Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.4 L+₹78,009 (3.05%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹27.3 L+₹1.7 L (6.65%)Rejected-Finance PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹29.0 L+₹3.4 L (13.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹29.2 L+₹3.6 L (14.2%)Rejected-Finance 33 NATIONAL CHAMBERS NEAR CITY GOLD CINEMA ASHRAM ROAD AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹52,000
Closing Date
31 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Yogender Singh
GE (I) Navy Porbandar Tija Mile Porbandar
PROVN OF DRIVER CHANGING ROOM, PAVED AREA IN FRONT OF MAIN SECURITY GATE INS AND AT NAUSENA BAGH PORBANDAR
2020_MES_382018_1
9044/PBR/E8
Open Tender
Civil Works
Item Rate
150 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer (I) Navy
₹52,000
Yes
21 Nov 2020
29 Sept 2020
2 Nov 2020
29 Sept 2020
31 Oct 2020
14 Oct 2020
30 Sept 2020 - 13 Oct 2020
60 days
Amount
Surface dressing not exceeding 15 cm deep in hard and dense soiland getting out complete all as specified. Note:- Area of surface dressing and surface excavation are not payable simultaneously.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth for foundation, etc. and getting out in hard / dense soil, complete all as specified.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth for foundation, etc. and getting out in soft / disintegrated rock complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil, complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/disintegrated rock, complete all as specified.
Removing excavated material soil/rocks exc. 250 m and n. exc. 1.5 km, depositing where directed at a level n. exc. 1.5 m above the starting point, complete all as specified and directed.
Treating the top surface of filled earth with anti termite emulsion at the rate of 5 litres per square metre of surface area,complete all as specified and as directed.
Treating the soil under plinth protection / ramp with anti termite emulsion at the rate of 5 litres per square metre of surface area,complete all as specified and as directed.
PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete or as in sub base (75 mm thick) complete all as specified and directed.
Hard core of broken stone or boulders of guage n exc. 63 mm, deposited, spread and levelled in layeres n exc. 150 mm thick, watered and rammed to a true surface, before concerting or otherwise complete all as specified and directed.
Moorum / red bajri filling in floors or pavings, laid in layers n. exc. 150 mm thick, spread, levelled and well rammed including watering, complete all as specified and directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footing plinth beams, bases for column etc. complete all as specified and directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in Columns, Pillars, Piers, Posts and Struts complete all as specified and directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed .
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in chajjas complete all as specified and directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in roof slab supported on walls, beams and columns in roofs complete all as specified and directed.
Use and waste for form work to chajjas including edges etc, complete all as specified and directed.
Use and waste of Form work to sides of concrete foundations, footings, bases of columns and plinth beams and similar work, complete all as specified and directed .
Use and waste of Form work to sides of columns, square, rectangular, complete all as specified and directed .
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup, ports, overhangs, etc. also splays between floors and beams complete all as specified.
Use and waste of Form work to sides and soffits of suspended slabs such as roof slabs, floor slabs and similar work n exc 200 mm thick (horizontal or sloping) complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Rendering 5 mm thick on fair faces of brick work or concrete surfaces as on ceiling surface, facia and projection of slabs, and window projection, in CM 1:3 finished even and smooth without using extra cement complete all as specified.
Rendering 10 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:6 finished even and smooth without using extra cement complete all as specified.
Mild steel CRS bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Mild steel CRS bars 8mm dia as in stirrups spacer and binder, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Mild steel CRS bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Mild steel conforming to Fe-290, Gde-E-165 framed work as in hold fasts and similar smal;l articles. including necessary cutting, welding, bending, drilling etc, complete all as specified and directed.
Rendering 20 mm thick in two layers (15+5mm) ,on fair faces of stone masonry surfaces or concrete surfaces in cement mortar 1:4 finished even & smooth with out using extra cement including use of water proofing compound in outer layer, complete all as specified and directed. (Note- Water proofing compound shall be measured and paid separately).
Supply only integral water proofing compound.
Non skid ceramic joint free floor tiles 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm set and jointed in neat cement slurry and pointed in coloured cement over and including bedding layer 15 mm thick in cement mortar 1:6 complete all as specified and as directed.
Non skid ceramic joint free floor tiles of 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm as in skirting set and jointed in neat cement slurry and pointed in coloured cement over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed.
Glazed ceramic coloured tiles 300x200x7mm thick as in vertical surfaces such as dado set and jointed in white or coloured cement to match over and including 15mm thick rendering in CM (1:4) complete all as specified and as directed.
Coloured non skid ceramic tiles 7 mm thick (square /rectangular) area of each tile not exceeding 0.11 sqm, as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
75mm thick PCC 1:3:6 , type C-1 using 20mm graded stone aggregate as in plinth protection finished even & smooth without using extra cement making 10mm wide joints at every 3m interval and at every corner, filled with mixture of bitumen and sand (1:1) complete all as specified.
2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Factory made 35mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
Factory made solid panel PVC door shutter, 30mm thick (style consisting of frame made out of MS frame covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip 20 mm wide stuck inside with solvent cement for style and plain colour PVC sheets for top lock rail & bottom rail on either sides and as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet fitted in MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement fixing in the frame at site as per manufacturer's instruction and as specified in SSR Part-II-2010.
Powder coated aluminium anodised frame of size as directed for doors, windows and partitions with one or more rebates including necessary joining cleats, glazing clips, rubber neoprene packing, etc complete with powder coating of approved colour minimum thickness 50 micron complete all as specified and directed.
Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
Aluminium deco grill 5.5 mm to 6.5mm thick with necessary channels and clips design pattern DG 104 complete all as specified.
Aluminium, anodised, barrel tower bolts 200mm long of extruded section and fixed complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 300mm long with fixing clips of sheet, cast or extruded sections fixing bolts and sliding bolts of extruded section or cast-aluminium alloy complete all as specified.
Aluminium handles, cast type, anodised 150mm long , Complete all as specified and directed.
Butt hinges 100mm long medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples, complete all as directed.
Floor door stopper aluminium alloy body double tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified.
4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified.
Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Preparation of newly plasterd surfaces of wall and applying two coat of oil bound distemper over applying one coat of chalk whitening complete all specified and directed.
Preparation of newly plasterd wall surfaces and applying two coats of acrylic emulsion weather proof antifungal paint over a coat of apex primer, complete all specified and directed.
Preparation of new wood and wood based surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pnik primer complete all specified and directed.
Super Acrylic towel rail 20mm dia D type 60 cm long between flanges complete all as specified and as directed.
Vitreous China wash hand basin white flat back, size 550mm x 400mm, cutting for and pinning in ends of brackets Including waste pipe, brass coupling, 32 mm bore chromium plated brackets, restoring all connections complete all as specified.
Pillar tap brass 15mm bore, with capstan head chromium plated fencing type screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe fixed in repairs complete all as specified and directed.
PVC connection 450 mm long, 15mm size with PTMT nuts complete all as specified and directed.
15mm bore bib tap fancy type cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe complete all as specified and directed.
Vitreous China wash down water closet (Pedestal pattern) white with concealed S-Trap/P-trap, 360mm wide, 390mm high and 415 to 445mm long at top including fixing bolt Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device fixed complete all as specified and directed.
PVC low level flushing cistern 10 litres capacity valve less symphonic action type, ISI Marked white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
15mm bore stop valve fancy type cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
Health faucet of high quality with 1mtr long flexible tube and wall hook complete.
PVC (SWR) floor trap, diameter of outlet 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 complete all as specified and directed.
Grating CP 125 mm dia, with centre hole complete all as specified and directed.
75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring, joints laid in trenches or in floor complete all as specified and directed.
110mm bore PVC (SWR) pipes of pressure rating 6 kgf / cm2, single socketed in any length with rubber ring,laid in trenches complete all as specified and directed.
150mm bore PVC (SWR) pipes of pressure rating 7.5 kgf / cm2, single socketed in any length with rubber ring,laid in trenches complete all as specified and directed.
S&F PVC (SWR) 110/75 mm dia junction single T equal or un equal as in floor complete all as specified and directed.
75mm bore PVC (SWR) bends, diminishing pieces or tapers , complete all as specified and directed.
110 mm bore PVC (SWR) bends, diminishing pieces or tapers , complete all as specified and directed.
75 mm bore PVC(SWR) pipes of pressure rating 4 kgf/ cm2 single socketed in any length with rubber ring joints jointing with adhesive fixed to wall/laid in trenches complete all as specified and directed
75mm bore PVC (SWR) vent cowl complete all as specified and directed.
25 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity, hoisted and fixed in position, with lid, , tounge nipple for inlet, outlet connections etc. complete all as directed by Engr-in-Charge.
Gun mental globe or gate valves, with iron wheel head screwed both ends of iron pipes for 20 mm bore pipe fixed Complete all as specified and directed.
20mm bore ball brass valve, high pressure with epoxy coated aluminium rod and high density polythene float ball and fly nut screwed for iron pipe complete all as specified and directed
Pre-cast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab of manholes, septic tanks, etc. and set in cement mortar 1:4 including dismantling of damaged RCC covers slab complete all as specified and as directed. NOTE : Reinforcement will be measured and paid for separately under relevant Item(s).
PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in benching in man hole etc all as specified and directed.
M&L Cutting into existing manholes for connecting new drains 150mm bore , making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and deforming benching as required all as specified .
Plain cement concrete 1:3:6 type C2 (using 40mm graded aggregate bed to drain pipes including packing under and haunching against the sides of pipes of 150mm bore after they are laid and tested complete all as specified and as directed.
10 mm thick (average) screed bed in CM (1:4) in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, finished even and smooth without extra cement complete all as specified and as directed. Note:- Polymeric membrane will be measured and paid separately
Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions. (iii) Applying two coats of Bituminous aluminium paint on top of APP membrane.
Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
INTERNAL ELECTRIFICATION WORKS
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following :-
One light/ fan point controlled by one one way switch.
One 5 Amps 3/5 pin socket outlet on same board with other switches.
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 6 pin 5/15 Amps and all as directed at site.
Switch piano flush type 5/6 Amps single pole one way 230 Volts complete all as secified.
Switch piano flush type 15/16 A single pole one way 230 V complete all as secified.
Socket Outlet 2 in 1 3/6 pin 5and15 Amp flush type 230 V complete all as secified.
Ceiling rose surface Bakelite, 65x50mm, 3 terminals complete all as specified and directed.
Sub main wiring concealed with 6 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, confirm to IS with copper conductor drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
Sheet metal enclosure DB 4 WAY,Single pole and neutral with 200 Amps rated bus bar,230 volts double door type including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface after taking down existing DB all as specified and directed.
MCB, DP, 240 Volts, AC 40 amp of breaking capacity 10 KA, C curve complete all as secified.
MCB SP 240 Volts AC 6 - 32 Amps of breaking capacity 10 KA, C curve complete all as secified.
LED light fittings decorative 20 Watt Recess/surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps complete all as specified.
Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed.
Ventilating fan 230 mm sweep heavy duty high speed, thermally protected motor conforming to IS complete all as specified and directed by Engineer-in-Charge.
Fan regulator electric stepped type heavy duty 300 watt, 250 volts flush type complete all as specified.
PATH / PAVEMENTS
Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in hard dense soil / disintegrated rocks including cutting of bushes, saplings and cutting trees not exc. 30m grith etc complete all as specified and directed.
Machine pressed precast concrete interlocking paver block (coloured) any shape and size conforming to IS 15658-2006 of 80mm thick M-35 grade (with grey cement and pigment) over 50 mm thick sand coushioning complete all as specified and directed.
Machine pressed precas concrete interlocking paver block (coloured) any shape and size conforming to IS 15658-2006 of 60mm thick M-35 grade etc complete (with grey cement and pigment) over 50 mm thick sand coushioning complete all as specified and directed.
PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping, bed plates, kerb not provided for complete all as specified and directed.
15 mm thick rendering in cm 1:6 on stone masonary surfaces or surfaces other than fair faces of brick work or on one side of lathing to be finished even and smooth (without using extra cement) complete all as specified and directed.
10 mm thick rendering in cm 1:4 on stone masonary surfaces or surfaces other than fair faces of brick work or on one side of lathing to be finished even and smooth (without using extra cement) complete all as specified and directed.
Preparation of newly plasterd surfaces and applying three coats of white wash complete all specified and directed.
EXTERNAL WATER SUPPLY
Galvanised steel water tubing 25 mm dia medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches,etc.,also cutting,screwing and waste and for making forged bends on piping as required at site.
Gun mental globe or gate valves, with iron wheeled head screwed both ends of iron pipes for 25 mm bore pipe fixed Complete all as specified and directed.
EXTERNAL ELECTRIFICATION
XLPE insulated armoured (under ground) heavy duty electric cable with standard aluminum conductor 1100 Volts grade of cross sectional area 16 sqmm 4 core laid in trenches/ducts/through pipes /in floor road/along the pole etc complete all as specified.
Precast concrete cable cover unreinforced, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
Sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed.
K K Construction Co
m/s prakash enterprise
shivshakticonstruction
SHREE CHAMUNDA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .