Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹41.0 L+₹5.8 L (16.6%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹41.6 L+₹6.4 L (18.2%)Rejected-AOC HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹42.0 L+₹6.8 L (19.4%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹43.2 L+₹8.0 L (22.7%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹71,000
Closing Date
23 Apr 2022, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVN OF MT SHED FOR MOBILE CRANE AT CGDHQ-01 AND CG JETTY AND ADDITION / ALTERATION FOR IMPROVEMENT OF HYGENIC CONDITION WORK AT VERAVAL UNDER GE I CG PORBANDAR
2022_MES_516380_1
8743
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹71,000
Yes
4 Jun 2022
4 Apr 2022
25 Apr 2022
4 Apr 2022
23 Apr 2022
18 Apr 2022
4 Apr 2022 - 16 Apr 2022
Amount
SCHEDULE 'A'
Excavating in trenches n exc 1.5 m wide & n exc 1.5 m wide and getting out soft/disintegrated rock.
Excavating over areas, n exc 1.5 m deep and getting out soft/disintegrated rock.
Excavating over areas, exc 1.5 n exc 3.0 m deep and getting out soft/disintegrated rock.
Demolition of cement concrete (reinforced) (reinforcement) cut as required to faciliate demolition) of any description and in any position not otherwise specially provided for complete all as specified and as directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation and mass concrete complete all as specified and directed.
M&L Reinforced cement concrete type A1 1:1.5:3 (20 mm graded aggregate) in foundation, footing, foundation beams, plinth beams, base of columns complete all as specified and as directed.
M&L Reinforced cement concrete M-30 (20 mm graded aggregate) Columns, pillars, piers, posts and struts . Complete all as specified and as directed.
M&L Reinforced cement concrete M-30 (20 mm graded aggregate) in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M&L Reinforced cement concrete type A1 1:1.5:3 (20 mm graded aggregate) in slab supported on walls, complete all as specified and as directed.
M&L for Formwork to flat sides with fair finish surface of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter
M&L for Formwork to sides of pillars,posts, struts, piers, columns and stanchions with rough finish surface
Form work to sides and soffits of floor or roof beams, beam haunching,lintel etc.
Form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200 mm thick in sloping.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips.
-ditto- all as per item No. above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders
M&L for broken stone or boulders Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified.
M&L for 100 mm thick Plain Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base of floors all as specified
M & L for 50mm thick Sand filling under floors or in foundation including watering and consolidation
M & L for 80 mm thick M-40 Grade "Manufactured with rubberized mould and surface finished with lacquar", Machine pressed precast concrete paver block of any colour any shape and size confirming to IS 15658-2006 with grey cement and pigment complete all as specified and as directed.
M&L for cement concrete (1:2:4), type B-1, using 20mm graded mechanically crushed stone aggregate as in coping, bed block benching, kerbs, mud stop, rounded or chamferred on edges including necessary form work/moulds complete all as specified and as directed.
M & L Porbandar stone masonry, well bonded, bedded and solidly hearted built in CM 1:6 all as specified and as directed by Engineer-in-charge.
M&L for rendering 10 mm thick on fair face of brick work or concrete surfaces in CM 1:6 finished even and smooth wiithout using extra cement.
M&L for rendering 15 mm thick on fair face of brick work or concrete surfaces in CM 1:4 finished even and smooth wiithout using extra cement.
M&L Rendering on ceiling 5 mm thick in CM 1:3 on brick work or concrete surfaces finished fair and even without using extra cement.
M&L Two coats of OBD on new plastered surfaces of wall over a coat of chalk white primer including preparation of newly plastered surfaces complete all as specified and as directed by Engr-in-Charge.
M&L Two coats of OBD on new plastered surfaces of ceiling over a coat of chalk white primer including preparation of newly plastered surfaces complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of weather proof acrylic exterior emulsion paint over a coat of acrylic primer all as per the manufacturers instructions, complete all as specified and directed by Engr-in-charge.
M&L 18-20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining including 15 mm thick rendering in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture pigements to match the shade of granite all as specified and directed.
Writing letters or figures (Block, Roman, Italic or Indian) exc 30 cm but not exc 45 cm high with stainless steel incl chiselling for letters on granite surfaces.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/disintegrated rock.
Removal of excavated rocks exc. 1.5 Km but n.exc 5 Km and depositing where directed at level n exc. 1.5M above the starting point. all as specified.
M&L 20mm thick cement plaster in cement mortar 1:4 mixed with 2% of water proofing compound as in roof treatment when conc is green complete all as specified and directed.
M&L APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method. (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface.
S & F 1.25mm thick Galvanised rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; eerected in position as indicated, complete; but gear operated type with chain wheel and hand chain etc competed al as specified and directed by Engineer in Charge.
M&L preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of epoxy paint over a coat of red oxide primer etc complete all as specified & directed by Engr-in-Charge.
S&F 300mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars in repair, complete all as specified and as directed by Eng-in-Charge. (NOTE : Excavation and Earth work shall be measured and paid separately)
Supply only internal water proofing compound complete all as specified & directed.
M & L PCC 1:3:6 type C-2 (using 40mm graded stone agg.) for concrete bed to drain pipes 150mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified & directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable ceramic/vitrified tiles to store and rubbish off the premises, complete all as specified and directed.
M&L 25 mm thick cement concrete type B-0, 1:2:4 (20 mm graded aggregate) as in bedding layer of granite floors etc., complete all as specified and as directed.
M&L Non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed of CM 1:6 complete.
Taking down cement plaster on brick or stone walls including racking out joints, hacking for key scrubbing down with water etc., complete all as specified and directed by Engr-in-Charge.
S&F Two piece wall hung EWCs (670 x 390 x 760 mm) including P Trap, soft close seat cover and excluding flushing cistern with twin flush fittings including necessary nut/bolt for fixing, in repairs, colour and model as approved by GE, complete all as specified and directed. Make: CERA CLAIR or equivalent as approved by GE.
S&F 15mm bore CP single lever concealed diverter with lever, turn type knob and 2mm thick sheet metal wall flange and concealed part Faucet, complete all as specified and as directed by Engr-in-Charge. Make CERA (Cat Part No - F1012702 and F4010106 or equivalent.
S&F Wall mixer with telephonic shower arrangement, but without Hand Shower for mixing hot & cold water screwed down for iron/PVC pipe and fixed, complete all as specified and directed. (Make : CERA Product Code : F2010403 or equivalent).
S&F Wall hung wash basin 665 x 545 x 190 mm including cutting for and pinning in ends of brackets or erecting stand including single lever clinical faucet, as in repair, complete all as specified and directed. Make -CERA (Cat. No. S2040159 CRANE Wall hung wash basin) (Cat. No. F9030453 Single lever clinical faucet) or equivalent.
S&F FULL CABINET Set including following accessories complete all as specified and as directed by Engr-in-Charge. (a) Basin : 810 x 775 mm (b) Mirror 500 x700mm (c) Side Cabinet : 240 x 135 x 700 mm (d) Floor Mounted Cabinet 770 x 451 x 680 mm Make - SOMANY (TRIUMPH FULL CABINET SET) or equivalent.
S&F in repairs door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed.
S&F in repair aluminium sliding window shutter of section 38 x20 mm or as exxisting at site including two No roller and one No. aluminium locking arrangement complete all as per manufacturer instruction complete all as specified. (Make : Hindalco/ Jindal or equivalent)
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jamps, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite over screed bed or bedding layer of 15 mm thick 1:6 etc., as in repair, complete all as specified and directed.
S&F as in repair, Wall mounted single lever Basin mixture with valve flange concealed single body complete all as specified and as directed by Engr-in-Charge. Make: CERA Cat Part No. 2013451 or equivalent.
S&F in repair CPVC pipes, 20 mm dia SDR-11, including plain CPVC SDR fittings for Hot/ cold water for sizes mentioned below including all fittings and solvents and special fittings like brass tee, make threaded brass adaptor, female threaded brass adaptor etc., unions, flange and tank adapter all as per manufacturers recommendations, complete all as specified. (Make: Astral/ Ashirwad or equivalent)
S&F Stainless steel toilet Roll Holder with flap, Make : CERA (Cat Part No F5004110) or equivalent, as in repair, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Soap Dish, (Make : CERA Cat Part No. F5001106 or equivalent, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Mood Changer Hand Shower 15 mm bore with 1 meter long easy flex tube in chrome finish and wall hok with NRV (Back Flow Preventer) as approved by the Engr-in-Charge. Make- CERA Cat Part No. F7030311AB or equivalent.
S&F as in repair, ABS body Overhead Self cleaning rain shower 290 x 200 mm (11" x 8"), complete all as specified and directed by Engr-in-Charge. (Make : CERA Cat Part No. F7010513AB or equivalent)
S&F in repairs 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F as in repair, 15mm bore Bib cock pressmatic with aerator and wall flange complete all as specified and as directed by Engr-in-Charge. Make: CERA Cat Part No. F9020151 or equivalent)
S&F 15mm bore long body floor mounted pillar cock with aerator, as in repair, complete all as specified and as directed by Engr-in-Charge in repairs. (Make : CERA Cat Part No F1018101 or equivalent)
S&F Angle cock with wall flange, as in repair, complete all as specified and as directed by Engr-in-Charge. Make : CERA (Cat Part No F1018201 or equivalent.
S&F Concealed stop cock 15 mm bore, cast copper alloy, screwed down, high pressure, fancy type, chromium plated with long shank and cup, etc complete all as specified. Make: CERA Cat Part No. F2002361 or equivalent)
S&F as in repair, Tubular towel rail, 60cm long between flanges, complete all as specified and as directed by Engr-in-Charge. (Make : CERA Cat Part No. F5002103 or equivalent)
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm, complete all as specified and directed.
Taking down chowkhat with shutter (without taking off shutter from frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed
S&F in repair PVC valve less, syphonic action type, flushing cistern 10 ltr capacity, low level white, with inlet, ball valve, float and handle including bracket , PVC bend pipe etc. complete all as specified and as directed by Engr-in-Charge (Make: CERA Cat. No. S1060102 or equivalent)
S&F 12 mm thick Toughned Glass Door with patch fittings with cover plate of SS-304 Grade including Decorative type Stainless steel 304 grade floor Spring, fixing/moving arrangement at top, designer glass handles 2 Nos of 450 MM suitable size as directed, Fin Connect Patch Lock etc in each door, including cutting holes in any size in floor and wall including making opaque with laminate sheets, complete all as specified and as directed by Engineer-in-Charge.
S&F 12 mm thick Toughned Glass as in Partition with patch fittings with cover plate of SS-304 Grade, necessay accessories etc, including cutting holes in any size in floor and wall and making opaque with white laminates on the glass, complete all as specified and as directed by Engr-in-Charge
S&F Gypsum Board 12 mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed.
S&F GI frame work (size of grid 605 x 605 mm) for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre, complete all as specified and directed.
Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified
M&L applying two coat of Oil Bound Distemper over one coat of primer on surfaces of ceiling complete all as specified and as directed
M&L applying two coat of Oil Bound Distemper over one coat of primer on surfaces of wall complete all as specified and as directed
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out any type of excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m., complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D2 (using 40mm graded aggregate) in foundations, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
M & L for 150mm bore RCC pipes class NP2 laid and jointed complete with collars, complete all as specified.
M&L for Cement concrete bed to drain pipes of 150mm dia (1:3:6) type C2 using 40mm graded aggregate including packing under and haunching against sides of pipes after they are laid and tested all as specified and directed.
M&L for Cement concrete 1:2:4, type B1 (using 20mm graded aggregate) in benching for manholes including necessary form work and finishing of exposed surfaces of concrete all as specified and as directed by Engr-in-Charge.
M&L for precast cement concrete (1:2:4) type B1 (using 20mm graded aggregate) as in cover slabs for manholes etc including necessary form work and set in CM 1:4, complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth w/o using extra cement, complete all as specified and directed.
M&L for MS work such as rungs, handles to manholes, etc., complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and directed.
S&F PVC (SWR) Pipe single socket in 75 mm bore, in any length with rubber rings joints laid in trenches or in floors or to walls etc complete
S&F PVC (SWR) Pipe single socket in 110 mm bore, in any length with rubber rings joints laid in trenches or in floors or to walls etc complete
S&F PVC (SWR) gully trap 125/110 mm setting and jointing with solvant cement in repairs etc complete
S & F of Stainless steel 316 bird proof spikes with polycarbonate base of size ( Length of unit= 300 mm, width of base = 45 mm, height of spike = 115 mm ) in Hanger roof truss, rafter and purlins with manufacturar instruction including cleaning and preparation of steel/concrete surface complete all as specified and directed.
Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- Make : Polycab/RR Cables/Finolex
One light /fan point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board .
Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame for modular switches, sockets, switch sockets for one 3 pin 15 or 16 Amps on independent board with required modules all as specified. insulated but unsheathed multistrand copper conductor FRLS cabel 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board as specified. Make : Polycab/RR Cables/Finolex
Supply & fix modular switch 1 way, 6 Amps, 1 modular (ISI marked).complete all as specified and as directed. Make : Legrand/L&T/Anchor
Supply & fix modular switch 1 way, 16 Amps, 1 modular (ISI marked).complete all as specified and as directed. Make : Legrand/L&T/Anchor
Supply & fix modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand/L&T/Anchor
Supply & fix modular switch 1 way2 Modular switch 2 way 6A, 1 module (ISI marked).complete all as specified and as directed Make : Legrand/L&T/Anchor
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand/L&T/Anchor
Supply & fix LED down lighter, recess mounted die cast aluminium downlighter with high trnamission diffuser of 15 Watt 230 volt cct (6500)K complete inclduing connecting flexibal wire connected to connecter of fiiting complete all as specified and as directed Make Model No Helix LD91 of Wipro/Philips/GE
S & F in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make Wipro - CAT PT No- LL20-281-XXX-65AL1** or equivalent to GE/Philips
S&F MCB DB SPN, 6 Way, Double door, IP 43 Protection with connected accessories like insulated busbars, insulated IP2X neutral bars & earth bar, blanking plates, cable management kit all as spd and directed Make Legrend/C& S / L&T
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed Make Legrend/C&S /L&T
SP 5 To 32 AMP
SPN 25/ 32 AMP
S&F DB VTPN, 4Way, Double Door, IP43 protection with connected accessories like insulated bus bars, insulated IP2X neutral bars and earth Bars, blanking plates, cable management kit, incoming as MCCB and outgoing SP/TP MCB all as specified and directed.Make Legrend/C& S L&T
S & F ISI marked MCCB for AC applications till 63 A, having breaking capacity Icn = 10 kA 4Pole sliding bottom clamp, colour coded on/off indication on dolly, biconnect and sliding shutters, all complete as specified and directed. Make Legrand/C&S/L&T
Supply and fixing MCB 25 Amp 4Pole 415 Volt 16 KA complete all as specified and as directed Make Legrend/ ABB/C&S
S&F LED street light 25W, lumen output not less than 2500 lumens high pressure die cast aluminium housing 140/270V, 50Hz, PF>0.90, including 1.2Mtr long 40/50mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of FI 40mmX6mm with bolts,nuts,washers and conductors to fitting with 3 core 1sqmm PVC insulated copper cable from control box to fitting complete all as specified.NOTE:The quoted unit rate deemed include for painting to clamps with one coat of red oxide paint before fixing. Complete all as specified and directed by Engineer-in-Charge.Make:-Wipro/GE/Philips
M&L Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion complete all as specified and directed. Note: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 100mm c/c with suitable cast iro handle shall be provided. (ii) Cost of earth strip and GI pipe for protection of earth strip deemed to be included in unit rate upto 7.5 meter. (iii) IR Value of earthing should be less than 5 ohms. (iv) Charges of boring for pipe earthing by machine is included in the quoted rate.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing as required 4mm dia galvanized iron complete all as specified and as directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil and including taking out of PCC cable cover and getting out complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply and Lay of OD Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches/road/nallah or fixed along wall poles or laid under floor for 38/50 mm Outer dia. Make GEMINI/Polycab/ Rex
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core Make Havells/Polycab/ Finolex.
Supply and laying in treches or fixing on wall light grade GI pipe of 40 mm dia complete all as specified and as directed Make Jindal/ Suryapraksh/ Tata
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil complete all as specified and directed.
V D JADEJA
K B N TRADERS
Nitesh Enterprise
Leo Elevator Company
JAY BHARAT METAL SUPPLIERS
RAJESH ENTERPRISE
shivshakticonstruction
Bidder Name
JAY BHARAT METAL SUPPLIERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .