Manual call point with built in Monitor Module with all accessories complete. The device shall be UL/EN/FM approved..Make-Morley by Honeywell/Notifier/Bosch/Edward.
Supplying, installing, testing and commissioning of addressable Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. The devise shall be UL/EN/FM approved.
Supplying, installing, testing and commissioning of 2C x 1.5 sq. mm, Twisted Pair PVC insulated FRLS Armored Cable with Accessories confirming to IS standards and specifications. The quoted rate shall includes of Acrylic Fire stop Sealant in the opening for cables passing through fire compartment walls of RCC floors, masonry walls to provide up to 2 hours fire rating.
Supplying, installing, testing and commissioning approved make PVC FRLS conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc.Make-AKG/Precision.25 mm dia.
Colouring of total hydrant and sprinker line with po red luxoil colour and red oxide
Servicing,overhauling,checking and freewheeling of fire pumps and Disel engine with required engine oil,coolant,battery ,battery lead,o ring,oil filter and other asseccories as required.
Refilling of ABC 6 kg type fire extinguisher .
Refilling of Co2 4.5 kg type fire extinguisher .
Estimate for provision for seven technical persons(2No. Welder,2 nos. fitter,2 no. Electrician for detection and public addreesing work, and 1 supervisor for day to day Maintainance of Fire Fighting Equipments .7 Nos High skilled Technical person(shift & Supervisor) for 12month.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.54 MB
BOQ_573736.xls
BOQ • 0.26 MB
DTCN2.pdf
Tender Documents • 4.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .