Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC D NO 9 2 1 1 VUDA QUATERS PITHAPURAM COLONY VISAKHAPATNAM PIN 530 003 | VISAKHAPATANAM | ANDHRA PRADESH | 530003 | L1 | Accepted-AOC Being Lowest Vendor | |
| 2 | L2₹21.3 L+₹8,399 (0.40%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹23.0 L+₹1.8 L (8.32%)Rejected-Finance 34 10 37 1 GNANAPURAM DAYAS STREET VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹24.0 L+₹2.7 L (12.9%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹24.4 L+₹3.1 L (14.7%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | MVV Prasad L6 | SAI SREENIVASA ENGINEERING L8 | ALPHA ENGINEERING CONSTRUCTIONS L1 | aswitha engineering works L3 | RAHITHI INFRA L2 | M/s SAI GANESH ENGINEERING ENTERPRISES L7 | PNR CONSTRUCTIONS L4 | B.Veerabhadra Rao L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft loose soil all as specified and directed. | 38.4 | CuM | 267 ₹10,252.8 | 275 ₹10,560 | 200 ₹7,680 | 280.48 ₹10,770.61 | 260 ₹9,984 | 189 ₹7,257.6 Lowest | 220 ₹8,448 | 250 ₹9,600 |
| 2.00 | Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft disintegrated rock (considered for road cutting) complete all as specified and directed. | 4 | CuM | 329 ₹1,316 | 415 ₹1,660 | 500 ₹2,000 | 1,127.35 ₹4,509.39 | 980 ₹3,920 | 225 ₹900 Lowest | 250 ₹1,000 | 300 ₹1,200 |
| 3.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed. | 33.16 | CuM | 165 ₹5,471.4 | 80 ₹2,652.8 | 90 ₹2,984.4 | 101.68 ₹3,371.78 | 125 ₹4,145 | 45 ₹1,492.2 Lowest | 75 ₹2,487 | 50 ₹1,658 |
| 4.00 | Removing of excavated material not exc 50M and depositing where directed at a level not exc 1.5M above the starting point all as specified and directed. | 4.24 | CuM | 120 ₹508.8 | 125 ₹530 | 200 ₹848 | 234.21 ₹993.06 | 260 ₹1,102.4 | 72 ₹305.28 Lowest | 110 ₹466.4 | 75 ₹318 |
| 5.00 | M&L for type B1 1:2:4, using 20mm graded stone agregrate for pole coping / road / drain / path against damage due to excavation/laying of cable complete all as specified and directed. | 5 | CuM | 3,500 ₹17,500 | 4,600 ₹23,000 | 3,000 ₹15,000 Lowest | 6,768.62 ₹33,843.11 | 4,400 ₹22,000 | 4,599 ₹22,995 | 5,500 ₹27,500 | 4,000 ₹20,000 |
| 6.00 | Supply and fixing HDPE double wall pipe corugated pipe of size 40 mm dia for cable protection laid in trenches in lieu of sand/brick protection all as specified and directed. | 280 | RM | 250 ₹70,000 | 89 ₹24,920 | 70 ₹19,600 Lowest | 89.33 ₹25,011.9 | 80 ₹22,400 | 126 ₹35,280 | 210 ₹58,800 | 85 ₹23,800 |
| 7.00 | Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 6 Sqmm 3 core and connection complete with aluminium cable lugs incl dismantling taking down unsv one all as specified and directed. | 200 | RM | 220 ₹44,000 | 126 ₹25,200 | 100 ₹20,000 | 120.61 ₹24,123 | 134 ₹26,800 | 117 ₹23,400 | 99 ₹19,800 Lowest | 115 ₹23,000 |
| 8.00 | All as per ser No. 7.00 above, but of size 16 Sqmm 4 core | 180 | RM | 260 ₹46,800 | 198 ₹35,640 | 160 ₹28,800 | 157.16 ₹28,289.7 | 161 ₹28,980 | 144 ₹25,920 Lowest | 155 ₹27,900 | 191 ₹34,380 |
| 9.00 | Attending electrical complaints and call on repair of control panel of street light, security light, garden light, perimeter light, tower light & high mast light provided inside Dockyard, decarbonizing all contact points of contactors , replacement of wornout aluminium cable lugs, wornout screws, nuts, bolts and washers, tightening the loose connections whereever required, adjustment of timer, cleaning and restore the power supply all as directed.
Note :
(i) Replacement of spares viz MCB, MCCB, contactors, timers, cables, will be measured and paid for separately as supply only and labour element for taking down the replaced spares shall be deemed to include in the unit rate quoted. | 180 | Each Job | 270 ₹48,600 | 180 ₹32,400 | 100 ₹18,000 Lowest | 182.75 ₹32,895 | 260 ₹46,800 | 1,449 ₹2,60,820 | 285 ₹51,300 | 400 ₹72,000 |
| 9.01(ii) If the qty of complaints to be attended in a control panel/LT panel is more than 01 No in a day, altogether the complaints will be considered only 1 (one). (iii) The contractor has to engage qualified electricians and helpers in sufficient Nos to attend and rectify the defects within 2 hrs from obtaining complaint Via Call or Complaint slip otherwise recovery will be made of double amount. (iv) The contractor has to arrange for manipulator/jenny/ladder to carry out repair work and trimming of tree branches which might obstruct in repair work. | |||||||||||
Tender Value
₹32.2 L
EMD Value
₹64,460
Closing Date
19 Jun 2024, 5:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
REPAIR, MAINTENANCE, REPLACEMENT OF GARDEN LIGHT FITTINGS, CABLES AND ALLIED WORKS AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) DM VISAKHAPATNAM.
2024_MES_656467_1
8050/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM, Visakhapatnam
₹64,460
Yes
1 Oct 2026
29 May 2024
21 Jun 2024
29 May 2024
19 Jun 2024
12 Jun 2024
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft loose soil all as specified and directed. | 38.4 | CuM | - | - |
| 2 | Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft disintegrated rock (considered for road cutting) complete all as specified and directed. | 4 | CuM | - | - |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed. | 33.16 | CuM | - | - |
| 4 | Removing of excavated material not exc 50M and depositing where directed at a level not exc 1.5M above the starting point all as specified and directed. | 4.24 | CuM | - | - |
| 5 | M&L for type B1 1:2:4, using 20mm graded stone agregrate for pole coping / road / drain / path against damage due to excavation/laying of cable complete all as specified and directed. | 5 | CuM | - | - |
| 6 | Supply and fixing HDPE double wall pipe corugated pipe of size 40 mm dia for cable protection laid in trenches in lieu of sand/brick protection all as specified and directed. | 280 | RM | - | - |
| 7 | Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 6 Sqmm 3 core and connection complete with aluminium cable lugs incl dismantling taking down unsv one all as specified and directed. | 200 | RM | - | - |
| 8 | All as per ser No. 7.00 above, but of size 16 Sqmm 4 core | 180 | RM | - | - |
| 9 | Attending electrical complaints and call on repair of control panel of street light, security light, garden light, perimeter light, tower light & high mast light provided inside Dockyard, decarbonizing all contact points of contactors , replacement of wornout aluminium cable lugs, wornout screws, nuts, bolts and washers, tightening the loose connections whereever required, adjustment of timer, cleaning and restore the power supply all as directed.
Note :
(i) Replacement of spares viz MCB, MCCB, contactors, timers, cables, will be measured and paid for separately as supply only and labour element for taking down the replaced spares shall be deemed to include in the unit rate quoted. | 180 | Each Job | - | - |
| 9.01 | (ii) If the qty of complaints to be attended in a control panel/LT panel is more than 01 No in a day, altogether the complaints will be considered only 1 (one).
(iii) The contractor has to engage qualified electricians and helpers in sufficient Nos to attend and rectify the defects within 2 hrs from obtaining complaint Via Call or Complaint slip otherwise recovery will be made of double amount.
(iv) The contractor has to arrange for manipulator/jenny/ladder to carry out repair work and trimming of tree branches which might obstruct in repair work. | - | - | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
Tender Document • 0.30 MB
8050corrig1.pdf
Tender Document • 0.25 MB
8050tender.pdf
Tender Document • 0.98 MB
BOQ_734529.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .