Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.0 LAccepted-AOC NO 33 JEENIS ROAD SAIDAPET CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L-1 | Accepted-AOC Awarded to L-1 | |
| 2 | L-2₹16.7 L+₹63,362 (3.95%)Rejected-Finance | L-2 | Rejected-Finance Not being Lowest | |
| 3 | L-3₹17.8 L+₹1.8 L (11.3%)Rejected-Finance | L-3 | Rejected-Finance Not being Lowest | |
| 4 | L-4₹18.4 L+₹2.4 L (14.7%)Rejected-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | L-4 | Rejected-Finance Not being Lowest | |
| 5 | L-5₹23.1 L+₹7.1 L (44.3%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L-5 | Rejected-Finance Not being Lowest |
Tender Value
₹19.5 L
EMD Value
₹39,078
Closing Date
10 Dec 2022, 6:00 pmClosed
Assistant General Manager (E-E)
Assistant General Manager (E-E), AAI, Trichy Airport
Repairing of Fire Alarm System of NITB at Trichy Airport
2022_AAI_135396_1
AAI/TRY/ENGG(E)/ARMO-09/22-23
Open Tender
Electrical Works
Item Rate
90 days
AAI, Trichy Airport
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,180
₹39,078
6 Jan 2023
16 Nov 2022
12 Dec 2022
17 Nov 2022
10 Dec 2022
17 Nov 2022
17 Nov 2022 - 1 Dec 2022
Amount
Supply, Installation, Testing & Commissioning of Graphic User Interface (GUI) / Operator work station consist of desktop PC having Intel Pentium I7 Processor including Serial ports (RS232) and USB ports and following accessories etc. complete with software all as specified): a. 4 Gigabytes of RAM memory b. 2 TB of hard disk space c. DVD ROM d. 21” LED colour monitor e. Mouse with Mouse Pad f. Standard Key Board g. Windows Operating System h. Compatible Fire Alarm System Control Software i. Software for Automatic Fire Detection and Alarm System j. Software for Aspiration Based Smoke Detection System k. UPS 800 VA Note: The system shall be connected to existing fire alarm panel of make "Edwards" model "EST 3"
Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors) Note: The detector shall be suitable for existing fire alarm panel of make "Edwards" model "EST 3"
Supplying, Installing, Testing and Commissioning of UL / EN listed (Latest Version) 120 mtr range Addressable motorized auto align Beam detector with transmitter and reflectors including monitor module with power supply as per specification, complete as required. Note: The detector shall be suitable for existing fire alarm panel of make "Edwards" model "EST 3"
Supplying, Installing, Testing and Commissioning of UL / EN listed (Latest Version) 50 mtr range Addressable motorized auto align Beam detector with transmitter and reflectors as per specification, complete as required. Note: The detector shall be suitable for existing fire alarm panel of make "Edwards" model "EST 3"
Supply, installation, testing and commissioning of UL / EN listed (latest version) Intelligent addressable Control Relay Module with inbuilt fault isolator / isolator module for tripping of AHU & Ventilation / pressurization fans complete with termination etc. complete as required and as per enclosed specifications. Note: The control relay module shall be suitable for existing fire alarm panel of make "Edwards" model "EST 3"
Supply, installation, testing & commissioning of isolator module in fire alarm panel as per specifications. Note: The isolator module shall be suitable for existing fire alarm panel of make "Edwards" model "EST 3"
Supplying & laying of 2 x 1.5 sqmm FRLS armoured cable, 650 / 1100V rated with annealed copper conductor as per applicable IS standard complete as required.
ROYAL PROACTIVE SERVICES
Jaipur Industrial Serives
DElite System Engineering (India) Pvt. Ltd.
GLYPTIC
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .