| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹6.9 L+₹1.2 L (20.4%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest | |
| 3 | L3₹7.3 L+₹1.5 L (26.5%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest | |
| 4 | L4₹7.5 L+₹1.8 L (31.4%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest | |
| 5 | L5₹8.0 L+₹2.2 L (38.6%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
10 Jun 2023, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C/O 56 APO
REPAIR/REPLACEMENT OF ELECT WIRING/FITTING AND FIXTURES AT URI AND RAMPUR UNDER GE 969 EWS
2023_MES_597058_1
CANO 969/WS- /2023-24
Open Tender
Civil Works
Item Rate
180 days
URI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹20,000
Yes
20 Jul 2023
20 May 2023
12 Jun 2023
20 May 2023
10 Jun 2023
5 Jun 2023
Amount
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) Complete, incl fittings such as switches, ceiling roses, pendants, regulators, Sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.
(a) One light point/fan point/Ex fan point controlled by one 5 Amps Switch one way
(b) One 3 pin 5 Amp switch socket outlet on independent board
(c) One 3 pin 5 Amp switch socket outlet on same board with accessories
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor.
S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed.
S&F Switch socket combination 2 in1, 5 pin, 5 Amp flush type with gang box type complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15Amp flush type with gang box, universal complete all as specified and as directed.
S&F socket outlet 2 in1, 3 pin, 5 Amps flush type complete all as specified and as directed.
S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size,230 volts, 6 Amps, complete all as specified and as directed.
S&F Decorative ultra slim energy efficient 1x20 W, 230 Volt aluminium LED lighting fixture with high lumen output, environmental friendly, complete all as specified and as directed.
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S&F LED Lamp 12W complete all as specified and as directed.
S&F in repair LED 10W surface Bed/track light complete all as specified and as directed.
S&F 18 W LED 4000K panel round/square type, Slim, compact, auminum die cast edge lit panel, recess/ceiling mounted square/round fixture with opal diffuser and separate electronic driver including connecting cable of suitable size complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F exhaust fan/brisk air fan of size 150mm sweep, non matallic complete all as specified and as directed.
S&F in repairs Bell Push 5 Amp, flush type complete all as specified and as directed.
S&F switch modular single pole one way 6 amp 240 volts, 1 Module. Complete all as specified and as directed.
S&F switch modular single pole one way 16 amp 240 volts,1 Module. Complete all as specified and as directed.
S&F Modular socket 6A - 2/3 pin combined 2 module. Complete all as specified and as directed.
S&F Modular socket 6A /16A- 2/3 pin combined 2 module. Complete all as specified and as directed.
S&F modular fan regulator step type, 120W -2 module. Complete all as specified and as directed.
S&F in repairs Modular Bell Push 6 Amp, One module complete all as specified and as directed.
S&F white cover plate with frame, 4 Moudule for point complete all as specified and as directed.
S&F white cover plate with frame, 6 Moudule for point complete all as specified and as directed.
S&F white cover plate with frame, 8 Moudule for point complete all as specified and as directed.
S&F ceiling rose 3 terminal/PVC/Polycarbonate, isolated body complete all as specified and as directed.
S&F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S&F 40 Watt Warm White LED ultra modern recess mounted luminaire (LxWxH) 595x595x70 environmental friendly, new generation, aesthetically designed, with high brightness complete all as specified and as directed.
S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed.
S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed| position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 12 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed.
S&F in repairs MCB, SPN 63 Amps 240 Volts 'C' curve complete all as specified and as directed.
S&F in repairs MCB, SPN 32 Amps 240 Volts 'C' curve complete all as specified and as directed.
S&F in repairs MCB, SPN 6 to 32 Amps 240 Volts 'C' curve complete all as specified and as directed.
M&L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing capping shall be measured as one RM
S&F 1100 V grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apartincluding 4mm suspension wire one twin core cable flat or circular of size 10 sqmm all as specified and directed
S&F 1100 V grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 16 sqmm all as specified and directed.
Repair and re-fixing, re-assembling the existing ceiling fan in same original position along with cable after rectification of defects such as rewinding of fan with varnishing, fan capacitor, changing fan bearning, including nut, bolts and washers complete all as specified and as directed.
S&F heating element including rubber gasket & washer etc of capacity 1.5 KW suitable for existing make and shape (triangular/round) complete all as specified and as directed.
S&F Thermostat including rubber / PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25/35/ 50 Itrs including taking down existing unserviceable thermostat complete all as specified and as directed.
S&F PVC connecting pipe 18"/24" long with brass adopters for cold/hot water and connecting up with complete for 25 /35 /50 Itrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and directed.
S&F indication lamp for 25/35/50 ltrs capacity Geysers including taking down existing unserviceable indication lamp complete all as specified and as directed.
Servicing of geysers of any capacity by opening of entire geyser and cleaning all the sledges, blockages, dust, providing check nuts etc complete all as specified and as directed.
S&F in replacement internal assembly 6/9 hole as suitable for 25/50 ltrs capacity Geysers including taking down existing unserviceable assembly with rubber gasket and refixing the same after repairing complete all as specified and as directed.
S&F PVC insulated, PVC sheathed cable electric service cables (For Geyser) with stranded copper conductor of size 2.5 sqmm, 3 core, 1100 volts grade. Complete all as specified and as directed.
S&F bottom covers (set of two halves) duly painted made out of Aluminium / MS sheet of 18 SWG suitable for 25/ 35 / 50 Itrs capacity Geysers including taking down existing unserviceable bottom covers complete all as specified and as directed.
S&F replacement of inner tank as per existing size, capacity 25 Ltrs including disconnecting of all connections of existing Geyser and refixing the same after replacement of inner tank complete all as specified and as directed.
S&F replacement of inner tank as per existing size capacity 50 Ltrs including disconnecting of all connections of existing Geyser and refixing the same after replacement of inner tank complete all as specified and as directed.
S&F Plug top 15A 24V complete all as specified and directed.
S&F Plug top 5A 24V complete all as specified and directed.
S&F replacement of Fan capacitor as per existing MFD complete all as specified and directed.
S&F in repair LED 6 Watt 6000 K round panel ceiling down light Ultra slim LED panels with inbuilt driver in PC body. Premium aesthetics with stepped ring bezel complete all as specified and as directed.
S&F in repair LED 15 Watt 6000K, round type ceiling Ultra slim LED panels with inbuilt driver in PC body. Premium aesthetics with stepped ring bezel complete all as specified and as directed.
Note :- Schedule of credit Rs. 22,584.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/S KULBIR SINGH SODHI AND CO
M/s FAYAZ AHAMD WANI AND SONS
M/S ANUSHA ENTERPRISES
M/S S S TRADERS
M/S Khan Hussain & Co.
M/S ESS EMM ENTERPRISES
Javeed And Co
M/S IQ ENTERPRISES
M/S ARTECH BUILDERS AND SUPPLIERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .