Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC | ₹1.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 LRejected-AOC | ₹1.8 L | L2 | Rejected-AOC L2 |
Tender Value
₹1.9 L
EMD Value
₹4,634
Closing Date
6 Jan 2026, 6:00 pmClosed
Assistant Executive Engineer
o/o The Assistant Executive Engineer PWD Electrical Sub Division Chembukavu,Thrissur-20
GENERAL-Electrification work in the Mini Conference Hall at PWD Rest House Thrissur-work-General Electrical Work
2025_PWD_805861_2
ESDT(ET)83/AEE/25-26
Open Tender
Electrical Works
90 days
Thrissur
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
₹4,634
29 Jan 2026
31 Dec 2025
9 Jan 2026
31 Dec 2025
6 Jan 2026
31 Dec 2025
OD135162/2025-2026:Supply and installation of 2 TR single phase wall mounting 5 star rating inverter type split air conditioner unit fitted with hermetically sealed compressor, operation on refrigerant R32/410gas/Non CFC Suitable for wall/floor mounting conforming to IS 1391 (part II) (amendments - I except Power consumption norms) suitable for operation on 230 V, 50 HZ Single phase AC Supply of performing.:- a. Cooling b. Dehumuidifying.c. Air Circulating.d. Filtering.e. Higher Energy Efficient.:-2 TR single phase split AC unit including copper pipe connection up to 3mtr, electric cabling from out door to indoor unit up to 5 meter,drain piping up to 3 mtr complete. with condenser stand,micro processor control with chordless remote etc. with Manufacturer Warranty:1 year on product, minimum 2 years on PCB, 10 years on compressor year and 4 nos free service for te first year. ( Mitsubhishi/Dikin/Bluestar/O general)
OD135159/2025-2026:Supply and fixing 5 KVA voltage stabilizer V guard or equivalent with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cutt off) time delay, indicators, and chord wire etc.as required.
OD135160/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD135167/2025-2026:Supply and fixing of PVC Casing and Caping on surface / recess of the following size. 25*16 mm.
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
OD135161/2025-2026:Supply and providing 25mm/nearest size pipe complete with standard accessories as drain pipe etc. as required.
OD135163/2025-2026:Supply and fixing company made bracket of suitable size to the out door unit of Single phase 2TR/1TR high wall mega split A/C
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD135252/2025-2026:Supply, conveyance, installation, testing, and commissioning of recess-mounted square (1X1) fitting with high energy efficiency, made of CRCA powder coated sheet .5mm thick with driver with frame, system wattage maximum of 18W, lumen output minimum of 1800lm, power factor>.90, CRI>80, THD <10% with frame.fixed to the ceiling using inbuilt clamps and giving connections with the required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
OD136349/2025-2026:Supply installation,testing and commissioning of recessed mounted "2*2" LED luminaire with high transmitive diffuser suitable for indoor spaces the existing false ceiling and duly wired up for 230 V AC supply.Rating 25/36watt:150 lm/W: temp:Make:Philips/wipro or equivalent. Colour: Cool Day White Light.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1382933.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tendernotice_2.pdf
PDF • 0.02 MB
Tendernotice_3.pdf
PDF • 0.17 MB
Tendernotice_4.pdf
PDF • 0.05 MB
Tendernotice_5.pdf
PDF • 0.06 MB
Tendernotice_6.pdf
PDF • 0.27 MB
NIT.pdf
Tender Documents • 0.03 MB
SBD.pdf
Tender Documents • 1.72 MB
BOQ_1382933.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid