| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC 31 A K ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | - | Rejected-Technical L2 | |
| 3 | Rejected-Technical JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | Rejected-Technical L3 |
| Sl No | Description | Qty | Unit | R.P.ELECTRONICS L3 | Eastern Commerce L2 | STANDARD ELECTRONICS L1 |
|---|---|---|---|---|---|---|
| 1.00Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity. | ||||||
| 1.01 | 2.0 TR split type high wall AC machine (Minimum rated cooling capacity should be 6000 Kcal/hr or 24000 BThu/hr or 7000 watt). | 7 | No | 60,000 ₹4,20,000 | 56,700 ₹3,96,900 | 55,000 ₹3,85,000 Lowest |
| 2.00 | Standard installation, testing and commissioning of 1.5 / 2.0 TR split including hole cutting, finishing etc. as per direction of the Engineer-in-charge. | 7 | No | 4,000 ₹28,000 | 2,500 ₹17,500 | 2,000 ₹14,000 Lowest |
| 3.00 | Fabrication of M.S platform for placement of condensing unit by using M.S angle of (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. | 7 | No. | 2,000 ₹14,000 | 2,345 ₹16,415 | 1,000 ₹7,000 Lowest |
| 4.00 | Supply, installation of additional length of copper pipe beyond 10 ft. length of appropriate size as suitable for 1.5 / 2.0 TR split AC as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units. | 50 | Mtr. | 1,200 ₹60,000 | 1,800 ₹90,000 | 650 ₹32,500 Lowest |
| 5.00 | Providing hard UPVC pipe of best quality of nominal 3/4 " dia. including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. | 100 | Mtr. | 250 ₹25,000 | 229 ₹22,900 | 100 ₹10,000 Lowest |
Tender Value
₹4.6 L
EMD Value
₹9,204
Closing Date
25 Apr 2025, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division Agartala
Providing Installation and Commissioning of 2 0 TR Split type Air Conditioning system in newly renovated Seminar Room and Library Room at Medicine Building of AGMC and GBP Hospital Agartala
2025_CEPWD_60186_1
109_EE_DNIeT_MECH DIVN_AGT_2024_25
Open Tender
Electrical Works
Works
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹9,204
10 Sept 2025
9 Apr 2025
25 Apr 2025
9 Apr 2025
25 Apr 2025
9 Apr 2025
Amount
Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
2.0 TR split type high wall AC machine (Minimum rated cooling capacity should be 6000 Kcal/hr or 24000 BThu/hr or 7000 watt).
Standard installation, testing and commissioning of 1.5 / 2.0 TR split including hole cutting, finishing etc. as per direction of the Engineer-in-charge.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe beyond 10 ft. length of appropriate size as suitable for 1.5 / 2.0 TR split AC as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units.
Providing hard UPVC pipe of best quality of nominal 3/4 " dia. including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
Eastern Commerce (BID ID -172947)
R.P.ELECTRONICS (BID ID -172934)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_61202.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .